• Title/Summary/Keyword: available power

Search Result 1,805, Processing Time 0.036 seconds

A Power-stage Design and Analysis to Modularize the SAR of the Korea Multi-Purpose SATellite (위성 SAR 모듈화 구현을 위한 전원회로 설계 및 해석)

  • Park S.W.;Jang J.B.;Park H.S.;Jang S.S.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.93-96
    • /
    • 2003
  • Korea Multi-Purpose SATellite (KOMPSAT) uses software-controlled unregulated bus system In which the main bus is directly connected to a battery and the duty-ratio for PWM switch is generated by the on-board satellite software algorithm. In this paper, we propose a new power-stage circuit that can be available for modularization of a solar array regulator(SAR) which is used in the KOMPSAT. The operations at each mode and current sharing characteristics of the power-stage are analyzed and verified by simulation and experiments on a prototype converter.

  • PDF

Test of Homogeneity Baseon Complex Survey Data : Discussion Based on Power of Test

  • Heo, Sun-Yeong;Yi, Su-Cheol
    • Journal of the Korean Data and Information Science Society
    • /
    • v.16 no.3
    • /
    • pp.609-620
    • /
    • 2005
  • In the secondary data analysis for categorical data, situations often arise in which the estimated cell variances are available, but not the full matrix of variances. In this case researchers are often inclined to use Pearson-type test statistics for homogeneity. However, for a complex sample observed cell proportions are not distributed as multinomial and Pearson-type test statistic generally is not distributed asymptotically as chi-square distribution. This paper evaluates powers for Wald test and Pearson-type test and the first order corrected test of Pearson-type test for homogeneity. The resulting power curves indicate that as the misspecification effect increases, the amount of inflation of significance level and the loss of power Pearson-type test are getting more severe.

  • PDF

Environmental Noise Prediction of Power Plants (발전소 환경소음 예측)

  • 조대승;유병호
    • Journal of KSNVE
    • /
    • v.7 no.4
    • /
    • pp.621-629
    • /
    • 1997
  • For computer aided design and costruction of low noisy power plants, indoor and outdoor noise prediction program has been developed. The program utilizes the predefined data of noise sources and building materials and has the faculty to estimate the source level using the empirical formula in case of the measured data not being available. In the noise prediction, the mutual noise propagation between indoor and outdoor sites are considered. The outdoor noise source in the calculation of geometric divergence effects is modelled as the omni-directional finite line or planar source according to the source geometry and the receiving points. Outdoor noise prediction is carried out to consider the diffraction effect due to plant structures as well as the attenuation effect due to atmospheric absorption and soft ground. The results of indoor and outdoor noise prediction for a recently constructed diesel engine power plant show good agreement with the measured.

  • PDF

Parallel operation of rectifier with unit-power factor (단위역률 정류기의 병렬운전)

  • Lee, Seung-Heui;Kim, Tae-Won;Park, Jae-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1212-1213
    • /
    • 2011
  • PWM(pulse width modulation) rectifier has unit power factor and low harmonic distortion with high power conversion efficiency in entire loading range. These merits of PWM rectifier help the spread of DC distribution system. In addition, if multiple PWM rectifiers can be operated in parallel connection, maintenance process can be simple and reliability of power source can be advanced because of the hot swapping is available. The other way, the load unbalance among rectifiers can force a converter to stop by over current. The surge current by closed circuit composition between rectifiers can force switching devices damage. In this paper, some problems that can occur in case of parallel operation of PWM rectifiers and problem eliminating methods are considered.

  • PDF

A Study on the Voltage Compensation Converter to decrease fuel consumption of RTGC (RTGC의 연료절감을 위한 전압 보상 컨버터에 관한 연구)

  • Bayasgalan, Bayasgalan;Ryu, Ji-Su;Han, Dong-Hwa;Lee, Young-Jin;Lee, Sang-Ho;Choe, Gyu-Ha
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.280-282
    • /
    • 2011
  • This paper presents a development of voltage compensation dc/dc converter to decrease fuel consumption of RTGC system. We used 3-phase interleaved converter, which has the same structure as the commercially available three-phase inverter, is used. RTGC system is supplied the power from diesel-engine generator. According to power demand, engine speed is varying 20~60Hz, and voltage is varying 210Vac ~ 480Vac. When idle mode or low power operation dc/dc converter operates by constant output voltage control. The perpormance of converter is evaluated through several experiments with a real RTGC. Proposed system can cut down fuel consumption by 36% at idle mode operation.

  • PDF

Evaluation of Optimal Transfer Capability in Power System interconnection (연계된 계통간의 최적 송전용량 산정)

  • Son, Hyun-Il;Choi, Ah-Reum;Lee, Sung-Hoon;Kim, Jin-O;Jeon, Dong-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.195_196
    • /
    • 2009
  • As the electrical power industry is restructured, the electrical power exchange is becoming extended. One of the key information used to determine how much power can be transferred through the network is known as available transfer capability (ATC). To calculate ATC, traditional deterministic approach is based on the severest case, but the approach has the complexity of procedure. Therefore, novel approach for ATC calculation is proposed using cost-optimization method in this paper, and is compared with well-being method and risk-benefit method. This paper proposes the optimal transfer capability of HVDC system between mainland and a separated island in Korea through these three methods. These methods will consider production cost, wheeling charge through HVDC system and outage cost with one depth (N-1 contingency).

  • PDF

Developement of planetary differential type traction drive (차동유성형 마찰드라이브의 개발)

  • 이종원;오세훈;최동엽;이대길;전한수
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.3
    • /
    • pp.35-40
    • /
    • 1997
  • The traction drive has advantages of having high efficiency and transmitting the power without blacklash. However, when high ratio of speed reduction is desired, excessively large size is required. In this study, a new type of traction drive is invented, designed and manufactured so that stable speed reduction mech- anisms are available by adopting a cross roller type drive. It has a simple structure, but produces high speed reduction ratio. Power loss is observed, and also, driving torque and torque transfer efficiency are calculated. Pre-loads are needed in order that the traction drive transfers power without slipping, and the spacer is enlarged due to the pre-loading. After all, the key point of pre-load mechanism is that the spacer's diameter becomes larger as pre-loads are applied.

  • PDF

A Comparison of the Failure Mechanism for High Power Converted White LEDs(3W) (고 출력 백색 변환용 LED(3W용)의 고장메커니즘 비교)

  • Yun, Yang-Gi;Jang, Jung-Sun
    • Journal of Applied Reliability
    • /
    • v.12 no.3
    • /
    • pp.177-186
    • /
    • 2012
  • This paper presents a comparison of the failure mechanism for high power converted white LEDs(3W) with the commercially available YAG:Ce and silicate phosphor. We carry out the normal aging life test for 10,000 hours, the high temperature aging test for 8,000 hours, the high temperature and humidity aging test for 8,000 hours and the current aging testing for 5,000 hours. The optical and electrical parameters of LEDs were monitored, such as lumen, correlated color temperature (CCT), chromaticity coordinates(x, y), thermal resistance, I -V curve and spectrum intensity. The stress induced a luminous flux decay on LED in all experiments and causes a failure. So we try to find out what's a main failure mechanism for a high power LED.

A study for PDMS Application Scheme of Digital S/S with IEC61850 Base (IEC61850 기반 디지털 변전시스팀에서의 PDMS 적용 방안에 관한 연구)

  • Lee, D.C.;Kim, H.S.;Bae, U.L.;Min, B.W.
    • Proceedings of the KIEE Conference
    • /
    • 2006.05a
    • /
    • pp.78-82
    • /
    • 2006
  • The Partial Discharge Monitoring System is technology which is available to measure & analysis the partial discharge of Power equipment. This technology is in the limelight as a pre-forecast system of equipment defect but there are some problems like no protocol standard, layered network management and the limitation of physical size. This paper presents whole system structure includes engineering centers, LN(Logical Node) to apply PDMS for, base-digital substation system, ICE61850 compatible Condition Monitoring &Diagnosis (CMD), Local Unit(LU), Intelligent Electronic Device (IED) for the solution scheme of these limitations.

  • PDF

A Study on the Improvement of Intermodulation Distortion for Multistage Microwave Two-port Networks (다단 마이크로파 2-포트 회로망의 상호변조 왜곡 개선에 관한 연구)

  • Eui Joon Park
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.5
    • /
    • pp.50-57
    • /
    • 1994
  • The analysis of the two-tone intermodulation distortion of multistage two-ports with gain and mismatching losses is presented with simplified two-port analyses and statistical viewpoint. The uncertainty obtained from unknown phase angles of the intermodulation distortion signals to the system designer is reduced using stochastic process, hence improving the accuracy of the solution. Based on the dc power dependance of third-order intercept point of each stage, the new efficient method for improving the total intercept point is also suggested with only the relation of dc power and available power gain criteria. Experimental verification on specific amplifiers used for cellular mobile communication comparing predicted and measured intercept points for various power conditions is presented.

  • PDF