• Title/Summary/Keyword: average circuit

검색결과 426건 처리시간 0.026초

MAG용접의 Arc안정성에 미치는 Si의 영향 (Effect of Si on Arc Stability of MAG Welding)

  • 안영호;이종봉;엄동석
    • Journal of Welding and Joining
    • /
    • 제16권6호
    • /
    • pp.52-58
    • /
    • 1998
  • The effect of Si content in welding wires on th arc stability was investigate, in the region of short circuit transfer and spray transfer. In the region of short circuit transfer, with increasing Si content, average arcing time and average short circuit time were increased. Therefore, droplet transfer frequency was decreased, due to the increase of arcing time and peak current at the moment of arc-reiginition was increased, due to the increase of short circuit time. In the region of spray transfer, the fluctuations of arc current and arc voltage was the most stable in wire with Si content of about 00.60 wt.%.

  • PDF

MAG용접의 Arc안정성에 미치는 S의 영향 (Effect of S on Arc Stability of MAG Welding)

  • 안영호;이종봉;엄동석
    • Journal of Welding and Joining
    • /
    • 제17권1호
    • /
    • pp.55-61
    • /
    • 1999
  • The effect of S content in welding wires on the arc stability was investigated, in the region of short circuit transfer and spray transfer. In the region of short circuit transfer, with increasing S content, average arcing time and average short circuit time were decreased. Therefore, droplet transfer frequency was increased, due to the reduction of arcing time and peak current at the moment of arc-reiginition was decreased, due to the decrease of short circuit time. In the region of spray transfer, the fluctuation degree of arc current and arc voltage became more stable, with increasing S content.

  • PDF

GMAW 공정에서 아크 안정성의 실시간 측정 (Real-time estimation of arc stability in GMAW process)

  • 원윤재;부광석;조형석
    • Journal of Welding and Joining
    • /
    • 제8권1호
    • /
    • pp.31-42
    • /
    • 1990
  • Arc must be stable during welding first of all other factors for obtaining sound weldment, especially in the automation of welding process. Arc stability is somewhat sophisticated phenomenon which is not clearly defined yet. In consumable electrode welding, the voltage and current variation due to metal transfer enables to assess arc stability. Recently, statistical analyses of the voltage and current waveform factors are performed to assess the degress of arc stability which is assessed and controlled by operator's own experience by now. But, considering the increasing need and the trend of automation of welding process, it is necessary to monitor arc stability in real-time. In this sutdy, the modified stability index composed of two voltage and current wvaeform factors (arc time and short circuit time) reduced from four factors (arc time, short circuit time, average arc current and average short circuit current) in Mita's index by the welding electrical circuit modeling is proposed and verified by experiments to be well estimating arc stability in the static sense. Also, the recursive calculation form estimating present arc stability in the dynamic sense is developed for real-time estimation. The results of applying the recursive index during welding show good estimation of arc stability in real-time. Therefore, the results of this study offers the mean for real-time control arc stability.

  • PDF

2.5 mm2 HIV에 일반화염 및 DC 단락 전류를 인가하여 생성된 기공의 정량적 분포 해석 (Quantitative Distribution of Created Voids by Applying General Flame and DC Short-circuit Current to 2.5 mm2 HIV)

  • 김승삼;최충석
    • 한국안전학회지
    • /
    • 제28권4호
    • /
    • pp.38-42
    • /
    • 2013
  • This study performed the quantitative distribution analysis of created voids to an insulator when applying general flame and DC short-circuit current to 2.5 $mm^2$ HIV (600 V Grade Heat-Resistant Polyvinyl Chloride Insulated Wires). The diameter of cross-section of HIV normal product and the radius of conductor were measured to be 3.3 mm and 1.8 mm. The exterior of HIV exposed to general flame showed severe carbonization and its interior exhibited voids created by dechlorination reaction. This study observed the characteristics that, when the shortcircuit current applied for 2 seconds from a DC 12 V lead battery, the conductor and neighboring insulator were melted, causing the insulator adhering to the conductor. On average, 87 voids were created on 10 mm of the HIV. The average diameter of voids was 0.25 mm. In addition, it was found that, when the short-circuit current applied for 4 seconds, the interior of insulator in contact with conductor severely carbonized and showed exfoliation phenomenon. On average, 47 voids were created, with more voids at the bottom. The average diameter of voids was 0.20 mm. When the short-circuit current for 6 seconds, most parts of upper part of conductor was carbonized, 20 voids were created. The average diameter of voids was measured to be 0.24 mm. It could be seen that the created voids received little influence by the type of energy source and the number of created voids was reduced as the energy supply time increased.

Average 출력회로를 이용한 아날로그 병렬처리 기반 비터비 디코더 (Analog Parallel Processing-based Viterbi Decoder using Average circuit)

  • 김현정;김인철;김형석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년 학술대회 논문집 정보 및 제어부문
    • /
    • pp.375-377
    • /
    • 2006
  • A Analog parallel processing-based Viterbi decoder which decodes PRML signal of DVD has been designed by CMOS circuit. The analog processing-based Viterbi decoder implements are functions of the conventional digital Viterbi decoder utilizing the analog parallel processing circuit technology. The Analog parallel processing-based Viterbi decoding technology is applied for the PR(1,2,2,1) signal decoding of DVD. The benefits are low power consumption and less silicon consumption. In this paper, the comparison of the Analog parallel processing-based Viterbi Decoder which has a function of the error correction between Max operation and Average operation is discussed.

  • PDF

비계층적 구조를 갖는 종합정보 통신망에서 다원트래픽 성능분석 (Performance Analysis of Multi-Media Traffic in Nonhirerachical Structures)

  • 김제숭
    • 산업경영시스템학회지
    • /
    • 제20권41호
    • /
    • pp.103-112
    • /
    • 1997
  • In this paper, a nonhierarchial integrated information network with circuit switched and packet switched traffic is considered. It is assumed that circuit switched traffic is allowed to attempt an alternate path if the direct path is blocked, whereas packet switched traffic is not. The network uses a movable boundary scheme to allocate bandwidth dynamically. To analyze the performance of this type of network, EEBP(End to End Blocking Probability) is selected as a measure for circuit switched traffic and average time delay for packet switched traffic, respectively. EEBP and average time delay are derived analytically. Using the two proposed measure, the performance of the network under various bandwidth allocations and arrival patterns are observed. Moreover, the arrival rate of one link for circuit switched traffic is obtained from an approximation formula. Simulation results reveal the validity of the proposed approximation method.

  • PDF

ZVS를 이용한 부하병렬 공진형 DC-DC 컨버터의 특성해석 (A Characteristic Analysis of the Parallel Resonant DC-DC Converter Using ZVS)

  • 황계호;남승식;오경섭;강진욱;김동희;노채균
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.1026-1028
    • /
    • 2001
  • In this paper, proposal circuit proposes that load parallel resonant DC-DC Converter consist of L and C resonant tank circuit. Also, the capacitor$(C_1,\;C2)$ connected in switch are a common using by resonance capacitor and ZVS capacitor. The analysis of proposed circuit uses normalized parameter and characteristic estimation which is needed in each step before design is generally described the proposed circuit with the characteristics of average power and average output voltage etc. Alse, we conform a rightfulness theoretical analysis by comparing a theoretical values and experimental values obtained from experiment using MOSFET as switching devices.

  • PDF

비접촉 화학작용제 검출기의 MCT 광검출기를 위한 적분기 기반의 리드아웃 회로 구현 (Realization of Readout Circuit Through Integrator to Average MCT Photodetector Signals of Noncontact Chemical Agent Detector)

  • 박재현
    • 센서학회지
    • /
    • 제31권2호
    • /
    • pp.115-119
    • /
    • 2022
  • A readout circuit for a mercury-cadmium-telluride (MCT)-amplified mid-wave infrared (IR) photodetector was realized and applied to noncontact chemical agent detectors based on a quantum cascade laser (QCL). The QCL emitted 250 times for each wavelength in 0.2-㎛ steps from 8 to 12 ㎛ with a frequency of 100 kHz and duty ratio of 10%. Because of the nonconstant QCL emission power during on-duty, averaging the photodetector signals is essential. Averaging can be performed in digital back-end processing through a high-speed analog-to-digital converter (ADC) or in analog front-end processing through an integrator circuit. In addition, it should be considered that the 250 IR data points should be completely transferred to a PC during each wavelength tuning period of the QCL. To average and minimize the IR data, we designed a readout circuit using the analog front-end processing method. The proposed readout circuit consisted of a switched-capacitor integrator, voltage level shifter, relatively low-speed analog-to-digital converter, and micro-control unit. We confirmed that the MCT photodetector signal according to the QCL source can be accurately read and transferred to the PC without omissions.

Analysis of Parameter Effects on the Small-Signal Dynamics of Buck Converters with Average Current Mode Control

  • Li, Ruqi;O'Brien, Tony;Lee, John;Beecroft, John;Hwang, Kenny
    • Journal of Power Electronics
    • /
    • 제12권3호
    • /
    • pp.399-409
    • /
    • 2012
  • In DC-DC Buck converters with average current mode control, the current loop compensator provides additional design freedom to enhance the converter current loop performance. On the other hand, the current loop circuit elements append substantial amount of complexity to not only the inner current loop but also the outer voltage loop, which makes it demanding to quantify circuit and operating parameter effects on the small-signal dynamics of such converters. Despite the difficulty, it is shown in this paper that parameter effects can be analyzed satisfactorily by using an existing small-signal model in conjunction with a newly proposed simplified alternative. As a result of the study, new insight into average current mode control is uncovered and discussed quantitatively. Measurable experimental results on a prototype averaged-current-mode-controlled Buck converter are provided to facilitate the analytical study with good correlation.

개선된 평균 전류 제어 방식 역률 개선 회로의 제어에 관한 연구 (A Study on the control of Power Factor Correction Circuit by Advanced Average Current Control)

  • 김태규;김태우;최현의;김민찬;안호균;윤태성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.999_1000
    • /
    • 2009
  • The purpose of this paper is a study on the control of Power Factor Correction circuit by advanced average current control. The international standard organizations have made an effort to resolve these problems caused by the harmonics and announced the international standards for limiting the harmonic currents of the electrical devices and products. For improving power factor and reducing harmonics, many studies are progressed rapidly. In this study, we explain a method of an advanced average current control. And then, the performances of the PFC circuit applying a advanced average current control method are simulated and verified by Matlab/Simulink.

  • PDF