• 제목/요약/키워드: atmospheric instability

검색결과 94건 처리시간 0.031초

한반도 중서부 국지성 집중호우와 관련된 열역학적 특성 (Thermodynamic Characteristics Associated with Localized Torrential Rainfall Events in the Middle West Region of Korean Peninsula)

  • 정승필;권태영;한상옥
    • 대기
    • /
    • 제24권4호
    • /
    • pp.457-470
    • /
    • 2014
  • Thermodynamic conditions related with localized torrential rainfall in the middle west region of Korean peninsula are examined using radar rain rate and radiosonde observational data. Localized torrential rainfall events in this study are defined by three criteria base on 1) any one of Automated Synoptic Observing System (ASOS) hourly rainfall exceeds $30mmhr^{-1}$ around Osan, 2) the rain (> $1mmhr^{-1}$) area estimated from radar reflectivity is less than $20,000km^2$, and 3) the rain (> $10mmhr^{-1}$) cell is detected clearly and duration is short than 24 hr. As a result, 13 cases were selected during the summer season of 10 years (2004-13). It was found that the duration, the maximum rain area, and the maximum volumetric rain rate of convective cells (> $30mmhr^{-1}$) are less than 9hr, smaller than $1,000km^2$, and $15,000{\sim}60,000m^3s^{-1}$ in these cases. And a majority of cases shows the following thermodynamic characteristics: 1) Convective Available Potential Energy (CAPE) > $800Jkg^{-1}$, 2) Convective Inhibition (CIN) < $40Jkg^{-1}$, 3) Total Precipitable Water (TPW) ${\approx}$ 55 mm, and 4) Storm Relative Helicity (SRH) < $120m^2s^{-2}$. These cases mostly occurred in the afternoon. These thermodynamic conditions indicated that these cases were caused by strong atmospheric instability, lifting to overcome CIN, and sufficient moisture. The localized torrential rainfall occurred with deep moisture convection result from the instability caused by convective heating.

A Case Study of Tsukuba Tornado in Japan on 6 May 2012

  • Choo, Seonhee;Min, Ki-Hong;Kim, Kyung-Eak;Lee, Gyuwon
    • 한국지구과학회지
    • /
    • 제39권5호
    • /
    • pp.403-418
    • /
    • 2018
  • This study conducted synoptic and mesoscale analyses to understand the cause of Japan Tsukuba tornado development, which occurred at 0340 UTC 6 May 2012. Prior to the tornado occurrence, there was a circular jet stream over Japan, and the surface was moist due to overnight precipitation. The circular jet stream brought cold and dry air to the upper-level atmosphere which let strong solar radiation heat the ground with clearing of sky cover. A tornadic supercell developed in the area of potentially unstable atmosphere. Sounding data at Tateno showed a capping inversion at 900 hPa at 0000 UTC 6 May. Strong insolation in early morning hours and removal of the inversion instigated vigorous updraft with rotation due to vertical shear in the upper-level atmosphere. This caused multiple tornadoes to occur from 0220 to 0340 UTC 6 May 2012. When comparing Tateno's climatological temperature and dew-point temperature profile on the day of event, the mid-level atmosphere was moister than typical sounding in the region. This study showed that tornado development in Tsukuba was caused by a combination of (a) topography and potential vorticity anomaly, which increased vorticity over the Kanto Plain; (b) vertical shear, which produced horizontal vortex line; and c) thermal instability, which triggered supercell and tilted the vortex line in the vertical.

희박 예혼합 덤프 연소기에서 OH 자발광을 이용한 열 방출에 관한 실험적 연구 (Experimental Study on Heat Release in a Lean Premixed Dump Combustor using OH Chemiluminescence Images)

  • 문건필;이종호;전충환;장영준
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1146-1151
    • /
    • 2004
  • Measurements of OH chemiluminescence in an atmospheric pressure, laboratory-scale dump combustor at equivalence ratios ranging from 0.63 to 0.89 were reported. The signal from the first electronically excited state of OH to ground state was detected through a band-pass filter with an ICCD. The objectives of this study are two: One is to see the effects of equivalence ratio on global heat release rate and local Rayleigh index distribution. To get the local Rayleigh index distribution, the line-of-sight images were inverted by tomographic method, such as Abel de-convolution. Another aim is to investigate the validity of using OH chemiluminescence acquired with an ICCD as a qualitative measure of local heat release. For constant inlet velocity and temperature, the overall intensities of OH emission acquired at different equivalence ratio showed periodic and higher value at high equivalence ratio. OH intensity averaged over one period of pressure increased exponentially with equivalence ratio. Local Rayleigh index distribution clearly showed the region of amplifying or damping the combustion instability as equivalence ratio increased. It could provide an information/insights on active control such as secondary fuel injection. Finally, local heat release rate derived from reconstructed OH images were presented for typical locations.

  • PDF

헬름홀쯔 공명기의 기하학적 형상과 가진 음압에 따른 감쇠 특성 (Damping Characteristic of Helmholtz Resonator according to Its Geometry and Sound Pressure Level)

  • 송재강;김기우;채병찬;고영성;김선진
    • 한국항공우주학회지
    • /
    • 제38권10호
    • /
    • pp.966-972
    • /
    • 2010
  • 본 연구에서는 연소불안정 현상을 제어하는 수동적 기구의 하나인 음향공을 적용하여, 음향공의 설계 변수(오리피스 길이와 지름)와 가진 음압에 따른 감쇠 효과를 선형음향해석과 상온 음향시험을 통하여 연구하였다. 오리피스의 길이가 짧고, 지름이 클수록 감쇠효과가 증가하는 것을 확인하였으며 실험과 선형 음향 해석 결과가 서로 동일한 경향을 보이는 것을 확인하였다. 또한, 가진 음압의 크기가 110 dB 이상에서 감쇠 능력이 비선형적으로 감소하는 것을 확인하였으며, 음향공 오리피스의 단면적이 증가할수록 감소량이 감소하는 것으로부터 비선형 구간에서는 오리피스 단면적을 증가시키는 것이 유리함을 확인하였다.

가스터빈 연소기에서 $CO_2^*$ 배경 강도가 $OH^*$$CH^*$ 화학 발광 강도에 미치는 영향 ($CO_2^*$ Background Effect on $OH^*$ and $CH^*$ Chemiluminescence Intensities in a Gas Turbine Combustor)

  • 김대식;이종근
    • 한국연소학회지
    • /
    • 제15권4호
    • /
    • pp.37-42
    • /
    • 2010
  • The measurement of heat release rate is of great importance in the study of thermo-acoustic instability occurring in lean premixed combustion and the chemiluminescence emission has been used as an indicator of heat release in combustion instability studies primarily for its relative simplicity. This paper presents results of experimental study of flame chemiluminescence from an atmospheric, swirl-stabilized, turbulent lean premixed flame with a main emphasis on the effect of $CO_2^*$ background level in the $CH^*$ and $OH^*$ band. The test results show that the effect of $CO_2^*$ level in the $CH^*$ band is greater than that in the $OH^*$ band. Also, the background to peak ratio for both $CH^*$ and $OH^*$ bands can be expressed as a function of equivalence ratio, almost regardless of a change in the inlet velocity.

덤프형 가스터빈 연소기에서의 화염 불안정성의 사전 감지 인자 (Pre-detection Parameter of the Combustion Instabilities in the Gas Turbine Combustor)

  • 이병준
    • 대한기계학회논문집B
    • /
    • 제26권5호
    • /
    • pp.750-756
    • /
    • 2002
  • The effect of equivalence ratio and velocity on the stability of flame in dump combustor was studied in an atmospheric pressure, laboratory scathe dump combustor operating natural gas. Traditionally, peak-to-peak pressure, fluctuation of the heat release rate and Rayleigh index were used to find and control the combustion instability. Cross correlation coefficients, Ci,j which is defined as the normalized value of the integration of the product of two of the mixer pressure, dump plane pressure and heat release rate, are introduced to see whether the flame is stable or not. Ci,j shows more sensitive to combustion status than Rayleigh index in steadily burning flame. Also, the result indicates that the amplitude of Ci,j between heat release and mixer pressure goes up before the flame at the rich de-stabilizing equivalence ratio near $\psi$=0.85. t means Ci:j at this case has a potential to detect the de-stablizing moment in prior to becoming unstable in dump combustor.

뇌전을 동반한 영동지역 대설 사례연구 (A Case Study of Heavy Snowfall with Thunder and Lightning in Youngdong Area)

  • 김해민;정승필;인소라;최병철
    • 대기
    • /
    • 제28권2호
    • /
    • pp.187-200
    • /
    • 2018
  • The heavy snowfall phenomenon with thunder and lightning occurred in Yeongdong coastal region on 20 January 2017. Amount of snow on that day was a maximum of 47 cm and was concentrated in a short time (2 hours) at the Yeongdong coastal area. The mechanism of thundersnow was investigated to describe in detail using observational data and numerical simulation (Weather Research and Forecast, WRF) applied lightning option. The results show that a convective cloud occurred at the Yeongdong coastal area. The east wind flow was generated and the pressure gradient force was maximized by the rapidly developed cyclone. The cold and dry air in the upper atmosphere has descended (so called tropopause folding) atmospheric lower layer at precipitation peak time (1200 LST). In addition, latent heat in the lower atmosphere layer and warm sea surface temperature caused thermal instability. The convective cloud caused by the strong thermal instability was developed up to 6 km at that time. And the backdoor cold front was determined by the change characteristics of meteorological elements and shear line in the east sea. Instability indexes such as Total totals Index (TT) and Lightning Potential Index (LPI) are also confirmed as one of good predictability indicates for the explosive precipitation of convective rainfall.

연소불안정 저감을 위한 음향학적 감쇠기능성 스월 인젝터 (Acoustic Damping Swirl Injector for Reduction of Combustion Instability)

  • 김현성;김병선;김동준;윤영빈
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2007년도 제28회 춘계학술대회논문집
    • /
    • pp.7-12
    • /
    • 2007
  • 액체로켓엔진에서 고주파 연소불안정을 제어하기 위하여 다단 접선 유입구를 갖는 스월 인젝터를 분석하였다. 음향흡수자로서 인젝터의 효과를 분석하기 위하여 인젝터는 1/4 파장 공명기로 해석하였고, 상온에서 감쇠 효과의 적합성을 검증하였다. 이러한 인젝터는 모델 챔버의 고유주파수에 동조 시킬 수 있는 고유주파수를 갖게 된다. 각각의 모드에 동조된 인젝터를 배(anti-node point)에 장착하여야만, 타겟모드의 진폭을 감소시킬 수 있었고, 큰 지름의 인젝터를 사용하였을 때 보다 큰 진폭의 감쇠를 동반하면서 모드 분리 현상이 나타났다. 이러한 실험 결과로부터 타겟모드에 동조된 인젝터를 적당한 볼륨으로 배(anti-node point)에 장착한다면, 모드 진폭이 감쇠하게 되고, 완전한 배(anti-node point)에서는 모드분리현상이 발생됨을 확인하였다.

  • PDF

2012년 특별관측 자료를 이용한 동해안 겨울철 강수 특성 분석 (Characteristics of Precipitation over the East Coast of Korea Based on the Special Observation during the Winter Season of 2012)

  • 정승필;임윤규;김기훈;한상옥;권태영
    • 한국지구과학회지
    • /
    • 제35권1호
    • /
    • pp.41-53
    • /
    • 2014
  • 겨울철 동해안 강수 현상에 대한 규명을 위하여 라디오존데를 활용한 특별관측을 2012년 1월 5일부터 2월 29일까지 실시하였고, 이 연구는 대기의 불안정을 나타내는 다양한 변수를 활용하여 강수 사례의 분석을 수행하였다. 그 결과, 강수가 발생할 때 지표면(1000 hPa)에서 중층(약 750 hPa)까지의 상당온위가 증가하는 것을 볼 수 있었고, 이러한 대기층(1000~750 hPa)은 불안정을 일으키기에 충분한 수준의 수증기를 함유하고 있었다. 대류가용잠재에너지의 시간적인 변화를 살펴본 결과 강수가 발생하였을 때 증가하는 것을 볼 수 있었고, 연직바람쉬어의 경우에서도 대류가용잠재에너지와 마찬가지로 강수 기간 동안 상승하여 일정수준 이상의 값을 유지하는 것을 확인할 수 있었다. 강수에 따른 대기 구조의 상세한 분석을 위하여 지상 원격 탐사 자료와 지상 관측 자료를 활용하여 분석을 수행하였다. 또한 가강수량과 바람벡터를 이용하여 가강수량플럭스를 계산하였다. 가강수량플럭스와 강수량은 북동풍 계열의 바람이 발생하였을 때 높은 관계성을 보였다. 그 결과 동해안영역에서 발생하는 강수 현상에서는 풍계와 같은 역학적인 작용의 이해가 중요한 것으로 판단되었다.

2018년 8월 6일 발생한 영동지역 집중호우 사례에 대한 특성 연구 (Characteristics of a Heavy Rainfall Event in Yeongdong Region on 6 August, 2018)

  • 안보영;심재관;김규랑;김승범
    • 한국지구과학회지
    • /
    • 제41권3호
    • /
    • pp.222-237
    • /
    • 2020
  • 2018년 8월 6일 영동지역에서 강한 대류 세포에 의해 천둥과 번개를 동반한 집중호우(강릉: 93 mm hr-1)가 발생했다. 집중호우 사례의 특성을 조사하기 위하여 COMS 위성의 구름 산출물 자료, 상하층 종관 일기도, ECMWF 재분석 자료, 라디오존데 자료를 이용하였다. 분석결과, 상층의 차고 건조한 공기가 동해상(영동지역)으로 유입되면서 상대적으로 중·하층에 따뜻하고 습한 공기와 만나 대기의 불안정을 만들고 대류운이 급격하게 발달하면서 단시간에 많은 강수가 내렸다. COMS 위성의 구름 운정 온도가 약 -65℃ 이상, 구름 광학 두께는 약 20-25 이상의 높은 값을 보일 때 강수량은 10 mm hr-1 이상으로 나타났다. 따라서 강수량은 구름 내의 수분 양 그리고 구름의 키와 밀접한 관련성을 가지는 것을 확인할 수 있었다. 라디오존데 자료의 연직 분석에서는 상하층 간의 연직 바람 쉬어가 크게 나타났다. 약 700 hPa 고도에서는 역전층이 나타나면서 상층과 하층간의 상당온위의 차이를 유발하여 대기불안정을 더욱 강화시켰으며 구름층은 고도 약 13 km 이상으로 발달하는 것을 확인할 수 있었다. 이러한 결과는 ECMWF 재분석 자료의 연직 분석에서도 확인할 수 있었다.