Low-power wireless communication System for Biosignal transmission (생체신호 무선 송수신을 위한 소형,저전력 통신시스템 개발)

  • Lee, Kang-Hwi;Lee, Jeong-Whan;Kim, Kyeong-Seop;Kim, Dong-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.370-372
    • /
    • 2005
  • Inconveniences which might arise in transmitting measured biological data based on cable protocols generally are recognized critical points in tele-monitoring environment and also restrict the mobility of the user. a. Especially, activity monitoring which is importantly recognized as a core parameter in ubiquitous healthcare arena and weight management, pervasive and wireless measuring technology is most needed. In this paper, we would like to suggest lower power, miniaturized communication system in order to solve the above problems. The suggested system is powered by small coin-size battery. Also, The suggested system is compared with a blue-tooth module which is generally available in the commercial market. Even though, the suggested system didn't have higher transmission rate, its low power consumption make the suggested system would be feasible in ubiquitous monitoring of biological signals in ubiquitous healthcare arena.

  • PDF

A study on the application of urban railway DC electric power for electric car charging system (전기차 충전시스템을 위한 도시철도 DC 전력의 활용방안 연구)

  • Kang, Hyun-Il;Kin, Youn-Sik;Sim, Jae-Suk;Im, Hyeong-Gil;Ryu, Ki-Seon;Lee, Gi-Seung
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1855-1860
    • /
    • 2010
  • Electric vehicles have reached a new level of development with introductions by Chrysler, Ford, Honda and Toyota. Today's charging technology includes conductive and inductive charging systems. There are three standardized charging levels: Level 1: charging can be done from a standard, grounded AC 120V, 3-prong outlet available in all homes; Level 2: charging is at AC 240V, 40 amp charging station with special consumer features to make it easy and convenient to plug in and charge EVs at home or at an EV charging station; Level 3: a high-powered charging "fast charge" technology currently under development that will provide a charge in less than 15 minutes. The incoming AC power is converted to DC and stored in the vehicle's batteries. In this paper, we investigated the application of urban railway DC electric power for electric car charging system.

  • PDF

Algorithms for Fire Sequencing Problem in Unplanned Artillery Attack Operation (포병부대 비계획 사격순서 결정 알고리즘)

  • Choi, Yong-Baek;Kim, Kyung-Sup
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.35 no.2
    • /
    • pp.37-44
    • /
    • 2012
  • This paper focuses on scheduling problems arising in the military. In planned artillery attack operations, a large number of threatening enemy targets should be destroyed to minimize fatal loss to the friendly forces. We consider a situation in which the number of available weapons is smaller than the number of targets. Therefore it is required to develop a new sequencing algorithm for the unplanned artillery attack operation. The objective is to minimize the total loss to the friendly forces from the targets, which is expressed as a function of the fire power potential, after artillery attack operations are finished. We develop an algorithm considering the fire power potential and the time required to destroy the targets. The algorithms suggested in this paper can be used in real artillery attack operations if they are modified slightly to cope with the practical situations.

EVALUATION OF STATIC ANALYSIS TOOLS USED TO ASSESS SOFTWARE IMPORTANT TO NUCLEAR POWER PLANT SAFETY

  • OURGHANLIAN, ALAIN
    • Nuclear Engineering and Technology
    • /
    • v.47 no.2
    • /
    • pp.212-218
    • /
    • 2015
  • We describe a comparative analysis of different tools used to assess safety-critical software used in nuclear power plants. To enhance the credibility of safety assessments and to optimize safety justification costs, $Electricit{\acute{e}}$ de France (EDF) investigates the use of methods and tools for source code semantic analysis, to obtain indisputable evidence and help assessors focus on the most critical issues. EDF has been using the PolySpace tool for more than 10 years. Currently, new industrial tools based on the same formal approach, Abstract Interpretation, are available. Practical experimentation with these new tools shows that the precision obtained on one of our shutdown systems software packages is substantially improved. In the first part of this article, we present the analysis principles of the tools used in our experimentation. In the second part, we present the main characteristics of protection-system software, and why these characteristics are well adapted for the new analysis tools. In the last part, we present an overview of the results and the limitations of the tools.

Analysis of system power flow margin on replacement of transmission line to DC line (송전선로 DC화에 따른 융통조류 마진 분석)

  • Hwang, Sungchul;Lee, Jaehyeong;Hwang, Pyungik;Yoon, Minhan;Jang, Gilsoo
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.420-421
    • /
    • 2015
  • Recently construction of new transmission line is getting harder because of social hostility to transmission tower. Howevere, load is converged in metropolitan area and power plants near this area are old and life of generator will end soon. Therefore, power to supply load in this area should be transmitted from east coast area and southern area. For these reasons, securement of transmission capacity without new transmission line construction is important. In this paper, effect of one circuit AC line change to DC transmission at the same transmission tower on the system available transfer capacity is analyzed.

  • PDF

Servo Gun-type Inverter Spot Welding System (서보건 타입 인버터 스폿용접시스템)

  • 김규식;김진우;원충연;최세완
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.5
    • /
    • pp.397-406
    • /
    • 2003
  • Resistance spot welding is widely employed in a manufacturing process. In recent years, the requirement for more sophisticated quality control procedures has been in mass production industries. The requirements for high productivity and better weld qualities have lead to the development of more widely available microcomputer-based control. In this study, the inverter type power source and welding servo gun are developed. As the results, we have some advantages over the previous methods such as pneumatic gun. One of them is that the precise pressure control can be attained during the welding process. In addition, production time and cost can be decreased.

Implementation of an Efficient Algorithm for a Single Phase Matrix Converter

  • Gola, Ajay Kumar;Agarwal, Vineeta
    • Journal of Power Electronics
    • /
    • v.9 no.2
    • /
    • pp.198-206
    • /
    • 2009
  • An algorithm is developed that enables a single-phase matrix converter (SPMC) to perform functions of a generalized single phase power electronics converter such as acting as a frequency changer, rectifier, inverter, and chopper. This reduces the need for new converter hardware. The algorithm is implemented first on computer simulation software Orcad Capture CIS version 9.1. Simulation results are presented for five types of converters with a control input variable that decides the 1) type of converter and 2) type of output waveform. The simulated results verify the working and operation of a generalized converter based on SPMC. Simulated results are verified with experimental results. Hardware design is obtained using readily available ICs and other components. The trigger circuit has been tested qualitatively by observing waveforms on CRO. The operation of the proposed system has been found to be satisfactory.

The Transformer Characteristics of the Active Clamp Forward Converter for Notebook Computer Adapter (노트북 컴퓨터 어탭터용 능동 클램프 포워드 컨버터 변압기 특성)

  • Yoon, Kyoung-Hyun;Kim, Chang-Sun
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.13-14
    • /
    • 2010
  • The active clamp forward converter provides zero voltage switching and low voltage stress in wide input voltage range. It has a high efficiency at a high switching frequency and the clamped energy is recovered to the input stage. It is available for the power adaptor circuit of notebook computer. The adaptor with 19.5V/200W output power is designed for notebook computer. Specially, it is considered the transformer properties of the converter in design process. The organized process is checked by the validity from the test of the active clamp forward converter.

  • PDF

Traction Motor-Inverter Utilized Battery Charger for PHEVs

  • Woo, Dong-Gyun;Kim, Yun-Sung;Kang, Gu-Bae;Lee, Byoung-Kuk
    • Journal of Power Electronics
    • /
    • v.13 no.4
    • /
    • pp.528-535
    • /
    • 2013
  • Most eco-friendly cars can adopt the concept of an integrated battery charger (IBC), which uses currently available motor drive systems. The IBC has a lot of strong points such as low cost and minimum space for the high voltage battery charger. On the other hand, it also has some defects caused by its structure. In this paper, the shortcomings of the conventional IBC for PHEVs with interior permanent magnet motors are discussed, and two advanced IBCs with improved performance are presented. Compared with the conventional IBC, the two advanced IBCs have plenty of strengths such as low common noise, high efficiency, simple sensing methods, etc. Then, the digital control algorithm is modified and a power loss calculation is carried out with simulation software. Finally, experimental results are provided to show the performance of the IBC systems.

HPF Application Test for PD Detection of XLPE Power Cable (XLPE 전력케이블의 부분방전 검출을 위한 HPF 적용 시험)

  • Kim, Jung-Yoon;Yang, Jong-Kyung;Park, Noh-Joon;Choi, Yong-Sung;Park, Dae-Hee;Lee, Yong-Sung
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.4
    • /
    • pp.161-165
    • /
    • 2006
  • In this paper, we developed HPF (high pass filter) consists of lumped LC components to decrease the noises that are detected in PD (partial discharge) measuring test, and adapted it to field test. We tested it under laboratory circumstances like the fields, and measured the phase change properties of detected signal in UHF sensor with Lemke Probe and oscilloscope (TDS-3054, Tektronix). As a result, we obtained available data showing the decrease of noises in the experiments with the developed HPF from the joint box of 22.9kV distribution line. The result can be adapted to prevent the degeneration of the XLPE power cable, and to observe and diagnosis the underground power transmission cable at the ultra-high voltage.