• 제목/요약/키워드: auxiliary teeth

검색결과 37건 처리시간 0.017초

전기자 분산배치 집중권 PMLSM의 단부 효과 저감을 위한 보조극과 보조치 조합에 관한 연구 (A Study on Auxiliary Pole and Teeth Combinations for Edge Effect Reduction of Stationary Discontinuous Armature PM-LSM with Concentrated winding)

  • 김성진;김용재
    • 전기학회논문지
    • /
    • 제61권11호
    • /
    • pp.1611-1616
    • /
    • 2012
  • Recently, the stationary discontinuous armature Permanent Magnet Linear Synchronous Motor(PM-LSM) was suggested as a driving source for long-distance transportation system. However, as these motors arrange armatures discontinuously, there occurs an edge which causes the cogging force. This works as a factor that bothers acceleration and deceleration that takes place when movers enter into and eject from the armatures. Therefore, installation of auxiliary teeth on the edge of armature of PM-LSM is suggested in order to reduce cogging force caused by the edge when the armature is placed in a discontinuous arrangement. But length of auxiliary teeth can be changed if install it with auxiliary pole in order to decrease more and more edge cogging force. On this, in the study, decided on a design variable of auxiliary teeth and used 2-D FEA, and examined edge cogging force characteristic along this in order to grasp length of auxiliary teeth changed according to installation positions of an auxiliary pole.

Design of Auxiliary Teeth on the Edge of Stationary Discontinuous Armature PM-LSM with Concentrated Winding

  • Kim, Sung-Jin;Kim, Yong-Jae;Jung, Sang-Yong
    • Journal of Magnetics
    • /
    • 제18권3호
    • /
    • pp.352-356
    • /
    • 2013
  • Recently, the stationary discontinuous armature, Permanent Magnet Linear Synchronous Motor (PM-LSM), was suggested as a driving source for long-distance transportation system. However, as these motors arrange armatures discontinuously, an edge occurs thereby leading to a cogging force. This works as a factor that hinders the acceleration and deceleration that takes place when movers enter into and eject from armatures. Therefore, in this study, the installation of auxiliary teeth on the edge of the armature of PM-LSM is suggested in order to reduce the cogging force caused by the edge when the armature is placed in a discontinuous arrangement. Auxiliary teeth are optimally designed by a 2-D numerical analysis using the finite element method was performed to generate the optimum design of the auxiliary teeth. The validity of the study was confirmed through the comparison of the cogging force induced at the edge in respect to the design parameter using the basic model.

A Study on the Reduction of Cogging Force of Stationary Discontinuous Armature Linear Synchronous Motor Using Auxiliary Teeth

  • Kim, Yong-Jae;Lee, Kyu-Myung;Watada, Masaya
    • Journal of Magnetics
    • /
    • 제16권3호
    • /
    • pp.281-287
    • /
    • 2011
  • The stationary discontinuous armatures that are used in permanent magnet linear synchronous motors (PM-LSMs) have been proposed as a driving source for transportation systems. However, the stationary discontinuous armature PM-LSM contains the outlet edges which always exist as a result of the discontinuous arrangement of the armature. For this reason, the high alteration of the outlet edge cogging force produced between the armature's core and the mover's permanent magnet when a mover passes the boundary between the armature's installation part and non-installation part has been indicated as a problem. Therefore, we have examined the outlet edge cogging force by installing the auxiliary teeth at the armature's outlet edge in order to minimize the outlet edge cogging force generated when the armature is arranged discontinuously. Moreover, we obtained the calculation by analyzing the shape of the auxiliary teeth in which the outlet edge cogging force is minimized the most.

보조치를 이용한 가동 코일형 PMLSM의 단부효과에 의한 Detent Force 저감에 관한 연구 (A Study on the Reduction of Detent Force caused by End-Effect for Moving Coil Type PMLSM Using Auxiliary-teeth)

  • 정수권;주건배;이동엽;김규탁
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권9호
    • /
    • pp.459-464
    • /
    • 2006
  • The detent force by end-effect has an undesired influence on moving coil type Permanent Magnet Linear Synchronous Motor(PMLSM). So, the reduction of detent force by end-effect is especially required for the improvement of thrust characteristics. In this paper, in order to reduce detent force by end-effect, the auxiliary-teeth is installed at the end part of mover. It is also analyzed by Finite Element Analysis(FEA) and optimized by using neural network. By comparison, the detent force is reduced about 41.4[%] comparing to that of basic model.

Reduction Design of End Edge Effect in Stationary Discontinuous Armature PMLSM combined with Skewed Magnets and Stair Shape Auxiliary Teeth

  • Kim, Min-Seok;Kim, Yong-Jae
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제3권4호
    • /
    • pp.362-366
    • /
    • 2014
  • In recent years, a permanent magnet linear synchronous motor (PMLSM) has been used in various kinds of transportation applications for its relative high power density and efficiency. The general transportation system arranges the armature on the full length of transportation lines. However, when this method is applied to long distance transportation system, it causes increase of material cost and manufacturing time. Thus, in order to resolve this problem, we suggested stationary discontinuous armature PMLSM. However, the stationary discontinuous armature PMLSM contains the edges which always exist as a result of the discontinuous arrangement of the armature. These edges become a problem because the cogging force that they exert bad influences the controllability of the motor. Therefore, in this paper we proposed the combination of skewed magnets and stair shape auxiliary teeth to reduce the force by edge effect. Moreover, we analyzed the influence of the design factors by using a 3-D finite element method (FEM) simulation tool.

변형된 설측호선 장치를 이용한 매복 대구치의 인위적 맹출

  • 박상진;문철현
    • 대한치과의사협회지
    • /
    • 제44권2호통권441호
    • /
    • pp.123-132
    • /
    • 2006
  • Patients who have impacted tooth are found commonly in orthodontic treatment. Although it is difficult to find the cause of impacted teeth, the most common, causes are prolonged retention of the deciduous teeth, trauma, aberrant sequence of eruption, lack of space and deficiency of Vitamin D. Impacted teeth may lead to esthetic and functional problems and root resorption of adjacent teeth, so we should treat it as soon as possible. Commonly used treatment method is the following: After surgically uncovering of the impacted teeth, a bond of orthodontic appliance is established, and orthodontic traction is started with a removable or fixed appliance. We used the modified lingual arch with a soldered auxiliary appliance in lingual arch for traction of lower impacted teeth. The modified lingual arch could control the magnitude and direction of the applied force with one-arch treatment, and also could give continuous force to impacted tooth without patient patient cooperation. We achieved good results with the modified lingual arch.

  • PDF

Optimal Design for Thrust Ripple Reduction of Stationary Distributed-Armature System

  • Park, Eui-Jong;Jung, Sang-Yong;Cho, Kyoung-Pil;Kim, Yong-Jae
    • Journal of Magnetics
    • /
    • 제21권1호
    • /
    • pp.72-77
    • /
    • 2016
  • Although the initial cost of permanent-magnet linear synchronous motors is high owing to the installation of armatures over the full length of the transportation lines, linear motors are useful for transportation systems because of their high speed, acceleration, and deceleration. For these reasons, research into reducing the cost of linear motors is necessary, and a stationary distributed-armature system has been suggested for installing armatures in sections where acceleration and deceleration of the mover are required. However, each armature has ends that significantly increase the cogging force, resulting in the increase in the thrust ripple of the mover. Therefore, in order to improve the thrust ripple of the system, the present study aims to provide auxiliary teeth on both ends of the armature to achieve an optimal design through an analysis of the contribution ratio with respect to factors regarding the design of the experiment and the objective function.

단부효과에 의한 PMLSM의 디텐트력 저감을 위한 보조코어 최적설계 (The Auxiliary Core Optimal Design of PMLSM to Reduce Detent Force by End Effect)

  • 장기봉;안호진;김규탁
    • 전기학회논문지
    • /
    • 제59권3호
    • /
    • pp.543-548
    • /
    • 2010
  • There are produced the detent force caused by slot-teeth structures, end-effect and parallel magnetization of permanent magnet in permanent magnet linear synchronous motor. In this paper, we proposed to establish the auxiliary core for reducing detent force which is generated the discontinuity of magnetic circuits by end effect. The optimal design of the auxiliary core used a finite element analysis and design of experiment. To demonstrate the validity of the paper, the experiment results are compared with analysis ones.

폐경여성의 골밀도와 잔존치아의 관련성 (Association between bone mineral density and remaining teeth in postmenopausal women)

  • 이경수;김창숙
    • 한국치위생학회지
    • /
    • 제14권3호
    • /
    • pp.319-326
    • /
    • 2014
  • Objectives : The purpose of the study is to investigate the factors affecting the bone density and the relationship between bone density and remaining teeth by using data from 2007 to 2009 of the 4th Korean National Health and Nutrition Examination Survey(KNHANES). Methods : The subjects were 1,829 postmenopausal women over 50 years old from the data of the 4th KNHANES. Results : The bone density had the significant difference in 'age' and 'level of education' and remaining teeth had the significant difference in age, monthly income and level of education. The bone mineral density and remaining teeth had the significantly different from subjective general health, smoking, drinking, physical activity. The oral health behaviors and remaining teeth had the significantly associated in subjective oral health status, frequency of tooth brushing, use of auxiliary oral hygiene product, and recent oral examination. Conclusions : The number of remaining teeth is below 9.27 compared with the normal group.

장거리 반송용 전기자 분산배치 분포권 PMLSM의 추력맥동 저감을 위한 단부형상 설계 (The Design of End Edge Shape for Reduction of Long-Distance Transportation Stationary Discontinuous Armature PMLSM Thrust Ripple with Distributed Winding)

  • 박의종;김용재
    • 한국전자통신학회논문지
    • /
    • 제8권11호
    • /
    • pp.1675-1680
    • /
    • 2013
  • 최근 저소음, 고속, 고추력의 반송장치가 요구됨에 따라 영구자석 선형동기전동기가 대두되고 있으나 반송경로 전장에 전기자를 설치하는 선형 동기전동기의 특성으로 인해 장거리 반송장치에 적용시 설치비용의 증가를 가져온다. 따라서 우리는 전기자를 분산시켜 배치하는 방법을 제안하여 비용증가의 문제점을 해결하고자 하였다. 하지만 가동자의 진행시 분산배치된 전기자 사이를 통과하게 되면 전기자의 불연속 구간인 단부에 의해 디텐트력이 발생하여 추력 맥동이 발생하고 기기 성능저하와 소음, 진동의 원인이 된다. 따라서 본 논문에서는 단부에 의한 영향을 저감하기 위해 전기자 끝단의 치 높이와 보조치 형상에 따른 디텐트력의 특성을 파악하고 다구찌의 실험계획법을 이용하여 단부 효과를 가장 저감할 수 있는 형상을 제안하였다.