난연성 폴리 올레핀 케이블 절연재료의 내화특성 (Fire Resistance Characteristics of Polyolefin cable Insulating Materials for Flame Retardant)

  • 윤헌주;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.251-254
    • /
    • 2001
  • In this paper, we analysed the properties change of electric wire when the thermal stress was applied to NFR-8 and FR-PVC [600] wire. Measurement is made of the attenuation of a light beam by smoke accumulating with in a closed chamber due to nonflamining pyrolytic decomposition and flaming combustion. Results are expressed in terms of specific optical density which is derived from a geometrical factor and the measured optical density a measurement characteristic of the concentration of smoke. Referenced documents were ASTM E662 standard test method for specific Ds generated by solid materials. The furnace control system shall maintain the required irradiance level under steady-state condition with the chamber door closed of 2.5${\pm}$0.04[w/$\textrm{cm}^2$] for 20 min. According to the results of the smoke density analysis of NFR-8 and FR-PVC the highest decomposition flaming smoke density range of NFR-8 and FR-PVC were 7.2 to 77.5 and 51.1 respectively. Nonflaming smoke density range of NFR-8 and FR-PVC were 100.4 to 112.2 and 126.5 to 398.8. The amount of carbon monoxide generated was found to be much higher in FR-PVC decomposition than in NFR-8 due to incomp1ete combustion of FR-PVC which has high content of carbon in compound.

  • PDF

생체발광영상에서 포톤 검출 정량화를 위한 보정기법의 개발 (Development of Correction Technologies for Quantification of Photon Measurement in Bio-Luminescence Image)

  • 탁윤오;김현식;박형주;최흥국;최은서;한수욱;이병일
    • 대한의용생체공학회:의공학회지
    • /
    • 제32권2호
    • /
    • pp.85-92
    • /
    • 2011
  • Bioluminescence imaging (BLI) is the most sensitive animal imaging technique for molecular imaging research. Generally, highly sensitive CCD is used to detect an optical probe introduced in a living mouse. However, in many cases, the light signal emitted from a probe is too small to detect because it is scattered and attenuated by the tissue prior to being detected. The problem is that scattering and attenuation not only inhibit accurate measurement but also make image quality down. Thus we introduced a new method to reduce noise by using property of CCD and method to improve image quality of bioluminescence image by using two steps Gaussian blurring.

슬라이딩 모드를 이용한 견실한 추정기설계 (Design of Robust Estimator using Sliding Mode)

  • 윤병도;김윤호;김춘삼;김찬기;한재혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 B
    • /
    • pp.784-786
    • /
    • 1993
  • Recently, in the industrial applications, the sensorless system is developed, but the sensorless system is required to have robustness for the measurement noise and disturbance. In this paper, for the sensorless system, the method of designing a robust sliding mode observer taking account of the ability of disturbance and noise attenuation is presented. Also, the strategy for the estimation of rotor flux using the sliding mode observer, which is robust to the measurement noise, is described. Robustness are achieved by assigning the pole of the the system during the sliding motion in such a way as to minimize the effects of the disturbances on the rotor flux estimation error. Finally, using worst case desist and LQC(least square error design), the sliding mode absolver is verified by computer simulations.

  • PDF

A STUDY OF HYDRAULIC PROPERTIES IN A SINGLE FRACTURE WITH IN-PLANE HETEROGENEITY: AN EVALUATION USING OPTICAL MEASUREMENTS OF A TRANSPARENT REPLICA

  • Sawada, Atsushi;Sato, Hisashi
    • Nuclear Engineering and Technology
    • /
    • 제42권1호
    • /
    • pp.9-16
    • /
    • 2010
  • Experimental examinations for evaluating fracutres were conducted by using transparent replicas of a single fracture in order to obtain the fracture data to contribute to the methodlogy on how to improve the definitaion of representative parameter values used for a parallel plate fracture model. Quantitative aperture distribution and quantitative tracer concentration data at each point in time were obtained by measuring the attenuation of transmitted light through the fracture in high spatial resolution. the representative aperture values evaluated from the multiple different measurement methods, such as arithmetic mean of aperture distribution measured by the optical method, transport aperture evaluated from the tracer test, and average aperture evaluated from the fracture void volume measurement converged to a unique value that indicates the accuracy of this experimental study. The aperture data was employed for verifying the numerical simulation under the assuption of Local Cubic Law and showed that the calculated flow rate through the fracture is 10%-100% larger than hydraulic test results. The quantitative tracer concentration data is also very valuable for validating existing numerical code for advection dispersion transport in-plane heterogeneous fractures.

레이저 유도 초음파 및 자기보상 기법을 이용한 재료의 표면균열 깊이 비파괴 평가 (Evaluation of Depth of Surface-breaking Slit by Nondestructive Self-calibrating Technique Using Laser Based Ultrasound)

  • 이준현;최상우;하상봉
    • 대한기계학회논문집A
    • /
    • 제26권4호
    • /
    • pp.745-753
    • /
    • 2002
  • It is required to evaluate nondestructively the crack depth of surface-breaking cracks for the assurance of safety of structure. Optical generation of ultrasound produces well defined pulses with a repeatable frequency content, that are free of any mechanical resonances; they are broad band and are ideal for the measurement of attenuation and scattering over a wide frequency range. Self-calibrating surface signal transmission measurement is very sensitive and practical tool for surface-breaking crack depth. In this paper, the self-calibrating technique by laser-based ultrasound is used to evaluate the depth of surface-breaking crack of material. It is suggested that the relationship between the signal transmission and crack depth can be used as a practical model for predicting the surface-breaking crack depths from the signal transmission measured in structure.

석조문화유산의 표면 요철도에 적합한 초음파 탐촉자 및 접촉매질 선정 연구 (A Study on Selection of Ultrasonic Transducer and Contact Material for Surface Irregularities of Stone Cultural Heritage)

  • 조영훈;이찬희
    • 보존과학회지
    • /
    • 제31권3호
    • /
    • pp.267-278
    • /
    • 2015
  • 이 연구에서는 석조문화유산의 표면 요철도를 고려한 맞춤형 초음파 측정법을 설정하기 위해 새로운 접촉매질인 엘라스토머 커버를 개발하였다. 이 커버는 17MPa의 인장강도와 625%의 신장도를 가져 탄성력이 매우 우수하고 마모되지 않는 특징이 있다. 또한 엘라스토머 커버를 포함하여 탐촉자 및 접촉매질에 따른 7개 유형의 비교 실험 결과, 암석의 표면 거칠기는 초음파속도 감쇠에 많은 영향을 끼쳤다. 이러한 현상은 잔다듬에서 정다듬으로 갈수록, 직접전달방법보다는 간접전달방법에서 두드러졌다. 그러나 지수형 탐촉자와 엘라스토머 커버를 사용하는 유형 F는 요철도에 큰 상관없이 안정된 초음파속도와 높은 첨두치를 나타냈다. 이는 접촉매질로 사용한 엘라스토머 커버가 요철 표면에 충분히 밀착되어 탐촉자와 시편 사이의 공극을 제거했기 때문이다. 따라서 석조문화유산의 초음파 측정은 유형 F를 사용하는 것이 가장 적합할 것으로 판단된다.

Out-of-Band Measurement of LED-based Solar Blind UV Filters

  • Cui, Muhan;Zhou, Yue;Chen, Xue;Yan, Feng;Zhang, Mingchao;Yang, Huaijiang
    • Journal of the Optical Society of Korea
    • /
    • 제18권3호
    • /
    • pp.244-250
    • /
    • 2014
  • Due to the difficulty in measuring very low out-of-band cutoff depths of solar blind UV filters, we propose a cutoff depth adjustable measurement system (CDAM) to test deep cutoff filters with a large dynamic range. The CDAM utilizing the substitution method is elaborately composed of several parts, including narrow-band LED light sources, standard reflective neutral attenuators with known attenuation coefficients, and a photomultiplier (PMT). This paper also presents an attenuator combination method ensuring that the PMT works within its linear response range. In addition, numerical simulation testifies to the method, and experiment shows that the CDAM system can achieve an extension of dynamic range from 0-6 OD to 0-10 OD, which is sufficient for the measurement of out-of-band cutoff depths of solar blind UV filters. Above all, the CDAM system, being easily implemented, of wide dynamic range, and highly precise, could be widely used in the measurement of filter cutoff depth.

초고층 건물에 적용 가능한 건식벽체의 차음성능 평가 (An Evaluation on the Sound Insulation Performance of Drywall for High-Rise Buildings)

  • 이상우;유호천;이수열;정갑철;정영민
    • KIEAE Journal
    • /
    • 제7권2호
    • /
    • pp.3-8
    • /
    • 2007
  • Recently, the structural system of public residential buildings has been changed from the reinforced concrete (RC) wall system to the (PC) wall and moment resisting systems. Thus, it is important to develop the suitable wall system in accordance with the trend of the modern structural system. This paper presents the basic study on the suitable boundary wall in high-rise buildings. The research also demonstrates the evaluation results on sound characteristics in the aspect of sound insulation. The evaluation of sound insulation capability for the commercialized wall structure was conducted based on literature survey while the measurement of sound insulation capability for the light-weght EPP concrete was performed in according to KS F2808 in laboratory. The main objective of this research is to propose the most suitable dry wall system as a sound insulation structure through the comparison and analysis of frequency characteristics and weight-acoustic attenuation.

구립자층내의 복사에너지 감쇠량계측의 불확정성에 관한 연구 (Uncertainty in the Measurement of Radiative Energy Attenuation through Packed Spheres)

  • 김춘식;김경근;김용모
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제15권5호
    • /
    • pp.23-29
    • /
    • 1991
  • Uncertainty is studied in the measurements of average packing density, thickness of packed spheres and transmittance in the experiments to study the effect of the bed height and the existence of the bed side walls on the transmittance of radiative energy through packed spheres. The packing density of the bed is obtained by counting the number of the spheres packed in three pipes with different heights. The bed height of the packed spheres is estimated from the number of spheres contained in the bed by using the relation between the bed height and the sphere number. The transmittance is obtained by dividing the intensity of the transmitted laser beam by the incoming-beam intensity. From the analysis, the uncertainity in the measurements of transmittance is shown to be less than 10.2%(95% coverage).

  • PDF

초음파신호해석을 이용한 단순겹치기 접착이음의 강도평가 (Strength Evaluation of Adhesively Bonded Single-Lap Joints by Ultrasonic Signal Analysis)

  • 오승규;장철섭;한준영;이원
    • Journal of Welding and Joining
    • /
    • 제22권5호
    • /
    • pp.32-37
    • /
    • 2004
  • Application of bonding by adhesives can be found in many industries, particularly in advanced technological domains such as aeronautical and space, automobile and electronics industries. Periodic inspection with conventional ultrasonic NDE techniques is capable of indicating the presence and possible location of crack. Continuous ultrasonic attenuation monitoring has potential to supply information. This article discusses the use of pulse-echo ultrasonic testing for the inspection of adhesive bonds between metal sheets. The method is based on the measurement of the reflection coefficient at the metal/adhesive interface. By means of a control experiment it is shown that Quantitative Nondestructive Evaluation in Adhesive Joints are evaluated together with Ultrasonic Testing and Fracture Testing.