• Title/Summary/Keyword: artificial crack

Search Result 191, Processing Time 0.024 seconds

Experimental and numerical investigation of reinforced concrete beams containing vertical openings

  • Parol, Jafarali;Ben-Nakhi, Ammar;Al-Sanad, Shaikha;Al-Qazweeni, Jamal;Al-Duaij, Hamad J.;Kamal, Hasan
    • Structural Engineering and Mechanics
    • /
    • v.72 no.3
    • /
    • pp.383-393
    • /
    • 2019
  • Horizontal openings in reinforced concrete (RC) beams are quite often used to accommodate service pipelines. Several research papers are available in the literature describing their effect. RC beams with vertical openings are commonly used to accommodate service lines in residential buildings in Kuwait. However, there are lack of design guidelines and best practices reported in the literature for RC beams with vertical openings, whereas the detailed guidelines are available for beams with horizontal openings. In the present paper, laboratory experiments are conducted on nine RC beams with and without vertical openings. Parametric study has been carried out using nonlinear finite element analysis (FEA) with changes in the diameter of the opening, various positions of the opening along the length and width of the beam, edge distance, etc. 50 finite element simulations were conducted. The FEA results are verified using the results from the laboratory experiments. The study showed that the load carrying capacity of the beam is reduced by 20% for the RC beam with vertical openings placed near the center of the beam compared to a solid beam without an opening. Significant reduction in load carrying capacity is observed for beams with an opening near the support (${\approx}15%$). The overall stiffness of the beam, crack pattern and failure modes were not affected due to the presence of the vertical opening. Furthermore, an artificial neural network (ANN) analysis is carried out using the FEA generated data. The results and observations from the ANN and FEA are in good agreement with experimental results.

Estimation of Concrete Cover Failure Time Considering the Corrosion Rate in Reinforced Concrete Structures (철근 부식속도 예측식을 이용한 철근 피복 파괴 시간 추정)

  • Jang, Bong-Seok
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.2 s.92
    • /
    • pp.233-238
    • /
    • 2006
  • In lifetime estimation, the FEM analysis method is proposed for predicting corrosion failure time of concrete structures exposed to sea-water. This study shows that the corrosion rate of rebar in artificial pore solution can be transferred to the corrosion rate of rebar in concrete using the relationship between pore volume and concrete volume by Jennings' model. And this study considered the pitting corrosion effects of reinforcement bar on corrosion failure analysis, rebar size to cover depth and nonlinear crack analysis. These analysis results have good accordance with the experimental results of Williamson's work. This methodology can be applied to lifetime prediction procedure of reinforced concrete structures and also gives more reasonable results of concrete cover failure time estimation of reinforced concrete structures exposed to sea-water.

THE INFLUENCE OF FLUORIDE ON REMINERALIZATION OF ARTIFICIAL DENTAL CARIES (인공치아우식의 재광화에 미치는 불소의 영향)

  • Han, Won-Seop;Kum, Kee-Yeon;Lee, Chan-Young
    • Restorative Dentistry and Endodontics
    • /
    • v.21 no.1
    • /
    • pp.161-173
    • /
    • 1996
  • The cariostatic effect of fluoride had been established by many epidemiologic and experimental studies. But, there are still different views on the mechnism of cariostasis and remineralization, especially about the proper fluoride concentration. The purpose of this study is to ascertain the remineralization of caries lesion and influence of fluoride concentration which affect remineralization by a study based on dynamic mechanism. The subjects, sound permanent teeth without demineralization or crack, were immersed in lactic acid buffered demineralization solution for 4 days. Dental caries with surface zone and subsurface lesion were artificially produced. All specimens were immersed in lactic acid buffered remineralization solution which had fluoride concentrations of 1 ppm, 2 ppm, 3 ppm for 10days. Final conclusions were obtained by observing the specimens for every 10 days under polarized microscopy. 1. Remineralization of caries lesion as well as demineralization of enamel were produced by changing the degree of saturation of lactic acid buffer solution. 2. Remineralization of caries lesion was facillitated by fluoride ion in lactic acid buffer solution. but, remineralization of the entire caries lesion was not increased as fluoride ion concentration increased.

  • PDF

A Study on the Digital Signal Processing for the Pattern fiecognition of Weld Flaws (용접결함의 패턴인식을 위한 디지털 신호처리에 관한 연구)

  • 김재열;송찬일;김병현
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.393-396
    • /
    • 1995
  • In this syudy, the researches classifying the artificial and natural flaws in welding parts are performed using the smart pattern recognition technology. For this purpose the smart signal pattern recognition package including the user defined function was developed and the total procedure including the digital signal processing,feature extraction , feature selection and classifier selection is treated by bulk. Specially it is composed with and discussed using the statistical classifier such as the linear disciminant function classifier, the empirical Bayesian classifier. Also, the smart pattern recognition technology is applied to classification problem of natural flaw(i.e multiple classification problem-crack,lack of penetration,lack of fusion,porosity,and slag inclusion, the planar and volumetric flaw classification problem). According to this results, if appropriately learned the neural network classifier is better than ststistical classifier in the classification problem of natural flaw. And it is possible to acquire the recognition rate of 80% above through it is different a little according to domain extracting the feature and the classifier.

  • PDF

The Evaluation of Property of Colored Contact Lenses (칼라콘택트렌즈의 물성적 특성 평가)

  • Park, Hyun-Ju
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.2
    • /
    • pp.119-126
    • /
    • 2005
  • The purpose of this study was analyzed to compare on the physical characters of two companies of color contact lenses. Artificial tear solution was used for measuring the rate of protein deposits and wettability. The surface roughness of lenses was measured by SEM(scanning electron microscope, Japan) and AFM(atomic force microscope, MultimodeTM, USA). As a results, The color contact lenses was not different from general soft contact lenses in a respect of other properties. However, the colored contact lenses showed a severe crack on the surface under SEM observation. There was no irregularity on the surface of the colored contact lenses in AFM photograph. The dyes were deposited in inside of lenses by microscope observation.

  • PDF

Fatigue wear of polyamides with surface defects under different loading conditions

  • Abdelbary, Ahmed;Nasr, Mohamed N.A.
    • Advances in materials Research
    • /
    • v.5 no.3
    • /
    • pp.193-203
    • /
    • 2016
  • Compared to metal-to-metal tribology, polymer tribology presents further complexity as it is more prone to be influenced by operating conditions. Over the past two decades, progress in the field of wear of polymers has led to the establishment of more refined wear mechanisms. The current paper establishes the link between different load parameters and the wear rate of polymers, based on experimental investigations. A pin-on-plate reciprocating tribometer was used to examine the wear behaviour of polyamide sliding against a steel counterface, under constant and fluctuating loads, in dry conditions. In addition, the influence of controlled imperfections in the polymer surface upon its wear rate were examined, under cyclic and steady loading, in order to better understand surface fatigue wear of polymers. The imposed imperfections consisted of vertical artificial deep crack (slit) perpendicular or parallel to the direction of sliding. The study concludes with the followings findings; in general, wear of polymers shows a significant tendency to the type of applied load. Under cyclic loads, polymers show an increase in wear rate compared to those tested under static loads. Such increase was found to increase with the increase in cyclic load frequency. It is also demonstrated that surface cracks results in higher wear rates, particularly under cyclic loads.

Case Study on Failure of Rock Slope Caused by Filling Material of Clay (점토 충전물에 의한 암반사면 파괴사례 연구)

  • Kim, Yong-Jun;Lee, Young-Huy;Kim, Sun-Ki;Kim, Ju-Hwa
    • Tunnel and Underground Space
    • /
    • v.16 no.5 s.64
    • /
    • pp.368-376
    • /
    • 2006
  • After heavy rainfall, It was occurred massive plane failure along bedding plane of shale in the center of rock slope. It was observed filling material and trace of underground water leakage around of the slope. We tried to find the cause for slope failure, and the result of examination showed that primary factors of the failure were low shear strength of clay filling material and water pressure formed within tension crack existed in the top of the slope. In this research, in order to examine the features of shear strength of filled rock joint, shear test of filled rock joint was conducted using of artificial filling material such as sand and clay..Also we made an investigation into the characteristics of shear strength with different thickness of filling materials.

A Development of Automatic Defect Detection Program for Small Solid Rocket Motor (소형 로켓 모타의 결함 자동 판독 프로그램 개발)

  • Lim, Soo-Yong;Son, Young-Il;Kim, Dong-Ryun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.1
    • /
    • pp.31-35
    • /
    • 2010
  • This paper presents the development of automatic defect detection program using 3D computed tomography image of small solid rocker motor. We applied the neighbor pixel comparison algorithm with beam hardening correction for the recognition of defect. We made the artificial defect specimen in order to decide a standard CT value of defect. The program was tested with 150 small solid rocket motors and it could detect the disbond, crack, foreign material and void. The program showed more reliable and faster results than human inspector's interpretation.

Case Study on Failure of Rock Slope Caused by Filling Material Formed along the Bedding Plane of Sedimentary Rock (퇴적암의 층리면을 따라 형성된 충전물에 의한 암반사면 붕괴사례)

  • Kim, Yong-Jun;Lee, Young-Huy;Lee, Jong-Sung;Kim, Wu-Jun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.10a
    • /
    • pp.256-267
    • /
    • 2006
  • After heavy rainfall, It was occurred massive plane failure along bedding plane of shale in the center of rock slope. It was observed filling material and trace of underground water leakage around of the slope. We tried to find the cause for slope failure, and the result of examination showed that primary factors of the failure were low shear strength of clay filling material and water pressure farmed within tension crack existed in the top of the slope. In this research, in order to examine the features of shear strength of filled rock joint, shear test of filled rock joint was conducted using of artificial filling material such as sand and clay. Also we made an investigation into the characteristics of shear strength with different thickness of filling materials.

  • PDF

A Study on Hardened Properties and Durability of Concrete according to Unit-Water Content (배합수량 변동에 따른 콘크리트의 경화성상 및 내구성에 관한 연구)

  • Koo, Kyung-Mo;Lim, Chang-Hyuck;Lee, Eui-Bae;Kim, Young-Sun;Kim, Young-Duck;Kim, Gyu-Yong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.05b
    • /
    • pp.45-48
    • /
    • 2009
  • The performance of concrete mainly depend upon its water-cement ratio. If water percentage is excess in concrete, it may cause the degradation of performance. Because of these reasons, the change of water content is managed by using various evaluation method of unit water content. And criterion for the change of water content is regulated and used. However the criterion is set only considering production error and measurement error but criterion does not consider performance degradation of concrete. Therefore this study tries to investigate degradation of performance while adding extra water by artificial manipulation or management error in concrete, The contents of extra water for tests are set as 0, 20, 40, 60kg/m3, to examine the performance degradation of concrete, strength, shrinkage, cracks, carbonation are tested This study conclude that, when extra water content is excess than 20kg/m3 in concrete, then performance level of concrete declined rapidly. 80 it is very important to maintain quality of concrete for its better performance.

  • PDF