• Title/Summary/Keyword: automatic test

Search Result 1,637, Processing Time 0.034 seconds

Development of an Algorithm for Automatic Finding the Sick or the Dead Layers in the Multi-tier Layer Battery (고단 직립식 산란계 케이지내의 병계 및 폐사계의 유무를 자동 판정하기 위한 영상처리알고리즘 개발)

  • Chang D. I;Lim S. S.;Zheng S. Y.;Lee S. J.
    • Journal of Animal Environmental Science
    • /
    • v.11 no.1
    • /
    • pp.35-44
    • /
    • 2005
  • The objectives of this study were to develop an image processing algorithm for finding the sick or the dead layers(SDL) rearing in the multi-tier layer battery, which is a core technology of remote monitoring systems for layers, and to test the performance of algorithm developed in the experimental poultry housing. Based on the literature study and experiment, the standing up of layer was set as a criterion for judging layers whether sick or dead. Then, by the criterion set, an algorithm was developed. The image processing algorithm developed was tested how well it could and SDL at the experimental poultry housing. Test results showed that its monitoring correctness of layers standing up in the cages having all healthy layers was $92\%$, and $96\%$ in the cages having SDL. Therefore, it would be concluded that the image processing algorithm developed in this study was well suited to the purpose of development.

  • PDF

Research of Usability Test on Disabled Welfare Vehicle for Guardians and Passengers of Disabled People (장애인 보호자 및 탑승자를 대상으로 한 장애인 복지차량 사용성 평가 연구)

  • Rhee, Kun Min;Kim, Dong Ok
    • 재활복지
    • /
    • v.20 no.3
    • /
    • pp.141-161
    • /
    • 2016
  • This research is to anticipate problems of Ray's disabled experiment welfare vehicles for 17 drivers with disability, improving them. In addition it is to provide the criteria for ergonomic design based on perspective of drivers with disability by investigating 18 items of usability test. The results are as follows. First, satisfaction degree of Ray, disabled experiment welfare vehicle, was shown to be 3.88 which is higher than normal vehicles whose degree is 3.20. This showed that the disabled experiment welfare vehicle is the one with much improvement. Second, so as to develop a welfare vehicle it needs to take into account some factors including rear slope, wheelchair locker, seat belt, safety grip, and high roof. Third, in case of rear slope, high roof and width of manual or automatic wheel chairs should be considered and motor-operated device should also be taken into account for safety lockers, which make a wheelchair firmly fixed. Moreover, motor-operated seat and rear slope can be chosen for either of the disabled and the elderly.

Experimental Test Results of Nine Scheduling Operational Modes of PV and Battery Hybrid System for the Development of Automatic Control Algorithm for Continual Operation without being shut-downed (태양광 배터리 Hybrid 전력공급시스템 9가지 운전 모드 시험결과 및 무고장 연속 운전을 위한 자동제어 알고리즘 개발)

  • Song, Taek Ho;Yang, Seung Kwon;Kim, Minjeong
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.5 no.1
    • /
    • pp.25-32
    • /
    • 2019
  • K-BEMS System was introduced to reduce peak load and to save total energy of the 200 buildings that KEPCO headquarter and branch offices use. And K-BEMS system is composed of PV, battery, and hybrid PCS. KEPCO research institute has carried out this K-BEMS research project for 3 years since January 2016. In this paper, the results of the project are shown. 9 modes of test results of K-BEMS system and are operational problems were analyzed. And measures to cure the trouble are also suggested. Batteries are operated more than 20% of SOC, and less than 20% of SOC battery protection switches are automatically shutting down the system and the system no longer respond to EMS, ending the supply of PV, and so therefore to continue the PV power supply it was turn out to be necessary that the EMS should automatically change its policy to change PV only supply mode automatically when the Battery Switch automatically operated. To operate the system continuously and automatically, it is necessary to modify the minimum operational SOC value, and in addition to that the EMS computer must remember the last shut-down SOC and Voltage which interrupted the system and add some margin to reflect the measurement error in the system.

Unmanned Multi-Sensor based Observation System for Frost Detection - Design, Installation and Test Operation (서리 탐지를 위한 '무인 다중센서 기반의 관측 시스템' 고안, 설치 및 시험 운영)

  • Kim, Suhyun;Lee, Seung-Jae;Son, Seungwon;Cho, Sungsik;Jo, Eunsu;Kim, Kyurang
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.24 no.2
    • /
    • pp.95-114
    • /
    • 2022
  • This study presented the possibility of automatic frost observation and the related image data acquisition through the design and installation of a Multiple-sensor based Frost Observation System (MFOS). The MFOS is composed of an RGB camera, a thermal camera and a leaf wetness sensor, and each device performs complementary roles. Through the test operation of the equipment before the occurrence of frost, the voltage value of the leaf wetness sensor increased when maintaining high relative humidity in the case of no precipitation. In the case of Gapyeong- gun, the high relative humidity was maintained due to the surrounding agricultural waterways, so the voltage value increased significantly. In the RGB camera image, leaf wetness sensor and the surface were not observed before sunrise and after sunset, but were observed for the rest of the time. In the case of precipitation, the voltage value of the leaf wetness sensor rapidly increased during the precipitation period and decreased after the precipitation was terminated. In the RGB camera image, the leaf wetness sensor and surface were observed regardless of the precipitation phenomenon, but the thermal camera image was taken due to the precipitation phenomenon, but the leaf wetness sensor and surface were not observed. Through, where actual frost occurred, it was confirmed that the voltage value of leaf wetness sensor was higher than the range corresponding to frost, but frost was observed on the surface and equipment surface by the RGB camera.

Automatic Drawing and Structural Editing of Road Lane Markings for High-Definition Road Maps (정밀도로지도 제작을 위한 도로 노면선 표시의 자동 도화 및 구조화)

  • Choi, In Ha;Kim, Eui Myoung
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.39 no.6
    • /
    • pp.363-369
    • /
    • 2021
  • High-definition road maps are used as the basic infrastructure for autonomous vehicles, so the latest road information must be quickly reflected. However, the current drawing and structural editing process of high-definition road maps are manually performed. In addition, it takes the longest time to generate road lanes, which are the main construction targets. In this study, the point cloud of the road lane markings, in which color types(white, blue, and yellow) were predicted through the PointNet model pre-trained in previous studies, were used as input data. Based on the point cloud, this study proposed a methodology for automatically drawing and structural editing of the layer of road lane markings. To verify the usability of the 3D vector data constructed through the proposed methodology, the accuracy was analyzed according to the quality inspection criteria of high-definition road maps. In the positional accuracy test of the vector data, the RMSE (Root Mean Square Error) for horizontal and vertical errors were within 0.1m to verify suitability. In the structural editing accuracy test of the vector data, the structural editing accuracy of the road lane markings type and kind were 88.235%, respectively, and the usability was verified. Therefore, it was found that the methodology proposed in this study can efficiently construct vector data of road lanes for high-definition road maps.

Comparison of WBCs and RBCs Concordance between the Cobas u 701 Analyzer and Three Manual Microscopy Methods in Urine Sediment (소변 침전물에서 Cobas u 701 Analyzer와 세 가지 수동 현미경검사법의 백혈구와 적혈구의 일치도 비교)

  • Hyeok-Jae LEE;Min-Hyeok LEE
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.55 no.2
    • /
    • pp.82-92
    • /
    • 2023
  • Urine sediments are performed by a microscopic examination of centrifuged urine by medical technologists. This study examined different urine sediment preparation procedures. The 107 fresh urine specimens that tested positive from white blood cells (WBCs) and red blood cells (RBCs) in the urine dipstick test and the cobas u 701 analyzer, respectively, were selected for manual microscopy. This study evaluated an automated urine sediment analyzer and three manual microscopy methods for WBCs and RBCs. The methods were performed according to the test guidelines. The coefficients of determination between the cobas u 701 analyzer and the Korean Association of Quality Assurance for Clinical Laboratory (KAQACL) for WBCs and RBCs were r2=0.977 and r2=0.970, respectively. The concordance rates between the cobas u 701 analyzer and KAQACL for WBCs and RBCs were 74.8% and 77.6%, respectively. A good correlation and concordance with the automatic analyzer were shown when the specimens were prepared and examined using the KAQACL method. Consequently, the differences in the urine sediment preparation procedures affected the sediment concentrations, influencing the cell number per high power field (HPF).

Salient Region Detection Algorithm for Music Video Browsing (뮤직비디오 브라우징을 위한 중요 구간 검출 알고리즘)

  • Kim, Hyoung-Gook;Shin, Dong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.2
    • /
    • pp.112-118
    • /
    • 2009
  • This paper proposes a rapid detection algorithm of a salient region for music video browsing system, which can be applied to mobile device and digital video recorder (DVR). The input music video is decomposed into the music and video tracks. For the music track, the music highlight including musical chorus is detected based on structure analysis using energy-based peak position detection. Using the emotional models generated by SVM-AdaBoost learning algorithm, the music signal of the music videos is classified into one of the predefined emotional classes of the music automatically. For the video track, the face scene including the singer or actor/actress is detected based on a boosted cascade of simple features. Finally, the salient region is generated based on the alignment of boundaries of the music highlight and the visual face scene. First, the users select their favorite music videos from various music videos in the mobile devices or DVR with the information of a music video's emotion and thereafter they can browse the salient region with a length of 30-seconds using the proposed algorithm quickly. A mean opinion score (MOS) test with a database of 200 music videos is conducted to compare the detected salient region with the predefined manual part. The MOS test results show that the detected salient region using the proposed method performed much better than the predefined manual part without audiovisual processing.

Prediction of Pulmonary Function in Patients with Chronic Obstructive Pulmonary Disease: Correlation with Quantitative CT Parameters

  • Hyun Jung Koo;Sang Min Lee;Joon Beom Seo;Sang Min Lee;Namkug Kim;Sang Young Oh;Jae Seung Lee;Yeon-Mok Oh
    • Korean Journal of Radiology
    • /
    • v.20 no.4
    • /
    • pp.683-692
    • /
    • 2019
  • Objective: We aimed to evaluate correlations between computed tomography (CT) parameters and pulmonary function test (PFT) parameters according to disease severity in patients with chronic obstructive pulmonary disease (COPD), and to determine whether CT parameters can be used to predict PFT indices. Materials and Methods: A total of 370 patients with COPD were grouped based on disease severity according to the Global Initiative for Chronic Obstructive Lung Disease (GOLD) I-IV criteria. Emphysema index (EI), air-trapping index, and airway parameters such as the square root of wall area of a hypothetical airway with an internal perimeter of 10 mm (Pi10) were measured using automatic segmentation software. Clinical characteristics including PFT results and quantitative CT parameters according to GOLD criteria were compared using ANOVA. The correlations between CT parameters and PFT indices, including the ratio of forced expiratory volume in one second to forced vital capacity (FEV1/FVC) and FEV1, were assessed. To evaluate whether CT parameters can be used to predict PFT indices, multiple linear regression analyses were performed for all patients, Group 1 (GOLD I and II), and Group 2 (GOLD III and IV). Results: Pulmonary function deteriorated with increase in disease severity according to the GOLD criteria (p < 0.001). Parenchymal attenuation parameters were significantly worse in patients with higher GOLD stages (P < 0.001), and Pi10 was highest for patients with GOLD III (4.41 ± 0.94 mm). Airway parameters were nonlinearly correlated with PFT results, and Pi10 demonstrated mild correlation with FEV1/FVC in patients with GOLD II and III (r = 0.16, p = 0.06 and r = 0.21, p = 0.04, respectively). Parenchymal attenuation parameters, airway parameters, EI, and Pi10 were identified as predictors of FEV1/FVC for the entire study sample and for Group 1 (R2 = 0.38 and 0.22, respectively; p < 0.001). However, only parenchymal attenuation parameter, EI, was identified as a predictor of FEV1/FVC for Group 2 (R2 = 0.37, p < 0.001). Similar results were obtained for FEV1. Conclusion: Airway and parenchymal attenuation parameters are independent predictors of pulmonary function in patients with mild COPD, whereas parenchymal attenuation parameters are dominant independent predictors of pulmonary function in patients with severe COPD.

Myelin Content in Mild Traumatic Brain Injury Patients with Post-Concussion Syndrome: Quantitative Assessment with a Multidynamic Multiecho Sequence

  • Roh-Eul Yoo;Seung Hong Choi;Sung-Won Youn;Moonjung Hwang;Eunkyung Kim;Byung-Mo Oh;Ji Ye Lee;Inpyeong Hwang;Koung Mi Kang;Tae Jin Yun;Ji-hoon Kim;Chul-Ho Sohn
    • Korean Journal of Radiology
    • /
    • v.23 no.2
    • /
    • pp.226-236
    • /
    • 2022
  • Objective: This study aimed to explore the myelin volume change in patients with mild traumatic brain injury (mTBI) with post-concussion syndrome (PCS) using a multidynamic multiecho (MDME) sequence and automatic whole-brain segmentation. Materials and Methods: Forty-one consecutive mTBI patients with PCS and 29 controls, who had undergone MRI including the MDME sequence between October 2016 and April 2018, were included. Myelin volume fraction (MVF) maps were derived from the MDME sequence. After three dimensional T1-based brain segmentation, the average MVF was analyzed at the bilateral cerebral white matter (WM), bilateral cerebral gray matter (GM), corpus callosum, and brainstem. The Mann-Whitney U-test was performed to compare MVF and myelin volume between patients with mTBI and controls. Myelin volume was correlated with neuropsychological test scores using the Spearman rank correlation test. Results: The average MVF at the bilateral cerebral WM was lower in mTBI patients with PCS (median [interquartile range], 25.2% [22.6%-26.4%]) than that in controls (26.8% [25.6%-27.8%]) (p = 0.004). The region-of-interest myelin volume was lower in mTBI patients with PCS than that in controls at the corpus callosum (1.87 cm3 [1.70-2.05 cm3] vs. 2.21 cm3 [1.86-3.46 cm3]; p = 0.003) and brainstem (9.98 cm3 [9.45-11.00 cm3] vs. 11.05 cm3 [10.10-11.53 cm3]; p = 0.015). The total myelin volume was lower in mTBI patients with PCS than that in controls at the corpus callosum (0.45 cm3 [0.39-0.48 cm3] vs. 0.48 cm3 [0.45-0.54 cm3]; p = 0.004) and brainstem (1.45 cm3 [1.28-1.59 cm3] vs. 1.54 cm3 [1.42-1.67 cm3]; p = 0.042). No significant correlation was observed between myelin volume parameters and neuropsychological test scores, except for the total myelin volume at the bilateral cerebral WM and verbal learning test (delayed recall) (r = 0.425; p = 0.048). Conclusion: MVF quantified from the MDME sequence was decreased at the bilateral cerebral WM in mTBI patients with PCS. The total myelin volumes at the corpus callosum and brainstem were decreased in mTBI patients with PCS due to atrophic changes.

A Study of Below Knee Surrounding Dose depends on whether Using Collimator Shielding or not while Percutaneous Coronary Intervention (경피적 관상동맥 중재술 시 차폐 유·무에 따른 슬 하부 주변부 선량에 관한 연구)

  • Park, Jae Jin;Ko, Seong Jin;Kang, Se Sik;Kim, Chang Soo;Kim, Jung Hoon;Kim, Dong Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.5
    • /
    • pp.353-358
    • /
    • 2013
  • Recently, the Percutaneous Coronary Intervention has become a main treatment for treating Coronary because of increase of Circulatory Disease. Because of this reason, the increase of intervention using radiation causes the radiation exposure to workers. Therefore, the latent radiation injury can be increased. Thus, this study/experiment measured around under knee whether using radiation collimator shielding or not. We measured the exposure does by the experiment methods which are using 60kV, 200mA, and 10ms of Automatic exposure conditions and using the major method of the Cinefluography of Coronary in our hospital. As the result of right coronary artery test cases, LAO $30^{\circ}$ when the curtains if you use lead 98.4%, $Cranial30^{\circ}$ 98.3% have a protective effect of the radiation. left circumflex coronary artery test cases, Caudal $30^{\circ}$ if the shielding effect of 90.2%, Caudal $30^{\circ}LAO$ $30^{\circ}$ 88.7% have a protective effect of the radiation. left anterior descending artery test cases, Cranial $30^{\circ}$ 98.3%, Cranial $30^{\circ}RAO$ $30^{\circ}$ 80.3%, Cranial $30^{\circ}$LAO $30^{\circ}$ 98% of the radiation has a protective effect. OS(Spider view) in the case of test Caudal $40^{\circ}LAO$ $40^{\circ}$ 71.2% appeared to have the effect of radiation shielding. For these reasons, radiation workers need to be aware on taking care of their radiation exposure by using the radiation collimator shielding even though it is uncomfortable for them.