• Title/Summary/Keyword: asymmetrical power

Search Result 175, Processing Time 0.026 seconds

Low Cost Single-Sourced Asymmetrical Cascaded H-Bridge Multilevel Inverter (저비용 단일전원 비대칭 Cascaded H-Bridge 멀티레벨 인버터)

  • Manoharan, Mohana Sundar;Ahmed, Ashraf;Lee, Chun-Gu;Park, Jong-Hu
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.323-324
    • /
    • 2015
  • Recently, asymmetrical cascaded H-bridge multilevel inverter started to be highlighted as an alternative for the symmetrical cascaded H-bridge. The topology has a small number of part count compared to the symmetrical with higher number of levels. However, it has a drawback of the modulation index limitation which is relatively higher than its symmetrical counterpart, which causes a necessity of an extra voltage pre-regulator. In this paper, the single-sourced pre-regulator is unified with an inner single switch DC/DC converter isolated by coupled inductor. It leads to cost and size reduction. The proposed topology is verified using simulation results.

  • PDF

Taking stock of Australia's asymmetrical relations with China: interdependence, tensions, and new dimensions

  • Kizekova, Alica
    • Journal of Contemporary Eastern Asia
    • /
    • v.20 no.2
    • /
    • pp.197-209
    • /
    • 2021
  • This article deals with the asymmetrical relations between Australia and China and explores their interdependence, tensions, and societal outlooks. Both countries are dependent on one another for trade to different degrees but attempt to diversify their supply chains. While there is no united position on China in Australia, there has been a bipartisan support for the counter-interference legislation there. The newly established security pact of the United States (US), the United Kingdom (UK) and Australia - 'AUKUS' - has brought a new dimension into these tensions and will most likely lead to an arms race. The author explores how a so-called middle power such as Australia balances the related economic and strategic interests and priorities. Although Australia has been vulnerable in its asymmetric relationship with China, it has shown that it is not a passive and helpless actor when facing an economic coercion. The interdependence has become a moderating factor in this strategic stand-off. Additionally, Australia demonstrates its tendency to reinforce its traditional reliance on its previous more powerful allies, the UK and the US.

Step-up and Step-down Asymmetrical 24-Pulse Autotransformer Rectifier

  • Zhang, Lu;Ge, Hong-juan;Jiang, Fan;Yang, Guang;Lin, Yi
    • Journal of Power Electronics
    • /
    • v.18 no.5
    • /
    • pp.1536-1544
    • /
    • 2018
  • The existing 24-pulse autotransformer rectifier unit (ATRU) needs interphase reactors for parallel work of the rectifier bridges, and its output voltage cannot be regulated. Aiming at these problems, a step-up and step-down asymmetrical 24-pulse ATRU is proposed in this paper. The connections and turns ratios among transformer windings are well designed. In addition, a 15-degree phase difference is formed between two of the 24 voltage vectors produced by the transformer, which makes the four rectifier bridge groups produce a 24-pulse DC voltage without interphase reactors. Meanwhile, by adding extended winding to each phase of the transformer, wide-range regulation of the ATRU output voltage can be realized, and the reasonable voltage regulation range is between 0.2 and 1.6. The superposition of the voltage vectors and the principle of the voltage regulation are analyzed in detail. Furthermore, the turns ratio of the windings, winding current, output voltage, and kilovolt-ampere rating are all derived. Finally, the simulations and experiments are carried out, and the correctness of the principle and theoretical analysis of the new 24-pulse ATRU are verified.

High Efficiency and Low Device Stress Voltage and Current Clamping ZVS PWM Asymmetrical Half Bridge Converter

  • Han Sang Kyoo;Moon Gun-Woo;Youn Myung Joong
    • Proceedings of the KIPE Conference
    • /
    • 2004.07a
    • /
    • pp.341-345
    • /
    • 2004
  • A high efficiency and low device stress voltage and current clamping BVS PWM asymmetrical half bridge converter is proposed in this paper. To achieve the ZVS of power switches along the wide load range, the transformer leakage inductor $L_{Ikg}$ is increased. Then, to solve the problem related to ringing in the secondary rectifier caused by the resonance between $L_{Ikg}$ and rectifier junction capacitors, the proposed converter employs a voltage and current clamping cell, which helps voltages and currents of rectifier diodes to be clamped at the output voltage and output current, respectively. Therefore, no RC-snubber for rectifier diodes is needed and a high efficiency as well as low noise output voltage can be realized. In addition, since all energy stored in $L_{Ikg}$ is transferred to the output side, the circulating energy problem can be effectively solved and duty loss does net exist. The operational principle, theoretical analysis, and design considerations are presented. To confirm the operation, validity, and features of the proposed circuit, experimental results from a 425W, 385-170Vdc prototype are presented.

  • PDF

Synchronous Control of an Asymmetrical Dual Redundant EHA (비대칭 이중화 EHA의 동기 제어)

  • Lee, Seong Ryeol;Hong, Yeh Sun
    • Journal of Drive and Control
    • /
    • v.13 no.2
    • /
    • pp.1-9
    • /
    • 2016
  • In this paper, an elementary force fighting problem was investigated. The problem is encountered when a double-rod type EHA(electro-hydrostatic actuator) is combined with a single-rod type EHA to build a redundant actuator system with synchronized motion. When the rod-side chambers of the two different types of EHAs have the same effective piston areas and are simultaneously pressurized by an external load, the two EHAs behave identically, sharing the external load equally. However, when the piston head-side chamber of the single rod type EHA, having a larger effective area than the rod-side chamber, is pressurized by the external load, an abnormal force fighting between the two EHAs occurs, unless their pump speeds are properly decoupled. In this study, the output drive forces of each EHA were obtained from the cylinder pressure signals and applied to the position control for each EHA to maintain the balance between their pump speeds. Adding minor force difference feedback loops to the position control, the force fighting phenomena could be eliminated and steady state synchronization errors were reduced. The power consumption of the pumps also could be remarkably reduced, avoiding unnecessarily high load pressures to the pumps.

Three Phase Drive Transfer Algorithm for Fault Tolerance Control of Six-Phase PMSM (6상 영구자석 동기전동기의 고장대응운전을 위한 3상 구동시스템 전환 알고리즘)

  • Kim, Seong-Hoon;Jang, Won-Jin;Cho, Kwan-Yuhl;Kim, Hag-Wone
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.4
    • /
    • pp.256-262
    • /
    • 2021
  • Six-phase motors can be used in industrial applications, such as an electric vehicle, due to their high reliability and low current magnitude per phase. An asymmetrical PMSM with two sets of three-phase windings is a commonly used structure for six-phase motors, with each winding set demonstrating a phase difference of 30°. Although the asymmetrical PMSM presents low torque ripples, its dynamic torque response deteriorates due to coupled components in the two three-phase windings. The decoupled VSD control is applied to eliminate the coupling effect. Load ratio control of two inverters for the six-phase PMSM is proposed in this study. DQ currents are controlled on the basis of two synchronous reference frames, and the six-phase drive system can be changed to a three-phase drive system when one inverter presents fault conditions. The operation and effectiveness of the proposed algorithm is verified through simulation and experiments. The six-phase drive system is transferred to a three-phase drive system by changing the current reference of the second DQ reference frame. Moreover, control of both torque and speed exhibits satisfactory performance before and after the mode change.

Switching Angle for Maximizing Torque, Efficiency and Minimizing Torque Ripple in SRM Drive (SRM의 최대 토크, 효율 및 최소 토크리플 운전을 위한 스위칭 각)

  • 김현덕;차현록;김광헌;나석환;임영철
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.151-154
    • /
    • 1999
  • This paper presents a driving method of 3-phase 4-poles SRM(switched reluctance motor) drived by switching angle control. In this study, the switching angle is determined from approximated analysis and computer simulation by using MATLAB for high efficiency according to the speed and torque required by load, and then microcontroller controls the switching angle of asymmetrical inverter in SRM driver. Also, we experiment the maximum forque driving and maximum power driving by controlling switching angle available to electric vehicle.

  • PDF

North Korean military provocations and the corresponding direction - Focus on the threat that resulted in unequal power wood box mines provocation - (북한군의 군사적 도발 및 대응방향 - 목함 지뢰 도발에 이어진 비대칭전력 위협을 중심으로-)

  • Kim, Gyu Nam
    • Convergence Security Journal
    • /
    • v.15 no.6_1
    • /
    • pp.59-67
    • /
    • 2015
  • Our vision is to see the North and there is a large visual target that the two exchanges and cooperation and unity that put the main enemy of enemies in mind in need. North Korea is the main enemy was illegal invasion June 25, 1950 July 27, 1953 has continued after the armistice join the illegal provocations and cease fire violations so far. August 4, 2015, North Korea was operating by the power differential that operate on an all-out war and declared the initial state after the exhibition gave another provocative DMZ wood box mines. US-ROK military was in the process of real-time detection of the North Korean power operation and the results were broadcast live through the media. Looking at these military provocations on the threat of asymmetrical power of North Korea's military threat, we would like to present how to respond.

High Efficiency Power Conversion System for Battery-Ultracapacitor Hybrid Energy Storages (배터리-울트라커패시터 하이브리드 에너지 저장장치를 위한 고효율 전력변환 시스템)

  • Yoo, Ju-Seung;Choi, Woo-Young
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.6
    • /
    • pp.523-531
    • /
    • 2012
  • This paper proposes a high efficiency power conversion system for battery-ultracapacitor hybrid energy storages. The proposed system has only one bidirectional dc-dc converter for hybrid power source with batteries and ultracapacitors. The hybrid power source has bidirectional switching circuits for selecting one energy storage device. Bidirectional power flow between the energy storage device and high voltage capacitor can be controlled by one bidirectional converter. An asymmetrical switching method is applied to the bidirectional converter for high power efficiency. Switching power losses are reduced by zero-voltage switching of power switches. System operation and design considerations are presented. The experimental results are provided to verify the performance of the proposed system.

A Study on the Unbalanced Current Distribution of HTS Power Cable (초전도 전력케이블의 전류 불평형에 관한 연구)

  • Kim, Jae-Ho;Park, Chung-Hwa
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.6
    • /
    • pp.43-47
    • /
    • 2012
  • The unbalance currents flow the High Temperature Superconducting (HTS) power cable caused by asymmetrical fault, harmonic distortion and unbalanced load. That problem causes additional loss and leakage field in the HTS power cable, and deteriorates the electric power quality and stability. In addition, large amounts of unbalanced current can cause negative sequence and ground relays to operate. This paper presents an analysis unbalanced three-phase current distribution in HTS power cable caused by unbalanced load condition and grounding methods using PSCAD/EMTDC. The results obtained through the analysis would provide important data for the design of HTS power cables and valid information for their installation in power system.