• Title/Summary/Keyword: artificial saliva

Search Result 156, Processing Time 0.023 seconds

THE REMINERALIZING EFFECTS OF EARLY ENAMEL CAR10US LESION BY SUPERSATURATED BUFFER SOLUTION UNDER PH CYCLING MODEL (pH 순환 모델에서 과포화 용액의 초기 우식 법랑질에 대한 재광화 효과)

  • 김소라;홍석진;노병덕;이찬영;금기연
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.4
    • /
    • pp.341-349
    • /
    • 2001
  • Dental caries is the most common oral disease. There are many factors contributing to its development, but complete understanding and prevention are not fully known. However, it is possible to remineralize the early enamel curious lesion by fluoride containing remineralization solution. Recently the pH-cycling model has been used to examine the effect of fluoride solution on remineralization of artificial caries in vitro as it can closely simulate the conditions encountered in vivo within a carefully controlled environment. The aim of this study was to evaluate the remineralizing effects of supersaturated buffer solutions under pH-cycling model. The specimen with 3mm-diameter was made using mature bovine incisors which has no caries and has sound enamel surface. Early curious lesions were produced by suspending each specimens into demineralization solution at pH 5.0 for 33 hours and the specimen whose surface hardness value ranged from 25 to 45 VHN were used. The pH cycling treatment regimen consisted of 5 min soaks of three treatment solutions four times per days for 15 days and the continuous cycling of demineralization and remineralization were carried out for 15 days. Following the pH-cycling treatment regimen, the specimens' surface microhardness were measured by the Vickers hardness test (VHN) and analyzed by ANOVA and Duncan's multiple-range test. 1. The surface microhardness value of supersaturated solution, Senstime, and Gagline groups were increased after pH cycling, and that of supersaturated solution was significantly Increased compared to saline group(P<0.05). 2. The surface remineralization effect of fluoride containing solutions was accelerated by saliva under pH-cycling mode 3. The pH cycling model was considered appropriate to mimic the intra-oral pH changes when evaluating demineralization and remineralization in vitro. Under the results of above study, salivary remineralization effect can be improved by fluoride containing remineralization solution. The pH-cycling model was considered appropriate to mimic the intra-oral pH changes when evaluating demineralization and remineralization in vitro.

  • PDF

Effect of abutment angulation in the retention and durability of three overdenture attachment systems: An in vitro study

  • Aroso, Carlos;Silva, Antonio Sergio;Ustrell, Raul;Mendes, Jose Manuel;Braga, Ana Cristina;Berastegui, Esther;Escuin, Tomas
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.1
    • /
    • pp.21-29
    • /
    • 2016
  • This in vitro study investigated and compared the durability and retention of three types of attachments. MATERIALS AND METHODS. Three commercially available attachments were investigated: $Clix^{(R)}$, Dalbo-$Plus^{(R)}$ and $Locator^{(R)}$. In total, 72 samples of these attachments were placed in the acrylic resin forms and subjected to mechanical testing (5400 cycles of insertion and removal) over the respective ball or Locator abutments immersed in artificial saliva at pH 7 and $37^{\circ}C$. The abutments were placed at angulations of $0^{\circ}$, $10^{\circ}$ and $20^{\circ}$. The retention force was recorded at the beginning and after 540, 1080, 2160, 3240, 4320 and 5400 insertion-removal cycles. RESULTS. The results revealed that there were significant differences in the average values of the insertion/removal force due to angulation ($F_{(2.48)}=343619$, P<.05) and the type of attachment ($F_{(7.48)}=23.220$, P<.05). CONCLUSION. Greater angulation of the abutments was found to influence the retention capacity of the attachments, and the fatigue test simulating 5 years of denture insertion and removal did not produce wear in the metal abutments.

The effect of repeated porcelain firings on corrosion resistance of different dental alloys

  • Tuncdemir, Ali Riza;Karahan, Ismail;Polat, Serdar;Malkoc, Meral Arslan;Dalkiz, Mehmet
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.1
    • /
    • pp.44-50
    • /
    • 2013
  • PURPOSE. The aim of this study was to evaluate the effects of repeated porcelain firing process on the corrosion rates of the dental alloys. MATERIALS AND METHODS. Cr-Co, Cr-Ni and Pd-Ag alloys were used for this study. Each metal supported porcelain consisted of 30 specimens of 10 for 7, 9 and 11 firing each. Disc-shaped specimens 10 mm diameter and 3 mm thickness were formed by melting alloys with a propane-oxygen flame and casted with a centrifuge casting machine and then with the porcelain veneer fired onto the metal alloys. Corrosion tests were performed in quintuplicate for each alloy (after repeated porcelain firing) in Fusayama artificial saliva solution (pH = 5) in a low thermal-expansion borosilicate glass cell. Tamhane and Sheffe test was used to compare corrosion differences in the results after repeated firings and among 7, 9 and 11 firing for each alloy. The probability level for statistical significance was set at ${\alpha}$=0.05. RESULTS. The corrosion resistance was higher (30 mV), in case of 7 times firing (Commercial). On the other hand, it was lower in case of 11 times firing (5 mV) (P<.05). Conclusion. Repeated firings decreased corrosion resistance of Pd-Ag, Cr-Co and Cr-Ni alloys. The Pd-Ag alloy exhibited little corrosion in in vitro tests. The Cr-Ni alloy exhibited higher corrosion resistance than Cr-Co alloys in in vitro tests.

Wear Behavior of Alumina-glass Composites Prepared by Melt Infiltration (용융침투법으로 제조한 알루미나-유리 복합체의 내마모 특성)

  • 이세종
    • Journal of the Korean Ceramic Society
    • /
    • v.40 no.9
    • /
    • pp.881-885
    • /
    • 2003
  • Wear and friction properties of the alumina-glass dental ceramics were evaluated in exact in vitro environment (artificial saliva at 37$^{\circ}C$), using a ball-on-disc apparatus, at contact loads from 49 N to 196 N and with the disc rotating at 120 rpm up to 10$^{6}$ cycles to investigate the wear behavior. As the load increased from 49 N to 196 N, the friction coefficient of 0.025 was maintained, however, the volumetric wear rate rose from 2.18 ${\times}$10$^{-9}$TEX>$mm^{3}$/Nㆍm to 2.35 ${\times}$10$^{-6}$TEX>$mm^{3}$/Nㆍm. Experimental results indicated that the wear behavior of the alumina-glass composites with a sliding distance of 4.4 km was a typical adhesive wear, which was applicable for orthodontia ceramic brackets.

Tooth whitening maintenance efficacy of dentifrices containing several active ingredients in vitro and in vivo (유효성분들을 배합한 치약제의 실험실적 및 임상적 치아미백유지 효과)

  • Ahn, Jae-Hyun;Kim, Ji-Hye;Kim, Jong-Hoon
    • Journal of Korean society of Dental Hygiene
    • /
    • v.15 no.2
    • /
    • pp.325-332
    • /
    • 2015
  • Objectives: The purpose of this study was to investigate tooth whitening maintenance efficacy of several dentifrices containing effective ingredients for tooth whitening. Methods: Hydroxyapatite specimens(HAPs) staining was done by using modified Stookey's methods. HAPs were treated with 2.9% hydrogen peroxide containing strip for whitening, and were shaken with several dentifrice slurry(dentifrice 1 : artificial saliva 2) for 30 minutes. The HAPs were finally dipped in staining solution for an hour. Shaking and dipping were repeated 4 times and lightness values were measured by colorimeter at each step. In clinical test, test 4 dentifrice and control dentifrice were evaluated by 21 subjects for 2 months after receiving institutional review board(IRB) approval. Organoleptic(vita shade guide) and instrumental(SHADEEYE-NCC) evaluation were performed for whiteness change of teeth. Statistical analysis was performed using repeated measures ANOVA, Tukey's post hoc test and ${\chi}^2$-test(p<0.05). Results: All dentifrices showed statistical significance in comparison with control dentifrice containing sodium fluoride and test 4 dentifrice containing sodium pyrophosphate, sodium metaphosphate, candelilla wax, and sodium fluoride showed statistical significance in comparison with other dentifrices by inhibiting staining in vitro(p<0.05). In clinical test, test 4 dentifrice showed better effects than control dentifrice in organoleptic and instrumental evaluation in tooth whitening maintenance efficacy(p<0.05). The awareness toward tooth whitening maintenance efficacy for 2 months use showed that test 4 dentifrice was much better than control dentifrice, but did not show statistically significant(p>0.05). Conclusions: Dentifrice containing sodium pyrophosphate, sodium metaphosphate, candelilla wax and sodium fluoride was more effective in keeping teeth white.

Impact of Ecklonia stolonifera extract on in vitro ruminal fermentation characteristics, methanogenesis, and microbial populations

  • Lee, Shin Ja;Jeong, Jin Suk;Shin, Nyeon Hak;Lee, Su Kyoung;Kim, Hyun Sang;Eom, Jun Sik;Lee, Sung Sill
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.32 no.12
    • /
    • pp.1864-1872
    • /
    • 2019
  • Objective: This study was conducted to evaluate the effects of Ecklonia stolonifera (E. stolonifera) extract addition on in vitro ruminal fermentation characteristics, methanogenesis and microbial populations. Methods: One cannulated Holstein cow ($450{\pm}30kg$) consuming timothy hay and a commercial concentrate (60:40, w/w) twice daily (09:00 and 17:00) at 2% of body weight with free access to water and mineral block were used as rumen fluid donors. In vitro fermentation experiment, with timothy hay as substrate, was conducted for up to 72 h, with E. stolonifera extract added to achieve final concentration 1%, 3%, and 5% on timothy hay basis. Results: Administration of E. stolonifera extract to a ruminant fluid-artificial saliva mixture in vitro increased the total gas production. Unexpectedly, E. stolonifera extracts appeared to increase both methane emissions and hydrogen production, which is contrasts with previous observations with brown algae extracts used under in vitro fermentation conditions. Interestingly, real-time polymerase chain reaction indicated that as compared with the untreated control the ciliate-associated methanogen and Fibrobacter succinogenes populations decreased, whereas the Ruminococcus flavefaciens population increased as a result of E. stolonifera extract supplementation. Conclusion: E. stolonifera showed no detrimental effect on rumen fermentation characteristics and microbial population. Through these results E. stolonifera has potential as a viable feed supplement to ruminants.

Evaluation of the Potential of Commercial Vitamin Drinks to Induce Tooth Erosion

  • Kim, Han-Na;Yoon, Tae-Lim;Min, Ji-Hyun
    • Journal of dental hygiene science
    • /
    • v.19 no.3
    • /
    • pp.154-161
    • /
    • 2019
  • Background: The market for vitamin drinks is expanding both in Korea and worldwide. However, it was difficult to find studies regarding the possibility of tooth erosion induction due to vitamin drinks. The purpose of the present in vitro study was to evaluate the effect of tooth erosion caused by a few commercial vitamin beverages on bovine teeth enamel in terms of erosion depth and fluorescence loss. Methods: Three experimental groups (vitamin drinks), a positive control group (Coca-Cola), and a negative control group (mineral water) were established. Each group consisted of 5 specimens obtained from sound bovine teeth. The pH and titratable acidity of beverages were measured. Specimens were immersed in the beverages and artificial saliva for 6 and 18 hours, respectively. This cycle was repeated for 5 days. The depth of the tooth loss caused by tooth erosion (erosion depth) and maximum loss of fluorescence (Max ${\Delta}F$) were measured using the microscope and quantified light-induced fluorescence-digital, respectively. For the statistical analysis, the Kruskal-Wallis test and ANOVA were used to compare the erosion depth and Max ${\Delta}F$ of the enamel surfaces. In addition, Spearman correlations were estimated. Results: The pH of the three vitamin beverages ranged from 2.65 to 3.01, which is similar to that of the positive control group. All beverages, except mineral water, had sugar and acidic ingredients. Vitamin drinks and the positive control, Coca-Cola, caused tooth erosion lesions, and showed significant differences in erosion depth compared to mineral water (p<0.05). The vitamin beverages with low pH were associated with high erosion depth and Max ${\Delta}F$. Conclusion: Vitamin drinks have the potential to cause tooth erosion.

Microshear bond strength of dual-cure resin cement in zirconia after different cleaning techniques: an in vitro study

  • Atoche-Socola, Katherine Joselyn;Arriola-Guillen, Luis Ernesto;Lopez-Flores, Ana Isabel;Garcia, Isadora Martini;Huertas-Mogollon, Gustavo;Collares, Fabricio Mezzomo;Leitune, Vicente Castelo Branco
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.4
    • /
    • pp.237-245
    • /
    • 2021
  • PURPOSE. This study aimed to compare the microshear bond strength (µSBS) of dual-cure resin cement in CAD-CAM zirconia after different cleaning techniques. MATERIALS AND METHODS. Fifty discs of zirconia-based ceramic from Ivoclar Vivadent were embedded in acrylic resin. The discs were divided into five groups according to the cleaning methods used: Group 1: drying with spraying + sandblasting with Al2O3; Group 2: washed with water and dried with spraying + sandblasting with Al2O3;Group 3: washed with distilled water and dried with spraying + sandblasting with Al2O3 + zirconium oxide (Ivoclean); Group 4: washed with distilled water and dried with spraying + sandblasting with Al2O3 + potassium hydroxide (Zirclean); and Group 5: washed with distilled water and dried with spraying + sandblasting with Al2O3 + 1% NaClO. All of the groups were contaminated with artificial saliva for 1 minute and then cleaned. Statistical analyses were performed using ANOVA and Tukey's tests. RESULTS. There were statistically significant differences among all groups for µSBS (P < .05). The group treated with zirconium oxide (Group 3) showed the highest µSBS (18.75 ± 0.23 MPa). CONCLUSION. When applied to zirconia, the cleaning methods affected the bonding with resin cement differently.

Effect of three common hot beverages on the force decay of orthodontic elastomeric chain within a 28-day period: An in vitro study

  • Maziar Nobahari;Fatemeh Safari;Allahyar Geramy;Tabassom Hooshmand;Mohammad Javad Kharazifard;Sepideh Arab
    • The korean journal of orthodontics
    • /
    • v.54 no.3
    • /
    • pp.153-159
    • /
    • 2024
  • Objective: This study aimed to assess the effects of commonly consumed hot drinks on the force decay of orthodontic elastomeric chains. Methods: This in vitro experimental study evaluated 375 pieces of elastomeric chains with six rings placed on a jig. Four rings were stretched by 23.5 mm corresponding to the approximate distance between the canine and the second premolar. Fifteen pieces served as reference samples at time zero, and 360 pieces were randomized into four groups: control, hot water, hot tea, and hot coffee. Each group was further divided into six subgroups (n = 15) according to the different exposure periods. The specimens in the experimental groups were exposed to the respective solutions at 65.5℃ four times per day for 90 seconds at 5-second intervals. The control group was exposed to artificial saliva at 37℃. The force decay of the samples was measured at 1, 2, 7, 14, 21, and 28 days using a universal testing machine. Data were analyzed using repeated-measures analysis of variance. Results: Maximum force decay occurred on day 1 in all groups. The minimum force was recorded in the control group, followed by the tea, coffee, and hot water groups on day 1. At the other time points, the minimum force was observed in the tea group, followed by the control, coffee, and hot water groups. Conclusions: Patients can consume hot drinks without concern about any adverse effect on force decay of the orthodontic elastomeric chains.

THE EFFECT OF LIGATION METHOD ON THE FRICTIONAL FORGE BETWEEN ORTHODONTIC BRACKET AND ARCHWIRE (결찰양식이 교정용 브라켓과 교정선 사이의 마찰력에 미치는 영향)

  • Shin, Hyun-Jeong;Kwon, Oh-Won;Kim, Kyo-Han
    • The korean journal of orthodontics
    • /
    • v.28 no.5 s.70
    • /
    • pp.813-823
    • /
    • 1998
  • The frictional force has been considered as an harmful factor in an active unit where tooth movement occurs, but as an advantageous factor in anchor unit that resist tooth movement. That is, efficient tooth movement is planned by using ligation methods that have low levels of bracket-wire frictional force and the anchorage control can be achieved by using ligation methods that have high levels of bracket-wire frictional force that result in binding of the bracket accompanied by little or no tooth movement. The purpose of this study was to evaluate the frictional force generated between bracket and wire in accordance with the methods of ligation, the material of ligation and the passage of time under artificial saliva. Tested were 0.017x0.022 inch stainless steel wires in standard edgewise twin brackets for upper central incisors in a 0.018-inch slot. The wires were ligated into the brackets with elastomeric modules and stainless steel ligatures. Whole tie, half tie, twisting tie and double overlay tie were done with elastomeric modules. With 0.009-inch stainless steel ligature whole tie and half tie were done by needle holder and whole tie by ligature tying plier. With 0.012-inch stainless steel ligature whole ties were done by needle holder. Whole tie groups of elastomeric module were kept in artificial saliva bath at $37^{\circ}C$ for 28 days. The frictional force was recorded by means of an Instron universial testing instrument (4202 INSTRON, Instron Co., U.S.A.) at initial, 7, 14, 21, and 28 days. The results for ligated samples in a simulated oral environment revealed the fellowing : ${\cdot}$In elastomeric module whole tie, 28 days group was significantly greater mean static frictional force than any other group but there were no significant differences among any other group (p>0.05). ${\cdot}$Elastomeric module twisting ties were significantly greater mean static frictional forces than any other ligation method but there were no significant differences between twisting tie and double overlay tie (p>0.05). Twisting tie, double overlay tie, whole tie, half tie showed differences in decreasing order. ${\cdot}$Stainless steel half tie produced lower mean static frictional force than whole tie, ligation by ligature tying plier produced greater mean static frictional force than by needle holder and ligation with 0.012-inch stainless steel ligature produced greater mean static frictional force than with 0.009-inch stainless steel ligature (p<0.05). ${\cdot}$There were no significant differences between the mean static frictional forces of elastomeric whole tie and stainless steel whole tie (p>0.05).

  • PDF