• 제목/요약/키워드: auxiliary method

검색결과 816건 처리시간 0.031초

Efficacy of Auxiliary Traits in Estimation of Breeding Value of Sires for Milk Production

  • Sahana, G.;Gurnani, M.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제12권4호
    • /
    • pp.511-514
    • /
    • 1999
  • Data pertaining to 1111 first lactation performance record of Karan Fries (Holstein-Friesian $\times$ Zebu) cows spread over a period of 21 years and sired by 72 bulls were used to examine the efficiency of sire indices for lactation milk production using auxiliary traits. First lactation length, first service period, first calving interval, first dry period and age at first calving were considered as auxiliary traits. The efficiency of this method was compared with simple daughter average index (D), contemporary comparison method (CC), least-square method (LSQ), simplified regressed least-squares method (SRLS) and best linear unbiased prediction (BLUP) for lactation milk production. The relative efficiency of sire evaluation methods using one auxiliary trait was lower (24.2-32.8%) in comparison to CC method, the most efficient method observed in this study. Use of two auxiliary traits at a time did not further improve the efficiency. The auxiliary sire indices discriminate better among bulls as the range of breeding values were higher in these methods in comparison to conventional sire evaluation methods. The rank correlation between breeding values estimated using auxiliary traits were high (0.77-0.78) with CC method. The rank correlation among auxiliary sire indices ranged from 0.98 to 0.99, indicating similar ranking of sire for breeding values of milk production in all the auxiliary sire indices.

접지임피던스 측정시 보조전극의 배치 기준 연구 (Placement Standard Research of Auxiliary Probes when Measuring Ground Impedance)

  • 김동우;길형준;김동욱;이기연;문현욱
    • 전기학회논문지
    • /
    • 제60권10호
    • /
    • pp.1984-1991
    • /
    • 2011
  • Among ground impedance measurement methods, the fall-of-potential method is the most thorough and reliable method. In the fall-of-potential method, ground electrode and auxiliary probes are placed in a straight line, and then, auxiliary potential probe is moved away from the ground electrode. The point at which plotted resistance curve flattens out is taken as right position of auxiliary potential probe. However, in some cases, it is hard to place ground electrode and auxiliary probes in a straight line. Therefore, we provided alternative placement method in this research. The method can be easily applicable to placing auxiliary probes. Also, this paper analyzed and compared ground impedance measurement standards of large grounding systems. Based on the analysis, practical measurement method using an earth tester was proposed. The proposed methods presented in this paper will be useful when determining locations of auxiliary probes in alternative positions, and the methods can be applied practically and easily.

대체 보조전극을 이용한 접지저항 측정 신뢰성 분석 (Trust Analysis of Ground Resistance Measurements by the Substitute Auxiliary Electrode)

  • 이상익;유재근;전정채;전현재
    • 전기학회논문지P
    • /
    • 제56권2호
    • /
    • pp.109-114
    • /
    • 2007
  • This paper summarize about the auxiliary electrode measured a ground resistance. The method to measure a ground resistance is the fall-of-potential method to using an auxiliary electrode. And an auxiliary electrode must be set up on the ground. Today it is so difficult to set up the auxiliary electrode on the ground because of many concrete building and many paved roads. So this paper is regarding a trust analysis of the ground resistance measurement by the substitute auxiliary electrode. It substituted a iron structure around the building, a neutral line multiplex ground to earth, a wire net for auxiliary electrode. This information is confirmed bv compared with the measurement value.

보조전원장치의 단락부하 차단기 개방을 위한 제어방법 (Control Method for Cut-out of Shorted Load in the Auxiliary Power Supply)

  • 황광철;조국춘;최종묵
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1998년도 추계학술대회 논문집
    • /
    • pp.249-254
    • /
    • 1998
  • This paper describes the control methods to cut out the NFB(No Fuse Breaker) of shorted load in the auxiliary power supply, Generally, when the short-circuit occurs in the load of the auxiliary power supply, the auxiliary power supply stops the operation according to the protection sequence. Finally, the other auxiliary power supply stops the operation by the same fault, To resolve this problem, we suggest the control method to trip the NFB of shorted load. That is, when the short circuit occurs, the controller changes control mode from voltage mode to current mode without the operation of output contactor(SIVK) in the auxiliary power supply. The auxiliary power supply provides a large current for the short-circuit load. After some time, the NFB of the short-circuit load is cut off and the auxiliary power supply Provides stable voltage for the loads except for the short-circuit load.

  • PDF

전위강하법에 의한 접지저항 측정시 보조전극의 위치변화에 따른 오차 분석 (Measurement Error Analysis of Ground Resistance Using the Fall-of-Potential Method According to the Locations of Auxiliary Probes)

  • 김동우;길형준;김동욱;이기연;문현욱;김향곤
    • 전기학회논문지P
    • /
    • 제59권2호
    • /
    • pp.222-231
    • /
    • 2010
  • This paper presents numerical analysis of measurement errors of ground electrode using the fall-of-potential method. In order to analyze ground resistance error according to the positions of auxiliary probes, firstly, national and international standards were researched. Secondly, numerical ground resistance error of hemispheric electrode was analyzed according to the locations of auxiliary probes and the angle between probes. Then, error-reduced positions of auxiliary probes were shown according to the distance to auxiliary current probe versus ground electrode size. Finally, error compensation method was presented. The results presented in this paper provide useful information regarding ground resistance error of alternative positions of auxiliary probes in case that the auxiliary probes could not be located at the proper position in such cases as there are buildings, roadblock or underground metallic pipe at that position.

대체 보조전극을 이용한 접지저항 측정값 비교 (Comparison of Ground Resistance Measurement Value by the Substitute Auxiliary Electrode)

  • 이상익;유재근;전정채;전현재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.85-87
    • /
    • 2007
  • This paper summarize about the auxiliary electrode measured a ground resistance The method to measure a ground resistance is the fall-of-potential method to using an auxiliary electrode. And an auxiliary electrode must be set up on the ground. Today it is so difficult to set up the auxiliary electrode on the ground because of many concrete building and many paved roads. So this paper is regarding of the ground resistance measurement by the substitute auxiliary electrode. It substituted a iron structure around the building, a wire net for auxiliary electrode. This information is confirmed by compared with the measurement value.

  • PDF

고속전철용 보조전력변환장치 1,2군 동시 기동 (Simultaneous operation of two group of Auxiliary Block for Korean High Speed Train)

  • 조현욱;김연충;김태환;장경현;최종묵
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 추계학술대회 논문집
    • /
    • pp.1626-1632
    • /
    • 2007
  • Power Car PC1 and PC2 of Korean high speed train have a auxiliary block which consists of two PWM converter respectively. If a auxiliary block happens a critical failure, the other supplies power to full load of train. In this case, a stability of auxiliary block reduces by a increasing load. For increasing a stability of auxiliary block and train system, a auxiliary block consists of two group four PWM converter which operates simultaneously. If a group of a auxiliary block happens a critical failure, the other supplies power to load of a auxiliary block. This paper describes a method for simultaneous movement of auxiliary block which consists of two group four PWM converter.

  • PDF

추락 방지용 보조로프의 고정 매듭법과 옥외 노출 환경에 따른 강도저하 평가에 관한 연구 (Experimental Study of Strength Degradation according to Fixed Knot Method and Outdoor Exposure Environment of Auxiliary Rope for High Altitude Work)

  • 송상민;김태선;김건엽;김송미;권오헌;박우림
    • 한국안전학회지
    • /
    • 제38권3호
    • /
    • pp.10-19
    • /
    • 2023
  • Fall accidents account for the highest accident fatality rate in the construction industry. In addition, wearing and using a safety belt is the most realistic and important preventive measure to reduce fall accidents. Safety belts are protective devices worn by individual workers; they prevent workers from falling and allow for time to rescue the workers. However, the legal standards for safety belts only stipulate the materials, specifications, and strength of parts; there is no provision for an auxiliary rope fixing method to fix the safety belts safely. Due to this reason, workers in industrial sites arbitrarily fix and use the auxiliary rope. Currently, the most used method to fix the auxiliary rope is to tie a knot, which significantly lowers the strength of the material compared to the standard strength. Moreover, many construction sites are located outdoors, so the strength of the materials used in the auxiliary rope is inevitably reduced due to various external environmental conditions. Therefore, to solve this problem, this study was conducted to evaluate the strength of the material of the auxiliary rope for fixing the safety belt and the knot-tying method for the auxiliary rope. In this study, the exposure conditions for the effects of temperature and moisture were set to reflect the characteristics of the construction industry. The results of this study are expected to be used for standards establishment and the safe use of the auxiliary rope for safety belts in actual field applications.

보조극을 가지는 자동차 시동용 직류 전동기의 특성분석 (Characteristic Analysis of Automotive Starter DC Motor with Auxiliary Pole Core)

  • 하재평;하경호;홍정표;김진구
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권3호
    • /
    • pp.107-115
    • /
    • 2003
  • This paper deals with the effect of the auxiliary pole core in the automotive starter motor on its characteristics. This motor is excited by the permanent magnet and has auxiliary pole core in the stator. The auxiliary pole core is a device to increase the effective flux to obtain the starling torque and prevent the demagnetization of the permanent magnet from the starting current. It Is important to design the auxiliary pore core. And overhang structure causes the electromagnetic phenomenon of 3-dimensional flux Path. Therefore. the characteristic analysis is achieved by the 2-dimensional Finite Element Method (FEM) with the compensated model and the 3-dimensional Equivalent Magnet Circuit Network (3D EMCN). The mechanical loss and the brush and coil resistance are separated from the various experiment of the tested motor, and then these factor are reflected on the analysis results. The validity of the proposed analysis method is verified by comparing the experimental and analysis results. The effects of the design parameters related to the auxiliary pole cote on the motor performance are analyzed by the proposed method.

전류 및 전위 보조전극을 수직으로 배치하는 전위강하법을 이용한 접지저항의 측정 (Measurement of the Ground Resistance using the Fall-of-Potential Method with the Vertically-placed Current and Potential Auxiliary Electrodes)

  • 이복희;김기복;김유하
    • 조명전기설비학회논문지
    • /
    • 제26권3호
    • /
    • pp.53-60
    • /
    • 2012
  • The fall-of-potential method is commonly used in measuring the ground resistance of large-scaled grounding system and the current and potential auxiliary electrodes are horizontally arranged. Because the distances between the ground grid to be tested and auxiliary electrodes are limited in downtown areas, it is very difficult to measure accurately the ground resistance of large-scaled grounding system. In this paper, the fall-of-potential method of measuring the ground resistance with the vertically-placed current and potential auxiliary electrodes was examined and discussed. The validity and good accuracy of the proposed method of measuring the ground resistance were confirmed through various simulations and actual tests carried out in uniform and two-layer soil structures.