• Title/Summary/Keyword: automatic test

Search Result 1,637, Processing Time 0.031 seconds

A Ligthtweight Experimental Frame based on Microservice Architecture (마이크로서비스아키텍처 기반 경량형 모의실험환경)

  • Gyu-Sik Ham;Hyeon-Gi Kim;Jin-Woo Kim;Soo-Young Jang;Eun-Kyung Kim;Chang-beom Choi
    • Journal of IKEEE
    • /
    • v.28 no.2
    • /
    • pp.123-130
    • /
    • 2024
  • As technology advances swiftly and the lifespan of products becomes increasingly short, there is a demand to fasten the pace of research outcomes, product development, and market introduction. As a result, the researchers and developers need a computational experiment environment that enables rapid verification of the experiment and application of research findings. Such an environment must efficiently harness all available computational resources, manage simulations across diverse test scenarios, and support the experimental data collection. This research introduces the design and implementation of an experimental frame based on a microservice architecture. The experimental frame leverages scripts to utilize computing resources optimally, making it more straightforward for users to conduct simulations. It features an experimental frame capable of automatically deploying scenarios to the computing components. This setup allows for the automatic configuration of both the computing environment and experiments based on user-provided scenarios and experimental software, facilitating effortless execution of simulations.

Effects of Expert-Determined Reference Standards in Evaluating the Diagnostic Performance of a Deep Learning Model: A Malignant Lung Nodule Detection Task on Chest Radiographs

  • Jung Eun Huh; Jong Hyuk Lee;Eui Jin Hwang;Chang Min Park
    • Korean Journal of Radiology
    • /
    • v.24 no.2
    • /
    • pp.155-165
    • /
    • 2023
  • Objective: Little is known about the effects of using different expert-determined reference standards when evaluating the performance of deep learning-based automatic detection (DLAD) models and their added value to radiologists. We assessed the concordance of expert-determined standards with a clinical gold standard (herein, pathological confirmation) and the effects of different expert-determined reference standards on the estimates of radiologists' diagnostic performance to detect malignant pulmonary nodules on chest radiographs with and without the assistance of a DLAD model. Materials and Methods: This study included chest radiographs from 50 patients with pathologically proven lung cancer and 50 controls. Five expert-determined standards were constructed using the interpretations of 10 experts: individual judgment by the most experienced expert, majority vote, consensus judgments of two and three experts, and a latent class analysis (LCA) model. In separate reader tests, additional 10 radiologists independently interpreted the radiographs and then assisted with the DLAD model. Their diagnostic performance was estimated using the clinical gold standard and various expert-determined standards as the reference standard, and the results were compared using the t test with Bonferroni correction. Results: The LCA model (sensitivity, 72.6%; specificity, 100%) was most similar to the clinical gold standard. When expert-determined standards were used, the sensitivities of radiologists and DLAD model alone were overestimated, and their specificities were underestimated (all p-values < 0.05). DLAD assistance diminished the overestimation of sensitivity but exaggerated the underestimation of specificity (all p-values < 0.001). The DLAD model improved sensitivity and specificity to a greater extent when using the clinical gold standard than when using the expert-determined standards (all p-values < 0.001), except for sensitivity with the LCA model (p = 0.094). Conclusion: The LCA model was most similar to the clinical gold standard for malignant pulmonary nodule detection on chest radiographs. Expert-determined standards caused bias in measuring the diagnostic performance of the artificial intelligence model.

A Study on the Construction of the Gas Conversion Process System for a Pilot Plant Using a Small-scale Hydrogen Liquefaction System (소규모 수소 액화 시스템을 활용한 파일럿 플랜트의 기체 전환 공정 시스템 구축에 관한 연구)

  • YOUNG MIN SEO;HYUN WOO NOH;TAE HYUNG KOO;ROCK KIL KO;DONG WOO HA
    • Journal of Hydrogen and New Energy
    • /
    • v.35 no.4
    • /
    • pp.353-362
    • /
    • 2024
  • In this study, several studies were conducted on the construction of gas conversion process system for a pilot plant using a small-scale hydrogen liquefaction system. The pilot plant considered in this study includes a liquefier, a storage tank, an evaporator, a gas booster, and a gas storage tank. First, the suspected leak area of the container was checked using the sprayed method of helium gas. The small-scale hydrogen liquefaction system was designed based on the analysis results of the pre-cooling system and the liquefaction system. Additionally, the program was developed to maintain pressure within vessel for an automatic production of liquid hydrogen. The evaporator for liquid hydrogen was manufactured based on the designed analysis data, and the pollution of gas in the vessel was analyzed through a gas recovery line system.

Evaluation for Optimization of CT Dose Reduction Methods in PET/CT (PET/CT 검사 시 CT 피폭선량 감소 방법들의 최적화 평가)

  • Do, Yong Ho;Lee, Hong Jae;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.55-62
    • /
    • 2015
  • Purpose Various methods for reducing radiation exposure have been continuously being developed. The aim of this study is to evaluate effectiveness of dose reduction, image quality and PET SUV changes by applying combination of automatic exposure dose(AEC), automated dose-optimized selection of X-ray tube voltage(CAREkV) and sinogram affirmed iterative reconstruction(SAFIRE) which can be controled by user. Materials and Methods Torso, AAPM CT performance and IEC body phantom images were acquired using biograph mCT64, (Siemens, Germany) PET/CT scanner. Standard CT condition was 120 kV, 40 mAs. Radiation exposure and noise were evaluated by applying AEC, CAREkV(120 kV, 40 mAs) and SAFIRE(120 kV, 25 mAs) with torso phantom compare to standard CT condition. And torso, AAPM and IEC phantom images were acquired with combination of 3 methods in condition of 120 kV, 25 mAs to evaluate radiation exposure, noise, spatial resolution and SUV changes. Results When applying AEC, CTDIvol and DLP were decreased by 50.52% and 50.62% compare to images which is not applying AEC. mAs was increased by 61.5% to compensate image quality according to decreasing 20 kV when applying CAREkV. However, CTDIvol and DLP were decreased by 6.2% and 5.5%. When reference mAs was the lower and strength was the higher, reduction of radiation exposure rate was the bigger. Mean SD and DLP were decreased by 2.2% and 38% when applying SAFIRE even though mAs was decreased by 37.5%(from 40 mAs to 25 mAs). Combination of 3 methods test, SD decreased by 5.17% and there was no significant differences in spatial resolution. And mean SD and DLP were decreased by 6.7% and 36.9% compare to 120 kV, 40 mAs with AEC. For SUV test, there was no statistical differences(P>0.05). Conclusion Combination of 3 methods shows dose reduction effect without degrading image quality and SUV changes. To reduce radiation exposure in PET/CT study, continuous effort is needed by optimizing various dose reduction methods.

  • PDF

Development of Real-Time Vision Aided Navigation Using EO/IR Image Information of Tactical Unmanned Aerial System in GPS Denied Environment (GPS 취약 환경에서 전술급 무인항공기의 주/야간 영상정보를 기반으로 한 실시간 비행체 위치 보정 시스템 개발)

  • Choi, SeungKie;Cho, ShinJe;Kang, SeungMo;Lee, KilTae;Lee, WonKeun;Jeong, GilSun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.6
    • /
    • pp.401-410
    • /
    • 2020
  • In this study, a real-time Tactical UAS position compensation system based on image information developed to compensate for the weakness of location navigation information during GPS signal interference and jamming / spoofing attack is described. The Tactical UAS (KUS-FT) is capable of automatic flight by switching the mode from GPS/INS integrated navigation to DR/AHRS when GPS signal is lost. However, in the case of location navigation, errors accumulate over time due to dead reckoning (DR) using airspeed and azimuth which causes problems such as UAS positioning and data link antenna tracking. To minimize the accumulation of position error, based on the target data of specific region through image sensor, we developed a system that calculates the position using the UAS attitude, EO/IR (Electric Optic/Infra-Red) azimuth and elevation and numerical map data and corrects the calculated position in real-time. In addition, function and performance of the image information based real-time UAS position compensation system has been verified by ground test using GPS simulator and flight test in DR mode.

A Survey on Nurses' Utilization of Computerization in Nursing Practice (간호사의 간호업무 전산화 활용에 대한 조사연구)

  • Rhee, In-Soon
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.5 no.2
    • /
    • pp.209-224
    • /
    • 1999
  • I have practiced this reserch for the purpose of proposition of basic data for amendment and addition of computer system after I surveyed the degree of abilities and satisfaction on the computerization in nursing\ practice. Subjects were collected from September 1 to September 30, 1998. Study subjects are 151 clinical nurses who are working at university hospital in Chonbuk area. Study instrument consists of 116 questionnaire which was developed by Kim H. K(1998). The data were analized number, mean ,t-test, ANOVA by using SPSS. The study results are as follows: 1. Most of the nurses who answered the questions were educated computerizing(96%). The abilities of computer program utilities were the most in inputting data(74%). The program nurses wanted computerizing education was wordprocess, dealing internet and statistics. 2. As for applying parts of computer system in nursing, the most nurses were Dr's order check (96%), treatment activity(91.4%), medication(89.4%), lab. test(87 .4%), transfering department(85.4%), transfering room(79.5%), diet(71.8%), discharge (70.2%), Barcord Sticker(70.2%) , reservation(62.2%) in order that were all conected order system mutually to other part. It showed that computer system was not applied for treating the original nursing work such as nursing record (13%), duty scheduling(6.0%) , nursing process(4.6%) , Q.I(1.3%), nursing research(1.3%), education(1.3%), 3. As for the benefit when computer system is applied for, the most respondence was promptness of work and convenience(90.6%) , exactness of work (82.8%), offering information exactily and efficiently(36.3%), offering good quality of nursing (6.0%) in order. 4. The degree of contentment on computerizing in nursing practice showed average 3.24%. The best marking item is that they are eager to participate in the computer education. Next, the automatic output of label and giving the number automatically is to prevent loss and mentioned items of patient registration from being changed(3.95) and to prevent mistakes possibly happening because of doctor's difficult order(3.85). 5. The problems which may happen to in nurses' utilization of computerization for the nursing practice showed average 3.18. The most problem is that the practice may stop because of the problem of computer itself(3.67), and the next, the indication of act can be imperfect(3.66) , manual training may overlap because of incomplete computerization (3.60), practical education for the computerizing is lack(3.41), and the computer literate nurses are lack(3.40) . 6. Study subject's contentment by age was significant difference(F=3.10,P=0.0119). Study subject's contentment by job posision was significant difference(F=6.001P=0.0034) I will propose the following according to the above results. The domain of original nursing practice is urgernt. Manual and indication of act should be made before long in computer obstacle. Nursing department should support the nurses so that they could receive the education needed for the nurses themselves.

  • PDF

An Accuracy Evaluation of Algorithm for Shoreline Change by using RTK-GPS (RTK-GPS를 이용한 해안선 변화 자동추출 알고리즘의 정확도 평가)

  • Lee, Jae One;Kim, Yong Suk;Lee, In Su
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.1D
    • /
    • pp.81-88
    • /
    • 2012
  • This present research was carried out by dividing two parts; field surveying and data processing, in order to analyze changed patterns of a shoreline. Firstly, the shoreline information measured by the precise GPS positioning during long duration was collected. Secondly, the algorithm for detecting an auto boundary with regards to the changed shoreline with multi-image data was developed. Then, a comparative research was conducted. Haeundae beach which is one of the most famous ones in Korea was selected as a test site. RTK-GPS surveying had been performed overall eight times from September 2005 to September 2009. The filed test by aerial Lidar was conducted twice on December 2006 and March 2009 respectively. As a result estimated from both sensors, there is a slight difference. The average length of shoreline analyzed by RTK-GPS is approximately 1,364.6 m, while one from aerial Lidar is about 1,402.5 m. In this investigation, the specific algorithm for detecting the shoreline detection was developed by Visual C++ MFC (Microsoft Foundation Class). The analysis result estimated by aerial photo and satellite image was 1,391.0 m. The level of reliability was 98.1% for auto boundary detection when it compared with real surveying data.

Development of the Automatic Fishing System for the Anchovy Scoop nets (I) - The hydraulic winder device for the boom control - (멸치초망 어업의 조업자동화 시스템 개발 (I) -챗대 조작용 유압 권양기 개발-)

  • 박성욱;배봉성;서두옥
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.36 no.3
    • /
    • pp.166-174
    • /
    • 2000
  • Anchovy, EngrauEis japonica scoop nets are used in the coastal of Southern and Cheju of Korea. Especially in the Cheju, the fishing gear of scoop nets consists of upper boom, lower boom, pressing stick and bag net. They are operated by fishing boats of 6 to 10 ton class and 8 persons on board. The booms are controlled by side drum, and the net and pressing stick are hauled by only human power in operating. Therefore this fishery needs to large labor and heavy human power and has much risk. Three kinds of hydraulic winding device which controls two booms was designed and manufactured to reduce heavy labor force of scoop nets, and trial in the sea was carried out to test their performances using the commercial fishing boats of 6 ton class. The proper capacity of hydraulic pump and motor were determined by model test of boom 1/5 scale. The results obtained are as follows, 1. Tension of boom which is being drawn was the strongest and 187.5kgf when the boom's end is in the depth of 4m under the water. 2. The hydraulic motor of the fittest kind of winder has the least leakage per time than the other kinds. 3. In the best type of several winder devices, when the pressure difference was fixed $130kg/^2$ for the safe fishery, the winding velocity of boom line was 2m/sec, is faster 0.48/sec than traditional fishing method and this winder can catch the anchovy of 1.6 tonnage. 4. As a result, the crew were decreased from 8 to 6 and the problem of heavy human power and risk on fishing operation were solved by using the this winder.

  • PDF

Experimental Study on Steel Beam with Embossment Web (엠보싱 웨브를 가지는 보 부재의 실험적 연구)

  • Park, Han-Min;Lee, Hee-Du;Shin, Kyung-Jae;Lee, Swoo-Heon;Chae, Il Soo
    • Journal of Korean Society of Steel Construction
    • /
    • v.29 no.6
    • /
    • pp.479-486
    • /
    • 2017
  • Steel beams with corrugated web have been widely used in the steel structures. However, it is challenging to weld the section between the corrugated web and the flange straight, which increases the cost of production. In order to solve this issue, steel beam with intaglio and embossed web (It is called an IEB) was invented. A web with embossment is produced by cold pressing and welded to flange by automatic welding machine. The loading tests were conducted to investigate the load-carrying capacity of IEB, and its test result was compared with that of H-shaped beam having a same size of flange and web. The test results of IEB series showed about 40% higher load capacities than H-shaped series. As a result of comparing the IEB specimen with Eurocodes for steel beams with corrugated web, all of specimens tested in this study did not meet the design value. Therefore, it is difficult to apply existing formula to IEB and new design formula should be presented for field application.

Effect of the Hopper of the Plug Transplanter and Moisture Content, Compaction Method, and Initial Irrigation of the Soil on the Seedling Survival rate at Transplant of Plug Seedling (플러그묘 정식시 정식기의 호퍼 크기, 토양수분, 초기관수량 및 진압방법이 작물에 미치는 영향)

  • 문성동;민영봉;박중춘
    • Journal of Bio-Environment Control
    • /
    • v.6 no.4
    • /
    • pp.258-263
    • /
    • 1997
  • The result was summarized of basic test and field test to find what quantity of irrigation, what state of compaction and what size of transplanting hopper could induce the optimum taking root in the transplantation of plug seedling by transplanters, and thus acquired the basic data for the development of the related transplanters and the optimum growth and development control. Livability of vegetables after transplanting had no significant difference with respect to for the size of hopper, but was greatly affected by the length of seedlings. The longest possible length of seedling for transplanting and optimal length were found to be 30cm and 28cm, respectively. For irrigation when transplanting red pepper or Chinese cabbage it was thought that large-sized hopper was appropriate. The livability of plug seedling 10 days after transplantation was mainly affected by soil moisture content. Consequently it was thought no irrigation would be needed when transplanting at the soil moisture content of more than 18% ; irrigation of more than 50cc would be needed at the soil moisture content of 13% : initial irrigation of more than 100cc and subsequent irrigation would be needed at the soil moisture content of less than 3.8%. The improvement of soil compaction method (left and right side compaction) with conventional semi-automatic transplanter was not necessary, since there was no difference in livability depending on the compaction methods, left-right side compaction or back-forth-left-right side compaction.

  • PDF