• Title/Summary/Keyword: auditory stimulation

Search Result 142, Processing Time 0.026 seconds

Comparison and Analysis of Response of Premature Infants to Auditory Stimulus (일변량 분산 분석과 이변량 시계열 분석을 이용한 미숙아의 목소리 자극에 대한 심박동수와 호흡수 반응의 비교)

  • Lee, Hye-Jung
    • Child Health Nursing Research
    • /
    • v.15 no.3
    • /
    • pp.261-270
    • /
    • 2009
  • Purpose: The purpose of this study was to compare the result of one-way ANOVA with that of cross-correlation time series analysis in order to evaluate physiologic responses of premature infants to human voices. Methods: Four premature infants born prior to 32 weeks gestational age were included in the study. The Gould 4000TA Recording System recorded the preterm infant's heart and respiratory rate while they were listening to a pre-recorded voice recording. Each infant listened to both male and female voices (1 min each) at each testing session. Results: The results of both one-wayANOVA and cross-correlation time series analysis using heart and respiratory rate data were not consistent in some of premature infants. A cross-correlation time series analysis revealed that the responses of premature infant to vocal stimulation occurred at a varying number of seconds after the stimulus was presented and lasted for over 20-30 sec. Conclusion: The results indicate that a time series analysis can provide more detailed information on the rapidly changing physiologic status of premature infant to the auditory stimulus. In addition, the results provide an insight into an auditory responsitivity of premature infants to a naturally occurring sound, the human voice, in the neonatal intensive care unit.

  • PDF

A Study of the influence of stimulus on newborn infant생s response -Specifically in heart rate change- (감각적 자극에 따른 신생아 반응에 관한 연구 -심박동수를 중심으로-)

  • 이자형;하영수
    • Journal of Korean Academy of Nursing
    • /
    • v.13 no.3
    • /
    • pp.119-126
    • /
    • 1983
  • Early extra-uterine development of the newborn infant has the potential for clarifying important questions of nature and care taking environment. In this study, tactile and auditory stimulation is used on .a group of infants to determine the effects of their response. Infants were tested by EKG at 24∼48 hrs after birth ana all they are free from complication. Stimuli presented were-touch and sound (40dB, 70dB and 40∼70dB). The result of the study were as follows: 1) The heart rate was seen to depend on their sleep-wake state. (light sleep ; 125/min, eyes: open & motor activity increase ; 151/min crying ; 185/min). 2) The heart rate affected by tactile & auditory stimulus. The heart rate response was acceleration above the prestimulus level. (tactile, 231min increase, auditory ; 16∼21/min increase), and heart rate change was seen to depend on prestimulus rate. (γ=.73) 3) There was a decrease in heart rate when they were soothe. (touch ; 24.8sec, 21/min decrease, pacifier ; 14.5sec, 26/min decrease) and significant difference in time between touch and pacifier (t= 1.76, p<0.05). This result support the evaluation of newborn infant's sensory abilitics, and has even begin to influence changes in nursing care. But systemic monitoring of newborn infants response would. further define.

  • PDF

Positive Peaked Electrically Compound Action Potentials in Cochlear Implant Recipients (인공와우 이식자에서 Positive Peaked 청신경 복합활동전위)

  • Heo, Seung-Deok
    • Phonetics and Speech Sciences
    • /
    • v.1 no.2
    • /
    • pp.25-30
    • /
    • 2009
  • Animal experiments have shown that the positive peaked electrically compound action potentials (ECAPs) can be recorded in round window, intracochlear, and nerve trunk by stimulating a monopolar pulse. However, positive peaked ECAPs of cochlear implant recipients have never been reported because ECAPs are recorded from intracochlear electrodes after bipolar stimulation. In our experiment, the positive peaked ECAPs were recorded from 18 intracochlear electrodes in cochlear implant recipients with multiple cochlear anomalies. Thresholds in each channel were measured and the latency of P-, N-wave, and amplitude of P-N were analyzed. These results were identical with the electrically auditory brainstem response (EABR) on the input-output characteristics. In conclusion, the positive peaked ECAPs from the cochlear implant recipients are antidromic ECAPs recorded by perimodiolar electrodes stimulating cochlear implants with multiple anomalies. Therefore, positive peaked ECAPs can be used as useful audiological tools to evaluate the eighth nerve ending.

  • PDF

A Study on the Correlation between Visual and Auditory Emotion (시각과 청각 자극에 의한 감성정보의 연관성에 관한 연구)

  • Han, B.H.;Kim, J.H.;Kim, N.G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.27-30
    • /
    • 1997
  • The purpose of this study is to estimate human sensibility quantitatively under color and music stimulation and to examine the correlation between visual and auditory emotion. We measured biological signals such as EEG, ECG, skin conductance and the number of respiration in order to compare color with music sensibilities. Our result showed that red, yellow and violet color provoked active and exciting senses dominatively as dance, rock and blues music. While blue, cyan and pink color were involved in tranquil and resting emotions deeply as classic and ballade music. Our quantitative estimations of human sensibilites are useful in the design of manufactured goods.

  • PDF

Effects of Auditory Stimuli Using Pop Music on EEG (대중음악이 뇌파에 미치는 영향)

  • 이동형;남경돈;최현재
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2000.11a
    • /
    • pp.261-267
    • /
    • 2000
  • The purpose of this study is to analyze the effects of the auditory stimulation using pop music on EEG. The subjects in the study were eight healthy university students; five men and three women, age group of 22-28 years old. EEGs were measured for one minute at 19 channels, according to the international 10-20 system method, after both pop musics which the subject likes and not were provided with 100% and 50% volume of standard value, respectively, and the ratio of $\beta$/$\alpha$ was obtained. As a result, when the subjects heard their favorite music, the values of $\beta$/$\alpha$ ratio at the Right-Parietal.Temporal.Occipital lob(T6, O2) showed to be lower than stable state in the situation with 50% volume of standard value.

  • PDF

Virtual displays and virtual environments

  • Gilkey, R.H.;Isabelle, S.K.;Simpson, B.B.
    • Journal of the Ergonomics Society of Korea
    • /
    • v.16 no.2
    • /
    • pp.101-122
    • /
    • 1997
  • Our recent work on virtual environments and virtual displays is reviewed, including our efforts to establish the Virtual Environment Research, Interactive Technology, And Simulation (VERITAS) facility and our research on spatial hearing. VERITAS is a state-of -the-art multisensory facility, built around the ${CAVE}^{TM}$ technology. High-quality 3D audio is included and haptic interfaces are planned. The facility will support technical and non-technical users working in a wide variety of application areas. Our own research emphasizes the importance of auditory stimulation in virtual environments and complex display systems. Experiments on auditory-aided visual target acquistion, sensory conflict, sound localization in noise, and loxalization of speech stimuli are discussed.

  • PDF

A Study of the Effect of Acoustic Noise Attenuator on Auditory Functional MRI (소음 감쇠기를 이용한 청각의 뇌기능 자기공명영상)

  • Kim, S.H.;Kim, I.S.;Lee, J.J.;Park, J.A.;Lee, Y.J.;Yeo, J.R.;Bae, S.J.;Lee, S.H.;Chang, Y.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.9 no.2
    • /
    • pp.134-139
    • /
    • 2005
  • Purpose : To evaluate the usefulness of acoustic noise attenuator on auditory fMRI examination. Materials and methods : The acoustic noise attenuator consists of mask, earmuff and silicon earplug. The soft polyurethane sheet and polyurethane form , which has a good soundproof characteristic were used for mask and earmuff. Auditory fMRI experiments of 500 Hz pure tone stimulation were performed in three different cases; first all of mask, earmuff and earplug, secondly earmuff and earplug only and finally without attenuator in 4 normal hearing volunteers. For data acquisition, BOLD MR imaging technique was employed at a 1.5T MR scanner equipped with high performance gradient system. The raw data were analyzed using a SPM-99 analysis software and the activation maps were obtained. Results : In case of all items of acoustic attenuator used, the results revealed that activation was focused on primary auditory area. When only earmuff and earplug were used, the results showed that the activation spread over primary auditory and secondary associative areas. Last, when no device used, only weak activation was observed on the right auditory cortex. Conclusion : It is expected that the acoustic noise attenuator, which consists of earplugs, earmuffs and mask, is a very useful device in auditory fMRI study.

  • PDF

Multi-Channel Analog Front-End for Auditory Nerve Signal Detection (청각신경신호 검출 장치용 다중채널 아나로그 프론트엔드)

  • Cheon, Ji-Min;Lim, Seung-Hyun;Lee, Dong-Myung;Chang, Eun-Soo;Han, Gun-Hee
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.1
    • /
    • pp.60-68
    • /
    • 2010
  • In case of sensorineural hearing loss, auditory perception can be activated by electrical stimulation of the nervous system via electrode implanted into the cochlea or auditory nerve. Since the tonotopic map of the human auditory nerve has not been definitively identified, the recording of auditory nerve signal with microelectrode is desirable for determining the tonotopic map. This paper proposes the multi-channel analog front-end for auditory nerve signal detection. A channel of the proposed analog front-end consists of an AC coupling circuit, a low-power 4th-order Gm-C LPF, and a single-slope ADC. The AC coupling circuit transfers only AC signal while it blocks DC signal level. Considering the bandwidth of the auditory signal, the Gm-C LPF is designed with OTAs adopting floating-gate technique. For the channel-parallel ADC structure, the single-slope ADC is used because it occupies the small silicon area. Experimental results shows that the AC coupling circuit and LPF have the bandwidth of 100 Hz - 6.95 kHz and the ADC has the effective resolution of 7.7 bits. The power consumption per a channel is $12\;{\mu}W$, the power supply is 3.0 V, and the core area is $2.6\;mm\;{\times}\;3.7\;mm$. The proposed analog front-end was fabricated in a 1-poly 4-metal $0.35-{\mu}m$ CMOS process.

The Effects of Rhythmic Auditory Stimulation (RAS) on Hemiplegia Patient' Gait (리듬적 청각자극이 편마비환자들의 보행에 미치는 영향)

  • Kim, Tae Youn
    • Journal of Music and Human Behavior
    • /
    • v.5 no.1
    • /
    • pp.1-17
    • /
    • 2008
  • The purpose of this study is to examine how rhythmic auditory stimulation (RAS), one of music therapy techniques for neurological rehabilitation, affects the factors of hemiplegia patients' turning gait and straight gait. This study is designed to compare elimination and intervention of music therapy for 4 weeks with repeated measure plan and measure factors are classified into 21 sub-factors. The subjects of this study were 4 patients who need walking training and they were requested by physical therapist a march and a lied were used to cure them by a researcher. Each session was composed of warming up, RAS gait training, ending. The music used for RAS gait training was provided with speed which was set to patient's own gait speed measured before music therapy. The speed was provided fast gradually and each session was proceeded for 50 minutes. The results of this study showed that walking abilities increase in the segments with music therapy (B) compared to those in the segment without music therapy (A), and this supports the previous report that the application of music therapy together with other treatments has a positive effect on improvement in the patient's walking abilities. In addition, this study is meaningful in that it demonstrated that RAS music therapy is helpful to improve walking abilities not only in straight gait but also in turning gait.

  • PDF

An Analysis of Research Using the Rhythmic Auditory Stimulation Technique: A Comparison of Music Therapy and Physical Therapy Approaches (국내 리듬청각자극(RAS) 기법 활용 연구 분석: 음악치료와 물리치료 비교를 중심으로)

  • Lee, Jiyeon
    • Journal of Music and Human Behavior
    • /
    • v.17 no.1
    • /
    • pp.71-96
    • /
    • 2020
  • The purpose of this study was to identify research that included the rhythmic auditory stimulation (RAS) technique and to compare this body of research within the field of music therapy with that in physical therapy. Forty-five studies were identified that were published from January 1999 through November 2018, and these were analyzed in terms of intervention procedure, type of rhythmic cueing, and therapeutic basis described by the researcher. While research in both fields used rhythmic cueing as the primary therapeutic agent, differences were found in the area targeted by training and specific type of rhythmic cueing used. Research conducted in the field of music therapy focused primarily on gait function, while research in the field of physical therapy tended to address gait-related physical issues, such as balance, muscle strength, and proprioceptive sensation as well as gait. While all of the identified studies from the field of music therapy used music for cueing, a metronome was used more often for cueing in physical therapy research. In terms of description of theoretical basis, theory of entrainment was more sufficiently described in music therapy research. These results indicate that while music therapy research maximized the role of various elements of music in intervening in gait function, physical therapy research addressed gait in relation to other physical functions. Considering that both aspects are essential for gait training, this study supports the need for a multidisciplinary approach to neurological rehabilitation with RAS.