• Title/Summary/Keyword: attached biomass

Search Result 90, Processing Time 0.024 seconds

Biological Treatability of Toxic Industrial Wastewater (독성산업폐수의 생물학적 처리)

  • 원성연;박승국;정근욱
    • Journal of environmental and Sanitary engineering
    • /
    • v.14 no.4
    • /
    • pp.172-179
    • /
    • 1999
  • In this research, biological treatability test was conduced using seawater flocculated tannery wastewater by fixed biofilm reactor. During one cycle, the removal efficiency of organic corbon obtained with fixed biofilm process for treating tannery wastewater was considerably greater than that with activated sludge process. As the hydraulic retention time increased form 0.5day to 4day, removal efficiency of organic carbon was increased from 72% to 87.3%. Attached biomass in media increased with influent organic loading up to 29g MLSS/L, that could reduce the specific organic loading rate. The continual measurement of attached biomass was possible for the operation of the biofilm reactor. Equal and low nitrication rates were observed in both suspended growth activated sludge process and fixed biofilm process, despite commercial nitrifier was seeded. Through the process of treating the tannery wastewater, EC50 values which is measured by the use of Ceriopdaphnia dubia, were decreased to the extent of 50% after treatment of seawater flocculation and of 83% after biological treatment, respectively, compared to those of the untreated wastewater.

  • PDF

Effect of Temperature on the Treatment Efficiency in Aerated Submerged Biofilm Process (호기성(好氣性) 침지형(浸漬型) 생물막공법(生物膜工法)에서 온도(溫度)가 처리효율(處理効率)에 미치는 영향(影響))

  • Park, Jong Woong;Yu, Myong Jin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.11 no.1
    • /
    • pp.189-196
    • /
    • 1991
  • The objective of this study was to investigate the effect of temperature on microbial characteristics and treatment efficiency in aerated submerged biofilm process. From the results of the research, conclusions were derived as following: 1. Biofilm density, attached biomass and biofilm thickness were $30-42mg/cm^3$, $1.2-2.7mg/cm^2$ and $380-690{\mu}m$, respectively. These were greatly affected by the variation of temperature ($5-20^{\circ}C$) and packing ratio(45-90%). 2. The ratio of suspended biomass to the total biomass in the reactor was in the range of 10 to 50 % in accordance with the variation of temperature and packing ratio. Therefore, the portion of suspended biomass cannot be neglected. 3. BOD removal efficiency increased as either temperature or biomass(suspended and attached) concentration increased. 4. The aerated submerged biofilm process appeared to be less affected by temperature variation and the estimated temperature correction coefficient of the Van't Hoff-Arrhenenius equation was 1.042.

  • PDF

A Study of Attached Biomass Back Washing in Fixed Film System (고정 생물막공법에서 부착미생물의 역세에 관한 연구)

  • 이창근;김정숙
    • Journal of Environmental Science International
    • /
    • v.6 no.3
    • /
    • pp.219-224
    • /
    • 1997
  • The cloging phenomenon in the fixed film reactor Is shown when biomass growth Is excessive for long operating time. In addition, effluent water Quality gets worse because of detachment of biomass. In this study, we conducted air-backwashing to sustain biomass In reactor to complement these defects. The results of experimental are showed In the following conclusion. The detachment rate was 19.5 - 38.0% when the organic loading rate was 0.40 - 1.32 kg COD/$m^3$/day, the k - backwashing Intensity was 2 L/min(6.7 $m^3$/$m^2$/hrl and the backwashing time was 15 - 19 seconds. And the detachment rate was 32.2 - 58.6 % when the organic loading rate was 1.37 - 2.27 kg COD/$m^2$/day, the backwashing time was 1 - 12 minutes. As orgnic loading rate and backwashing time ale Increased, detachment of fixed biomass Is Increased. The detachment equation with detachment rate(DR, %), backwashing time(BWT, min), fixed biomass concentration(FB. mg/L), and organic leading rate(OLR, kg COD/ms/day) through multiple linear regession was given by the following equation: DR : 17.964 $BWT^{0.1407} FB^{0.0597} OLR^{0.1946}$

  • PDF

Biosorption of lead by Laminaria japonica

  • Jung-Ho;Il-Bae;Hak-Sung
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2003.11a
    • /
    • pp.208-211
    • /
    • 2003
  • Characteristics of biosorption of lead by marine algae, Laminaria japonica, were examined. The biosorption capacity of lead by L. japonica was achieved up to 30% of its own weight and proportional to the initial lead concentration. However, the opposite result was shown in different initial weight of biomass. Ion exchange reaction between lead ions and calcium ions was observed on lead biosorption with Ca-Ioaded biomass. Stoichiometric coefficient, which can represent the exchange ratio between metal ions and protons during elution process, was determined as 1.39. Therefore, it was concluded that the reaction between lead ions already attached in biomass and protons in bulk solution was not fully stoichiometric ion exchange relation at elution process.

  • PDF

A comparative study of dyeing wastewater treatment capability for Aerobic Packed/Fluidized-Bed and Moving Media Complete Mixing Activated Sludge system (염색폐수 처리성능에 대한 호기성 고정 및 유동층 생물막공법과 회전매체를 가진 완전혼합 활성슬러지 공법의 비교연구)

  • 김홍태;김규창
    • Journal of Environmental Science International
    • /
    • v.8 no.4
    • /
    • pp.525-532
    • /
    • 1999
  • This study was conducted to evaluate capability of dyeing wastewater treatment for 3 type reactors. These reactors were Packed Bed Reactor(PBR), Fluidized Bed reactor(FBR) and Moving Media Complete Mixing Activated Sludge reactor(MMCMAS). Experiments of PBR and FBR were performed by various packing ratios and organic loading rates, experiments of MMCMAS were performed by various organic loading rates. In order to obtain ${SBOD}_5$ removal efficiencies of more than 90%, the F/Mv ratios of PBR, FBR, MMCMAS were 0.11 kgBOD/kgMLVSS$\cdot$d, 0.12 kgBOD/kgMLVSS$\cdot$d, and 0.37 kgBOD/kgMLSS$\cdot$d, respectively. So MMCMAS system which has more active microorganisms showed better capability of organic removal and also stronger dynamic and shock loadings than those of PBR and FBR. In PBR and FBR, the media packing ratio of 20% showed better performance of organic matters removal effciencies than 10% and 30%, but sludge production rate at media packing ratio of 30% was relatively lower than that of 10% and 20%. When more than 90% organic matters removal efficiency was obtained, the ratios of attached biomass to total biomass at PBR, FBR, MMCMAS were 89~99%, 87~98%, and 54~80%, respectively. The ratio of attached biomass to total biomass was low in MMCMAS. This was formation of thin biofilm due to shear force between rotaing disc and water. The average sludge production rates(kgVSS/kgBODrem.) of PBR, FBR and MMCMAS were 0.20, 0.29 and 0.54, respectively.

  • PDF

Analysis of Attached Bacterial Community of Biological Activated Carbon Process Using FISH (FISH 기법을 이용한 생물활성탄 공정에서의 운전기간별 부착 박테리아 군집변화 분석)

  • Son, Hyeng-Sik;Son, Hee-Jong;Park, Geun-Tae;Lee, Sang-Joon
    • Journal of Environmental Science International
    • /
    • v.22 no.1
    • /
    • pp.25-35
    • /
    • 2013
  • The concentration of organic compounds was analyzed at each step of BAC process though $BDOC_{total/rapid/slow}$. Further, bacteria communities and biomass concentrations measured FISH and ATP methods were analyzed. The bed volume (BV) of steady state is different from that of based on assessment of organic compounds removal. Bed volumes in DOC, $BDOC_{rapid}$ and $BDOC_{total/slow}$ removal at steady state were around 27,500 (185.8 day), 15,000 (101.4 day) and 32,000 (216.2 day), respectively. A biomass didn't change after the bed volume reached 22,500 (152.0 day) according to analyzing ATP concentration of bacteria. The concentration of ATP was 2.14 ${\mu}g/g$ in BV 22,500 (152.0 day). The total bacterial number was $4.01{\pm}0.4{\times}10^7$ cells/g at the bed volume 1,150 (7.8 day) (the initial operation) and the number of bacteria was $9.27{\pm}0.2{\times}10^9$ at the bed volume 58,560 395.7 day) that increased more than 200 times. Bacterial uptrend was reduced and bacterial communities were stabilized since BV 18,720 (126.5 day). When BV were 1,150 (7.8 day), 8,916 (60.2 day), 18,720 (126.5 day), 31,005 (209.5 day), 49,632 (335.3 day), 58,560 (395.7 day), a proportion of total bacteria for the Eubacteria were 60.1%, 66.0%, 78.4%, 82.0%, 81.3% respectively. ${\gamma}$-Proteobacteria group was the most population throughout the entire range. The correlation coefficient ($r^2$) between Eubacteria biomass and ATP concentration was 0.9448.

Bacterial Community Composition and Diversity of a Full-Scale Integrated Fixed-Film Activated Sludge System as Investigated by Pyrosequencing

  • Kwon, Soon-Dong;Kim, Taek-Seung;Yu, Gi-Hyeon;Jung, Joon-Hong;Park, Hee-Deung
    • Journal of Microbiology and Biotechnology
    • /
    • v.20 no.12
    • /
    • pp.1717-1723
    • /
    • 2010
  • The integrated fixed-film activated sludge (IFAS) system is a variation of the activated sludge wastewater treatment process, in which hybrid suspended and attached biomass is used to treat wastewater. Although the function and performance of the IFAS system are well studied, little is known about its microbial community structure. In this study, the composition and diversity of the bacterial community of suspended and attached biomass samples were investigated in a full-scale IFAS system using a high-throughput pyrosequencing technology. Distinct bacterial community compositions were examined for each sample and appeared to be important for its features different from conventional activated sludge processes. The abundant bacterial groups were Betaproteobacteria (59.3%), Gammaproteobacteria (8.1%), Bacteroidetes (5.2%), Alphaproteobacteria (3.9%), and Actinobacteria (3.2%) in the suspended sample, whereas Actinobacteria (14.6%), Firmicutes (13.6%), Bacteroidetes (11.6%), Betaproteobacteria (9.9%), Gammaproteobacteria (9.25%), and Alphaproteobacteria (7.4%) were major bacterial groups in the attached sample. Regarding the diversity, totals of 3,034 and 1,451 operational taxonomic units were identified at the 3% cutoff for the suspended and attached samples, respectively. Rank abundance and community analyses demonstrated that most of the diversity was originated from rare species in the samples. Taken together, the information obtained in this study will be a base for further studies relating to the microbial community structure and function of the IFAS system.

Sewage Treatment using Aerated Submerged Biological Filter(ASBF) (호기성 침지형 생물막 여과장치를 이용한 오수처리)

  • Park, Jong-Woong;Song, Ju-seok
    • Journal of Korean Society on Water Environment
    • /
    • v.16 no.4
    • /
    • pp.523-532
    • /
    • 2000
  • The purpose of this study was to investigate the effects of the hydraulic retention time (HRT) and organic loading rate (OLR) on microbial characteristics and treatment efficiency in sewage treatment using aerated submerged biological filter (ASBF) reactor. This reactor combines biodegradation of organic substrates by fixed biomass with a physical separation of biomass by filtration in a single reactor. Both simulated wastewater and domestic wastewater were used as feed solutions. The experimental conditions were a temperature of 17 to $27^{\circ}C$, a hydraulic retention time of 1 to 9hr, an organic loading rate of 0.47 to $3.84kg\;BOD/m^3{\cdot}day$ in ASBF reactor. This equipment could obtain a stable effluent quality in spite of high variation of influent loading rate. Total biomass concentration. biofilm thickness and biofilm mass increased an exponential function according to the increasing OLR. The relationships between water content and biofilm density were in inverse proportion. The percentage of backwash water to influent flow was almost 9%. The separation efficiency of biomass was the percentage of 91 to 92 in ASBF reactor. The sludge production rates in feed solutions of simulated wastewater and domestic wastewater were 0.14~0.26 kg VSS/kg BODrem, 0.43~0.48 kg VSS/kg BODrem, respectively.

  • PDF

Permeability Reduction of Soils by Biomass Injection (미생물 균체의 주입을 통한 토양의 투수계수 감소)

  • 송영우;김건하;구동영
    • Journal of the Korean Geotechnical Society
    • /
    • v.15 no.6
    • /
    • pp.273-283
    • /
    • 1999
  • When microorganism is injected into porous medium such as soils, biomass is retained in the pore. Soil pore size and shape are varied from the initial condition as a result of biofilm formation which makes hydraulic conductivity reduced and friction rate between soil aggregates increased. In this research, hydraulic conductivity reduction was measured after microorganism are inoculated and cultured with synthetic substrate and nutrient. In addition, this research evaluated the applicability of biomass-soil mixture to the field condition as an alternative cover material in landfill by measuring hydraulic conductivity change after repetitive freeze-thaw cycles. Hydraulic conductivity of silty soil decreased by approximately 1/50 after biomass inoculation and cultivation. Biofilm attached on soil aggregates is resistant to acidic or basic condition. After repetitive freeze-thaw cycles, however, hydraulic conductivity increase implies that biomass clogging can be impaired.

  • PDF

Reduction of Hydraulic Conductivity by Soil Injection of Bacteria (Bacteria 토양주입을 통한 투수계수 감소)

  • 송영우;김건하;구동영
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.03b
    • /
    • pp.331-337
    • /
    • 2000
  • When microorganism is injected into porous medium such as soils, biomass retained in the pore. Bacteria within these microcolonies produced large amounts of exopolysaccharides and formed a plugging biofilm. Soil pore size and shape are varied from the initial condition as a result of biofilm formation, which make hydraulic conductivity reduced and friction rate between soil aggregates increased. In this research, hydraulic conductivity reduction was measured after microorganism are inoculated and cultured with synthetic substrate and nutrient. Also, pore sand of before and after biofilm formation compared with scanning electron microscopy. Hydraulic conductivity of Sand and Poorly Graded Sand was decreased approximately 1/10∼1/100 after biomass inoculation and cultivation. Biofilm attached on soil aggregates is resistant to acidic or basic condition.

  • PDF