• Title/Summary/Keyword: asymmetry parameter

Search Result 61, Processing Time 0.023 seconds

Reliability and Validity of the Measurement of Pelvic Movement in Low Back Pain Patients using Cushion Sensor in Sitting Position (앉은 자세에서 방석센서를 이용한 요통환자 골반가동성 측정의 신뢰도와 타당도)

  • Jung, Seung-Hwa;Park, Dae-Sung
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.15 no.2
    • /
    • pp.83-91
    • /
    • 2020
  • PURPOSE: Postural and structural asymmetry due to muscle imbalances around the lower back and pelvis are the causes of back pain. Muscle imbalances in patients with chronic low back pain affect the pelvic tilt and movement, and it is necessary to assess the pelvic movement ability using the appropriate tools to determine the mediating effects of lower back pain. This paper reports the reliability and validity of the Sensbalance Therapy Cushion (STC) for pelvic movement and proprioception. METHODS: In this study, the Wii balance board (WBB) was used as a golden standard for pelvic movement measurements. FABQ, KODI, Myovision, and Pelvic movement were measured in 50 patients with chronic low back pain. The correlation between the lower-back muscle activity and pelvic movement was checked. The pelvic movement parameter was measured twice to determine the intra-rater reliability. RESULTS: The STC showed high test-retest reliability in the pelvic tilt measurements (ICC = .672 - .809). The test-retest reliability of proprioception measurements (ICC = .588 - .859) and reaction time measurements (ICC = .542 - .836) were also high. The relationship between the WBB and STC showed a significant positive correlation with the pelvic tilt test (p < .01). The posterior pelvic tilt and lower-back muscle activity showed a significant negative correlation (p < .01). The pelvic left tilt and lower-back muscle activity showed a significant negative correlation (p < .05). CONCLUSION: The results revealed the high reliability and validity of the STC. Therefore, the STC can be used as an objective measuring device for evaluating pelvic tilt, proprioception, and reaction time in low back pain patients.

Computational Study on the Hemodynamics of the Bypass Shunt Directly Connecting the left Ventricle to a Coronary Artery

  • Shim Eun Bo;Lee Byung Jun;Ko Hyung Jong
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.1158-1168
    • /
    • 2005
  • A shunt from the left ventricle to the left anterior descending artery is being developed for coronary artery occlusive disease, in which the shunt or conduit connects the the left ventricle (LV) with the diseased artery directly at a point distal to the obstruction. To aid in assessing and optimizing its benefit, a computational model of the cardiovascular system was developed and used to explore various design conditions. Computational fluid dynamic analysis for the shunt hemodynamics was also done using a commercial finite element package. Simulation results indicate that in complete left anterior descending artery (LAD) occlusion, flow can be returned to approximately 65% of normal, if the conduit resistance is equal for forward and reverse flow. The net coronary flow can increase to 80% when the backflow resistance is infinite. The increases in flow rate produced by asymmetric flow resistance are enhanced considerably for a partial LAD obstruction, since the primary effect of resistance asymmetry is to prevent leakage back into the ventricle during diastole. Increased arterial compliance has little effect on net flow with a symmetric shunt, but considerably augments it when the resistance is asymmetric. The computational results suggest that an LV-LAD conduit will be beneficial when the resistance due to artery stenosis exceeds 27 PRU, if the resistance is symmetric. Fluid dynamic simulations for the shunt flow show that a recirculating region generated near the junction of the coronary artery with the bypass shunt. The secondary flow is induced at the cutting plane perpendicular to the axis direction and it is in the attenuated of coronary artery.

Analytical Solutions for Predicting Movement Rate of Submerged Mound (수중둔덕의 이동율 예측을 위한 해석해)

    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.10 no.4
    • /
    • pp.165-173
    • /
    • 1998
  • Analytical solutions to predict the movement rate of submerged mound are derived using the convection coefficient and the joint distribution function of wave heights and periods. Assuming that the sediment is moved onshore due to the velocity asymmetry of Stokes' second order nonlinear wave theory, the micro-scale bedload transport equation is applied to the sediment conservation. The nonlinear convection-diffusion equation can then be obtained which governs the migration of submerged mound. The movement rate decreases exponentially with increasing the water depth, but the movement rate tends to increase as the spectral width parameter, $ u$ increases. In comparison of the analytical solution with the measured data, it is found that the analytical solution overestimates the movement rate. However, the agreement between the analytical solution and the measured data is encouraging since this over-estimation may be due to the inaccuracy of input data and the limitation of sediment transport model. In particular, the movement rates with respect to the water depth predicted by the analytical solution are in very good agreement with the estimated result using the discritization technique with the hindcast wave data.

  • PDF

Perpendicular Spin-transfer Torque in Asymmetric Magnetic Tunnel Junctions: Material Parameter Dependence (비대칭 자기터널접합에서의 수직 스핀 전달 토크: 물질 변수에 대한 의존성)

  • Han, Jae-Ho;Lee, Hyun-Woo
    • Journal of the Korean Magnetics Society
    • /
    • v.21 no.2
    • /
    • pp.52-55
    • /
    • 2011
  • Spin-transfer torque is a useful tool to control the magnetic state in nanostructures. In magnetic tunnel junctions, the spin-transfer torque has two components, the in-plane spin torque and the perpendicular spin torque. While properties of the in-plane spin-transfer torque are relatively well understood, properties of the perpendicular spin-transfer torque still remain controversial. A recent experiment demonstrated that in asymmetric magnetic tunnel junctions, the bias voltage dependence of the perpendicular spin-transfer torque contains both linear and quadratic terms in the bias. However it still remains unexplored how the bias voltage dependence changes as a function of material parameters. In this paper, we systematically investigate the perpendicular spin-transfer torque in asymmetric magnetic tunnel junction by varying spin splitting energy, work function difference, and Fermi energy of the ferromagnetic metal leads.

Far-ultraviolet Observations of the Taurus-Perseus-Auriga Complex

  • Lim, Tae-Ho;Min, Kyoung-Wook;Seon, Kwang-Il
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.98.2-98.2
    • /
    • 2012
  • We firstly present the unified Far-UV continuum map of the Taurus-Auriga-Perseus (TPA) complex, one of the largest local associations of dark cloud located in (l, b)=([154,180], [-28, -2]), by merging both FIMS and GALEX. The FUV continuum map shows that dust extinction correlate well with the FUV around the complex. It shows strong absorption in FUV toward the dense Taurus cloud while it does not in California cloud. It turned out that it is related to the relative location of each cloud and Perseus OB2 association. We also present some results of dust scattering simulation based on Monte Carlo Radiative Transfer technique (MCRT). Through this dust scattering simulation, we have derived the scattering parameter for this region, albedo(a)=$0.42^{+0.05}{_{-0.05}}$, asymmetry factor(g)=$0.47^{+0.11}{_{-0.27}}$. The optical parameters we obtained seem reasonable compared to the theoretical model values ~0.40 and ~0.65 for the albedo and the phase function though the phase function is rather small. Using the result of simulation, we figured out the geometries of each cloud in the complex region, especially their distances and thicknesses. Our predictions from the results are in good agreement with the previous studies related to the TPA complex. For example, the Taurus cloud is within ~200pc from the Sun and the Perseus seems to be multi-layered, at least two. The California cloud is more distant than the other cloud on average at ~350 pc and Auriga cloud seems to be between the Taurus cloud and the eastern end of the California cloud. We figured out that across the TPA complex region, there might be some correlation between the LSR velocity and the distance to each cloud in the complex.

  • PDF

HI gas kinematics of paired galaxies in the cluster environment from ASKAP pilot observations

  • Kim, Shin-Jeong;Oh, Se-Heon;Kim, Minsu;Park, Hye-Jin;Kim, Shinna
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.46 no.2
    • /
    • pp.70.1-70.1
    • /
    • 2021
  • We examine the HI gas kinematics and distributions of galaxy pairs in group or cluster environments from high-resolution Australian Square Kilometer Array Pathfinder (ASKAP) WALLABY pilot observations. We use 32 well-resolved close pair galaxies from the Hydra, Norma, and NGC 4636, two clusters and a group of which are identified by their spectroscopy information and additional visual inspection. We perform profile decomposition of HI velocity profiles of the galaxies using a new tool, BAYGAUD which allows us to separate a line-of-sight velocity profile into an optimal number of Gaussian components based on Bayesian MCMC techniques. Then, we construct super profiles via stacking of individual HI velocity profiles after aligning their central velocities. We fit a model which consists of double Gaussian components to the super profiles, and classify them as kinematically cold and warm HI gas components with respect to their velocity dispersions, narrower or wider 𝜎, respectively. The kinematically cold HI gas reservoir (M_cold/M_HI) of the paired galaxies is found to be relatively higher than that of unpaired control samples in the clusters and the group, showing a positive correlation with the HI mass in general. Additionally, we quantify the gravitational instability of the HI gas disk of the sample galaxies using their Toomre Q parameters and HI morphological disturbances. While no significant difference is found for the Q parameter values between the paired and unpaired galaxies, the paired galaxies tend to have larger HI asymmetry values which are derived using their moment0 map compared to those of the non-paired control sample galaxies in the distribution.

  • PDF

Effects of Ethanol on the Fluidity of Plasma Membrane Vesicles Isolated from Cultured Mouse Myeloma Cell Line Sp2/0-Ag14 (Ethanol이 배양된 Mouse Myeloma Cell Line Sp2/0-Ag14로부터 분리한 형질막의 유동성에 미치는 영향)

  • Yun, Il;Chung, In-Kyo;Park, Yeong-Min;Kim, Jin-Bom;Yu, Seoung-Ho;Kang, Jung-Sook
    • The Korean Journal of Pharmacology
    • /
    • v.29 no.1
    • /
    • pp.149-156
    • /
    • 1993
  • Intramolecular excimerization of 1,3-di(1-pyrenyl)propane (Py-3-Py) and fluorescence polarization of 1,6-diphenyl-1,3,5-hexatriene (DPH) were used to examine the effects of ethanol on the rate and range of lateral diffusion of bulk bilayer structures of plasma membrane vesicles isolated from cultured mouse myeloma cell line Sp2/0-Ag14 (Sp2/0-PMV). In a concentration-dependent manner, ethanol increased the excimer to monomer fluorescence intensity ratio (I'/I) of Py-3-Py in the Sp2/0-PMV and decreased the anisotropy (r), limiting anisotropy $(r_{\infty})$, and order parameter (S) of DPH in the Sp2/0-PMV. This indicates that ethanol increased both the lateral and rotational diffusion of the probes in the Sp2/0-PMV. Selective quenching of DPH by trinitrophenyl groups was utilized to examine the transbilayer asymmetric rotational diffusion of the Sp2/0-PMV. The anisotropy (r), limiting anisotropy $(r_{\infty})$, and order parameter (S) of DPH in the inner monolayer were 0.022, 0.029, and 0.063, respectively, greater than calculated for the outer monolayer of the Sp2/0-PMV. Selective quenching of DPH by trinitrophenyl groups was also utilized to examine the transbilayer asymmetric effects of ethanol on the range of rotational diffusion of the Sp2/0-PMV. Ethanol had a greater fluidizing effect on the outer monolayer as compared to the inner monolayer of the Sp2/0-PMV. It has been proven that ethanol exhibits a selective rather than nonselective fluidizing effect within transbilayer domains of the Sp2/0-PMV.

  • PDF

Functional MRI ofThe Supplementary Motor Area in Hand Motor Task: Comparison Study with The Primary Motor Area (수지운동자극을 사용한 부운동중추의 기능적 MR연구: 일차운동중추와의 비교)

  • 이호규;김진서;최충곤;임태환
    • Investigative Magnetic Resonance Imaging
    • /
    • v.1 no.1
    • /
    • pp.103-107
    • /
    • 1997
  • Purpose: To investigate the localization and functional lateralization of the supplementary motor area (SMA) in motor activation tests in comparison to that of the primary motor area. Materials and Methods: Seven healthy volunteers obtained echoplanar imaging blood oxygen level dependent technique. This study was carried on 1.5T Siemens Magnetom Vision system with the standard head coil. Parameters of EPI were followed as; TR/TE : 1.0/66.0msec, flip angle: $90^{\circ}$, field of view: $22cm{\times}22cm,{\;}matrix:{\;}128{\times}128$, slice number/slice thickness/gap: 1O/4mm/0.8mm with fat suppression technique. Motor task as finger opposition in each hand consisted of 3 sets of alternative rest and activation periods. Postprocessing were done on Stimulate 5.0 by using cross-correlation statistics. To compare the functional lateralization of the SMA in the right and left hand tests, each examination was evaluated for the percent change of signal intensity and the number of activated voxels both in the SMA and in the pri¬mary motor area. Hemispheric asymmetry was defined as difference of summation of the activted voxels between each hemisphere. Results: Percent change of signal intensity in the SMA (2.49 -3.06%) is lower than that of primary motor area(4.4 -7.23%). Percent change of signal intensity including activated voxels were observed almost equally in the right and left SMA. As for summation of activated voxels, primary motor area had significant difference between each hemisphere but not did the SMA. Conclusion: Preferred contralateral dominant hemisphere and hemispheric asymmetry were detected in the primary motor area but not in the SMA.

  • PDF

Structure and herbicidal activity relationships of the 2,3-dihydro-2,3,4,6,7-penta-methylbenzofuran-5-yl substituents in 5-benzofuryl-2-[1-(alkoxyimine) alkyl]-3-hydroxycyclohex-2-en-1-ones (5-Benzofuryl-2-[1-(alkoxyimine) alkyl]-3-hydroxycyclohex-2-en-1-one 유도체의 구조-활성관계 2,3-dihydro-2,3,4,6,7-pentamethylben-zofuran-5-yl 치환체들의 구조와 제초 활성과의 관계)

  • Sung, Nack-Do;Song, Jong-Hwan;Jeon, Dong-Ju
    • The Korean Journal of Pesticide Science
    • /
    • v.5 no.3
    • /
    • pp.12-17
    • /
    • 2001
  • A new 2,3-dihydro-2,3,4,6,7-pentamethylbenzofuran-5-yl substituents in 5-benzofuryl-2-[1-(alkoxyimine) alkyl]-3-hydroxycyclohex-2-en-1-ones were found to have herbicidal activity against rice plant (Oryza sativa L.) and barnyard grass (Echinochloa crus-galli) under submerged conditions. The structure activity. relationships (SARs) on the herbicidal activity of $R_1\;and\;R_2$ on the azomethine bond of 2,3-dihydro-2,3,4,6,7-pentamethylbenzofuran-5-yl subsituents were analysized. The conditions of the selective herbicide activity between rice plant (seed) and barnyard grass from the basis on the analysized SARs are assumed that the $R_2$ group of ethyl substituent ($R_1$ ) should have optimal asymmetry parameter, $(L/B_1)_{opt.}=3.96{\AA}$. And also, the $R_2$ groups consist of $C_1{\sim}C_3$ and unsaturated group such as 3-chloro-2-propenyl group was contribution to the herbicide activity.

  • PDF

A Study on Three-phase Imbalance of a Power Transmission Line due to Installation of a Passive Loop Conductor (수동루프에 의한 송전선로 상불평형 발생에 관한 연구)

  • 김종형;신명철;최상열
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.6
    • /
    • pp.31-38
    • /
    • 2003
  • Among mitigation techniques for electric and magnetic field (EMF) from an overhead transmission line a passive loop is a way that can be cheap and easily installed on the existing towers and have a satisfactory effect as well. However current induced in the passive loop causes transmission power loss and the phase imbalance increases since geometrical asymmetry of the transmission lines becomes larger. So in order to evaluate the power loss and the phase imbalance due to a passive loop, this paper represent a 345[kV] 1-circuit flat type transmission line as asymmetrical 3-phase distributed parameter line model where the effect of a passive loop is embedded in the line parameters, and then formulates differential equations. By solving these equations voltages and currents of each phase at receiving end become known. We find out that power losses occur differently at each phase and positive sequence component decreases at receiving end while negative sequence component increase. In general phase imbalance due to a passive loop is slight, but it increases in proportional to the induced current and length of section where the passive loop is installed. Thus the phase imbalance should be included in terms of cost for introducing a passive loop.