Implementation of ATE to Maintain Pre-Amplifier of Thermal Imaging System (열상장비 전단증폭부 정비용 ATE의 구현)

  • Park, Jai-Hyo;Kim, Han-Kyung
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.49 no.1
    • /
    • pp.80-87
    • /
    • 2012
  • We have developed the ATE(Automatic Test Equipment) system for the performance test of pre-amplifier of thermal imaging devices. The device regenerates the electronic signals of photon detection module which is normally in weak energy, for the image signals processing. Previous ATE system was primarily and actively developed in the field of semiconductor devices quality parts inspection. Recently, it has been studied in the field of performance testing of equipment. In the field of thermal performance test equipment, however, it lacks the study of ATE compared to other areas, which causes the maintenance related to the core of military thermal imaging system maintenance to be limited. In this paper, a new study of ATE in the field of thermal imaging system is done. It is designed to be used universally for the ATE system with different types of circuit card of thermal imaging system by adopting matrix relays. Using the developed ATE measuring the pre-amplifier amplitude, an average amplified amplitude of 2.71Vpp was measured which confirms that it is within the range of theoretical analysis and also verifies the good performance of the developed ATE.

The Hydraulic System Modeling and Analysis of the Clutch Direct Control of an Automatic Transmission for a Forklift Truck (지게차 자동변속기의 클러치 직접 제어 유압 시스템 모델링 및 해석)

  • Oh, Joo-Young;Lee, Guen-Ho;Song, Chang-Sub
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.1
    • /
    • pp.112-119
    • /
    • 2009
  • An automatic transmission of construction equipment is controlled by hydraulic and electronic system for doing in various functions like as shifting and operation. The shifting is operated by the engaged and disengaged clutch motion from hydraulic power. On the shifting process, suitable pressure control to the clutch is required for smooth shifting. Hydraulic control system in the automatic transmission is divided by the pilot control type and the direct control type greatly. The direct control type has an advantage than the pilot control type. Because the structure is simple, the design and the manufacture are having less troubles and the system can be maximized precision pressure control. However, the excellent performance proportional control valve should be used to achieve proper control-ability. In this study, the dynamic analysis model composing the automatic transmission and hydraulic system for forklift truck is presented to simulate the characteristics of hydraulic system about the direct control type. That model is verified the validity compared the results of the testing examination. Parameters of input signal are analyzed to reduce the output torque according to input control signal is affected in shifting characteristic.

Development of an USN Based Integrated Open Server System for Disaster Prevention Management (USN 기반 개방형 방재관리 통합시스템 개발)

  • Lee, Jeong-Kyoon;Lee, Ki-Young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.10a
    • /
    • pp.929-932
    • /
    • 2007
  • The integrated prevention of disaster management system is collected prevention of disaster data from prevention of disaster relation other systems and smart sensor in USN. This system manages fire fighting facility effectively. The relation equipment which is used in existing and network using "Open Protocols" about under using the support system which is integrated effectively as the destroyer. It connects CCTV, the sensitivity environmental sensor, automatic fire detection equipment and security equipment and air flow equipment system using Internet. The System Server was collected monitoring data at the each equipment and processing by operational scenario. It will verified the effectiveness of operational scenario and integrated prevention of disaster management system

  • PDF

SCADA System for Semiconductor Equipment Condition Monitoring (반도체 장비상태 모니터링을 위한 SCADA 시스템 구현)

  • Lee, Youn Ji;Yun, Hak Jae;Park, Hyoeun;Hong, Sang Jeen
    • Journal of the Semiconductor & Display Technology
    • /
    • v.18 no.4
    • /
    • pp.92-95
    • /
    • 2019
  • Automation control and the data for control of industrial equipment for the diagnosis and prediction is a key to success in the 4th industrial revolution. It increases process efficiency and productivity through data collection, realtime monitoring, and the data analysis. However, university and research environment are still suffering from logging the data in manual way, and we occasionally loss the equipment data logging due to the lack of automatic data logging system. State variable presents the current condition of the equipment operation which is closely related to process result, and it is valuable to monitor and analyze the data for the equipment health monitoring. In this paper, we demonstrate the collection of equipment state variable data via programmable logic controller (PLC) and the visualization of the collected data over the Web access supervisory control and data acquisition (SCADA). Test vehicle for the implementation of the suggested SCADA system is a relay switched physical vapor deposition system in the university environment.

The AQR Control in the SCADA System of Manless Power Plant (무인발전소 SCADA SYSTEM 에서의 AQR 제어 운영)

  • Ok, Yeon-Ho;Lee, Eun-Woong;Byun, Ill-Hwan;Kim, Ki-Won;O, Seok-Yeong;Choi, Hyeong-Cheol;Lee, Nam-Hyung
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.58_59
    • /
    • 2009
  • Generator excitation system, supplying the voltage to power system, is controlled by various manners as aspects of power system. Previously excitation systems mainly used AVR(Automatic Voltage Regulator) and FCR(Field Current Regulator) to control voltage, but nowadays the excitation systems have the tendency to adopt AQR(Automatic Reactive power Regulator) and APFR(Automatic Power Factor Regulator) to do it so as to get into step with diverse requirements of power system and high digital technology. This paper presents which operation methods is effective for the equipment, according to increase the unmanned power station thanks to automation technic.

  • PDF

The study on the development of intelligent optical communication system to monitor flood and water pollution (홍수 및 수질 오염 감시용 지능형 고속 광 통신 시스템 개발에 관한 연구)

  • Lee, Jin-Young
    • Journal of Digital Convergence
    • /
    • v.10 no.11
    • /
    • pp.351-358
    • /
    • 2012
  • This study is aimed at suggesting optical communication equipment that can deliver high quality video information in high speed, to efficiently handle the flood and water pollution in the river basin. This system is cheaper than existing equipment, and can monitor optical Internet as well as the condition of equipment. Generally, the communication equipment to prevent flood is installed in an unmanned control box and operated by the flood control office situated at the fiver mouth in a long distance section. Therefore, it is hard to promptly cope with communication interruptions, which occur by the cutting or aging of the optical cable. Under the circumstances, this study suggested an efficient system that can deliver high quality video information in high speed (Optical Transmission Convert System) by using optical fiber. The system also solves problems by making use of automatic protection switching (APS) when an accident happens. Its real-time monitoring function gives notice of the problem-occurring points. The system is expected to be widely used in various areas such as intelligent traffic systems.

A study on maintenance equipments automatic state and implication for Metro EMU (도시철도 전동차량 유지보수 설비 자동화 실태와 시사점에 관한 연구)

  • Lee, Duk-Gyu;Lee, Hi-Sung
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.561-566
    • /
    • 2008
  • The EMU of maintenance technique or system is changing on a large scale. To subway operation beginning the breakdown was born and every that time after the fact repaired. But, recently before the breakdown of the subway occurs, repairs in advance with the preventive maintenance concept which was exchanged. However, the preventive maintenance is to readjust, cleaning, tighten and the oil the repetition by the worker simple experience. This study on introduces the EMU of maintenance method which applies a automatic inspection equipment from the study contributing which develops the preventive maintenance system.

  • PDF

Automatic Distribution System using a Micro Controller Unit (MCU를 이용한 자동 분류 시스템)

  • Kim, Tae-Hyoung;Lee, Chan-Jae;Kwon, Jae-Hyoung;Kim, Young-Seong;Kim, Yik-Hyoun;Tak, Bo-Mi;Soh, Dea-Wha
    • Journal of the Speleological Society of Korea
    • /
    • no.81
    • /
    • pp.35-41
    • /
    • 2007
  • According as the industry develops recently, the import and export freight amount is increasing sharply, but physical distribution processing equipment ability had achieved conveyance, surge and setup of physical distribution by human's labor ability. But, inefficiency is indicated in operation of product line and warehouse or physical distribution storage equipment because is ceilinged the processing physical distribution amount and the efficiency in physical distribution processing by these labor ability.

A Study on Automatic Test Equipment Validation in the Realm of Defense (국방 분야 자동화시험장비 유효성 확인 방안에 관한 연구)

  • Pak, Se-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.9
    • /
    • pp.144-150
    • /
    • 2020
  • This study examined the current status of ATE in the development stage of the domestic guided weapons field, including the re-establishment of automatic test equipment (ATE), and attempted to develop methods to verify the validity of ATE in the defense sector. This study includes methods for confirming the repeatability and reproducibility of newly manufactured or replaced ATE. An error injection test is required for validation in the development phase. And pre-inspection steps are required for validation. When developing ATE, the use of an international standard testing script language ensures efficient validation and SW reliability. This ensures interoperability between the main and test equipment, and the tester can secure a test system platform that supports standardized testing methods, which is considered to be effective in validating specific ATE for each weapon system.

Development of Integrated Test Equipment for Airborne SAR System and Control Unit (항공탑재 SAR 시스템 및 통제장치 시험을 위한 통합시험장비 개발)

  • Lee, Hyon-Ik;Hwang, Tae-Jin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.9
    • /
    • pp.747-754
    • /
    • 2013
  • This paper describes SCTE(System and Control unit Test Equipment) as an integrated test equipment for airborne SAR system and control unit. SCTE enhances reusability of test equipment by modular design for required functions and strengthens automatic testing and test convenience by providing functions such as script-based testing function and report generation function. Also, it includes a navigation data simulator which can simulate various flight conditions. In this paper, we details SCTE requirements, H/W and S/W design, implementation, and test results with control unit and SAR system.