• Title/Summary/Keyword: automatic program generator

Search Result 36, Processing Time 0.024 seconds

The Definition of Data Structure for Design Knowledge Database and Development of the Interface Program for using Natural Language Processing (설계지식 데이터베이스의 자료구조 규명과 자연어처리를 이용한 인터페이스 프로그램 개발)

  • 이정재;이민호;윤성수
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.43 no.6
    • /
    • pp.187-196
    • /
    • 2001
  • In this study, by using the natural language processing of the field of artificial intelligence, automated index was performed. And then, the Natural Language Processing Interface for knowledge representation(NALPI) has been developed. Furthermore, the DEsign KnOwledge DataBase(DEKODB) has been also developed, which is designed to interlock the knowledge base. The DEKODB processes both the documented design-data, like a concrete standard specification, and the design knowledge from an expert. The DEKODB is also simulates the design space of structures accordance with the production rule, and thus it is determined that DEKODB can be used as a engine to retrieve new knowledge and to implement knowledge base that is necessary to the development of automatic design system. The application field of the system, which has been developed in this study, can be expanded by supplement of the design knowledge at DEKODB and developing dictionaries for foreign languages. Furthermore, the perfect automation at the data accumulation and development of the automatic rule generator should benefit the unified design automation.

  • PDF

Automatic Generation of Code Optimizer for DFA Pattern Matching (DFA 패턴 매칭을 위한 코드 최적화기의 자동적 생성)

  • Yun, Sung-Lim;Oh, Se-Man
    • The KIPS Transactions:PartA
    • /
    • v.14A no.1 s.105
    • /
    • pp.31-38
    • /
    • 2007
  • Code Optimization is converting to a code that is equivalent to given program but more efficient, and this process is processed in Code Optimizer. This paper designed and processed Code Optimizer Generator that automatically generates Code Optimizer. In other words Code Optimizer is automatically generated for DFA Pattern Matching which finds the optimal code for the incoming pattern description. DFA Pattern Matching removes redundancy comparisons that occur when patterns are sought for through normalization process and improves simplification and structure of pattern shapes for low cost. Automatic generation of Code Optimization for DFA Pattern Matching eliminates extra effort to generate Code Optimizer every time the code undergoes various transformations, and enables formalism of Code Optimization. Also, the advantage of making DFA for optimization is that it is faster and saves cost of Code Optimizer Generator.

Development of a Three Dimensional Elastic Plastic Analysis System for the Integrity Evaluation of Nuclear Power Plant Components (원자력발전소 주요기기의 건전성 평가를 위한 3차원 탄소성 해석 시스템의 개발)

  • Huh, Nam-Su;Im, Chang-Ju;Kim, Young-Jin;Pyo, Chang-Ryul;Park, Chi-Yong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.8 s.179
    • /
    • pp.2015-2021
    • /
    • 2000
  • In order to evaluate the integrity of nuclear power plant components, the analysis based on fracture mechanics is crucial. For this purpose, finite element method is popularly used to obtain J-integral. However, it is time consuming to design the finite element model of a cracked structure. Also, the J-integral should be verified by alternative methods since it may differ depending on the calculation method. The objective of this paper is to develop a three-dimensional elastic-plastic J-integral analysis system which is named as EPAS program. The EPAS program consists of an automatic mesh generator for a through-wall crack and a surface crack, a solver based on ABAQUS program, and a J-integral calculation program which provides DI (Domain Integral) and EDI (Equivalent Domain Integral) based J-integral calculation. Using the EPAS program, an optimized finite element model for a cracked structure can be generated and corresponding J-integral can be obtained subsequently.

A study on the Computer-Aided automatic Design of marine water ejector (선박용 수이젝터의 자동설계를 위한 전산프로그램의 개발)

  • 김경근;김용모;김주년;남청도
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.74-84
    • /
    • 1986
  • Ejectors, having no moving, lubricating and leaking parats, are widely used as marine pumps because of its high working confidence. For instance, uses in ships are stripping in crude oil tank, bilge discharge in engine room, ballast water pumping on are carrier, and brine discharge from fresh water generator. And it is also used as cooling water recirculating pump in boiling water type nuclear reactor and deep-well pump. It is not easy to determine the optimal dimension for designing each ejector agreed with its suggested performance condition, because complicated calculations must be repeated to obtain the maximum efficiency affected by flowrate ratio, head ratio, area ratio and so on. Therefore, it is considered that the CAD (Computer-Aided Design) for ejector is a powerful method for design according to the individual design condition. In this paper, a computer program for water ejector design is developed based on the previous paper on theoretical analysis and experimental results for water ejector. And from the theoretical approach, an equation for the working limit and an equation for determing the shape of throat are obtained. The validity of the present computer program is sufficiently confirmed through the comparison of the computed results with the main dimension of the previous manufactured water ejector. This program will be easily developed as the CAD for various kinds of ejectors, including steam ejector.

  • PDF

A Study on the Development of Urine Analysis System using Strip and Evaluation of Experimental Result by means of Fuzzy Inference (스트립을 이용한 요분석시스템의 개발과 퍼지추론에 의한 검사결과 평가에 관한 연구)

  • Jun, K. R.;Lee, S. J.;Choi, B. C.;An, S. H.;Ha, K.;Kim, J. Y.;Kim, J. H.
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.5
    • /
    • pp.477-486
    • /
    • 1998
  • In this paper, we implemented the urine analysis system capable of measuring a qualitative and semi-quantitative and assay using strip. The analysis algorithm of urine analysis was adopted a fuzzy logic-based classifiers that was robust to external error factors such as temperature and electric power noises. The spectroscopic properties of 9 pads In a strip were studied to developing the urine analysis system was designed for robustnesss and stability. The urine analysis system was consisted of hardware and software. The hardware of the urine analysis system was based on one-chip microprocessor, and Its peripherals which composed of optic modulo, tray control, preamplifier, communication with PC, thermal printer and operating status indicator. The software of the urine analysis system was composed of system program and classification program. The system program did duty fort system control, data acquisition and data analysis. The classification program was composed of fuzzy inference engine and membership function generator. The membership function generator made triangular membership functions by statical method for quality control. Resulted data was transferred through serial cable to PC. The transferred data was arranged and saved be data acquisition program coded by C+ + language. The precision of urine analysis system and the stability of fuzzy classifier were evaluated by testing the standard urine samples. Experimental results showed a good stability states and a exact classification.

  • PDF

Clinical Evaluation for System Performance of Image Intensifiers (상강화기의 임상평가)

  • Kim, Chang-Seon;Charles R. Wilson
    • Progress in Medical Physics
    • /
    • v.9 no.3
    • /
    • pp.143-154
    • /
    • 1998
  • The image intensifier is the key component which determines the imaging characteristics in a fluoroscopic imaging system. A system performance program for clinical evaluation of two image intensifiers, that is simple, non-invasive and time effective, was described. Tests were grouped into three headings: x-ray generator, image quality, and collimation. For the x-ray generator, the kVp accuracy and the automatic exposure control operation were compared. Low- and high-contrast resolution measurements, and mesh pattern study belong to the image quality tests and those tests were performed for the video monitor and photospot images. For the collimation, usable field diameter and image distortion of image intensifiers were measured and quantified. The procedures and the results are hoped to be used for the clinical evaluation of system performance and/or acceptance tests for image intensifiers.

  • PDF

Performance analysis of the B-NT system using simulstor (시뮬레이터를 이용한 B-NT 시스템 성능분석)

  • 이규호;기장근;노승환;최진규;김재근
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.23 no.6
    • /
    • pp.1503-1513
    • /
    • 1998
  • This paper is related to a performance analysis of B-NT system, which is essential compositional equipment of B-ISDN access network. A simulator enabling performance analysis according to the change of network configuration topology and the change of user traffic is developed in this study. The developed B-NT, system simulator consists of graphic user interface module, simulation program automatic generator module, and B-NT system model library module. As examples of the results of performance analysis using the simulator, end-to-end user cell transmission delay time, queueing delay time in each system, and cell loss rate in the head node switch are presented. The simulator developed in this paper can be utilized in determining the network topology of B-NT system.

  • PDF

A Development of a Software Tool for Automatic SCF Design (SC 필터의 자동 설계를 위한 프로그램의 개발)

  • Lee, Sang-Won;Kim, Yong-Seop;Kim, Seong-Won;Kang, Wook;Kim, Soo-Won;Kim, Duck-Jin
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.27 no.4
    • /
    • pp.620-627
    • /
    • 1990
  • A software tool implementing cascaded SCF (Switched Capacitor Filter) is developed. A comprehensive procedure is described for the design of cascaded SCF, and some design considerations are discussed. In program several user-selectable filter approximation techniques, and two optimising methods which reduce the total capacitance are included. Analysis of the partial positive feedback and the effect of clock frequency to total capacitance are presented in detail. Two pratical examples are given to prove its validity in reducing the total capacitance. Developed tool can be used for general SCF generator.

  • PDF

Computer aided reinforcement design of RC structures

  • An, Xuehui;Maekawa, Koichi
    • Computers and Concrete
    • /
    • v.1 no.1
    • /
    • pp.15-30
    • /
    • 2004
  • In this study, a design process for reinforced concrete structures using the nonlinear FEM analysis is developed. Instead of using the nonlinear analysis to evaluate the required performance after design process, the nonlinear analysis is applied before designing the reinforcement arrangement inside the RC structures. An automatic reinforcement generator for computer aided reinforcement agreement is developed for this purpose. Based on a nonlinear FEM program for analyzing the reinforced concrete structure, a smart fictitious material model of steel, is proposed which can self-adjust the reinforcement to the required amount at the cracking location according to the load increment. Using this tool, the reinforcement ratio required at design load level can be decided automatically. In this paper, an example of RC beam with opening is used to verify the proposed process. Finally, a trial design process for a real size underground RC LNG tank is introduced.

Improved X-ray Center Beam Alignment Evaluation Method (개선된 X선 중심선속정렬평가 측정법)

  • Choi, Seokyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.6
    • /
    • pp.827-832
    • /
    • 2020
  • X-ray equipment, which is frequently used in radiology and treatment, is the most common and most used equipment in clinical practice. Equipment must provide accurate information to patients through continuous quality control. In case of manual quality control measurement, reproducibility may be poor and there may be a problem with reliability of evaluation results. In this study, an automated program was developed and attempted to measure how much the central ray between the focus of the X-ray tube and the variable aperture of the diagnostic X-ray generator used in clinical practice coincides. As a result of the experiment, it succeeded in calculating the coordinates of the two center points, and the distance between the two points was calculated in pixels and applied to the judgment and the automatic judgment value for whether the center line coincidence is within the normal angle or the abnormal angle is presented. The results of this study are considered to be very helpful in the quality control of the X-ray apparatus.