• Title/Summary/Keyword: automatic test

Search Result 1,637, Processing Time 0.031 seconds

BIM Automatic Design and the Optimization of the Tunnel Blasting Patterns (터널 발파패턴 최적화를 위한 BIM 설계자동화)

  • Eunji Jo;Woojin Kim;Jaeho Jung;Sanghyuk Bang
    • Tunnel and Underground Space
    • /
    • v.34 no.5
    • /
    • pp.461-476
    • /
    • 2024
  • As the paradigm of urban development has recently changed to development of underground space, the road tunnels and railway tunnels are increasing to relieve traffic congestion. This technical notes is related to the development of underground spaces using NATM (New Austrian Tunneling Method). Limitations of conventional 2D blasting pattern design method were analyzed, and BIM-based automatic design method was developed to overcome them. Since it was developed to facilitate modeling of all safety facilities along a alignment using coordinates and GIS data, it can overcome the limitations of the number of safety facilities that can be considered and time required for conventional design. In the conventional design, the results of borehole test blasting were used to predict the blasting impact. However, the developed technology is possible to recalculate by applying the measurement results obtained from actual tunnel blasting, enabling rapid re-evaluation of the blasting impact on all safety facilities during construction, leading economical design. As a result of applying it to GTX-A5 and 6 sites, it took about 5 minutes, which is 1/480 compared to the conventional design method. In addition, the construction cost was reduced by about 8 billion won/km and the period was reduced by about 41 days/km. It is expected to be used as technical basis for calculating the optimal blasting pattern in the BIM-based design and construction management process.

Comparison of Batch Assay and Random Assay Using Automatic Dispenser in Radioimmunoassay (핵의학 체외 검사에서 자동분주기를 이용한 Random Assay 가능성평가)

  • Moon, Seung-Hwan;Lee, Ho-Young;Shin, Sun-Young;Min, Gyeong-Sun;Lee, Hyun-Joo;Jang, Su-Jin;Kang, Ji-Yeon;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.4
    • /
    • pp.323-329
    • /
    • 2009
  • Purpose: Radioimmunoassay (RIA) was usually performed by the batch assay. To improve the efficiency of RIA without increase of the cost and time, random assay could be a choice. We investigated the possibility of the random assay using automatic dispenser by assessing the agreement between batch assay and random assay. Materials and Methods: The experiments were performed with four items; Triiodothyronine (T3), free thyroxine (fT4), Prostate specific antigen (PSA), Carcinoembryonic antigen (CEA). In each item, the sera of twenty patients, the standard, and the control samples were used. The measurements were done 4 times with 3 hour time intervals by random assay and batch assay. The coefficient of variation (CV) of the standard samples and patients' data in T3, fT4, PSA, and CEA were assessed. ICC (Intraclass correlation coefficient) and coefficient of correlation were measured to assessing the agreement between two methods. Results: The CVs (%) of T3, fT4, PSA, and CEA measured by batch assay were 3.2$\pm$1.7%, 3.9$\pm$2.1%, 7.1$\pm$6.2%, 11.2$\pm$7.2%. The CVs by random assay were 2.1$\pm$1.7%, 4.8$\pm$3.1%, 3.6$\pm$4.8%, and 7.4$\pm$6.2%. The ICC between the batch assay and random assay were 0.9968 (T3), 0.9973 (fT4), 0.9996 (PSA), and 0.9901 (CEA). The coefficient of correlation between the batch assay and random assay were 0.9924(T3), 0.9974 (fT4), 0.9994 (PSA), and 0.9989 (CEA) (p<0.05). Conclusion: The results of random assay showed strong agreement with the batch assay in a day. These results suggest that random assay using automatic dispenser could be used in radioimmunoassay.

Analysis of Residual Solvents of [F-18]FDG Using Gas Chromatography (기체크로마토그래프법을 이용한 [F-18]FDG의 잔류용매 분석)

  • Kim, Dong-Il;Lee, Il-Jung;Kim, Shi-Hwal;Chi, Yong-Gi;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.26-29
    • /
    • 2011
  • Purpose: The general test method of the Korean Pharmacopeia specifies the test method on the clauses of quality control after manufacturing. According to KFDA Guidance for Medicines, standards of residual solvents regulates the maximum permissible dose of acetonitrile as 400 ppm, ethanol as 5,000 ppm, and acetic acid as 5,000 ppm. This study aims at identifying the type of resiual solvents in the final [F-18]FDG vial of an automatic synthesizer and measure its residual quantity. Materials and Methods: The center carried out residual solvents test of [F-18]FDG injection using Agilent Technologies 7890A with a Flame Ionization Detector. The column of Agilent Technologies 7890A used in measuring of residual solvents was CP WAX column ($30m{\times}0.53mm{\times}1.0{\mu}m$) and analysis condition was split mode 1:1 at the initial temperature $70^{\circ}C$ which was increased $20^{\circ}C/minute$ after two minutes and maintained at the final $140^{\circ}C$ for two minutes. The analysis method was as following: Firstly, ethanol-acetonitrile-acetic acid mixture was classified into four types of concentration (250-25-250 ppm, 1,000-100-1,000 ppm, 3,000-300-3,000 ppm, and 6,000-600-6,000 ppm), and $1.0{\mu}L$ of each type of concentration was injected into gas chromatography followed by an analysis of its peak domain. Then, a calibration-curve by the external standard method was drawn based on the analysis result. Results: While ethanol and acetonitrile were detected in TRACERlab MX, FASTlab had additional acetic acid. The residual quantity of the ethanol-acetonitrile-acetic acid mixture evaluated using the calibration-curve was average 72 ppm ethanol, 54 ppm acetonitrile, and 1030 ppm acetic acid for FASTlab, whereas average 439 ppm ethanol and 79 ppm acetonitrile for TRACERlab MX. This indicated that both of them were within the maximum permissible dose. Conclusion: Solvent residues in the [F-18]FDG injection were all within maximum permissible doses and proper to be used to examine a patient. The result indicated that types and quantities of solvent resides of radioactive pharmaceuticals vary depending on the automatic synthesizer.

  • PDF

A Study of the Effect, Safety and Saving Expense by Reusing Hemodialyzer (재사용(再使用) 투석기(透析器)의 효과(效果) ${\cdot}$ 안정성(安定性) 및 비용절감(費用節減)에 관한 연구(硏究))

  • Jung, Ha-Chung
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.3 no.1
    • /
    • pp.93-106
    • /
    • 1997
  • By the increase of the rate of existence of the hemodialyzing patients, they were required the long run treatment. Regardless of medical insurance expansion, hemodialyzing cost much expenses so that hospital has been considering the reuse of hemodialyzer and flowing euqipments along with the diverse study and progress of the ways of hemodialyzing and medical instruments. This study was aimed to provide the basic materials regarding the reuse of hemodialyzer which is used for the patients of chronic renal disease. The reusing program in the artificial kidney center of K hospital has been used for this study from 50 patients aften one year result from Sep. 1995 through Aug. 1996. Automatic equipment of DRS-4 made by Seratronic Co., was used as the equipment and it was retreated with the function test simultaneously. Compliaction and confirmation of the infection were by the records of the hemodialysis of the patients. SPSS was used for the analysis of the materials by computerization. The character of the patients and the rate of removal was by mistake and percentage, function test and rate of complication by Ftest(ANOVA) and the rate of complication per items by ${\chi}^2$ and Ftest. As the post test the Duncan's test was used for the statistically significant different variables in the standard of p<.05 after Ftest. The followings are the summary of the result : 1) In the function test of the new hemodialyzer and the reused one, and in all of CA110 and CF15.11, the dialyzer ultrafiltration coeffient(KUf) was appeared to have been higher in the reusing groups than the first use ones. This has been the normal limit showing no troubles with them. 2) In the function test of the new and reused hemodialyzer, in all of CA110 and CF15.11, the total blood volume was appeared to have been the less value in the reuse groups than the new ones. This was the price within 80% of the first price that both showed possible for use. 3) The result of reuse hemodialyzer of CA110 was $29.48{\pm}7.83$ in average in the test of leak test while $17.3{\pm}7.96$ in reuse of CF15.11. The normal limit of <60 was the leak test result. So both of the hemodialyzer was normal for reuse. 4) The rate of removal of Blood Urea Nitrogen(BUN) was 72.25% in CA110 hemodialyzer by reusing 16-20 times as the highest rate showing the better result in the reuse hemodialyzer, while in CF15.11 hemodialyzer showed 71.16% by highest rate in the first use by the highest rate with no difference from the reuse. 5) The rate of removal of serum creatinine of CA110 was 64.08% by highest rate in reuse of 1-5 times by showing better result in reuse hemodialyzer. While in CF15.11 66.47% the highest by reuse of 16-20 times showing no difference from each other. 6) No patients were admitted or precribed by antibiotics in relation with reuse dialyzer and no reports were shown about hepatitis $B{\cdot}C$. AIDS in fection. 7) Of the total 248 episods of complication due to the hemodialyzing, 86 by first use, 73 by 1-5 times, 35 by 6-10 times, 35 by 11-15 times and 19 by 16-20 times have been shown which have had no significant difference between the groups. 8) In the comparison of the expense for the hemodialyzer, there was the effect of saving 11,597.6 Won between the first and reuse hemodialyzer. And by decreasing the extracted materials, they did the great role of disposing the waste matters.

  • PDF

Instantaneous Compliance and Creep Compliance functions of Early-Age Concrete under Quasi-Instantaneous Loading (준-순간 하중에 의한 초기재령 콘크리트의 순간 및 크리프 컴플라이언스 함수)

  • Oh Byung-Hwan;Choi Seong-Cheol;Park Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.1 s.85
    • /
    • pp.11-18
    • /
    • 2005
  • In order to accurately assess the stresses occurring in the early-age concrete, a compliance function which can consider the characteristics of early-age concrete is required. Existing compliance functions, however, have the limit that they have been deduced from the data of hardened concrete and therefore, do not take into account the fast development of material properties in early-age concrete. Furthermore, the distinction between instantaneous compliance and creep compliance is not clear in the existing experimental method. The purpose of present study is to propose a compliance function which can describe the rapid change of hardening processes in early-age concrete. To this end, a test method which can estimate the instantaneous compliance without creep effects in the early-age concrete was suggested first. Based on the suggested experimental method, tests on the instantaneous as well as creep compliance were performed using MTS automatic servo-loop test machine. The test results showed that both instantaneous and aging viscoelastic compliance, which are constants in B3 model, were functions in terms of age of concrete especially at early ages. Therefore, the modified compliance function based on B3 model was proposed to provide more realistic prediction on the behavior of early-age concrete. It is expected that the present model allows more realistic evaluation of varying stresses in concrete structures at early ages.

Development and its Effects of Contents for Blended Learning in Public Practical Center of Technical High School, Busan City (부산광역시 공업계 고등학교 공동 실습소에서 혼합형 학습을 위한 컨텐츠의 개발 및 적용)

  • Park, Jae-Taek;Lee, Sang-Hyuk
    • 대한공업교육학회지
    • /
    • v.32 no.1
    • /
    • pp.93-116
    • /
    • 2007
  • The purpose of this study was to improve the academic achievement at the public practical center of technical high school in Busan. For this study, 1 class(31 students) in the second grade at "B"technical high school were selected and these students were divided into two groups. One is the experiment group which blended learning was applied to and the other is control group which traditional lecture method was applied to. Each group was divided into three sub-groups by the level of learning ability. Non-randomized control-group pretest-posttest design was applied for this experiment planning. The subject of experiment was the unit of "3D Modeling and Making NC code" in the textbook of "Application of Automatic System" applied by the public practical center of technical high school in Busan. On-line contents were developed and applied to the blended learning to control group. In order to analyze the test result, t-test with a significance level of 0.05 was carried out using SPSS 10.0. The results of this study was summarized as follows; First, as a result of the post test performed on the experiment and the control group, there was a significant difference between two groups, that was, the blended learning was more effective than the traditional lecture method in improving academic achievement. Second, blended learning was more effective than the traditional lecture method in the group of high-leveled and middle-leveled, but was little effective on the low-leveled group. Third, blended learning was more effective than the traditional lecture method in the functional domain, but was little effective in the cognitive domain and psychomotor domain.

Decision Algorithm of Natural Algae Coagulant Dose to Control Algae from the Influent of Water Works (정수장 유입조류 전처리를 위한 천연조류제거제(W.H.)의 최적주입농도 결정)

  • Jang, Yeo-Ju;Jung, Jin-Hong;Lim, Hyun-Man;Yoon, Young H.;Ahn, Kwang-Ho;Chang, Hyang-Youn;Kim, Weon-Jae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.9
    • /
    • pp.482-496
    • /
    • 2016
  • Algal blooms of cyanobacteria (blue-green Algae) due to the eutrophication of rivers and lakes can cause not only the damage by its biological toxins but also the economic loss in drinking water treatment. The natural algae coagulant, a commercial product known as W.H. containing the algicidal and allelopathic material derived from oak, can control algal problems proactively through the coagulation flotation process. However, because there have been no applications of the process for pre-treatment in drinking water plants, we could find no report on the optimum injection dose of W.H.. In this study, we have conducted several sets of jar-tests while changing W.H. dose and concentration of chl-a for (1) Han-river samples and (2) subcultured cyanobacteria samples, and monitored the removal mechanisms of algae intensively. Based on these jar-test results, two linear equations with variables of chl-a and turbidity have been deduced to predict the optimal W.H. dose after the multiple regression analysis using IBM-SPSS. Also, prototypes of automatic control logic have been suggested to inject the optimal W.H. dose promptly in response to the variation of water quality.

MBTI Personality Types of the University Students in an Area (일 지역 대학생의 성격유형)

  • Jang, Hyun-Jung
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.3
    • /
    • pp.486-498
    • /
    • 2018
  • This study is a descriptive research study conducted to provide useful preliminary data that is helpful for self-initiated learning through a preference trend-based learning method by analyzing the personality types of university students in an area. In this study, the self-administered MBTI form $M^{(R)}$ test was performed on 695 students of 10 departments at K University, from September 18 to 22, 2017, using an automatic scoring system. Collected data was analyzed with descriptive statistics and Chi-square test, using the SPSS Win 22.0 Program, to sort the target students into one of 16 different personality types and examine psychological function and temperament by their personality. Differences in personality type preference by gender were as follows: for judging function, the male students had a strong preference for the T type (thinking type) while the female students showed a high preference for the F type (feeling type), and in the case of the pattern of behavior and lifestyle, the male students and the female students had a strong preference for the P type (perceiving type) and the J type (judging type), respectively. In addition, there were significant differences for each major and each department in personality type, psychological function and temperament. In conclusion, personality type was found to vary by gender, major and department. It would be necessary to develop a manual for learning methods reflecting individual preference.

Urban Area Building Reconstruction Using High Resolution SAR Image (고해상도 SAR 영상을 이용한 도심지 건물 재구성)

  • Kang, Ah-Reum;Lee, Seung-Kuk;Kim, Sang-Wan
    • Korean Journal of Remote Sensing
    • /
    • v.29 no.4
    • /
    • pp.361-373
    • /
    • 2013
  • The monitoring of urban area, target detection and building reconstruction have been actively studied and investigated since high resolution X-band SAR images could be acquired by airborne and/or satellite SAR systems. This paper describes an efficient approach to reconstruct artificial structures (e.g. apartment, building and house) in urban area using high resolution X-band SAR images. Building footprint was first extracted from 1:25,000 digital topographic map and then a corner line of building was detected by an automatic detecting algorithm. With SAR amplitude images, an initial building height was calculated by the length of layover estimated using KS-test (Kolmogorov-Smirnov test) from the corner line. The interferometric SAR phases were simulated depending on SAR geometry and changable building heights ranging from -10 m to +10 m of the initial building height. With an interferogram from real SAR data set, the simulation results were compared using the method of the phase consistency. One of results can be finally defined as the reconstructed building height. The developed algorithm was applied to repeat-pass TerraSAR-X spotlight mode data set over an apartment complex in Daejeon city, Korea. The final building heights were validated against reference heights extracted from LiDAR DSM, with an RMSE (Root Mean Square Error) of about 1~2m.

A Comparative Study on Productivity Analysis of Automated Pavement Crack Sealing Machines (도로면 크랙실링 자동화 장비의 작업 생산성 분석에 관한 비교 연구)

  • Seo, Won-Jung;Yoo, Hyun-Seok;Kim, Young-Suk
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.4
    • /
    • pp.1289-1298
    • /
    • 2014
  • Pavement crack sealing method, which is one of the methods to maintain and repair the road, prevents the extending of cracks by repairing cracks in its early occurrence and has already been applied to many roadworks in advanced foreign country for a long time. But in the conventional crack sealing method, traffic accidents occur frequently during the repair because it's commonly performed on the heavy traffic road or highway. It also has some difficulties in securing the safety of workers from the risk of burns caused by heated sealant. In an effort to solve these problems, automated pavement crack sealing machines such as ARMM, OCCSM, TTLS have been developed in advanced foreign country since early 1990s. Also APCS in 2004 and ACSTM in 2013 were already developed domestically. However, since these automated crack sealers developed from a number of research institutions have different test-bed conditions and productivity measurement models, it's difficult to compare and evaluate them objectively. In this study, the image processing time of the respective machines and the movement time of each motion on the work process were estimated by using fully autonomous mapping and semi-automatic mapping in order to measure the productivity in the same environmental conditions. In addition, the productivity measurement test-bed reflected domestic road characteristics was designed to estimate and compare the productivity of the automated crack sealing machines.