• Title/Summary/Keyword: attenuation correction

Search Result 185, Processing Time 0.033 seconds

The Consideration for Optimum 3D Seismic Processing Procedures in Block II, Northern Part of South Yellow Sea Basin (대륙붕 2광구 서해분지 북부지역의 3D전산처리 최적화 방안시 고려점)

  • Ko, Seung-Won;Shin, Kook-Sun;Jung, Hyun-Young
    • The Korean Journal of Petroleum Geology
    • /
    • v.11 no.1 s.12
    • /
    • pp.9-17
    • /
    • 2005
  • In the main target area of the block II, Targe-scale faults occur below the unconformity developed around 1 km in depth. The contrast of seismic velocity around the unconformity is generally so large that the strong multiples and the radical velocity variation would deteriorate the quality of migrated section due to serious distortion. More than 15 kinds of data processing techniques have been applied to improve the image resolution for the structures farmed from this active crustal activity. The bad and noisy traces were edited on the common shot gathers in the first step to get rid of acquisition problems which could take place from unfavorable conditions such as climatic change during data acquisition. Correction of amplitude attenuation caused from spherical divergence and inelastic attenuation has been also applied. Mild F/K filter was used to attenuate coherent noise such as guided waves and side scatters. Predictive deconvolution has been applied before stacking to remove peg-leg multiples and water reverberations. The velocity analysis process was conducted at every 2 km interval to analyze migration velocity, and it was iterated to get the high fidelity image. The strum noise caused from streamer was completely removed by applying predictive deconvolution in time space and ${\tau}-P$ domain. Residual multiples caused from thin layer or water bottom were eliminated through parabolic radon transform demultiple process. The migration using curved ray Kirchhoff-style algorithm has been applied to stack data. The velocity obtained after several iteration approach for MVA (migration velocity analysis) was used instead or DMO for the migration velocity. Using various testing methods, optimum seismic processing parameter can be obtained for structural and stratigraphic interpretation in the Block II, Yellow Sea Basin.

  • PDF

Application of Gamma Ray Densitometry in Powder Metallurgy

  • Schileper, Georg
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2002.07a
    • /
    • pp.25-37
    • /
    • 2002
  • The most important industrial application of gamma radiation in characterizing green compacts is the determination of the density. Examples are given where this method is applied in manufacturing technical components in powder metallurgy. The requirements imposed by modern quality management systems and operation by the workforce in industrial production are described. The accuracy of measurement achieved with this method is demonstrated and a comparison is given with other test methods to measure the density. The advantages and limitations of gamma ray densitometry are outlined. The gamma ray densitometer measures the attenuation of gamma radiation penetrating the test parts (Fig. 1). As the capability of compacts to absorb this type of radiation depends on their density, the attenuation of gamma radiation can serve as a measure of the density. The volume of the part being tested is defined by the size of the aperture screeniing out the radiation. It is a channel with the cross section of the aperture whose length is the height of the test part. The intensity of the radiation identified by the detector is the quantity used to determine the material density. Gamma ray densitometry can equally be performed on green compacts as well as on sintered components. Neither special preparation of test parts nor skilled personnel is required to perform the measurement; neither liquids nor other harmful substances are involved. When parts are exhibiting local density variations, which is normally the case in powder compaction, sectional densities can be determined in different parts of the sample without cutting it into pieces. The test is non-destructive, i.e. the parts can still be used after the measurement and do not have to be scrapped. The measurement is controlled by a special PC based software. All results are available for further processing by in-house quality documentation and supervision of measurements. Tool setting for multi-level components can be much improved by using this test method. When a densitometer is installed on the press shop floor, it can be operated by the tool setter himself. Then he can return to the press and immediately implement the corrections. Transfer of sample parts to the lab for density testing can be eliminated and results for the correction of tool settings are more readily available. This helps to reduce the time required for tool setting and clearly improves the productivity of powder presses. The range of materials where this method can be successfully applied covers almost the entire periodic system of the elements. It reaches from the light elements such as graphite via light metals (AI, Mg, Li, Ti) and their alloys, ceramics ($AI_20_3$, SiC, Si_3N_4, $Zr0_2$, ...), magnetic materials (hard and soft ferrites, AlNiCo, Nd-Fe-B, ...), metals including iron and alloy steels, Cu, Ni and Co based alloys to refractory and heavy metals (W, Mo, ...) as well as hardmetals. The gamma radiation required for the measurement is generated by radioactive sources which are produced by nuclear technology. These nuclear materials are safely encapsulated in stainless steel capsules so that no radioactive material can escape from the protective shielding container. The gamma ray densitometer is subject to the strict regulations for the use of radioactive materials. The radiation shield is so effective that there is no elevation of the natural radiation level outside the instrument. Personal dosimetry by the operating personnel is not required. Even in case of malfunction, loss of power and incorrect operation, the escape of gamma radiation from the instrument is positively prevented.

  • PDF

Characteristics of 23 MV Photon Beam from a Mevatron KD 8067 Dual Energy Linear Accelerator (Mevatron KD 8067 선형가속기의 23 MV 광자선의 특성)

  • Kim, Ok-Bae;Choi, Tae-Jin;Kim, Young-Hoon
    • Radiation Oncology Journal
    • /
    • v.8 no.1
    • /
    • pp.115-124
    • /
    • 1990
  • The characteristics of 23 MV photon beam have been presented with respect to clinical parameters of central axis depth dose, tissue-maxi mum ratios, scatter-maximum ratios, surface dose and scatter correction factors. The nominal accelerating potential was found to be $18.5\pm0.5$ MV on the central axis. The half-value layer (HVL) of this photon beam was measured with narrow beam geometry from central axis, and it has been showed the thickness of $24.5\;g/cm^2$. The tissue-maximum ratio values have been determined from measured percentage depth dose data. In our experimental dosimetry, the surface dose of maximum showed only $9.6\%$ of maximum dose at $10\times10\;cm^2$, 100 cm SSD, without blocking tray in. The TMR'S of $0\times0$ field size have been determined to get average $2.3\%$ uncertainties from three different methodis; are zero effective attenuation coefficient, non-ilnear least square fit of TMR's data and effective linear attenuation coefficient from the HVL of 23 MV photon beams of dual energy linear accelerator.

  • PDF

The comparative analysis of KOMPSAT-3 based surface normalized difference vegetation index: Application of GeoEye data (다목적실용위성 3호의 지표 정규식생지수 산출 및 비교 분석: GeoEye 자료 활용)

  • Yeom, Jong-Min
    • Aerospace Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.80-86
    • /
    • 2014
  • In this study, we the estimated surface normalized difference vegetation index by using the KOrea Multi-Purpose SATellite-3 (KOMPSAT-3) multi-spectral images for comparative analysis. The estimated NDVI from KOMPSAT-3 is used as for comparison with the high resolution GeoEye products. The geometry conditions for atmospheric effects are selected from meta files of KOMPSAT-3 bundle data. The used geometry conditions are consist of solar zenith angle, solar azimuth angle, viewing zenith angle, viewing azimuth angle, and date. And, Atmospheric effects such as attenuation, scattering and absorption were physically simulated from water vapor, ozone and aerosol information. Generally, although ground measurements are important for accurate information, in this study, MODIS atmospheric products are used as atmospheric constituents. The surface reflectance from radiative transfer model is utilized for estimating vegetation index. The present study, to reduce atmospheric and geometry conditions between KOMPSAT-3 and GeoEye having difference observation characteristics, data acquisition time is carefully determined for reliable vegetation spectral characteristics.

Compensation of Aethalometer Black Carbon Data Observed at a Gwangju Site (광주 도심지역에서 측정한 Aethalometer 검댕입자 자료의 보정)

  • Park, Seung-Shik;Jung, Jung-H.;Cho, Sung-Y.;Kim, Seung-Jai
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.25 no.6
    • /
    • pp.571-578
    • /
    • 2009
  • $PM_{2.5}$ black carbon (BC) concentrations were measured to investigate the filter spot loading effect in raw BC data at 5-minute time-based resolution using a single-wavelength aethalometer at a Gwangju site. Also the elemental carbon (EC) concentrations from 24-hr integrated filter-based measurements of $PM_{2.5}$ particles were determined to compare with the loading compensated BC values. Close examination of the time-series BC data showed clearly the "gaps" when the filter tape advances, suggesting the correction of raw BC data. Therefore, we calculated the average BC concentration in each range of attenuation (ATN) to decide if there was (or was not) an effect on the aethalometer data according to the loading of the filter spot. A consistent decrease of average BC concentration was found with increasing ATN values for every month, suggesting there was a consistent "spot loading effect" in the raw BC data. The loading compensated BC concentration according to a simple compensation model with loading effect was 1.01~1.15 times greater than the raw BC data. The 24-hr average concentration of EC observed during summer sampling period was about 3% higher than the original 24-hr average BC value and 2% lower than the loading compensated BC concentration.

The design and performance analysis of RS(255,223) code for X-band downlink of STSAT-3 (과학기술위성3호의 X-대역 하향링크를 위한 RS(255,223) 코드 설계 및 성능 분석)

  • Seo, In-Ho;Kim, Byung-Jun;Lee, Jong-Ju;Kwak, Seong-Woo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.2
    • /
    • pp.195-199
    • /
    • 2010
  • (255,223) RS(Reed-Solomon) code which is the CCSDS(Consultative Committee for Space Data Systems) standard was used in the STSAT-3 to correct errors during the downlink of payload data. The RS encoder developed by VHDL was implemented in MMU(Mass Memory Unit). Moreover, the RS decoder developed by C-language was implemented in the DRS(Data Receiving System) of ground station. In this paper, we reported the design and analysis results of RS(255,223) for STSAT-3. The BER(Bit Error Rate) performance from MMU to DRS was confirmed through the downlink test at 16 Mbps. Also, the error correction performance and capability of RS(255,223) was tested by the manual attenuation of the RF(Radio Frequency) signal in the X-band transmitter resulting in putting some errors in the communication line.

Density Profile Measurement of Needle-punched Carbon/Carbon Nozzle Throat by the Analysis of Computed Tomography Image (전산화 단층촬영 영상 분석에 의한 탄소/탄소 목삽입재의 밀도 분포 측정)

  • Kim Dong-Ryun;Yun Nam-Gyun;Lee Jin-Yong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.469-474
    • /
    • 2005
  • Tn this study, the noll-destructive computed X-ray tomography was adopted to observe the density distribution of the needle-punched C-C composites nozzle throat. The density distribution of the C-C was evaluated within ${\pm}0.01g/cm^3$ with 98.74% confidence when the correction of the image and high signal-to-noise ratio were achieved by the optimization of the beam hardening, the electrical noise and the scattered X-ray. The density variation of the C/C with the computed tomography was in good agreement with the results obtained by the water immersion method and the observation with scanning electron microscope.

  • PDF

Changes in the Standardized Uptake Value According to the Type of Metal of Dental Prosthesis in PET-CT Fusion Image (PET-CT 융합 영상에서 치과보철물의 금속 종류에 따른 표준섭취계수 값의 변화)

  • Han, Sang-Hyun
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.9
    • /
    • pp.117-122
    • /
    • 2018
  • In this study, HU(hounsfield unit) value of CT generated by dental prosthesis was measured according to the type of metal when PET-CT was performed, and the degree of distortion and standard deviation of SUV(standard uptake value) and to propose a method to reduce errors in image reading. PET-CT was performed using actual teeth, metal crown, gold crown, titanium, and zirconia dental prosthesis. Compared with general teeth, the SUV value increased with increasing HU value. The SUV value of metal crown, titanium, and zirconia was increased by 37% and the gold crown increased by 45.4%. In addition, image distortions were small in general teeth, metal crown, titanium, and zirconia, but hard curing of the gold crown occurred and image distortion occurred. Therefore, since the metal type of the dental prosthesis affects the SUV value, the NAC(non attenuation correction) PET image of the dental prosthesis can be helpful in the diagnosis of the patient using the gold material.

A Study on Calculation of Protection Ratio for Interference Analysis in Fixed Radio Relay Networks (고정 무선중계 망의 간섭 분석을 위한 보호비 계산에 대한 연구)

  • Suh Kyoung-Whoan;Lee Joohwan
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.43 no.1 s.343
    • /
    • pp.133-142
    • /
    • 2006
  • This paper suggests an efficient method of protection ratio(PR) calculation and shows some results of point-to-point radio relay system for frequency coordination. The proposed PR can be expressed as a function of C/N of modulation scheme, noise-to-interference ratio(N/I), multiple interference allowance, fade margins of multi-Path and rain attenuation and net filter discrimination. And PR calculation is performed in view of fade margin, modulation scheme, distance, and interference for actual point-to-point radio relay frequency. According to results for 6.2 GHz, 64-QAM and 60 km at BER 10-6, fade margin and co-channel Protection ratio reveal 41.1dB and 74.9 dB, respectively The merit of presented method provides a systematic and easy calculation by means of PR correction factor related with various parameters and can apply the same concept to frequency coordination of millimeter wave radio relay system.

Multimodality Image Registration and Fusion using Feature Extraction (특징 추출을 이용한 다중 영상 정합 및 융합 연구)

  • Woo, Sang-Keun;Kim, Jee-Hyun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.12 no.2 s.46
    • /
    • pp.123-130
    • /
    • 2007
  • The aim of this study was to propose a fusion and registration method with heterogeneous small animal acquisition system in small animal in-vivo study. After an intravenous injection of $^{18}F$-FDG through tail vain and 60 min delay for uptake, mouse was placed on an acryl plate with fiducial markers that were made for fusion between small animal PET (microPET R4, Concorde Microsystems, Knoxville TN) and Discovery LS CT images. The acquired emission list-mode data was sorted to temporally framed sinograms and reconstructed using FORE rebining and 2D-OSEM algorithms without correction of attenuation and scatter. After PET imaging, CT images were acquired by mean of a clinical PET/CT with high-resolution mode. The microPET and CT images were fusion and co-registered using the fiducial markers and segmented lung region in both data sets to perform a point-based rigid co-registration. This method improves the quantitative accuracy and interpretation of the tracer.

  • PDF