• Title/Summary/Keyword: atomic absorption

Search Result 878, Processing Time 0.03 seconds

Determination of Metoclopramide by Flameless Atomic Absorption and Spectrophotometry (무염 원자흡광도법과 흡광광도법에 의한 제제중의 Metoclopramide의 정량)

  • 박만기;임병연;유경수;용군호
    • YAKHAK HOEJI
    • /
    • v.22 no.1
    • /
    • pp.27-32
    • /
    • 1978
  • Metoclopramide reacts with ammonium cobaltothiocyanate to form a stable ion pair which has an absorption maximum of 625mm. The reaction product was insoluble in water but soluble in most organic solvents. 1,2-Dichlorethane was the best extracting solvent among the several organic solvents tested. Metoclopramide can be determinded not only by visible light spectrophotometry but also indirectly by estimation of cobalt in the organic phase by flameless atomic absorption spectrophotometry. Linear relationship was found between absorbance and concentration in the range of 10$^{-4/}$-10$^{-3}$M by spectrophotometry and 10$^{-5}$-10$^{-4}$M by flameless atomic absorption spectrophotometry. The coefficient of variation by spectrophotometry was 0.9% and that of flameless atomic absorption was 1.8%. There was no interference with excipients, pH, temperature and reaction time. With this method, it is possible to determine accurately metoclopramide and tertiary amines in pharmaceutical preparations.

  • PDF

Magnetic and Photo-catalytic Properties of Nanocrystalline Fe Doped $TiO_2$ Powder Synthesized by Mechanical Alloying

  • Uhm, Y.R.;Woo, S.H.;Lee, M.K.;Rhee, C.K.
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09b
    • /
    • pp.955-956
    • /
    • 2006
  • Fe-doped $TiO_2$ nanopowders were prepared by mechanical alloying (MA) varying Fe contents up to 8.0 wt.%. The UV-vis absorption showed that the UV absorption for the Fe-doped powder shifted to a longer wavelength (red shift). The absorption threshold depends on the concentration of nano-size Fe dopant. As the Fe concentration increased up to 4 wt.%, the UV-vis absorption and the magnetization were increased. The benefical effect of Fe doping for photocatalysis and ferromagnetism had the critical dopant concentration of 4 wt.%. Based on the UV absorption and magnetization, the dopant level is localized to the valence band of $TiO_2$.

  • PDF

Analysis of Acetone Absorption Spectra Using Off-axis Integrated Cavity Output Spectroscopy for a Real-time Breath Test

  • Lim Lee;Yonghee Kim;Byung Jae Chun;Taek-Soo Kim;Seung-Kyu Park;Kwang-Hoon Ko;Ki-Hee Song;Hyunmin Park
    • Current Optics and Photonics
    • /
    • v.7 no.6
    • /
    • pp.761-765
    • /
    • 2023
  • We analyzed the absorption spectra of acetone in the 3.37 ㎛ mid-infrared range using the off-axis integrated cavity output spectroscopy technique to develop a real-time, in-line breath analysis device. The linear relationship between acetone concentration and absorption increase was confirmed as 0.32%/ppm, indicating that the developed device allows for a quantitative analysis of acetone concentration in exhaled breath. To further confirm the feasibility of using our device for breath analysis, we measured the acetone concentration of human breath samples at the sub-ppm level.

Semiconductor laser-based absorption spectroscopy for monitoring physical vapor deposition process (증기증착 공정 감시를 위한 반도체 레이저 흡수 분광학)

  • 정의창;송규석;차형기
    • Journal of the Korean Vacuum Society
    • /
    • v.13 no.2
    • /
    • pp.59-64
    • /
    • 2004
  • A study on the semiconductor laser-based atomic absorption spectroscopy was performed for monitoring physical vapor deposition process. Gadolinium metal was vaporized with a high evaporation rate by electron beam heating. Real-time atomic absorption spectra were measured by using tunable semiconductor laser beam at 770-794 nm (center wavelength of 780 nm) and its second harmonic at 388-396 nm. Atomic densities of metal vapor can be calculated from the absorption spectra measured. We plot the atomic densities as a function of the electron beam power and compare with the evaporation rates measured by quartz crystal monitor. We demonstrate that the semiconductor laser-based spectroscopic system developed in this study can be applied to monitor the physical vapor deposition process for other metals such as titanium.

Effects of Algal Polysaccharides on the Intestinal Absorption of Cadmium in Albino Rat (카드뮴의 장내흡수(腸內吸收)에 미치는 해조다당류(海藻多糖類)의 영향)

  • Kim, Young-Bae;Kang, Myung-Hee;Lee, Su-Rae
    • Journal of Nutrition and Health
    • /
    • v.10 no.1
    • /
    • pp.18-21
    • /
    • 1977
  • Effects of alginate and tangle on the suppression of intestinal absorption of heavy metals were tested by albino rats. The absorption of cadmium was suppressed by adding 5% or 10% alginate to the diets contaminated with 5 ppm cadmium, but not by 1% a1ginate or 10% tangle (p<0.05).

  • PDF

A Suppressive Effect of Alginate on the Intestinal Absorption of Cadmium in vitro (카드뮴의 장내흡수(腸內吸收)에 미치는 알진산(酸)의 억제(抑制)효과)

  • Yang, Jae-Seung;Hahn, Sung-Hee;Lee, Su-Rae
    • Journal of Nutrition and Health
    • /
    • v.11 no.3
    • /
    • pp.9-12
    • /
    • 1978
  • An effect of alginate and seaweeds on the intestinal absorption of cadmium was tested in vitro. The absorption of cadmium was remarkably suppressed by alginate though the effect was not selective toward cadmium or calcium. The suppressive effect was also observed with tangle and laver, differing in some aspects from alginate only.

  • PDF

Atomic Absorption Spectrophotometric Analysis of Chromium, Nickel and Manganese in Stainless Steel (原子吸光分析에 의한 鋼鐵속에 있는 Cr, Mn 및 Ni 의 定量)

  • Hwang, Jae-Young;Tagliamonti, Josep J.;Parsons, Frank B.
    • Journal of the Korean Chemical Society
    • /
    • v.10 no.3
    • /
    • pp.133-135
    • /
    • 1966
  • Rapid methods for determining chromium, nickel, and manganese in stainless steel by atomic absorption spectrophotometer are described. Use of suitable standards eliminates the need to separate each element prior to analysis. Comparison with the conventional wet chemical analysis shows that atomic absorption spectrophotometer is a reliable analytical tool in these applications.

  • PDF

Characterization and Studies of Compromised Experimental Conditions for the Simultaneous Multielemental Analysis by Flame Atomic Absorption Spectrometry (원자흡수법을 이용한 다원소 동시 분석 실험 조건에 관한 기초 특성 연구)

  • 최성규;이현주;박양순;김효진
    • YAKHAK HOEJI
    • /
    • v.39 no.2
    • /
    • pp.148-152
    • /
    • 1995
  • For comparison between the compromised experimental condition and the best conditions for each element by flame atomic absorption spectrometer, the absorbances were measured with changing the burner height and HCL current. The optimum absorbance for simultaneous analysis of 6 elements was observed at 1 mA of HCL current and at 4 mm of burner height except Cr and Co. The stability of flame atomic absorption spectrometer on each element was found to be better than 5%. To investigated the accuracy of this instrument, POSCO RM-07 as a real sample was analysed at these compromised experimental conditions and found to be better than 0.04%.

  • PDF

Dependence Evaluation of the Self-Absorption Correction Factor for p-type High Purity Germanium Detector Characteristics (p-type HPGe 검출기 특성에 따른 밀도 보정인자 의존도 평가)

  • Jang, Mee;Ji, Young-Yong;Kim, Chang-Jong;Lee, Wanno;Kang, Mun Ja
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.13 no.4
    • /
    • pp.295-300
    • /
    • 2015
  • The precise determination of the activity for each radionuclide in environmental samples requires the self-absorption correction factor. In this research, we derived the self-absorption correction factor for three p-type high purity germanium detectors using the Monte Carlo code MCNPX. These detectors have different characteristics such as crystal diameter, height and size of the core. We compared the calculated full-energy peak efficiency with the experimental value using a standard sample with $1g/m^3$ density and verified the modeling. We simulated the dependency of the full-energy peak efficiency on the 0.3, 0.6, 0.9, 1.0, 1.2 and $1.5g/m^3$ samples and obtained the corresponding self-absorption correction factor. The self-absorption correction factors calculated for the three detectors differ by less than 1% over most of the energy range and sample densities considered. This indicates that the self-absorption correction factors are independent of the crystal characteristics of HPGe detector.

Determination of Pipethanate$\cdot$HCl by Spectrophotometry and Atomic Absorption Spectrophotometry (흡광광도법 및 원자흡광광도법에 의한 Pipethanate$\cdot$HCl의 정량)

  • 이왕규;박만기;김박광;손채연
    • YAKHAK HOEJI
    • /
    • v.27 no.4
    • /
    • pp.303-307
    • /
    • 1983
  • Pipethanate*HCl reacts with ammonium cobaltothiocyanate to form a stable ion pair which has an absorption maximum at 626nm. The reaction product was insoluble in water but freely soluble in most organic solvents. 1, 2-Dichloroethane was the best extracting solvent among the several organic solvents. Pipethanate*HCl can be determined not only by the spectrophotometry but also inderectly by estimation of cobalt in the organic phase by atomic absorption spectrophotometry. Linear relationship was found between absorbance and concentration in the range of $1.0{\times}10^{-3}~4.0{\times}10^{-3}M$ by spectrophotometry and $1.5{\times}10^{-4}~4.0{\times}10^{-4}M$ by atomic absorption spectrophotometry. With this method it was possible to determine pipethanate$\cdot$HCl in the pharmaceutical preparations.

  • PDF