• 제목/요약/키워드: assist-control

검색결과 454건 처리시간 0.033초

A Control Method for Power-Assist Devices using a BLDC Motor for Manual Wheelchairs

  • Kim, Dong-Youn;Kim, Yong-Hyu;Kim, Kwang-Sik;Kim, Jang-Mok
    • Journal of Power Electronics
    • /
    • 제16권2호
    • /
    • pp.798-804
    • /
    • 2016
  • This paper proposes a new operation and control strategy for Power-Assisted Wheelchairs (PAW) using one brushless DC (BLDC) motor. The conventional electrical wheelchairs are too heavy and large for one person to move because they have two electric motor wheels. On the other hand, the proposed PAW system has a small volume and is easy to move due to the presence of a single wheel motor. Unlike the conventional electric wheelchairs, this structure for a PAW does not have a control joystick to reduce its weight and volume. To control the wheelchair without a joystick, a special control system and algorithm are needed for proper operation of the wheelchair. In the proposed PAW system uses only one sensor to detect the acceleration and direction of PAW's movement. By using this sensor, speed control can be achieved. With a speed control system, there are three kinds of operations that can be done on the speed of a PAW: the increment of PAW speed by summing external force, the decrement of PAW speed by subtracting external force, and emergency breaking by evaluating the time duration of external force. The validity of the proposed algorithm is verified through experimental results.

아급성 뇌졸중 환자에게 무릎 신전 보조기기가 균형과 보행에 미치는 효과 및 유용성 : 사례 연구 (The effect and feasibility of knee extension assist orthosis on balance and gait in subacute stroke patients : case study)

  • 심정우;양승재;윤현식
    • 대한물리치료과학회지
    • /
    • 제27권3호
    • /
    • pp.35-44
    • /
    • 2020
  • Background: This study was to confirm the effect and feasibility of knee extension assist orthosis (KEAO) on balance and gait in subacute stroke patients. Design: Case study. Methods: The subjects of the study were 4 subacute stroke patients, who had an onset period of less than 6 months. The limit of stability (LOS) and berg balance scale (BBS), timed up and go test (TUG) were used to verify the dynamic balance ability, static balance ability, and gait ability pre and post and after wearing the knee extension assist orthosis (KEAO). In addition, the satisfaction survey was to confirm the feasibility of the knee extension assist orthosis (KEAO) through the to Korean quebec user evaluation of satisfaction assistive technology 2.0 (K-QUEST 2.0). Results: After the wearing on KEAO, the distance for the limit of stability decreased by mean 541.25±240.46 mm2, and the score on the berg balance scale improved by mean 5±2.71 point, and the time for the timed up and go test deceased by mean 3.75±1.71 second. The stability and durability were found to be full score, and the control, ease, effectiveness were some high score, and the size, weight, comfort were some low score in the satisfaction and feasibility. Conclusion: The knee extension assist orthosis (KEAO) produce in this study was improved the static balance ability, dynamic balance ability and gait ability of subacute stroke patients, and the satisfaction and feasibility were high in the stability, durability and effectiveness of the user.

무릎 체중부하 촬영 보조장치 개발 (Development of Knee Weight-bearing Radiography Assist Device)

  • 김연래;윤영우
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권5호
    • /
    • pp.395-399
    • /
    • 2023
  • The knee arthritis patients are generally performed standing position radiography. However, patients with pain caused by degenerative diseases or injuries in the knee have difficulty maintaining a standing position. Therefore, this study aims to develop a knee joint standing weight bearing projection assist device to solve these problems when patients undergo knee radiography due to various diseases. The design of the knee joint weight-bearing radiography assist device is carried out with 3D design and drawing production to secure basic data, electric support and frame manufacture. A fixed device for maintaining the patient's knee standing weight-bearing projection, an electric digital height device, a digital protractor, and a safety device were designed. The arm support is made of PVC with a cushion to relieve the impact and make it easier to remove debris. The digital electric device can be moved up and down according to the patient's height, and a remote control is attached. The safety device is made to be adjustable in size by attaching metal hooks on both sides of the frame and to shield the scrotum. A digital protractor was attached to the side frame to set the desired knee angle. When a self-made assist device was used to perform a knee joint standing weight bearing projection, it helped maintain arm support and lower extremities position. In addition, the height could be adjusted using an assist device during standing projections, which helped the patient maintain the position.

전기 구동 이동형 인공호흡기의 개선 및 평가 (Improvement and Evaluation of Portable Electrical Ventilator)

  • 고성호;최낙빈;김대웅;이상훈;오용석;이계한;이성희;이태수
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.149-150
    • /
    • 1998
  • We have developed electrically driven portable ventilator and evaluated through in-vitro and in-vivo test. Ventilator is consists of DC servo motor(Kollmorgen), piston and ball screw, sensing system, power system with backup battery and micro controller. For the precise and stable volume control, the dynamic brake and the PI speed control loop is employed. The main functions are as followers; control, control+sigh, control/assist, control/assist+sigh and SIMV. The animal experiment showed stable performance when it is operated in control mode.

  • PDF

Development of walking assist system for the people with lower limb-disability

  • Kim, Seok-Hwan;Izumi, Keisuke;Koujina, Yasuhiro;Ishimatsu, Takakazu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.1495-1499
    • /
    • 2003
  • There is some equipment that helps user to exercise and to walk. But almost all equipments require some physical strength of their muscles. So we developed a system that could assist walking action of the people with lower-limb disability. The system called as walking stand adopted the balancing mechanism which assures the stable walking, and the 4 link-based mechanism that had 2 degrees of freedom on each leg. The walking stand uses four motors and has two sets of the special link-structure to simulate the human walking mechanism. With our system, even serious disabled with lower-limb disability may enjoy walking rehabilitation. And by adjusting the power, it can be used as the walking assistant mechanism instead of conventional wheelchairs. Experiments showed that our walking stand is applicable to the rehabilitation and also to the mobile device in our daily life for those people who do not have enough physical ability to walk by themselves.

  • PDF

횡풍하의 차량 외란 추정을 이용한 차선 유지 조향 보조 제어기 설계 (Design of Lane Keeping Steering Assist Controller Using Vehicle Lateral Disturbance Estimation under Cross Wind)

  • 임형호;좌은혁;이경수
    • 자동차안전학회지
    • /
    • 제12권3호
    • /
    • pp.13-19
    • /
    • 2020
  • This paper presents steering controller for unintended lane departure avoidance under crosswind using vehicle lateral disturbance estimation. Vehicles exposed to crosswind are more likely to deviate from lane, which can lead to accidents. To prevent this, a lateral disturbance estimator and steering controller for compensating disturbance have been proposed. The disturbance affecting lateral motion of the vehicle is estimated using Kalman filter, which is on the basis of the 2-DOF bicycle model and Electric Power Steering (EPS) module. A sliding mode controller is designed to avoid unintended the lane departure using the estimated disturbance. The controller is based on the 2-DOF bicycle model and the vision-based error dynamic model. A torque controller is used to provide appropriate assist torque to driver. The performance of proposed estimator and controller is evaluated via computer simulation using Matlab/Simulink.

SRAM의 읽기 및 쓰기 동작을 위한 Assist Block (Assist Block for Read and Write Operations of SRAM)

  • ;손민한;추현승
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2013년도 춘계학술발표대회
    • /
    • pp.21-23
    • /
    • 2013
  • Static Random Access Memory (SRAM) using CMOS technology has many advantages. It does not need to refresh every certain time, as a result, the speed of SRAM is faster than Dynamic Random Access Memory (DRAM). This is the reason why SRAM is widely used in almost processors and system on chips (SoC) which require high processing speed. Two basic operations of SRAM are read and write. We consider two basic factors, including the accuracy of read and write operations and the speed of these operations. In our paper, we propose the read and write assist circuits for SRAM. By adding a power control circuit in SRAM, the write operation performed successfully with low error ratio. Moreover, the value in memory cells can be read correctly using the proposed pre-charge method.

높은 파지력을 가지며 촉감을 전달할 수 있는 유연한 글러브 (A Tactilely Transparent Soft Glove with High Grasping Force)

  • 정용준;김종인;전형석;이덕원;김용재
    • 제어로봇시스템학회논문지
    • /
    • 제22권12호
    • /
    • pp.1011-1020
    • /
    • 2016
  • This paper introduces a tactilely transparent soft glove composed of soft materials and flexible structures. Although it is hard to achieve a high grasping force with conventional grip-assist gloves made from soft material, the proposed glove can exert a high force by using a novel structure. This structure has a triangular shape composed of flexible structural frames, soft fabric, and belts. It can produce grip-assist moment compliantly without harmful force or misalignment with the human fingers. The whole finger part that comes into contact with objects is made of thin and soft fabric in order to facilitate sensation transference. The proposed tactilely transparent soft glove enables the user to manipulate various objects owing to both the softness and high grasping force; it helps lifting heavy weight objects as well as permitting delicate tactile feeling on the palm and fingers. The proposed concept was applied to a two-finger grip-assist device for validation. In addition, the experimental results regarding grasping objects, fingertip force, and grasping force are presented.

하지 부분마비 장애인을 위한 착용형 로봇의 보행 보조 방법 (Gait Assist Method by Wearable Robot for Incomplete Paraplegic Patients)

  • 우한승;이장목;공경철
    • 로봇학회논문지
    • /
    • 제12권2호
    • /
    • pp.144-151
    • /
    • 2017
  • An important characteristic of people with partially impaired walking ability, such as incomplete paraplegics, is that they are able to generate voluntary motion of lower-limbs. Therefore, wearable robots for the incomplete paraplegic patients require a different assistance method compared to those of complete paraplegics. First, the wearable robot should be controlled to not resist wearer's motion. Second, it should be able to generate assistive torque accurately when needed. In this paper, a wearable robot, called EROWA, for the incomplete paraplegic patients is introduced. EROWA utilizes compact rotary series elastic actuators (cRSEAs) and a control method called the zero impedance control to reduce the mechanical resistance. An assistive torque trajectory is proposed to assist gait in this paper. The proposed method is verified by simulation and experimental studies.

EMG-based Hybrid Assistive Leg for Walking Aid using Feedforward Controller

  • Kawamoto, Hiroaki;Sankai, Yoshiyuki
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.32.2-32
    • /
    • 2001
  • We have developed the power assistive leg called HAL (Hybrid Assistive Leg) which provide the walking aid for walking disorder persons or aged persons without nursing person. We developed HAL-3 by considering some problems of HAL-1,2 which had developed previously. The mechanism of HAL-3 actuator could be simplified and sophisticated by using the harmonic drive. As the control signal of HAL-3 EMG signal was used. We proposed a calibration method to identify parameters which relates the EMG to joint torque by using HAL-3. We could obtain suitable torque estimated by EMG and realize power assist in walking according to the intention of the operator To the remove discomfort for quick motion power assist, the feedforward controller was installed at the beginning of motion ...

  • PDF