• Title/Summary/Keyword: asymmetric changes

Search Result 176, Processing Time 0.032 seconds

Improvement of Current Velocity Estimation Method in an ADCP (ADCP에서의 유속 추정 방법 개선에 관한 연구)

  • Lee, Jonggil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.9
    • /
    • pp.1818-1825
    • /
    • 2017
  • An Acoustic Doppler Current Profiler(ADCP) measures the current velocity and analyzes the degree of turbulence using Doppler effects of ultrasonic waves. Therefore, the autocorrelation or FFT spectrum estimates are obtained for extraction of current velocity in each spatial region. However, if the correlation method does not satisfy the assumption that the return signal spectra are symmetric Gaussian, the large bias errors can occur. Also, the accurate estimation of autocorrelation or FFT spectrum is difficult due to the short acquisition interval when the rapid changes of current velocity occur. Thus, in this paper, the estimation method of the autoregressive spectrum peak is suggested for the accurate current velocity measurement of both symmetric and asymmetric spectra. It is shown that estimation quality can be improved using the suggested method comparing with the conventional methods. Many return signals under the various environment are simulated and the results are compared and analyzed for evaluation of the suggested method.

A Study on the Developing Method of HIF Monitoring Data using Wavelet Coefficient (웨이브렛 계수를 이용한 고저항 지락고장 감시데이터 산출방법 연구)

  • Jung, Young-Beom;Jung, Yeon-Ha;Kim, Kil-Sin;Lee, Byung-Sung;Bae, Seung-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.2
    • /
    • pp.155-163
    • /
    • 2013
  • As the increasing HIF(High Impedance Fault) with the arc cannot be easily detected for the low fault current magnitude compared to actual load in distribution line. However, the arcing current shows that the magnitude varies with time and the signal is asymmetric. In addition, discontinuous changes occur at starting point of arc. Considering these characteristics, wavelet transformation of actual current data shows difference between before and after the fault. Althogh raw data(detail coefficient) of wavelet transform may not be directly applied to HIF detection logic in a device, there are several developing methods of HIF monitoring data using the original wavelet coefficients. In this paper, a simple and effective developing methods of HIF monitoring data were analized by using the signal data through an actual HIF experiment to apply them to economic devices. The methods using the sumation of the wavelet coefficient squares in one cycle of the fundamental frequency as the energies of the wavelet coefficeits and the sumation of the absolute values were compared. Besides, the improved method which less occupies H/W resouces and can be applied to field detection devices was proposed. and also Verification of this HIF detection method through field test on distribution system in KEPCO power testing center was performed.

A Polarity Based Blind Watermarking Method Considering Wavelet Coefficients Change (웨이블릿 계수 변화량을 고려한 극성 기반 블라인드 워터마킹 기법)

  • 신창둔
    • Journal of Korea Multimedia Society
    • /
    • v.7 no.5
    • /
    • pp.744-754
    • /
    • 2004
  • In this paper, a polarity based blind watermarking method considering wavelet coefficients modification is proposed. In this proposed method, we use an asymmetric thresholds watermarking(ATW) in which detection threshold is higher than inserting threshold in order to enhance watermark detection ratio in attacked images. Also, in order to reduce errors in the detected value of watermarks according to small changes in the coefficient values when detecting watermarks, it set the range for movement variation of the coefficients and lowered the sensitivity of variation by ignoring the variations that fall into this range. For this purpose, the polarity preservation threshold $\beta$ was set and a watermark was detected based on the polarity only for the difference that was larger than $\beta$. The experimental results show that the proposed method has good quality and is robust to various attacks such as the JPEG lossy compression, noise addition, cropping, blurring, etc.

  • PDF

Carbon-13 Nuclear Magnetic Resonance Spectroscopic Studies of $^{13}CO$ Adsorbed on Platinum Particles in L-Zeolites

  • 한옥희;Gustavo Larsen;Gary L. Haller;Kurt W. Zilm
    • Bulletin of the Korean Chemical Society
    • /
    • v.19 no.9
    • /
    • pp.934-942
    • /
    • 1998
  • $^13CO$ chemisorbed on platinum particles in L-zeolite has been investigated by static and magic angle spinning NMR spectroscopy. The representative spectra are composed of a broad asymmetric peak with a center of gravity at 230±30 ppm and a sharp symmetric peak at 124±2 ppm which is tentatively assigned to physisorbed $CO_2$, on inner walls of L-zeolite. Overall, the broad resonance component is similar to our previous results of highly dispersed (80-96%) CO/Pt/silica or CO/Pt/alumina samples, still showing metallic characters. The principal difference is in the first moment value. The broad peak in the spectra is assigned to CO linearly bound to Pt particles in the L-zeolites, and indicates a distribution of isotropic shifts from bonding site to bonding site. The NMR results reported here manifest that the Pt particles inside of the L-zeolites channels are not collectively the same with the ones supported on silica or alumina with similar dispersion in terms of Pt particle shape and/or ordering of Pt atoms in a particle. As a result, Pt particles of CO/Pt/L-zeolite were agglomerated accompanying CO desorption upon annealing. There were no definite changes in the NMR spectra due to differences of exchanged cations. Comparison of our observation on CO/Pt/L-zeolite with Sharma et al.'s reveals that even when the first moment, the linewidtb, and the relaxation times of the static spectra and the dispersion measured by chemisorption are similar, the properties of Pt particles can be dramatically different. Therefore, it is essential to take advantage of the strengths of several techniques together in order to interpret data reliably, especially for the highly dispersed samples.

Investigation on the Correlation between the Housing and Stock Markets (주택시장과 주식시장 사이의 상관관계에 관한 연구)

  • Kim, Sang Bae
    • Korea Real Estate Review
    • /
    • v.28 no.2
    • /
    • pp.21-34
    • /
    • 2018
  • The purpose of this study is to investigate the effect of macro-finance variables on the correlation between the housing and stock markets because understanding the nature of time-varying correlations between different assets has important implications on portfolio allocation and risk management. Thus, we adopted the AG-DCC GARCH model to obtain time-varying, conditional correlations. Our sample ranged from January 2004 to November 2017. Our empirical result showed that the coefficients on asymmetric correlation were significantly positive, implying that correlations between the housing and stock markets were significantly higher when changes in the housing price and stock returns were negative. This finding suggested that the housing market has less hedging potential during a stock market downturn, when such a hedging strategy might be necessary. Based on the regression analysis, we found that the term spread had a significantly negative effect on correlations, while the credit spread had a significantly positive effect. This result could be interpreted by the risk premium effect.

Effects of Unilateral Step Treadmill Training on the Gait Speed and Recovery of Gait Symmetry in Patients with Chronic Stroke (편측성 걸음걸이 트레드밀 훈련이 만성 뇌졸중 환자의 보행 속도와 대칭성 회복에 미치는 효과)

  • Lee, Ji-Yeon;Chon, Seung-Chul
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.10 no.4
    • /
    • pp.145-151
    • /
    • 2022
  • Purpose : Stroke patients exhibit abnormal walking patterns such as slow walking speed and asymmetrical walking values. The recovery of symmetrical walking in the stance phase using a treadmill means improvements in walking speed and asymmetrical walking. The purpose of this research was to investigate the effect of unilateral step treadmill training (USTT) on gait speed and the recovery of symmetrical walking in chronic stroke patients. Methods : Fifteen patients (11 men and 4 women) with chronic stroke participated in this study. The 10-meter walk test (10MWT) and GAITRite system were used to determine the intervention-related changes in gait speed and symmetrical walking values such as non-paretic step length (NSL), non-paretic step time (NST), paretic single-support time (PSST), step length asymmetry (SLA), and step time asymmetry (STA) after USTT. All participants completed USTT and underwent measurements at 3 different times: at pretest, posttest, and the follow-up test. Repeated-measures analysis of variance was used to compare walking speed and asymmetrical walking values. The statistical significance level was set at p<.05. Results : Walking speed by 10MWT (p<.05) showed significant improvements after USTT as follows: at pretest and posttest (p<.05), posttest and follow-up test (p<.05), and pretest and follow-up test (p<.05). Recovery of symmetrical walking patterns such as NSL (p<.05), NST (p<.05), and SLA (p<.05) were observed after USTT. However, no significant improvements were found in PSST (p>.05) and STA (p>.05) in symmetrical gait. Conclusion : This study suggests that USTT may have a positive effect on walking speed and symmetrical walking patterns in chronic stroke patients. Thus, this study contributes to the existing knowledge about the usefulness of USTT for the effective management of patients with chronic stroke. Further studies are needed to generalize these findings.

Pressure Drop and Leakage Performances of Flat Seals with Inclined Grooves (경사 그루브를 갖는 평판 실의 압력 강하 및 누설 성능)

  • Jung, Jin Woo;Jeong, Gwon Jong;Hwang, Sung Ho;Kim, Tae Ho;Kim, Eojin
    • Tribology and Lubricants
    • /
    • v.38 no.5
    • /
    • pp.213-221
    • /
    • 2022
  • This paper presents performance measurements of pressure drop and leakage flow rate of test flat seals with asymmetric inclined grooves. This study aims to reveal the influence of groove shapes, often machined in radial film riding-face seals, in forming a hydrodynamic wedge on leakage performance. A test facility was developed, and test seals were manufactured to study the effects of the inlet pressure level, ratio of inlet to outlet pressure, seal groove length, and seal groove height on the steady-state pressure drop and leakage performance. A series of tests were conducted, and the test data were compared to the predictions from a simple and efficient mathematical model using a one-dimensional Reynolds equation. The test results revealed that an increase in the inlet pressure increased the pressure drop through the test seals. The leakage flow rate increased significantly as the inlet pressure and ratio of the inlet to outlet pressure increased. The groove shape also affects seal performance. An increase in the groove length and height resulted in an evident increase in the leakage flow rate. The simple model predictions underestimated the leakage flow rates but showed good agreement with the trend in the measurements for all test operating conditions and changes in the groove shape.

Effect of Smart-phone Use According to Types of Carrying a Bag on Muscle Characteristics and Balance Ability in Adults in Their 20S with Chronic Ankle Instability (가방 착용 방향에 따른 스마트폰의 사용이 만성 발목 불안정성을 가진 20대 성인의 근육 특성과 균형 능력에 미치는 영향)

  • Beom-Cheol Jeong;Jae-Ha Kim;Kyung-Tae Yoo
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.18 no.2
    • /
    • pp.83-92
    • /
    • 2023
  • PURPOSE: This study examined the effect of using a smartphone according to the direction of wearing a bag on muscle characteristics and balance ability in adults in their 20s with chronic ankle instability. METHODS: Twelve people with chronic ankle instability were examined for three weeks. The types of carrying a bag were classified into three conditions: to the right, to the left, and on both sides. The muscle characteristics and balance ability were measured and analyzed. The one-way ANOVA was used to obtain a difference between conditions. RESULTS: A significant difference in the muscle tone of medial gastrocnemius was observed between the dominant group and the non-dominant group. The muscle tone and stiffness of the peroneus longus decreased significantly after walking with a smartphone and carrying a bag. The maximum slope of the forward and reverse directions increased and decreased significantly, respectively, after walking with a smartphone and carrying a bag on both sides. CONCLUSION: In this study, muscle fatigue causes a decrease in muscle tone and stiffness with chronic ankle instability when carrying a heavy back while walking, and there were asymmetric changes in the balance ability. Therefore, adults with chronic ankle instability should carefully avoid carrying a heavy bag for extended times, irrespective of the style or type of the bag.

Asymmetric Signal Scanning Scheme to Detect Invasive Attacks (침투 공격 검출을 위한 비대칭 신호 스캐닝 기법)

  • Da Bin Yang;Ga Young Lee;Young-woo Lee
    • Smart Media Journal
    • /
    • v.12 no.1
    • /
    • pp.17-23
    • /
    • 2023
  • Design-For-Security (DFS) methodology is to protect integrated circuits from physical attacks, and that can be implemented by adding a security circuit to detect abnormal external access. Among the abnormal accesses called invasive attack, microprobing and FIB circuit editing are classified as the most powerful methods because they have direct access. Microprobing deliberately inject defects into the wire of circuit through probes, or reads and changes data. FIB circuit editing is methods of reconnecting or destroying circuits to neutralize security circuits or to access data. Previous DFS methodology have responded to the attacks by detecting arrival time asymmetry between the two signals or by comparing input/output data based on encrypted communication. This study conducted to reduce hardware overhead, and the proposed circuit detects the reflected signal asymmetry generated through probe or FIB circuit editing and detects the attacks through comparison. Since the proposed security circuit reduces the size and test cycle of the circuit compared to previous studies, the cost used for security can be reduced.

Analysis Method of X-Ray Diffraction Characteristic Values and Measured Strain for Steep Stress Gradient of Metal Material Surface Layer (금속재료 표면층의 급격한 응력구배에 대한 X-Ray회절 특성값과 측정된 변형률의 해석방법)

  • Chang-Suk Han;Chan-Woo Lee
    • Korean Journal of Materials Research
    • /
    • v.33 no.2
    • /
    • pp.54-62
    • /
    • 2023
  • The most comprehensive and particularly reliable method for non-destructively measuring the residual stress of the surface layer of metals is the sin2ψ method. When X-rays were used the relationship of εφψ-sin2ψ measured on the surface layer of the processing metal did not show linearity when the sin2ψ method was used. In this case, since the effective penetration depth changes according to the changing direction of the incident X-ray, σφ becomes a sin2ψ function. Since σφ cannot be used as a constant, the relationship in εφψ-sin2ψ cannot be linear. Therefore, in this paper, the orthogonal function method according to Warren's diffraction theory and the basic profile of normal distribution were synthesized, and the X-ray diffraction profile was calculated and reviewed when there was a linear strain (stress) gradient on the surface. When there is a strain gradient, the X-ray diffraction profile becomes asymmetric, and as a result, the peak position, the position of half-maximum, and the centroid position show different values. The difference between the peak position and the centroid position appeared more clearly as the strain (stress) gradient became larger, and the basic profile width was smaller. The weighted average strain enables stress analysis when there is a strain (stress) gradient, based on the strain value corresponding to the centroid position of the diffracted X-rays. At the 1/5 Imax max height of X-ray diffraction, the position where the diffracted X-ray is divided into two by drawing a straight line parallel to the background, corresponds approximately to the centroid position.