• Title/Summary/Keyword: automatic equipment system

Search Result 534, Processing Time 0.027 seconds

Study for Developing Core Solution of CBTC localization (국산화를 위한 CBTC 핵심장치개발 연구)

  • Kim, Yun-Bae;Yoon, Ho-Sok
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.1106-1112
    • /
    • 2008
  • Recently many new subway lines and light rail lines are demanded to build as CBTC system for advanced transportation needs. Already several lines are being installed and some other are planned this days. In early 2008, the first korean CBTC project, Bundang Line Intelligent Train Control System was finished successfully then it showed that many advantage of its functionalities to demonstrate. Nowaday, the technology of CBTC in Korea is not standing alone by itself yet, even though a lot of localization was done last decade include ATS (Automatic Train Supervision) and Radio Communication and manufactures and installations, because the core equipment of CBTC is rely on oversea technologies of major railway signal companies. KRRI has been preparing to develop the core equipment of CBTC (wayside ATP and onboard ATO/ATP) with other 14 local railway signal companies. Now they have consisted two consortiums to develop the core equipment by themselves. In this paper, I will mention about how we should focus on the output for viewpoint of interpretabilities between the two groups and review the case study of front developers efforts considering to standardizations we should be following.

  • PDF

A Study on the Reliability Management of Onboard Signaling Equipment for the Korean Tilting Train (한국형 틸팅열차 차상신호장치 신뢰성관리에 대한 연구)

  • Shin, Duck-O;Baek, Jong-Hyun;Lee, Knag-Me;Kim, Yong-Kyu
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.6
    • /
    • pp.852-858
    • /
    • 2009
  • This paper is a study on the reliability management of onboard signaling equipment for the Koran Tilting Train (TTX) to run the existing railway to express railway. For safe running of tilting train which operates at Automatic Train Protection (ATP) and Automatic Train Stop (ATS), a reliability management plan for TTX onboard is proposed for preventing train safety from driver oversight and malfunction by establishing braking curves based on movement authority and speed limit, according to preceding train location and rail conditions. Also, reliability of TTX onboard equipment on the basis of proposed plan was estimated, and actual case studies based on the international requirements IEC 62278 (EN 50126) were provided to verify its reliability.

A study on practical use of remote automatic fire extinguishing equipment through test bed in road tunnel (도로터널용 원격 자동소화 설비의 test bed 적용을 통한 실용화 방안 연구)

  • Park, Sang-Heon;An, Sung-Joo;Kim, Jae-Hoon;Kim, Kyung-soo;Yun, Jun-Su;Yoo, Yong-Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.6
    • /
    • pp.837-847
    • /
    • 2019
  • Korea's long underground roads are being promoted around the metropolitan city center to realize advanced transportation networks. Many disaster prevention facilities are applied to secure fire safety of the closed and long-distance underground roads. As the facility response and fire suppression subjects are unclear, additional human and material damages from fire spread are inevitable. Therefore, in this study, we developed a remote automatic fire extinguishing system that uses the fire extinguishing water inside the fire hydrant to monitor the CCTV in the management room and sprays it directly to the fire site through automatic control. The design application method was studied through the performance improvement that can be put into practical use.

Reliability Analysis of Slab Transfer Equipment in Hot Rolling Furnace (열간압연 가열로 슬라브 이송장치 신뢰도 해석)

  • Bae, Young-Hwan
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.1 s.73
    • /
    • pp.6-14
    • /
    • 2006
  • The development of automatic production systems have required intelligent diagnostic and monitoring functions to overcome system failure and reduce production loss by the failure. In order to perform accurate operations of the intelligent system, implication about total system failure and fault analysis due to each mechanical component failures are required. Also solutions for repair and maintenance can be suggested from these analysis results. As an essential component of a mechanical system, a bearing system is investigated to define the failure behavior. The bearing failure is caused by lubricant system failure, metallurgical deficiency, mechanical condition(vibration, overloading, misalignment) and environmental effects. This study described slab transfer equipment fault train due to stress variation and metallurgical deficiency from lubricant failure by using FTA.

Development of Automatic Measurement and Inspection System for ALC Block Using Camera (카메라를 이용한 ALC 블록의 치수계측 및 불량검사 자동화 시스템 개발)

  • 허경무;김성훈
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.6
    • /
    • pp.448-455
    • /
    • 2003
  • A system design technique of automatic thickness measurement and defect inspection system, which measures the thickness of the ALC(Autoclaved Lightweight Concrete) block and inspects the defect on a realtime basis is proposed. The image processing system was established with a CCD camera, an image grabber, and a personal computer without using assembled measurement equipment. The image obtained by this system was analyzed by a devised algorithm, specially designed for the enhanced measurement accuracy. For the realization of the proposed algorithm, the preprocessing method that can be applied to overcome uneven lighting environment, an enhanced edge decision method using 8 edge-pairs with irregular and rough surface, the unit length decision method in uneven condition with rocking objects, and the curvature calibration method of camera using a constructed grid are developed. The experimental results, show that the required measurement accuracy specification is sufficiently satisfied using our proposed method.

Development of Automatic Digital/Analog Lighting Control System using ATMega 128 (ATMega128을 이용한 디지털/아날로그 자동조명제어장치의 개발)

  • Kim, Dong-Wan;Park, Sung-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.55 no.4
    • /
    • pp.161-166
    • /
    • 2006
  • In this paper, an automatic lighting control system is developed using microprocessor. The developed system consists of a digital lighting control unit, an analog lighting control unit, and a lighting control simulator. In the developed system, ATMega128 is used as the main controller. The developed digital lighting control unit consists of eight modules and the developed analog lighting control unit consists of six modules respectively. Additional, the developed simulator consists of a digital and an analog lighting control simulation using graphic user interface. And so this developed system can be applied to the controller design of the interior and exterior lighting equipment.

Experimental Study on the Indoor Thermal Characteristics for Floor Radiant Heating System (바닥복사 난방시스템의 실내 열환경 특성에 대한 실험적 연구)

  • Song, Jae-Yeob;Ahn, Byung-Cheon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.17 no.3
    • /
    • pp.1-12
    • /
    • 2021
  • In this study, the effects of various operational conditions for floor radiant heating system were researched by experiments. Hot water supply set temperature, indoor air set temperature and supply water flowrate were considered as operational conditions. The control method for this system is On-Off control of automatic thermostatic valve. The purpose of this study is to evaluate indoor thermal control characteristics and energy performance, respectively. As a result, if lower supply water temperature is applied, the supply and return temperature difference is reduced and energy consumption of heat supply is also reduced.

The Construction of the Fishing-vessel Monitoring System and the Protocol Analysis for the Calling of Location Requirement Using VHF-DSC (VHF-DSC 위치요청 프로토콜 분석과 어선관제시스템 구축)

  • Kim, Jeong-nyun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.10a
    • /
    • pp.929-932
    • /
    • 2013
  • In preperation for the compulsory installation of VHF(Very High Frequency) wireless equipment and fishing vessel automatic identification system according to the revision of "The Ships Safety Act" and "Fishing Vessel act", Fishery Information & Communication Department of National Federation of Fisheries Cooperatives is building VHF communication network and automatic identification system for fishing vessel monitoring. This study suggests the protocol analysis for the calling of location requirement using DSC(Digital Selective Calling) function and show best way for fishing vessel automatic identification system. Also, it suggest way to realize fishing vessel monitoring system.

  • PDF

The Construction of the Vessel Monitoring System and the Protocol Analysis for the Calling of Location Requirement Using VHF-DSC (VHF-DSC 위치요청 프로토콜 분석과 선박관제시스템 구축)

  • Kim, Jeong-Nyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.12
    • /
    • pp.2800-2805
    • /
    • 2013
  • In preperation for the compulsory installation of VHF(Very High Frequency) wireless equipment and fishing vessel automatic identification system according to the revision of "The Ships Safety Act" and "Fishing Vessel act", Fishery Information & Communication Department of National Federation of Fisheries Cooperatives is building VHF communication network and automatic identification system for fishing vessel monitoring. This study suggests the protocol analysis for the calling of location requirement using DSC(Digital Selective Calling) function and show best way for fishing vessel automatic identification system. Also, it suggest way to realize fishing vessel monitoring system.

The Application of New Calibrator[I-125]Set for Equipment Quality Management (장비정도관리에 Calibrator[I-125] Set 적용)

  • Kim, Ji-Na;An, Jae-seok;Won, Woo-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.108-111
    • /
    • 2015
  • Purpose Lately, in accordance with the increasing interest about Healthcare accreditation program and International laboratory accreditation scheme, requirements about the instrument quality management are gradually taking shape. In nuclear medicine In vitro laboratory, the most typical instruments are multi detector gamma counter and automatic dispensing system. Each laboratory continue with the quality control adequate for circumstances. The purpose of this study is to application and establish the new Calibrator[I-125]Set which is efficient at standardization of equipment quality management. Materials and Methods Deviation between detectors were measured with 12 solid samples of the Calibrator[I-125]Set. their activities differ from each other by less than 1%. Multi detector gamma counters are GAMMA-10;Shinjin medics. Inc, Goyansi, Korea(Gamma counter A), SR300;Stratec biomedical systems AG, Gewerbestr, Germany(Gamma counter B) and COBRA II; Packard Instrument Co. Inc, Meriden, USA(Gamma counter C). Evaluation of two automatic dispensing system used A, B liquid tracer of the Calibrator[I-125]Set. After dispensing and counting, calculated using the ratio of the measured value and proposed value. We used solution A for 20, 25ul and solution B for 50, 100ul. Method of data analysis and reference range was provided by kit documentation. Furthermore, we could calculate our counter efficiency indirectly. Results The CV(%) of measured values by Gamma counter A, B, C are 0.34, 0.70, 1.30. Calculated value are 1.05314, 2.10419, 4.08485. Provided reference range is less than 3. A dispensing system's calculated values are 0.986, 0.989, 1.023, 1.017 and B are 0.874, 0.725, 1.021, 0.904. Provided reference range is from 0.95 to 1.05. Also, counter's efficiency are 74.18, 72.79, 74.32% at counter A, B, C and efficiency of the one detector counter is 79.26%. Conclusion If using this Calibrator[I-125]Set after verifying whether quality assurance, is applicable to equipment quality management on behalf of the role of gold standard.

  • PDF