• Title/Summary/Keyword: attached-type

Search Result 1,069, Processing Time 0.027 seconds

Selection of Heater Location in Linear Source for OLED Vapor Deposition (OLED 증착을 위한 선형증발원 히터 위치선정)

  • Joo, Young-Cheol;Han, Choong-Hwan;Um, Tai-Joon;Lee, Sang-Wook;Kim, Kug-Weon;Kwon, Kye-Si
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.6
    • /
    • pp.515-518
    • /
    • 2008
  • Organic light emitting diode(OLED) is one of the most promising type of future flat panel display. A linear source is used to deposite organic vapor to a large size OLED substrate. An electric heater which is attached on the side of linear source heats the organic powder for the sublimation. The nozzle of heater, which is attached at the top of the linear source has an optimal temperature. An numerical analysis has been performed to find optimal heater position for the optimal nozzle temperature. A commercial CFD program, FLUENT, is used on the analysis. Two-dimensional and three-dimensional analysis have been performed. The analysis showed that the heater should be attached at the outer side of crucible wall rather than inner side of housing, which was original design. Eighteen milimeter from the top of the linear source was suggested as the optimal position of heater. Improving thermal performance of linear source not only helps the uniformity of organic vapor deposition on the substrate but also increase productibity of vapor deposition process.

A Carbazole-Attached NO2S2-Macrocycle Exhibiting Hg2+ and Cu2+ Selectivity

  • Lee, Seul-Gi;Kang, Eun-Ju;Lee, Shim Sung
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.5
    • /
    • pp.1429-1434
    • /
    • 2013
  • A synthesis and cation-induced fluorescent behavior of the carbazole-attached $NO_2S_2$-macrocycle (L) is described and structurally characterized by single crystal X-ray analysis. The photoluminescence spectrum of L in 80% $CH_3CN/CH_2Cl_2$ displays a peak maximum at 431 nm (blue emission). In the metal-induced fluorometric experiment, L showed a drastic chelation-enhanced fluorescence quenching (CHEQ) effect only with $Hg^{2+}$ and $Cu^{2+}$. In ESI-mass study, a 1:1 stoichiometry for complexation of L with $Hg^{2+}$ was confirmed, suggesting the unique sensing behavior of the proposed ligand L due to the selective complexation affinity for $Hg^{2+}$. The observed results indicate that L is a promising turn-off type fluoroionophore for $Hg^{2+}$ and $Cu^{2+}$ detections. Additionally, the $Ag^+$ complex of the precursor macrocycle was prepared and its solid structure was crystallographically characterized.

Improvement of Reflection Angle of Optical Scanner Utilizing Magnetic Effect (자기효과를 이용한 광 Scanner의 반사각 개선)

  • Kim, Hung-Gun;Park, Kyung-Il;Shin, Kwang-Ho;SaGong, Geon
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1718-1720
    • /
    • 2004
  • This paper is focused on the improvement of reflection angle of an optical scanner by changing a shape of a torsion bar attached with an optical scanner reflector(mirror). In order to improve the light efficiency of the optical scanner by virtue of the magnetic effect, which tiny magnets are attached under both ends of the optical scanner reflector. and hence the optical scanner reflector was operated in relatively lower driving voltage. By changing the torsion bar's shape I type into S type, we've got the lower resonant frequency(32.5Hz) of an optical scanner than that of conventional one(50Hz). According to these results. The reflection angle of an optical scanner with magnets was much larger in the range of about 14.8$^{circ}$ without a magnet. By making use of a magnetic actuator instead of a conventional electrostatic actuator, the optical scanner was less influenced from outdoor dust or moisture.

  • PDF

A Study on the Chip Control in Machining STS304 Using a Chip Breaker (STS304잘삭시 Chip Breaker를 이용한 Chip제어에 관한 연구)

  • Yeom, D.W.;Yu, K.H.;Seo, N.S.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.11 no.6
    • /
    • pp.42-49
    • /
    • 1994
  • One of the parameters that influence the productivity of every industry, involved in metal cutting, is the chip from ; continuous or broken chip. Chip form varies according to machining conditions, material used, tool geometry and chip breaker geometry. Therefore, in this study we carried out the experiment on the chip control in machining STS304 using an attached obstruction type chip breaker. Namely, with the change of a chip breaker distance, chip breaker angle, cutting characteristics in machining STS304 which is well-known as a machining difficult material and produces a saw-toothed chip. The results of the experiment are as follows : 1. The chip breaker distance and angle under which the preferred chip is produced, show 1.5mm and 60 .deg. , while chip breaker angle in machining an ordinary steel was well-known 45 .deg. . 2. During the cutting process, the change of feed than the change of velocity was applied as cutting conditions, effects more clearly on the chip breaking. 3. Considering a whole surface roughness, it is not advisable to apply chip breaker mentioned above for precision cutting.

  • PDF

Comparison of internal porosity of dental titanium castings with different casting machines (주조방식에 따른 티타늄 주조체의 내부결함 비교)

  • Lee, Kyung-Eun;Kim, Bu-Sob;Chung, In-Sung
    • Journal of Technologic Dentistry
    • /
    • v.29 no.2
    • /
    • pp.129-140
    • /
    • 2007
  • The purpose of this study was to evaluate the titanium castability (internal porosity) between pressure type casting machine & centrifugal casting machine with air-vent or not. Internal porosity is a well-known problem in dental titanium casting, resulting in inferior mechanical properties of dental restorations. To evaluate the castability, the square plate was chosen. 40 plate patterns($20{\times}20{\times}1.8mm$)were attached to funnel-shaped sprue. Then 20 plate patterns were attached air-vent. They were invested in titanium investment material and cast in a pressure type casting machine(20castings) and centrifugal casting machine(20castings). Each group were divided with air-vent(10castings) or not(10castings). The titanium castings were evaluated by radiographic photograph for the location of the internal porosities. The percentage porosity of each specimen was determined using standardized digital radiographs. The results were analyzed with analysis of variance and t-test for paired comparison between two groups.

  • PDF

Development of Attachable HOB Monitoring System with Performance Analysis (부착형 침상머리 각도 모니터링 시스템 개발 및 성능 분석)

  • Gyeong, G.Y.;Park, Y.S.;Lee, Y.S.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.8 no.3
    • /
    • pp.197-203
    • /
    • 2014
  • In this paper, we develop an attachable head of bed(HOB) monitoring system, which can prevent ventilator associated pneumonia(VAP), and analyze the performance of the developed HOB monitoring system. The main purpose of the HOB monitoring system is to support visible HOB display for keeping patients' position effectively and collect data for analysis of the relation between HOB elevation and patients' symptom. The HOB monitoring system is developed in attached-type and uses an FIR filter with heuristic logic to remove the unwanted noise. The optical encoder is used for the performance analysis of the developed HOB monitoring system.

  • PDF

NEAR-IR PHOTOMETRIC AND OPTICAL SPECTROSCOPIC STUDY OF THE FU ORIONIS OBJECT V582 AURIGAE

  • OH, HYUNG-IL;YOONY, TAE SEOG;SUNG, HYUN-IL
    • Publications of The Korean Astronomical Society
    • /
    • v.30 no.2
    • /
    • pp.269-270
    • /
    • 2015
  • We carried out near-IR photometric and optical spectroscopic observations of V582 Aur, which is a FU Orionis type object, to investigate any periodic and/or aperiodic variations. We obtained light curves on the scale of a night and a year, in J, H and Ks bands with KASINICS (KASI Near Infrared Camera System) attached to the BOAO (Bohyun-san Optical Astronomy Observatory) 1.8-m reflector in Youngcheon, South Korea and examined photometric variations on the two time scales. So far we have not found any periodic brightness variations on the scale of a night. On the other hand, we have found that there seems to be a periodic brightness variation with a period of approximately 45 days. In addition, high-resolution optical spectroscopic observations of V582 Aur were performed from February 2013 to May 2014 with the high-resolution echelle spectrograph BOES attached to the BOAO 1.8-m reflector. We analyzed several spectral lines to understand the physical state of V582 Aur. The P Cyg profiles are clearly shown in the $H{\alpha}$ line and Na I D line.

Development of a Robotic System for Measuring Hole Displacement Using Contact-Type Displacement Sensors (접촉식 변위센서를 이용한 홀 변위 측정 로봇시스템 개발)

  • Kang, Hee-Jun;Kweon, Min-Ho;Suh, Young-Soo;Ro, Young-Shick
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.1
    • /
    • pp.79-84
    • /
    • 2008
  • For the precision measurement of industrial products, the location of holes inside the products, if they exist, are often selected as feature points. The measurement of hole location would be performed by vision and laser-vision sensor. However, the usage of those sensors is limited in case of big change of light intensity and reflective shiny surface of the products. In order to overcome the difficulties, we have developed a hole displacement measuring device using contact-type displacement sensors (LVDTs). The developed measurement device attached to a robot measures small displacement of a hole by allowing its X-Y movement due to the contact forces between the hole and its own circular cone. The developed device consists of three plates which are connected in series for its own function. The first plate is used for the attachment to an industrial robot with ball-bush joints and springs. The second and third plates allow X-Y direction as LM guides. The bottom of the third plate is designed that various circular cones can be easily attached according to the shape of the hole. The developed system was implemented for its effectiveness that its measurement accuracy is less than 0.05mm.

Development of a Tractor Attached TMR Mixer (I) - Design of a TMR mixer and its performance test (트랙터 견인형 TMR 배합기의 개발 (I) - TMR 배합기의 설계 및 성능시험)

  • Park, K. K.;Koo, Y. M.;Kim, H. J.;Seo, S. H.;Jang, C.;Lee, J. S.;Woo, J. K.
    • Journal of Biosystems Engineering
    • /
    • v.25 no.3
    • /
    • pp.203-212
    • /
    • 2000
  • One of the obstructing factors against managing large-scaled dairy farm in Korea has been heavy labor requirement for feeding dairy cows. A tractor attached TMR mixer was developed to reduce the cost and to provide economic benefit in this research. The TMR mixer was designed to have a feeding capacity of 35 heads at a batch with various functioning systems of paddle type mixer, cutter and grinder, delivery conveyor, weighing console, power transmission train, and mounting trailer. The maximum power required during the mixing operarion was 26.3 kw(P.T.O), readily available from 32kw-rated tractors, which had been widely used in Korea. Low coefficient of variation(14.0%) revealed an uniform mixing performance of the mixer. The mixer can also be used in compost mixing as well as concentrates and roughage.

  • PDF

Exercise Recognition using Accelerometer Based Body-Attached Platform (가속도 센서 기반의 신체 부착형 플랫폼을 이용한 운동 인식)

  • Kim, Joo-Hyung;Lee, Jeong-Eom;Park, Yong-Chan;Kim, Dae-Hwan;Park, Gwi-Tae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.11
    • /
    • pp.2275-2280
    • /
    • 2009
  • u-Healthcare service is one of attractive applications in ubiquitous environment. In this paper, we propose a method to recognize exercises using a new accelerometer based body-attached platform for supporting u-Healthcare service. The platform consists of a device for measuring accelerometer data and a device for receiving the data. The former measures a user's motion data using a 3-axis accelerometer. The latter transmits the accelerometer data to a computer for recognizing the user's exercise. The algorithm for exercise recognition classifies the type of exercise using principle components analysis(PCA) from the accelerometer data transformed by discrete fourier transform(DFT), and estimates the repetition count of the recognized exercise using a peak detection algorithm. We evaluate the performance of the algorithm from the accuracy of the recognition of exercise type and the error rate of the estimation of repetition count. In our experimental result, the algorithm shows the accuracy about 98%.