• Title/Summary/Keyword: asymmetric load

Search Result 179, Processing Time 0.015 seconds

Effects of Load Center of Gravity and Feet Positions on Peak EMG Amplitude at Low Back Muscles While Lifting Heavy Materials (중량물 들기 작업시 물체 무게중심 및 발의 위치가 허리 근육의 최대 EMG 진폭에 미치는 영향)

  • Kim, Sun-Uk;Han, Seung Jo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.22 no.3
    • /
    • pp.257-264
    • /
    • 2012
  • Objectives: This study's aims were to evaluate the effects of load center of gravity within an object lifted and feet placements on peak EMG amplitude acting on bilateral low back muscle groups, and to suggest adequate foot strategies with an aim to reducing low back pain incidence while lifting asymmetric load. Methods: The hypotheses that asymmetric load imposes more peak EMG amplitude on low back muscles contralateral to load center of gravity than symmetric load and maximum peak EMG amplitude out of bilateral ones can be relieved by locating one foot close to load center of gravity in front of the other were established based on biomechanics including safety margin model and previous researches. 11 male subjects were required to lift symmetrically a 15.8kg object during 2sec according to each conditions; symmetric load-parallel feet (SP), asymmetric load-parallel feet (AP), asymmetric load-one foot contralateral to load center of gravity in front of the other (AL), and asymmetric load-one foot ipsilateral to load center of gravity in front of the other (AR). Bilateral longissimus, iliocostalis, and multifidus on right and left low back area were selected as target muscles, and asymmetric load had load center of gravity 10cm deviated to the right from the center in the frontal plane. Results: Greater peak EMG amplitude in left muscle group than in right one was observed due to the effect of load center of gravity, and mean peak EMG amplitudes on both sides was not affected by load center of gravity because of EMG balancing effect. However, the difference of peak EMG amplitudes between both sides was significantly affected by it. Maximum peak EMG amplitude out of both sides and the difference of peak EMG amplitude between both sides could be reduced with keeping one foot ipsilateral to load center of gravity in front of the other while lifting asymmetric load. Conclusions: It was likely that asymmetric load lead to the elevated incidence of low back pain in comparison with symmetric load based on maximum peak EMG amplitude occurrence and greater imbalanced peak EMG amplitude between both sides. Changing feet positions according to the location of load center of gravity was suggested as one intervention able to reduce the low back pain incidence.

Buckling Load of Lattice Timber Roof Structure considering Stiffness of Connection with Asymmetric Snow Load (접합부 강성과 비대칭 적설하중 적용을 통한 목조 래티스 지붕 구조물의 좌굴하중 특성)

  • Hwang, Kyung-Ju
    • Journal of Korean Association for Spatial Structures
    • /
    • v.23 no.1
    • /
    • pp.69-76
    • /
    • 2023
  • A timber lattice roof, which has around 30m span, was constructed. In order to figure out the realistic buckling load level, the structural analysis of this roof structure was performed especially by stiffness of connection with various asymmetric snow load. Due to the characteristics of application of snow load, the load combinations of snow should be considered not only global area but also local part so that the critical buckling load could be observed as easy as possible. Geometrical imperfection was simulated to consider inaccurate shape of structure. And then nonlinear analysis were performed. Finally, this paper could investigate that the asymmetric snow load with the lower level stiffness of connection decreased the level of buckling load significantly.

Assessing asymmetric steel angle strength under biaxial eccentric loading

  • Shu-Ti Chung;Wei-Ting Hsu
    • Structural Engineering and Mechanics
    • /
    • v.91 no.5
    • /
    • pp.517-526
    • /
    • 2024
  • Due to the asymmetric cross-section of unequal-angle steel, the application of loads can induce axial rotation, leading to a series of buckling failure behaviors. Special attention must be paid during the design process. The present study aims to analyze the structural behavior of asymmetric steel angle members under various eccentric loading conditions, considering the complex biaxial bending interaction that arises when the angle steel is connected to the panel. Several key factors are investigated in this paper, including the effects of uniaxial and biaxial eccentricity on the structural behavior and the eccentric axial compression strength of long and short legs at different load application points. Potential risks associated with the specified load points, based on the AISC specifications, are also discussed. The study observed that the strength values of the members exhibited significant changes when the eccentric load deviates from the specified point. The relative position of the eccentric load point and the slenderness ratio of the member are critical influencing factors. Overall, this research intends to enhance the accuracy and reliability of strength analysis methods for asymmetric single angle steel members, providing valuable insights and guidance for a safer and more efficient design.

Autotuning algorithm for asymmetric output using saturation function (비대칭 출력부하에 대한 포화함수를 이용한 자동동조 알고리듬)

  • Oh, Seung-Rohk;Oh, Dong-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2005.05a
    • /
    • pp.141-143
    • /
    • 2005
  • An unknown linear time invariant plant with asymmetric oscillation in the output such as a static load disturbance. A saturation function nonlinear element is used to find the one point information in the frequency domain. An asymmetric self-oscillation caused by such as a static load disturbance saturation function feedback is analyzed. a new method to tune a PID controller based on the analysis is proposed in the presence of asymmetric oscillation. The proposed method does not require the knowledge of plant d.c. gain with an asymmetric oscillation in the plant output.

  • PDF

A Study on the Muscle Activity During Asymmetric Load Handling (허리의 비틀림 각도에 따른 근육 활동 분석)

  • 장성록;박현진
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.2
    • /
    • pp.117-120
    • /
    • 2001
  • Low back pain has been known as the most frequent musuculoskeletal disorders in modern industrial society and cost by low back pain is increasing mon and more. The asymmetric lifting has been identified as a major risk factor of low back pain. In this study, the muscle activity and muscle exertion level during asymmetric load handling (without trunk flexion) was estimated. The results of normalized MVC measurement were decreased about 16%, 24%, 34% respectively as the asymmetric angle was $30^{\circ}$, $60^{\circ}$, $90^{\circ}$. From the results of EMG measurement contralateral muscles were more active than ipsilateral muscles. RMSEMG values of right erector spinae muscles were decreased as the work posture went to 90$^{\circ}$ and those of left erector spinae muscles were increased until the asymmetric angle was 40$^{\circ}$ but decreased continually over 40$^{\circ}$. And for seven of subjects, activities of left and right latissimus dorsi muscles were maintained constantly, while for remainer, those were irregular.

  • PDF

Comparison of Peak EMG Amplitude on Low Back Muscles according to Asymmetric Load Center of Gravity and Trunk Lateral Bending while Lifting (들기 작업시 중량물의 비대칭 무게중심 및 상체 옆으로 기울임에 따른 허리근육의 Peak EMG 진폭 비교)

  • Han, Seung Jo;Kim, Sun-Uk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.10
    • /
    • pp.4629-4635
    • /
    • 2012
  • This study was aimed at the relationship between peak EMG amplitude on low back muscles acting on L5/S1 and load center of gravity, trunk lateral bending while lifting an object. Musculoskeletal disorders including low back pain can occur even when handling heavy objects only once as well as when doing non-heavy materials repeatedly. 11 male subjects with average 23 age were required to lift a 15.8kg object symmetrically three times. Peak EMG amplitudes on 6 muscles related with L5/S1 were recorded and analyzed. The lifting conditions consisted of lifting symmetric load with no trunk lateral bending, asymmetric load with no trunk lateral bending, and asymmetric load with trunk lateral bending to the load center of gravity within an object. The results showed that peak EMG amplitude on back muscles contralateral to load center of gravity was observed greater in comparison with the symmetric load. Also, in case of lifting asymmetric load the posture with trunk lateral bending increased peak EMG amplitude on muscles contralateral to load center of gravity more than with no trunk lateral bending. This research can be used as one administrative intervention in order to reduce the low back pain incidence with suggesting workers that they keep the trunk not bending to load center of gravity if possible when lifting a heavy asymmetric object.

Field Applicability Evaluation of Monotype Load Cell for Load-Distributing Anchor (하중 분산형 앵커 내하체에 대한 모노타입 하중계의 현장 적용성 평가)

  • Yong-Jae Song;Kang-Il Lee;Yong-Chai Chang;Sang-Yong Kim
    • Journal of the Korean Geosynthetics Society
    • /
    • v.23 no.3
    • /
    • pp.23-30
    • /
    • 2024
  • According to the method of settling the construction structure on the ground to keep the structure safe, the ground anchor method is divided into a load-distributing anchor and a general anchor. Recently, the application of load-distributed anchors, which show a large degree of recognition by anchors, is increasing in the field, but the problem of field applicability is also caused. The load-distributed anchor fixes the tensile force to each section of the lecture line and applies it, causing a problem of asymmetric loads in which the maximum tensile force size of each settlement site differs due to the length difference of the anchor body. Therefore, in this study, as a quality management method according to the asymmetric load of anchors, a mono-type load cell that can measure the load for each lecture line of a load-distributed anchor was developed, and the field applicability was analyzed by comparing and analyzing the measurement results of the existing multi-type load cell and mono-type load cell. As a result of the study, the multi-type load cell had no choice but to estimate the working load for each inner body, so it was impossible for the load-distributed anchor to manage it according to the generation of asymmetric loads for each lecture line. However, in the case of a mono-type load cell the load was measured for each inner body and for each lecture line, regardless of ground conditions and construction conditions, and thus the load value was measured for each lecture line, enabling safety management and construction management according to the occurrence of asymmetric loads.

The Analysis of Low Back Loading and Muscle Fatigue while Lifting an Asymmetric Load (비대칭무게중심을 지닌 물체 들기 작업시 허리부위 등근육 부하 및 피로 분석)

  • Han, Seung-Jo;Kim, Sun-Uk
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.35 no.2
    • /
    • pp.30-36
    • /
    • 2012
  • This study is aimed to show that an asymmetric load in the frontal plane leads to an increase in low back loading and fatigue in comparison with a symmetric load when workers lift an external weight by investigating previous studies and verifying the phenomenon with an experiment. Ten male subjects are required to lift and hold an given external load at 70cm height during 50sec, then the EMG amplitude and median frequency on bilateral low back muscle groups (Longissimus, Iliocostalis, and Multifidus) are recorded and analyzed. Independent variables are two-level load weight (13kg, 20kg) and three-level LCG (Center, 6.5cm to the right, and 13cm to the right), and dependent variables are EMG amplitude average, difference, and Fatigue Index (FI). Results show that load weight increases significantly amplitude average and FI, but LCG does significantly amplitude difference and FI significantly (P-value < 0.05). Also the correlation coefficient between amplitude difference and FI is over 0.99. These implies that trunk loading should be explained by not EMG amplitude but muscle fatigue aspect since the association between an external load and amplitude is linear, but the relationship between an external load and median frequency as muscle fatigue index is almost exponential.

PID Autotuning Based on Saturation Function Feedback with A Static Load Disturbance (정적 부하왜란이 있는 경우의 포화함수를 이용한 PID 자동동조)

  • Oh, Seung- Rohk
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.51 no.12
    • /
    • pp.542-548
    • /
    • 2002
  • We consider an unknown linear time invariant plan with static load disturbance. A saturation function nonlinear element is sued to find th one point information in the frequency domain. We analyze an asymmetric self-oscillation caused by static load disturbance with relay feedback and saturation function feedback. We propose a new method to tune a PID controller using a saturation nonlinear feedback element in the presence of asymmetric oscillation. The proposed method does not require the knowledge of plant d.c. gain with an asymmetric oscillation in the plat output.

Design and Verification of Improved Cascaded Multilevel Inverter Topology with Asymmetric DC Sources

  • Tarmizi, Tarmizi;Taib, Soib;Desa, M.K. Mat
    • Journal of Power Electronics
    • /
    • v.19 no.5
    • /
    • pp.1074-1086
    • /
    • 2019
  • This paper presents the design and implementation of an improved cascaded multilevel inverter topology with asymmetric DC sources. This experimental inverter topology is a stand-alone system with simulations and experiments performed using resistance loads. The topology uses four asymmetric binary DC sources that are independent from each other and one H-bridge. The topology was simulated using PSIM software before an actual prototype circuit was tested. The proposed topology was shown to be very efficient. It was able to generate a smooth output waveform up to 31 levels with only eight switches. The obtained simulation and experimental results are almost identical. In a 1,200W ($48.3{\Omega}$) resistive load application, the THDv and efficiency of the topology were found to be 1.7% and 97%, respectively. In inductive load applications, the THDv values were 1.1% and 1.3% for an inductive load ($R=54{\Omega}$ dan L=146mH) and a 36W fluorescent lamp load with a capacitor connected at the dc bus.