• 제목/요약/키워드: available power

검색결과 1,805건 처리시간 0.034초

Improvement of Available Battery Capacity in Electric Vehicles

  • Liu, Yow-Chyi
    • Journal of Power Electronics
    • /
    • 제13권3호
    • /
    • pp.497-506
    • /
    • 2013
  • This paper proposes a new method to improve the available battery capacity in electric vehicles by connecting lead-acid batteries with lithium-ion battery in parallel to supply power. In addition, this method combines the discharge characteristics of batteries to improve their efficiency and lower their cost for electric vehicles. A lithium-ion battery set is used to connect with N sets of lead-acid batteries in parallel. The lead-acid battery supplies the initial power. When the lead-acid battery is discharged by the load current until its output voltage drops to the cut-off voltage, the power management unit controls the lead-acid battery and changes it to discharge continuously with a small current. This discharge can be achieved by connecting the lead-acid battery to a lithium-ion battery in parallel to supply the load power or to discharge its current to another lead-acid or lithium-ion battery. Experimental results demonstrates that the available capacity can be improved by up to 30% of the rated capacity of the lead-acid batteries.

풍력단지 제어를 위한 생산가능 출력에 대한 연구 (Study on the Available Power of a Wind Turbine for Wind Farm Control)

  • 오용운;백인수;남윤수;라요한
    • 한국태양에너지학회 논문집
    • /
    • 제34권1호
    • /
    • pp.1-7
    • /
    • 2014
  • A study on the available power of a wind turbine to be used for wind farm control was performed in this study, To accurately estimate the available power it is important to obtain a suitable wind which represents the three dimensional wind that the wind turbine rotor faces and also used to calculate the power. For this, two different models, the equivalent wind and the wind speed estimator were constructed and used for dynamic simulation using matlab simulink. From the comparison of the simulation result with that from a commercial code based on multi-body dynamics, it was found that using the hub height wind to estimate available power from a turbine results in high frequency components in the power prediction which is, in reality, filtered out by the rotor inertia. It was also found that the wind speed estimator yielded less error than the equivalent wind when compared with the result from the commercial code.

Power Smoothening Control of Wind Farms Based on Inertial Effect of Wind Turbine Systems

  • Nguyen, Thanh Hai;Lee, Dong-Choon;Kang, Jong-Ho
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권3호
    • /
    • pp.1096-1103
    • /
    • 2014
  • This paper proposes a novel strategy for attenuating the output power fluctuation of the wind farm (WF) in a range of tens of seconds delivered to the grid, where the kinetic energy caused by the large inertia of the wind turbine systems is utilized. A control scheme of the two-level structure is applied to control the wind farm, which consists of a supervisory control of the wind farm and individual wind turbine controls. The supervisory control generates the output power reference of the wind farm, which is filtered out from the available power extracted from the wind by a low-pass filter (LPF). A lead-lag compensator is used for compensating for the phase delay of the output power reference compared with the available power. By this control strategy, when the reference power is lower than the maximum available power, some of individual wind turbines are operated in the storing mode of the kinetic energy by increasing the turbine speeds. Then, these individual wind turbines release the kinetic power by reducing the turbine speed, when the power command is higher than the available power. In addition, the pitch angle control systems of the wind turbines are also employed to limit the turbine speed not higher than the limitation value during the storing mode of kinetic energy. For coordinating the de-rated operation of the WT and the storing or releasing modes of the kinetic energy, the output power fluctuations are reduced by about 20%. The PSCAD/EMTDC simulations have been carried out for a 10-MW wind farm equipped with the permanent-magnet synchronous generator (PMSG) to verify the validity of the proposed method.

연계계통에서 가용송전용량 평가를 위한 최적화 알고리즘의 비교 (Comparison of Optimization Algorithms for Available Transfer Capability Assessment in Interconnected Systems)

  • 김규호;송경빈
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권12호
    • /
    • pp.549-554
    • /
    • 2006
  • Available transfer capability(ATC) is an important indicator of the usable amount of transmission capacity accessible by several parties for commercial trading in power transaction activities. This paper deals with an application of optimization technique for available transfer capability(ATC) calculation and analyzes the results of ATC by considering several constraints. Especially several optimization techniques are used to solve the ATC problem with state-steady security constraints. The results are compared with that of repeat power flow(RPF), sequential quadratic programming(SQP) and linear programming(LP). The proposed method is applied to 10 machines 39 buses model systems to show its effectiveness.

WiBro 휴대 인터넷 시스템을 위한 자원 할당 알고리듬 비교 분석 (Performance Analysis of Resource Allocation Scheme for WiBro Portable Internet System)

  • 여혜진;양주영;김정호
    • 한국통신학회논문지
    • /
    • 제30권6A호
    • /
    • pp.455-464
    • /
    • 2005
  • 본 논문에서는 OFDMA, TDD 전송방식을 채택한 WiBro 시스템 표준의 resource 할당 알고리듬을 시뮬레이션을 통해 구현하였고, bandwidth efficiency를 보다 더 높이기 위한 알고리듬을 제안하였다. 제안하는 알고리듬은, 변조지수를 최대로 하여 채널 이득이 큰 subchannel부터 작은 subchannel 순서로 비트를 할당한다. 이 때 subchannel의 수를 증가시킴으로 인해 전송되어야 할 power가 증가하는데, 이 power가 available power를 넘는 순간에 할당되는 subchannel의 변조지수를 조정하여 available power를 넘지 않게 하는 방법이다. 기존의 greedy algorithm이나 WiBro 시스템과 비교하였을 때, 제안하는 알고리듬을 적용할 경우 power가 제한되어 있는 것으로 인해 사용되는 subchannel의 수가 현저히 작아져서 bandwidth efficiency 측면에서는 좋은 성능을 나타내게 한다. 하지만 channel attenuation이 큰 환경에서는 최대 throughput이 떨어지는 문제점이 발생하는데, 타 시스템에서 지원하는 만큼의 throughput을 보장하는 문제 역시 중요하기 때문에, 이를 극복하기 위해 이 경우에는 available power를 추가 할당하여 사용되는 subchannel수를 증가시켰다. 이 경우, 기존 시스템과 비슷한 throughput을 보장하면서 bandwidth 이득은 더 높게 얻을 수 있음을 확인하였다.

파랑에너지 해석 및 가용량 평가 연구 (Estimation of Wave Power in Korean Coastal Waters)

  • 김현주;최학선;김선경
    • 한국해양공학회지
    • /
    • 제12권1호
    • /
    • pp.107-112
    • /
    • 1998
  • The purpose of this study is to analyze the amount of available wave power and its characteristics related to the development of apractical system for ocean wave energy conversion in Korean coastal waters. The analysis method of wave power was established through comparison between theory and numerical simulation of deep sea wave by Inverse Fourier Transform with random phase method. Based on the results of comparison, wave power was estimated by use of data set from observed offshore and coastal waves and hindasted deep sea waves around the Korean peninsula. Annual mean wave power is estimated as about 1.8 ~ 7.0 kW for every metre of wave frontage at East sea, 1.5~5.3 kW at South sea and 1.0 ~ 4.1 kW at West sea, respectively. Mean wave power along deep sea front of coastal waters of Korea amounts to about 4.7 GW. Regional distribution and seasonal variation of wave power were discussed to develop practical utilization system of wave power of not so high grade of available wave power.

  • PDF

중소형선(中小型船)의 기관부중량추정(機關部重量推定) (Estimation of Machinery Weights of the Medium and Small-sized Ships)

  • 김극천
    • 대한조선학회지
    • /
    • 제3권1호
    • /
    • pp.25-32
    • /
    • 1966
  • For preliminary estimation of ships' machinery weights, many papers giving well-judged data and discussions for rational method of estimation, such as [1], [2], [3], [4], [5], [6], are available, however, they are mostly concerned with large ships propelled by power more than about 2, 000 horsepower. Regarding the medium and small-sized ships, as far as the author is aware, fragmental data and vague discussions found in various technical literature are the all available. In this paper, available data concerned with machinery weights of commercial ships propelled by direct-drive diesel plants of power below 3, 000 horsepower with single screw propeller are collected and analysed to obtain systematic data Fig. 1 and Fig. 2 as weight to power ratio versus power per shaft diagrams together with suplementary data Fig. 1 and Fig. 3. Influences of various factor such as revolutions per minute, mean effective pressure, type and construction of the main units on machinery weights are also investigated in detail to give a better guidance for logical and rational utlization of the proposed diagrams in preliminary estimation of machinery weights.

  • PDF

가용송전용량을 고려한 각 발전회사의 발전비용 최소화 기법 개발에 관한 연구 (A Study on the Minimization of Generation Cost of an Individual Power Generation Considering Available Transfer Capability(ATC))

  • 정성원;김재현
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권12호
    • /
    • pp.586-591
    • /
    • 2005
  • This paper presents a method of minimizing of generation cost on individual electrical power utility. The method is based on the Economic Dispatch (ED) and linear Available Transfer Capability (ATC). The economic dispatch redistributes the total load to individual units to minimize the generation cost without transmission network constraints. The proposed method is implemented using ATC calculated from Power Transfer Distribution Factor (PTDF) for the transmission network constraints. The performance of the proposed method has been tested for the IEEE-30 bus system. It has also been observed that the results of the proposed method is compared with that of optimal power flow.

Reactivity balance for a soluble boron-free small modular reactor

  • van der Merwe, Lezani;Hah, Chang Joo
    • Nuclear Engineering and Technology
    • /
    • 제50권5호
    • /
    • pp.648-653
    • /
    • 2018
  • Elimination of soluble boron from reactor design eliminates boron-induced reactivity accidents and leads to a more negative moderator temperature coefficient. However, a large negative moderator temperature coefficient can lead to large reactivity feedback that could allow the reactor to return to power when it cools down from hot full power to cold zero power. In soluble boron-free small modular reactor (SMR) design, only control rods are available to control such rapid core transient. The purpose of this study is to investigate whether an SMR would have enough control rod worth to compensate for large reactivity feedback. The investigation begins with classification of reactivity and completes an analysis of the reactivity balance in each reactor state for the SMR model. The control rod worth requirement obtained from the reactivity balance is a minimum control rod worth to maintain the reactor critical during the whole cycle. The minimum available rod worth must be larger than the control rod worth requirement to manipulate the reactor safely in each reactor state. It is found that the SMR does have enough control rod worth available during rapid transient to maintain the SMR at subcritical below k-effectives of 0.99 for both hot zero power and cold zero power.

이중여자 유도형 풍력발전기 기반 풍력단지의 계통 연계점 전압제어 (Voltage Control for a Wind Power Plant Based on the Available Reactive Current of a DFIG and Its Impacts on the Point of Interconnection)

  • ;김진호;;강용철
    • 전기학회논문지
    • /
    • 제65권1호
    • /
    • pp.23-30
    • /
    • 2016
  • Wake effects cause wind turbine generators (WTGs) within a wind power plant (WPP) to produce different levels of active power and subsequent reactive power capabilities. Further, the impedance between a WTG and the point of interconnection (POI)-which depends on the distance between them-impacts the WPP's reactive power injection capability at the POI. This paper proposes a voltage control scheme for a WPP based on the available reactive current of the doubly-fed induction generators (DFIGs) and its impacts on the POI to improve the reactive power injection capability of the WPP. In this paper, a design strategy for modifying the gain of DFIG controller is suggested and the comprehensive properties of these control gains are investigated. In the proposed scheme, the WPP controller, which operates in a voltage control mode, sends the command signal to the DFIGs based on the voltage difference at the POI. The DFIG controllers, which operate in a voltage control mode, employ a proportional controller with a limiter. The gain of the proportional controller is adjusted depending on the available reactive current of the DFIG and the series impedance between the DFIG and the POI. The performance of the proposed scheme is validated for various disturbances such as a reactive load connection and grid fault using an EMTP-RV simulator. Simulation results demonstrate that the proposed scheme promptly recovers the POI voltage by injecting more reactive power after a disturbance than the conventional scheme.