• Title/Summary/Keyword: automatic size measurement

Search Result 79, Processing Time 0.028 seconds

A Study on the Relationship with Acupuncture Stimulation and Stress -Using Pupil Size Variability(PSV)- (동공크기변이도를 통한 침자극과 스트레스의 상관관계 연구)

  • Choi, Woo-Jin;Hu, Yong-Suk;Park, Kyung-Mo;Kim, Ji-Eun;Lee, Seung-Gi
    • Journal of Oriental Neuropsychiatry
    • /
    • v.16 no.2
    • /
    • pp.113-124
    • /
    • 2005
  • Objectives : The purpose of this case-control research was to investigate the effects of acupuncture stimulation on autonomic nervous system for patients with PSV and to find out relationship with anti-stress effects. Methods : The study group consists of 24 patients with self-recognition of stress as the case group, and 20 normal person as the control group by similar age. We measured PSV of case and control groups before acupuncture stimulation, prick acupuncture in Hegu(LI4), Taichong(Liv3), Shenme(H7), Neiguan(P6), Zusanli(S36). After treating for 20 minutes, measurement values of PSV were compared for pre-acupuncture and post-acupuncture Results : 1. Pupil size of the case group were decreased significantly after acupuncture stimulation in the 1st 2nd experiments. Pupil size of the control group was decreased significantly after acupuncture stimulation in the 1st experiment. 2. Pupil size of the case group were decreased significantly between the 1st and 2nd experiments before acupuncture stimulation. Conclusion : The results suggest that acupuncture stimulation is associated with changed activity in the sympathetic and parasympathetic nervous system. Measurement values of PSV is suitable to estimate the activity of automatic nervous system.

  • PDF

A Basic Study on Efficient Acrylic Plate Light Transmission Road Machining (효율적인 아크릴판 광전송로 가공에 관한 기초 연구)

  • Han, Su-Won;Hong, Jun-Hee
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.1
    • /
    • pp.95-101
    • /
    • 2022
  • This paper proposes a method to process the shape of an optical transmission road and attempts to determine the most suitable single processing method for an acrylic plate optical transmission road. In addition, by manufacturing an automatic pattern processing device to generate certain shapes on the acrylic plate at regular intervals, and measuring the illuminance of the patterned acrylic plate optical transmission road, the measured illuminance was confirmed to fall under the KS illuminance values presented in Table 1. In conclusion, when an incident light of approximately 20,000 lx is applied, the transmission illumination is approximately 200 lx, which represents a transmission rate of approximately 1% for incident light and corresponds to the KS illumination criterion F. Additionally, the right-angle triangular pyramid base size (A) processed at a temperature of 350 ℃ for one second was 2 mm, exhibiting the largest transmission illumination of 280 lx. When the transparent acrylic plate was set to a constant size of 1.6 mm at the bottom of the right-angle triangular pyramid, the fastest response occurred at a processing tip temperature of 350 ℃ (0.04 s). On the other hand, it took 10 s to process the size of the bottom of the right-angled triangular pyramid at a temperature of 200 ℃ to 1.6 mm, and it was confirmed that the optical transmission efficiency was significantly reduced because of the burr that occurred at this time.

Implementation of Hydrological Survey Scheduling using Real-Time Water Level Information (실시간 수위정보를 활용한 수문조사 스케줄링 구현)

  • Jae Myeong Choi
    • Journal of Platform Technology
    • /
    • v.11 no.2
    • /
    • pp.66-75
    • /
    • 2023
  • Hydrological survey measurement technology has improved due to the introduction of high-tech equipment and advances in technology, but hydrological survey still requires a lot of manpower and time, and the manpower invested is very limited compared to the size and scope of work. In addition, although automatic flow measurement facilities are in operation, it is difficult to expand them nationwide due to limited field conditions. Therefore, it is necessary to improve the operating infrastructure and environment rather than the measurement technology itself for hydrological investigation. In addition, in terms of flow investigation, it is necessary to schedule an investigation using real-time water level information in order to inventory the accuracy of the water-flow relationship equation and improve work efficiency. Therefore, in this paper, research related to domestic hydrological surveys was analyzed and a hydrological survey scheduling system using real- time water level information based on Open API was implemented to increase the economic and efficiency of hydrological surveys.

  • PDF

Development and Evaluation of High Speed weigh-in-motion system (고속축하중측정시스템의 개발과 평가)

  • Kim, Ju-Hyun
    • International Journal of Highway Engineering
    • /
    • v.12 no.3
    • /
    • pp.17-26
    • /
    • 2010
  • Maintenance of the roads and bridges is a major issue for all road administrators around the world, and various initiatives are being implemented in each region for the purpose of controlling the ever increasing road maintenance cost while ensuring the safety of the vehicles driving. Efforts for such initiatives have also been made in Asia and initiatives for managing heavy-weight vehicles have recently gained momentum in Korea and Japan. We have developed a technology for unevenly installing bar-shaped sensors (piezo quartz sensors) to enable dynamic axle load measurement at a highly accurate level, and have estimated our measurement accuracy of axle load/gross weight, etc. on an actual road. The measurement accuracy of the axle load/gross weight varies significantly depending on the number of sensors installed. In our implementation, the target accuracy was set to below ${\pm}5%$ for gross weight measurement so that automatic regulation can be applied. We have achieved our target by installing 8-point measurement system. However, to have this technology widely accepted, it was necessary to reduce the system size so that it can be easily implemented. Therefore, we have estimated the relationship between the measurement accuracy and the system size (number of measurement points), and have come up with the proposal of 3-point measurement as an optimum number of measurement points, and have estimated its performance on an actual road. Additionally, we evaluated the relationship between the measurement accuracy and vehicle velocity.

The Effects of Acupuncture Stimulation and Progressive Relaxation Therapy on Examination Stress of Students -Using Heart Rate Variability and Pupil Size Variability - (침자극과 이완요법이 시험 스트레스에 미치는 영향 - 심박변이도와 동공크기변이도를 사용하여 -)

  • Kwak, Sun;Lee, Seung-Gi;Park, Kyung-Mo;Choi, Woo-Jin
    • Korean Journal of Acupuncture
    • /
    • v.21 no.2
    • /
    • pp.161-176
    • /
    • 2004
  • Objectives : The purpose of this study was to investigate the effects of acupuncture stimulation and relaxation therapy on autonomic nervous system for students with examination stress by HRV, PSV and to find out relationship with anti-stress effect. Methods : The study group consists of 42 students were classified into three groups randomly : acupuncture stimulation group(male n=8, female n=6), relaxation therapy group(male n=8, female n=6) and rest group(male n=8, female n=6). Using heart rate variability and pupil size variability, we measured the value of HRT, SDNN, SDSD, LF norm, HF norm, LF/HF ratio, Pupil area, and compared the changes the sympathetic- parasympathetic activity. Measurement value were compared before and after, during midterm examination and normal times. Results : 1. HRT, LF/HF ratio, LF norm of acupuncture group was significantly decreased and HF norm were significantly increased in HRV after acupuncture stimulation at a term of examination. While variables of the other group were no significantly different. 2. SDNN of acupuncture group were significantly increased in HRV after acupuncture stimulation at normal times. 3. Pupil area, LF norm, HF norm of three group were no significantly different in PSV at a term of examination. 4. Pupil area of relaxation group were significantly decreased in PSV at normal times. While variables of the other group were no significantly different. 5. HRT of rest group were significantly decreased in HRV between three groups at a term of examination and normal times. 6. Pupil area of relaxation group were significantly decreased in PSV between three groups at a term of examination and normal times. Conclusion : The results suggest that acupuncture stimulation is associated with changed activity in the sympathetic and parasympathetic nervous system. Measurement values of HRV and PSV are suitable to estimate the activity of automatic nervous system.

  • PDF

Classification of Torso Shapes of Men Aged 40-64 - Based on Measurements Extracted from the 8th Size Korea Scans - (40-64세 남성의 토르소 형태 분류에 관한 연구 - 제8차 Size Korea 인체형상으로부터 추출한 측정값을 이용하여 -)

  • Guo Tingyu;Eun Joo Ryu;Hwa Kyung Song
    • Fashion & Textile Research Journal
    • /
    • v.25 no.1
    • /
    • pp.92-103
    • /
    • 2023
  • As the body shape change which occurs after middle age is the main factor affecting the fit of ready-to-wear clothes, this study was designed to classify and analyze the torso shapes of middle-aged men. This study sorted 3D body scans of 200 men aged 40-64 from the 8th Size Korea (2021) database and extracted their 47 measurement values using the Grasshopper algorithm for automatic extraction landmarks and measurements, developed by the previous research (Ryu & Song, 2022). Eight principal components (torso length, shoulder size, overall body size, abdomen prominence, back protrusion, neck inclination, upper body slope, and hip prominence) were identified and four torso shapes were classified. Shape 1 (28.5%) exhibited the shortest torso length, the narrowest shoulders, and the most protruding back. Shape 2 (21.0%) exhibited the skinniest body and the largest backward inclination of the upper body. Hence, the back appeared to be protruding, and the abdomen looked prominent. Shape 3 (25.5%) had the largest overall body size. Thus, the abdomen looked the least protruding, and it exhibited the flattest back. Shape 4 (25.0%) had the longest torso, widest shoulders, straightest neck, and the least protruding hips. This study suggested these three discriminant functions to identify a new person's torso type.

The accurate measurement of center position and orientation of SMD VR by using machine vision (머신비젼을 이용한 SMD VR의 중심위치와 홈방향 정밀계측)

  • Jhang, Kyung-Young;Kim, Byung-Yup;Han, Chang-Su;Park, Jong-Hyun;Gam, Do-Young
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.8
    • /
    • pp.1339-1347
    • /
    • 1997
  • The automation of final inspection and tuning process in the manufacturing of electric products is hot issue now, because it is the only part that has not been wholey automized yet, mainly due to the difficulties to handle so small size of VR which is the final tuning point in the most of electric products. For the automation of this process, at first the accurate measurement of position and orientation of SMD VR on PCB in real time is strongly needed. In this paper, a new image processing algorithm to detect the center position and orientation of target VR by using machine vision is proposed for automatic final tuning of the 8mm camcoder's performance. In the method, the outline feature of object is used actively. The usefulness of the proposed methods were tested by several experiments, and the results showed enough accuracy for both of position and orientation. Additatively, we discussed about the total visual system construction and preprocessing of image.

An Automated Water Nitrate Monitoring System based on Ion-Selective Electrodes

  • Cho, Woo Jae;Kim, Dong-Wook;Jung, Dae Hyun;Cho, Sang Sun;Kim, Hak-Jin
    • Journal of Biosystems Engineering
    • /
    • v.41 no.2
    • /
    • pp.75-84
    • /
    • 2016
  • Purpose: In-situ water quality monitoring based on ion-selective electrodes (ISEs) is a promising technique because ISEs can be used directly in the medium to be tested, have a compact size, and are inexpensive. However, signal drift can be a major concern with on-line management systems because continuous immersion of the ISEs in water causes electrode degradation, affecting the stability, repeatability, and selectivity over time. In this study, a computer-based nitrate monitoring system including automatic electrode rinsing and calibration was developed to measure the nitrate concentration in water samples in real-time. Methods: The capabilities of two different types of poly(vinyl chloride) membrane-based ISEs, an electrode with a liquid filling and a carbon paste-based solid state electrode, were used in the monitoring system and evaluated on their sensitivities, selectivities, and durabilities. A feasibility test for the continuous detection of nitrate ions in water using the developed system was conducted using water samples obtained from various water sources. Results: Both prepared ISEs were capable of detecting low concentrations of nitrate in solution, i.e., 0.7 mg/L $NO_3-N$. Furthermore, the electrodes have the same order of selectivity for nitrate: $NO_3{^-}{\gg}HCO_3{^-}$ > $Cl^-$ > $H_2PO_4{^-}$ > $SO{_4}^{2-}$, and maintain their sensitivity by > 40 mV/decade over a period of 90 days. Conclusions: The use of an automated ISE-based nitrate measurement system that includes automatic electrode rinsing and two-point normalization proved to be feasible in measuring $NO_3-N$ in water samples obtained from different water sources. A one-to-one relationship between the levels of $NO_3-N$ measured with the ISEs and standard analytical instruments was obtained.

Time Pickoff method using an Automatic Gain Control (자동 이득 조절(AGC) 기반의 Time pickoff 회로)

  • Lim, Han-Sang
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.4
    • /
    • pp.80-85
    • /
    • 2011
  • A time-pickoff circuit used for time measurement suffers from a timing error due to the dependence of the generation time of a timing pulse on the size of the input signal, i.e., time walk. In this study, a time-pickoff method, which employs an automatic gain control (AGC) circuit, is proposed for reducing the timing error. The AGC circuit is added to the input of the comparator, and it renders the sizes of input signals of the comparator relatively uniform. The performance of the proposed time-pickoff method is analyzed using the SPICE simulation, and experiments are performed to confirm the analytical results. The measured time walk is reduced to 2.000 ns by 65% for input signals with a dynamic range of 20 dB as compared to a typical leading-edge discriminator.

An automatic rotating annular flume for cohesive sediment erosion experiments: Calibration and preliminary results

  • Steven Figueroa;Minwoo Son
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.319-319
    • /
    • 2023
  • Flows of water in the environment (e.g. in a river or estuary) generally occur in complex conditions. This complexity can hinder a general understanding of flows and their related sedimentary processes, such as erosion and deposition. To gain insight in simplified, controlled conditions, hydraulic flumes are a popular type of laboratory research equipment. Linear flumes use pumps to recirculation water. This isn't appropriate for the investigation of cohesive sediments as pumps can break fragile cohesive sediment flocs. To overcome this limitation, the rotating annular flume (RAF) was developed. While not having pumps, a side-effect is that unwanted secondary circulations can occur. To counteract this, the top and bottom lid rotate in opposite directions. Furthermore, a larger flume is considered better as it has less curvature and secondary circulation. While only a few RAFs exist, they are important for theoretical research which often underlies numerical models. Many of the first-generation of RAFs have come into disrepair. As new measurement techniques and models become available, there is still a need to research cohesive sediment erosion and deposition in facilities such as a RAF. New RAFs also can have the advantage of being automatic instead of manually operated, thus improving data quality. To further advance our understanding of cohesive sediment erosion and deposition processes, a large, automatic RAF (1.72 m radius, 0.495 m channel depth, 0.275 m channel width) has been constructed at the Hydraulic Laboratory at Chungnam National University (CNU), Korea. The RAF has the ability to simulate both unidirectional (river) and bidirectional (tide) flows with supporting instrumentation for measuring turbulence, bed shear stress, suspended sediment concentraiton, floc size, bed level, and bed density. Here we present the current status and future prospect of the CNU RAF. In the future, calibration of the rotation rate with bed shear stress and experiments with unidirectional and bidirectional flow using cohesive kaolinite are expected. Preliminary results indicate that the CNU RAF is a valuable tool for fundamental cohesive sediment transport research.

  • PDF