• Title/Summary/Keyword: assist-control

Search Result 454, Processing Time 0.029 seconds

Fundamental wheel Control for Artificial Life-robot

  • Kubik, Tomasz;Loukianov, Andrey A.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.36.1-36
    • /
    • 2001
  • Recently the robot industry has developed quickly. There are robots carrying luggage at factories, the amusement robots (such as the pet-type robot) in the house, and so on. As the ability of computers improve, robot ability also improves, because mary calculations can be done in little time. Consequently robots can perform complex motions by various control methods. The robot in our laboratory was developed in order to assist various works in a hospital. We controlled our robot using PID control method. So this paper is written about PID control.

  • PDF

IOT Intelligent Watering Sensor For Indoor Plant

  • Hana, Mujlid;Haneen Daifallah, Alghamdi;Hind Abdulaziz, Alkharashi;Marah Awadh, Alkhaldi
    • International Journal of Computer Science & Network Security
    • /
    • v.22 no.12
    • /
    • pp.171-177
    • /
    • 2022
  • The number of people who own indoor plants is growing today, but as a result of their busy lifestyles-such as work or travel-as well as a lack of enthusiasm in caring for their plants, their plants wither. The use of an irrigation control system with a surveillance camera can assist such folks in taking care of their plants. Such a device can assist in remotely watering plants at predetermined times and checking on the health of the plants. The proprietors would be able to live comfortably without feeling bad thanks to this change. Internet access is required for this technology in order to monitor the plants and control the watering through apps. A sensor is installed in the soil to monitor soil humidity and send data to the microcontroller for irrigation, allowing the owner to schedule irrigation as they see fit and keep an eye on their plants all day. With the use of a remote irrigation control system, the plants will grow properly and be irrigated with the proper amount of water, and the owners will be so glad and delighted to watch their plants. Knowing the time and quantity of water are vital parts of the plant growth.

A Study on the Spray Behavior of Air-Assist Type Gasoline Fuel Injector in Intake Port (공기보조형 가솔린 연료분사기의 흡기포트내 연료분무 거동에 관한 연구)

  • Rho, Byung-Joon;Kang, Shin-Jae;Kim, Won-Tae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.1
    • /
    • pp.92-103
    • /
    • 1999
  • The fuel spray behavior in the intake port of an electronic control port irijection gasoline engine has a strong influence on engine performance, exhaust emission and fuel consumption. Thus, in this study, fuel spray behavior and flow characteristics of the air assist gasoline spray injected into a suction flow in a simulated rectangular intake port have boon investigated. Macro-behavior of spray characteristics was investigated by means of visualization and the measurements of SMD and velocity were made by PDPA. For analysis the flow field with droplets size, droplets are classified five droplets size groups. As a result, the normal distance of suction flow increasing, the relatively large droplets distribution and SMD increase because small droplets easily follow suction flow. Near impinging wail, after impinging against the wall, secondary atomized small droplets of D < $30{\mu}m$ bound from the wall. And the increasement of suction flow progress to the large droplets of D > $100{\mu}m$ distribution. Therefore, SMD are apparently increased near impinging wall, Z/d = 9.0.

A study on the development of motor-driven artificial heart and its control (인공심장의 자동제어)

  • 민병구;김희찬;권성일
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1986.10a
    • /
    • pp.643-647
    • /
    • 1986
  • A new type of motor-driven Total Artificial Heart (TAH) system with rolling-ball mechanism has been developed. To test its performance as a Left Ventricular Assist Device (LVAD), LVAD is controlled to bypass blood for impaired heart triggered by the R-wave in ECG. Results of the test with a Mock Circulation System (MCS) and an animal experiment with a dog are also included. More powerful system using a brushless DC motor has been developed and its control scheme is represented.

  • PDF

A Study on the Simulation Modeling Method of LKAS Test Evalution (LKAS 시험평가의 시뮬레이션 모델링 기법에 관한 연구)

  • Bae, Geon-Hwan;Lee, Seon-bong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.3
    • /
    • pp.57-64
    • /
    • 2020
  • The leading technologies of the ADAS (Advanced Driver Assist System) are ACC (Advanced Cruise Control), LKAS (Lane Keeping Assist System), and AEB (Autonomous Emergency Braking). LKAS is a system that uses cameras and infrared sensors to control steering and return to its running lane in the event of unintentional deviations. The actual test is performed for a safety evaluation and verification of the system. On the other hand, research on the system evaluation method is insufficient when an additional steering angle is applied. In this study, a model using Prescan was developed and simulated for the scenarios proposed in the preceding study. Comparative analyses of the simulation and the actual test were performed. As a result, the modeling validity was verified. A difference between the front wheels and the lane occurred due to the return velocity. The results revealed a maximum error of 0.56 m. The error occurred because the lateral velocity of the car was relatively small. On the other hand, the distance from wheels to the lanes displayed a tendency of approximately 0.5 m. This can be verified reliably.

Assist Torque Balance Control for Power Assisted Wheelchair Based on Temporal Similarity between Input Torques (입력토크의 시간적 유사성에 기반한 파워 어시스트 휠체어의 토크 밸런스 제어)

  • Heo, Y.;Hong, E.P.;Ryu, J.C.;Moon, M.S.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.9 no.1
    • /
    • pp.81-87
    • /
    • 2015
  • In order for a Power Assisted Wheelchair (PAW) to maintain a straight driving direction, the same force must be delivered to both wheels. However, a human has different strength between the right and left arms, and cannot control the force uniformly at all times. Therefore, appropriate assist torque shall be generated from unbalanced human torque inputs by detecting the user intention, in order to maintain direction uniformly in straight sections or change direction quickly in curved sections. In this study, a special function is proposed to detect the intention of drivers on the basis of temporal similarity between the input torque signals, and a torque balancing technique based on this function is proposed. In the experiments, the effectiveness of the proposed torque balancing method are verified.

  • PDF

A Study on Remote CO2 Laser Welding for the Development of Automobive Parts (차체부품 개발을 위한 원격 CO2 레이저 용접에 관한 연구)

  • Song, Mun-Jong;Lee, Gyu-Hyun;Lee, Mun-Yong;Kim, Sok-Won
    • Journal of Welding and Joining
    • /
    • v.28 no.5
    • /
    • pp.75-79
    • /
    • 2010
  • The Remote welding system(RWS) using $CO_2$ laser equipment has focusable distance of laser beam longer than 800 mm from workpiece and can deflect the laser beam by the scanner mirrors very rapidly. In the case of normal welding system based on robot, there is a limit to move the shortest path in short time and this causes interference between robot and workpiece. On the other hand, RWS is the optimized equipment to get big merits with advanced sequence of welding and short cycle time. However, there is still a pending task such as the control of plasma in the welding process of thick sheets therefore, it requires high power laser beam because of the absence of assist gas equipment in itself. In this study, high-tensile steel plates were overlap welded with $CO_2$ RWS for the production of car body and the influence of penetration depth according to the existence of assist gas was analyzed. Excellent tensile strength with enough width of molten zone independent to penetration depth was observed under welding condition with 3.6 kW laser power and 2.8 m/min welding speed without assist gas. Finally, the proto-type automotive parts were produced by applying the deduced optimal welding condition.

A Study on Safety and Performance Evaluation of Smart All-in-one Cardiopulmonary Assist Device (스마트올인원 심폐순환보조장치의 안전성 및 성능평가에 관한 연구)

  • Park, Junhyun;Ho, YeJi;Lee, Yerim;Lee, Duck Hee;Choi, Jaesoon
    • Journal of Biomedical Engineering Research
    • /
    • v.40 no.5
    • /
    • pp.197-205
    • /
    • 2019
  • The existing Extracorporeal membrane oxygenation(ECMO) and Cardiopulmonary bypass system(CPB) have been developed and applied to various devices according to their respective indications. However, due to the complicated configuration and difficult usage method, it causes inconvenience to users and there is a risk of an accident. Therefore, smart all-in-one cardiopulmonary circulation device is being developed recently. The smart all-in-one cardiopulmonary assist device consists of a blood pump for cardiopulmonary bypass, a blood oxidizer for cardiopulmonary bypass, a blood circuit for cardiopulmonary bypass, and an artificial cardiopulmonary device. It is an integrated cardiopulmonary bypass device that can be used for a variety of purposes such as emergency, intraoperative, post-operative intensive care, and long-term cardiopulmonary assist, combined with CPB used in open heart surgery and ECMO used when patient's cardiopulmonary function does not work normally. The smart all-in-one cardiopulmonary assist device does not exist as a standard and international standard applicable to advanced medical devices. Therefore, in this study, we will refer to the International Standard for Blood Components, the International Standard for Blood, the Guideline for Blood Products, and prepare applicable performance and safety guidelines to help quality control of medical devices, and contribute to the improvement of the health of people. The guideline, which is the result of conducted a survey of the method of safety and performance test, is based on the principle of all-in-one cardiopulmonary aiding device, related domestic foreign standards, the status of domestic and foreign patents, related literature, blood pump(ISO 18242), blood oxygenator (ISO 7199), and blood circuit (ISO 15676) for cardiopulmonary bypass.The items on blood safety are as follows: American Society for Testing and Materials ASTM F1841-97R17), and in the 2010 Food and Drug Administration's Safety Assessment Guidelines for Medical Assisted Circulatory Devices. In addition, after reviewing the guidelines drawn up through expert consultation bodies including manufacturers / importers, testing inspectors, academia, etc. the final guideline was established through revision and supplementation process. Therefore, we propose guidelines for evaluating the safety and performance of smart all-in-one cardiopulmonary assist devices in line with growing technology.

Torque Control Simulation of the Column Type EPS System using MATLAB/Simulink (MATLAB/Simulink를 이용한 컬럼형 전동조향장치(EPS)의 토크제어 시뮬레이션)

  • Pang Du-Yeol;Lee Seong-Cheol;Jang Bong-Chun
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.277-278
    • /
    • 2006
  • As a development of technology, electric power steering system which uses an electric motor came to use in recent and it can solve the problems with hydraulic power steering system. In this paper, vehicle model and electric power steering system are combined to fulfill full vehicle model. By simulation effect of motor torque assist through electric power steering revealed effective, and full vehicle model are proved reasonable through comparison with real car experimental datum.

  • PDF