• 제목/요약/키워드: automatic measurement system

검색결과 611건 처리시간 0.023초

과일의 진동특성을 이용한 주파수 영역에서의 경도측정 (Development of Automatic Firmness Measurement System for Major Fruits using Vibration Characteristics)

  • 전종서;김중규
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 하계종합학술대회 논문집(4)
    • /
    • pp.253-256
    • /
    • 2001
  • Characteristics of fruit vibrations are related to the material properties of the fruit. A new method for spectral analysis is developed and used for the non-destructive estimation of fruit firmness. The resonant frequency of the fruit is related to its firmness. However, the determination of the resonant frequency is not easy So the smoothing method is applied to the frequency spectra to obtain a robust estimate for the resonant frequency.

  • PDF

수박 밀도 자동 계측시스템 개발 (Development of Automatic Measurement System for Density of Watermelons)

  • 최규홍;이강진;손재룡;김기영;최동수
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 2003년도 하계 학술대회 논문집
    • /
    • pp.317-326
    • /
    • 2003
  • 원예산물은 출하과정에서 외관과 내부품질에 따라 분류되고, 그 결과에 따라 상품성과 가격이 결정된다. 수박의 경우에도 품질이나 가격은 크기, 무게, 외피모양, 타격할 때 나는 반사음, 촉감 등에 따라 결정되는데, 주로 경매사 또는 감별사의 경험이나 표본검사에 의존하고 있다. 최근 과실류에 비해 크고 껍질이 두꺼운 수박, 메론 등의 내부품질을 비파괴ㆍ실시간으로 판정하기 위한 연구가 국내외에서 활발히 수행중이다. 특히 X-선, 음파, 근적외선 등을 이용하여 숙도, 공동, 당도, 밀도 등을 신속히 검출하기 위한 연구가 대부분을 차지하고 있다. (중략)

  • PDF

The Application of Fuzzy Set Theory into Precise Adjustment System

  • Ishimaru, Ichirou
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 1993년도 Fifth International Fuzzy Systems Association World Congress 93
    • /
    • pp.1155-1158
    • /
    • 1993
  • Proficiency in creating a knowledge base is required for high accuracy fuzzy control. To overcome this a fuzzy inference method is proposed that take these membership functions from the probability densities showing the distribution of the mesurement values. And a method using a rough fuzzy knowledge base automatically created from the basic measurement data and tuned using the gradient method is proposed. In actual tests, these were applied to automatic high accuracy adjustment devices for magnetic head and for high frequency circuits with good results.

  • PDF

이동평균 영상처리기법을 이용한 금속판재 표면품질 정밀 측정시스템 연구 (A Study on Precision Measurement System for Metal Plate Surface Quality Using Moving Average Image Processing Techniques)

  • 김태수;전중창
    • 한국산업정보학회논문지
    • /
    • 제17권2호
    • /
    • pp.73-80
    • /
    • 2012
  • 산업자동화를 위한 영상처리기술을 활용하여 금속 표면 검사 공정의 육안 검사를 대체하기 위한 장치개발이 요구된다. 본 논문에서는 압연 공정의 금속 판재 표면의 결함을 탐지하기 위하여 이동평균 영상처리기법을 적용한 정밀측정시스템을 제안하였다. 금속 판재의 압연 처리 과정에서 발생하는 표면 패턴이 결함으로 판정될 수 있다. 이러한 경우에 대하여 제안한 시스템을 적용하여 금속 판재 표면의 실제 결함의 수를 측정할 수 있었고 FFT방법에 의한 측정치에 비하여 양호한 결과를 얻었다.

System Strategies for Time-Domain Emission Measurements above 1 GHz

  • Hoffmann, Christian;Slim, Hassan Hani;Russer, Peter
    • Journal of electromagnetic engineering and science
    • /
    • 제11권4호
    • /
    • pp.304-310
    • /
    • 2011
  • The application of time-domain methods in emission measurement instruments allows for a reduction in scan time by several orders of magnitude and for new evaluation methods to be realized such as the real-time spectrogram to characterize transient emissions. In this paper two novel systems for time-domain EMI measurements above 1 GHz are presented. The first system combines ultra-fast analog-to-digital-conversion and real-time digital signal processing on a field-programmable-gate-array (FPGA) with ultra-broadband multi-stage down-conversion to enable measurements in the range from 10 Hz to 26 GHz with high sensitivity and full-compliance with the requirements of CISPR 16-1-1. The required IF bandwidths were added to allow for measurements according to MIL-461F and DO-160F. The second system realizes a system of time-interleaved analog-to-digital converters (ADCs) and has an upper bandwidth limit of 4 GHz. With the implementation of an automatic mismatch calibration, the system fulfills CISPR 16-1-1 dynamic range requirements. Measurements of the radiated emissions of electronic consumer devices and household appliances like the non-stationary emissions of a microwave oven are presented. A measurement of a personal computer's conducted emissions on a power supply line according to DO-160F is given.

Advancing behavioral understanding and damage evaluation of concrete members using high-resolution digital image correlation data

  • Sokoli, Drit;Shekarchi, William;Buenrostro, Eliud;Ghannoum, Wassim M.
    • Earthquakes and Structures
    • /
    • 제7권5호
    • /
    • pp.609-626
    • /
    • 2014
  • The capabilities of a high-resolution Digital Image Correlation (DIC) system are presented within the context of deformation measurements of full-scale concrete columns tested under reversed cyclic loading. The system was developed to have very high-resolution such that material strains on the order of the cracking stain of concrete could be measured on the surface of full-scale structural members. The high-resolution DIC system allows the measurement of a wide range of deformations and strains that could only be inferred or assumed previously. The DIC system is able to resolve the full profiles of member curvatures, rotations, plasticity spread, shear deformations, and bar-slip induced rotations. The system allows for automatic and objective measurement of crack widths and other damage indices that are indicative of cumulated damage and required repair time and cost. DIC damage measures contrast prevailing proxy damage indices based on member force-deformation data and subjective damage measures obtained using visual inspection. Data derived from high-resolution DIC systems is shown to be of great use in advancing the state of behavioral knowledge, calibrating behavioral and analytical models, and improving simulation accuracy.

시계열 데이터의 확률분석을 통한 SOC 구조물 자동화계측 분석기법 개선 (Improvement of SOC Structure Automated Measurement Analysis Method through Probability Analysis of Time-History Data)

  • 최정열;안대희;한재민;정지승;김정호;주봉철
    • 문화기술의 융합
    • /
    • 제9권1호
    • /
    • pp.679-684
    • /
    • 2023
  • 현재 우리나라는 도심지 과밀도로 구조물과 인접하여 대규모, 대심도 굴착시공이 이루어지고 있다. 도심지에서의 인접굴착공사는 흙막이 구조물 및 지하구조물의 안전성 확보가 매우 중요하다. 이에 자동화계측 시스템을 도입하여 시설물에 대한 안전성을 관리하고 있다. 그러나 자동화계측 시스템 결과의 활용도는 매우 낮은 실정이다. 종래 평가기법은 측정된 데이터의 최댓값에만 의존하여, 이상 거동을 과대 평가할 수 있는 기법이다. 본 연구에서는 자동화계측 결과에 대한 분석기법을 개선하고자 한다. 시설물의 이상거동을 파악하기 위해 자동화계측 데이터 시계열 분석기법을 제시하였다. 또한 방대한 양의 데이터를 확률통계 분석기법을 적용하여 신뢰성 높은 결과를 도출하였다. 따라서 본 연구에서는 시설물의 방대한 양의 데이터를 처리할 수 있는 분석기법 및 평가기법을 개선하였다.

계란(鷄卵) 자동(自動) 선별기(選別機)의 난중측정(卵重測定) 정밀도(精密度) 향상(向上)에 관(關)한 기초연구(基礎硏究) (Study on precision improvement in weight measurement of an egg for the automatic egg sorting system)

  • 김기대;복진삼
    • 농업과학연구
    • /
    • 제27권1호
    • /
    • pp.48-53
    • /
    • 2000
  • 1. 난중(卵重) 및 진동량 계측 시스템은 로드셀 1개를 이용한 기존의 방법을 로드셀 배치 I, 계란의 이송방향과 평행하게 같은 방향으로 부착한 방법을 로드셀 배치 II 로 하였고 로드셀 2개를 이용하여 서로 마주보도록 부착한 방법을 로드셀 배치 III, 2 개의 로드셀이 계란의 이송방향과 평행하게 같은 방향으로 부착한 방법을 로드셀 배치 IV로 구성하여 난중(卵重) 및 진동량을 측정, 분석 하였다. 2. 4가지의 로드셀 배치에 따른 난중(卵重)측정결과 로드셀 배치 I, 로드셀 배치 II, 로드셀 배치 III, 로드셀 배치 IV에 의한 난중(卵重)평균 오차가 각각 1.2128g, 0.5953g, 0.7786g, 0.2793g으로 로드셀 2개를 계란 이송방향과 평행하게 부착한 방법이 난중(卵重) 평균 오차가 가장 낮게 나와 정밀도가 매우 높음을 알 수 있었다. 3 계란 자동 선별기를 이용하여 대란 등급의 계란 선별시 X, Y, Z축 방향에서 평균 진동량이 각각 $5.1937{\times}10^{-3}G$, $9.3604{\times}10^{-3}G$, $16.8657{\times}10^{-3}G$로서 Z축방향의 진동값이 X, Y방향보다 상대적으로 크다는 것을 알 수 있었다.

  • PDF

자동배수형 무게식 강수량계 개발 및 강우량 측정 성능검사 (Development of Auto-Empting Type Weighing Precipitation Gauge and Performance Test on Rainfall Measurement)

  • 김상조;손탑
    • 대기
    • /
    • 제22권2호
    • /
    • pp.279-285
    • /
    • 2012
  • The weighing precipitation gauge with auto-empting capability was developed in the R&D project organized by the Research Agency for Climate Science (RACS) and supported by the Korea Meteorological Administration (KMA). This project was initiated in line with the KMA's plan executed since 2010 to introduce the weighing precipitation gauges partly into of their Automatic Weather Station (AWS) network in order to upgrade the quality of precipitation data. The innovative feature of this research is that the auto-empting in weighing precipitation gauge is realized by abrupt rotation of receiving container. The prototype was tested in compliance with the relevant standards of KMA. The results of performance test on rainfall measurement in laboratory verified that the accuracies for 20 mm and 100 mm reference rainfall amount were 0.1 mm and 0.4 mm, respectively in both conditions of auto-empting and no-empting. During the rotation of container for auto-empting, the data was extrapolated smoothly by applying the same precipitation intensity of the previous 10 sec. Consequently, it was found that the auto-empting precipitation gauge developed in this research is quite enough to be used for the operational purpose of accurate measurement with 0.1 mm resolution, regardless of the precipitation intensity.