• Title/Summary/Keyword: automatic test

Search Result 1,637, Processing Time 0.032 seconds

Automatic UML-based Test Data Generating Tool: AUTEG (UML기반의 테스트 데이타 자동생성 도구 : AUTEG)

  • Kim, Cheong-Ah;Choi, Byoung-Ju
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.8 no.3
    • /
    • pp.268-276
    • /
    • 2002
  • In this paper we suggest a method to produce automatically teat data using UML development diagrams, and analytically describe the application of a tool, Automatic UML-based Test Data Generation (AUTEG) developed using XML technology, to the examples of insurance system. Our AUTEG automatically generates test diagrams that enable to detect errors existing at the interface area between modules composing the whole system, along with test data by applying the existing white-box test technique to the test diagram. Our AUTEG can be applied to the integration test as well as the system test and using the tool, users may make the unit modules of the integration test into several groups.

Development of the Unmanned Automatic Test System for a Portable Detector using TRIZ TESE

  • Chang, YuShin
    • Journal of the Korea Society of Computer and Information
    • /
    • v.26 no.6
    • /
    • pp.63-71
    • /
    • 2021
  • This paper propose an development of the unmanned automatic test system for a portable detector using TRIZ Methodology. A new development scheme among of the unmanned automatic test system configurations was obtained after application of the TESE(Trends of Engineering System Evolution) one of the TRIZ methods. Using Pugh matrix drives some improving ideas. The key idea of this unmanned automatic test system scheme is to minimize whole test procedure time of each portable detector and to maximize the amount of portable detectors at once. Between the before and the after configurations of the 3D mechanical model find out improvements. This paper shows that the proposed development scheme improves the test performance efficiency compared to previous scheme.

Research on the Ammunition Automatic Test Algorithm for Improving Safety & Reliability of 40mm Grenade(K212) Fuze (40mm 고속유탄(K212) 신관의 안전성 및 신뢰성 강화를 위한 탄약 자동화검사 알고리즘에 관한 연구)

  • Ju, Jin-Chun;Kweon, Mee-Sun;Kim, Sang-Min;Ahn, Nam-Su
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.7
    • /
    • pp.14-22
    • /
    • 2016
  • Because fuses have many parts, human error can occur during visual inspections. This paper proposes an automatic ammunition test algorithm for preventing human error during an inspection. The automatic ammunition test algorithm consists of the following three steps. First, the image input and preprocessing step is where an inspection image is rotated using an image rotation algorithm and the image is converted to a binary image. Second, the inspection step of arming determines if the ammunition is armed using Masked Template Matching algorithm, etc. Third, the inspection step of the parts determines if the parts are omitted using an image searching algorithm, etc. The arming or parts omission of the fuse are detected efficiently using the ammunition automatic test algorithm. The ammunition automatic test algorithm is expected to help improve the safety and reliability of 40 mm grenade fuse.

The Fault Tolerant Evaluation Model due to the Periodic Automatic Fault Detection Function of the Safety-critical I&C Systems in the Nuclear Power Plants (원전 안전필수 계측제어시스템의 주기적 자동고장검출기능에 따른 고장허용 평가모델)

  • Hur, Seop;Kim, Dong-Hoon;Choi, Jong-Gyun;Kim, Chang-Hwoi;Lee, Dong-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.7
    • /
    • pp.994-1002
    • /
    • 2013
  • This study suggests a generalized availability and safety evaluation model to evaluate the influences to the system's fault tolerant capabilities depending on automatic fault detection function such as the automatic periodic testings. The conventional evaluation model of automatic fault detection function deals only with the self diagnostics, and supposes that the fault detection coverage of self diagnostics is always constant. But all of the fault detection methods could be degraded. For example, the periodic surveillance test has the potential human errors or test equipment errors, the self diagnostics has the potential degradation of built-in logics, and the automatic periodic testing has the potential degradation of automatic test facilities. The suggested evaluation models have incorporated the loss or erroneous behaviors of the automatic fault detection methods. The availability and the safety of each module of the safety grade platform have been evaluated as they were applied the automatic periodic test methodology and the fault tolerant evaluation models. The availability and safety of the safety grade platform were improved when applied the automatic periodic testing. Especially the fault tolerant capability of the processor module with a weak self-diagnostics and the process parameter input modules were dramatically improved compared to the conventional cases. In addition, as a result of the safety evaluation of the digital reactor protection system, the system safety of the digital parts was improved about 4 times compared to the conventional cases.

Development of Automatic Packing System of One Station for Fasteners(II) : Packing System Manufacture and Performance Test (원 스테이션 파스너 자동포장기 개발(II) : 제작 및 성능검증)

  • Kim, Yong-Seok;Jeong, Chan-Se;Yang, Soon-Young
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.20 no.5
    • /
    • pp.653-658
    • /
    • 2011
  • In general, the purpose of packaging fasteners is a series of management activities to maintain the condition at the time of production until they get delivered to the end user. An automatic packing system for fasteners is consisted of bucket conveyor, slide feeder, vision inspection system, box-magazine conveyor system and automatic packing machine. Also, the automatic packing machine is consisted of six modules including charging device, clamping/opening device, sealing/cutting device, feeding/air-shower device, supplying/adjusting device and device frame, etc. In this paper, we proposed an automatic packing mechanism of the one station concept for packing work of fastener objects where the continuous batch work is performed in a finite space. The proposed one-station packing mechanism has been optimized through mechanical, dynamical, structural and fluid analyses. And it had been manufactured as the prototype of automatic packing machine. The field test for validation of performance was performed directly at the production line of bolt and screw. In the field test, this packing machine showed an efficiency of about 4.5 times the manual operation. It also showed 30% reduction in the consumption of packing materials compared to the manual operation. This automatic packing machine for fastener objects will be commercialized soon.

Automatic Test Report Recording Program Design and Implementation for Integration Test (통합시험을 위한 자동 시험일지 작성프로그램 설계 및 구현)

  • Jeong, Younghwan;Song, Kyoungrok;Lee, Wonsik;Wi, Sounghyouk
    • KIISE Transactions on Computing Practices
    • /
    • v.24 no.1
    • /
    • pp.33-39
    • /
    • 2018
  • For the integration test in the current field of defense simulation, each actual equipment and simulator's logging information is automated. Although the event of the integrated test system is written in the test log, it is not automated, and relies on the operator's handwriting or file creation, resulting in ineffective aspects such as low-quality record content and repetition of the same content. In this study, we propose the automatic test report recording program that solves these problems. Automatic test report recording program uses framework-based technology to receive information from the test control computer and user to record a log of the test log. Automatic test report recording program allows the user to record the repeated test content in a stable manner. Additionally, even if the number of test operators is limited, the efficiency is improved so that we can fucus on the integration test.

A Study on Development of Signal Conditioner for Test of Automatic Control Equipments in Hydro Power Plant (수력발전소 자동제어설비 시험용 신호변환장치 개발에 관한 연구)

  • Byun, Doo-Gyoon;Chang, Moon-Soung;Kim, Ju-Hyeon
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.169-171
    • /
    • 1995
  • Automatic control equipment in hydro power plant, such as turbine governor or automatic voltage regulator have to act promptly against for variation of power system, so it is necessary to check and test continuously. During last five years, the performance test of automatic control equipment was performed about 20 units of hydro turbine generator. In this process, because it has complex connection and before calibration, signal conditioner was developed as an auxiliary equipment for performance test. It includes function of signal amplifier, transducer, and meters. As a result of use this equipment for electric governor test at soyang-gang hydro power plant, it was possible to find output data equal to old one.

  • PDF

ESTIMATION TECHNIQUE Of AIR CONTENT IN TUTOMATIC TRANSMISSION FLUID BY MEASURING EFFECTIVE BULK MODULUS

  • Cho, Baek-Hyun;Lee, Hyoun-Woo;Oh, Jong-Sun
    • International Journal of Automotive Technology
    • /
    • v.3 no.2
    • /
    • pp.57-62
    • /
    • 2002
  • It is well known that the entrained air in oil causes appreciable reduction in the stiffness of hydraulic systems. It makes the response delay of the systems and sometimes destroys the stability. Because the hydraulic systems of automatic transmissions are operated in relatively low pressure and high temperature, it is very important to analyze the effects of the air included in automatic transmission fluid. However, it is difficult to derive the generalized model to describe the effective bulk modulus theoretically or measure it in actual operating conditions of automatic transmissions. This paper reviews previous studies of the air effects in hydraulic systems and the measurement techniques of the effective bulk modulus in operating conditions. Based on this work, the theoretical model with moderate complexity and the measurement technique of the effective bulk modulus considering entrained air effect at real operating conditions are suggested. Our paper also shows that the quantity of the entrained air in the automatic transmission fluid can be estimated from the experimental results.

Development of a Novel System for Measuring Sizing Degree Based on Contact Angle (II) - Reliability and Reproducibility of the New Automatic Measuring System for Contact Angle - (접촉각 측정 원리를 이용한 새로운 사이즈도 측정기 (제2보) -자동 접촉각 측정 시스템의 신뢰성 및 재현성 -)

  • 이찬용;김철환;최경민;박종열;권오철
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.35 no.3
    • /
    • pp.53-58
    • /
    • 2003
  • The newly developed system for measuring a contact angle on a sheet was examined to investigate reliability and reproducibility of the measured results. It was clearly confirmed that the automatic contact angle measuring system was much faster and more reliable way to determine the water resistance of a sheet, comparing with Cobb and Stockigt sizing tests. Cobb test showed less significant results with stringently sized sheets, and Stockigt test exhibited the big deviations by discrepancy of the recognition point of coloring according to different testers in spite of explicit test results. On the other hand, the contact angles measured by the automatic system were reproduced with less deviations, irrespectively of different testers. It was interesting to note that the contact angle might be able to used to predict Cobb and Stockigt sizing degree, based upon the high correlation coefficients of 0.95 and 0.97. Hereafter the automatic system will be upgraded to predict Cobb and stockigt sizing degree through the measurement of contact angle.

Implementation of PXIe platform based portable Automatic Test Equipment to improve reliability

  • Gwon, Hyeok-Jin
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.7
    • /
    • pp.9-16
    • /
    • 2017
  • In this paper, we propose a development method of portable Automatic Test Equipment based on PXIe platform. Legacy VME form factor structured test equipment has limited reuse and expansion of modules due to unapplied bus specification. In particular, these limitations can cause development periods and costs to increase, and the reliability of environmental conditions is lacking due to non-standard modules. The test equipment of the proposed PXIe platform can use diverse COTS modules to shorten the development period and minimize the instability between developments. The PXIe development module works with standard Xilinx FPGAs, PXIe Windows device drivers, and applications on standard PXIe buses. The use of standard bus and COTS modules increases scalability and reusability, enabling rapid development and excellent maintenance. Through the test, we show the proposed test equipments can be implemented efficiently between the development processes and proved their reliability through function tests and environmental tests.