• 제목/요약/키워드: artificial blood vessel

검색결과 21건 처리시간 0.029초

In vitro and in vivo Application of PLGA Nanofiber for Artificial Blood Vessel

  • Kim, Mi-Jin;Kim, Ji-Heung;Yi, Gi-Jong;Lim, Sang-Hyun;Hong, You-Sun;Chung, Dong-June
    • Macromolecular Research
    • /
    • 제16권4호
    • /
    • pp.345-352
    • /
    • 2008
  • Poly(lactic-co-glycolic acid) (PLGA) tubes (5 mm in diameter) were fabricated using an electro spinning method and used as a scaffold for artificial blood vessels through the hybridization of smooth muscle cells (SMCs) and endothelial cells (ECs) differentiated from canine bone marrow under previously reported conditions. The potential clinical applications of these artificial blood vessels were investigated using a canine model. From the results, the tubular-type PLGA scaffolds for artificial blood vessels showed good mechanical strength, and the dual-layered blood vessels showed acceptable hybridization behavior with ECs and SMCs. The artificial blood vessels were implanted and substituted for an artery in an adult dog over a 3-week period. The hybridized blood vessels showed neointimal formation with good patency. However, the control vessel (unhybridized vessel) was occluded during the early stages of implantation. These results suggest a shortcut for the development of small diameter, tubular-type, nanofiber blood vessels using a biodegradable material (PLGA).

Implantation of Small Artery Vessel from Blends PCL/PU with and without Anti-thrombus

  • Hiep, Nguyen Thi;Lee, Seong-Jin;Min, Young-Ki;Yang, Hun-Mo;Song, Ho-Yeon;Lee, Byong-Taek
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2010년도 춘계학술발표대회
    • /
    • pp.45.1-45.1
    • /
    • 2010
  • In this experiment, artificial blood vessel was fabricated from electro-spun PU/PCL. To assist with endothelial growth, PU/PCL surface was coated with the RGD peptide. To prevent a clot of blood, anti-thrombus agent was loaded to the fibrous mat and values were reflected through FT-IR data. In vitro study, SEM and MTT data showed that the component was of excellent biocompatibility and cell proliferation. In in vivo study, the artificial blood vessel was implanted in a dog's artery. The results of the CT scan, ultrasound and H&E staining showed that artificial blood vessel was excellent for artery replacement applications.

  • PDF

μ-PIV기법을 이용한 동정맥루 모사혈관에서의 모사 혈액의 점도특성에 따른 혈류역학적 분석 (Hemodynamical analysis by viscosity characteristics of artificial blood for μ-PIV experiment of Radio-cephalic arteriovenous fistula(RC-AVF))

  • 송륜근;이진기
    • 한국가시화정보학회지
    • /
    • 제14권1호
    • /
    • pp.33-39
    • /
    • 2016
  • Radio-cephalic arteriovenous fistula(RC-AVF) is the most recommended operation of achieving access for hemodialysis. However, it has high rates of early failure depending on the many haemodynamic conditions. To increase RC-AVF patency rate, many researches were performed by in-vitro experiment via artificial vessel and blood analogue fluid, and there were conflicting opinions about whether the non-Newtonian properties of blood have an influence on the flow in large arteries. To investigate the influence of viscoelasticity of blood within the RC-AVF, we fabricated three dimensional artificial RC-AVF and two kinds of blood analogue fluid. The velocity field of two fluids within the vessel were measured by micro-particle velocimetry(m-PIV) and compared with each other. The velocity profiles of both fluids for systolic phase were matched well while those for diastolic phase did not correspond. Therefore, it is desired to use non-newtonian fluid for in-vitro experiment of RC-AVF.

합성제어기를 이용한 혈압 시뮬레이터의 구현 (Blood pressure simulator using hybrid controller)

  • 김철한;사공건;남기곤;전계록
    • 센서학회지
    • /
    • 제16권1호
    • /
    • pp.44-51
    • /
    • 2007
  • A hybridized simulator for generating blood pressure waveform is proposed to study the remedy and/or evaluation of the conventional sphygmomanometer utilizing the oscillometric method which is widely applied. The blood pressure of a flowing fluid was controlled for the blood vessel's condition caused by a rhythmical and periodical contraction/relaxation because of the special excitatory and conductive system of the heart. In this study, a hybridized controller composed of the PI feedback controller and the feedforward controller. The inverse dynamics function is proposed to operating the control valve while the pressure is applied in an oil pressure tank. The proposed hybrid simulator reproducing the blood pressure waveform in an artificial blood vessel has kept the control performance consistent over all range. Based on these results, the proposed simulators could be applied to the development and compensation of the non invasive sphygmomanometer type as well as to study the characteristics of the blood pressure and blood vessel.

심혈관계 시뮬레이터의 연구동향 (Review of Simulators for Cardiovascular System)

  • 신상훈;이주연
    • 대한한의진단학회지
    • /
    • 제15권1호
    • /
    • pp.55-66
    • /
    • 2011
  • Objectives: The purpose of this study is to review the simulator for cardiovascular system. Methods & Results: Simulators were classified according to the structure and function of cardiovascular system. Heart and blood vessel were selected as the represent of structure. Blood pressure and blood flow were chose as the functional index. With the view points of four keywords, four kinds of simulators were selected: artificial heart, pressure simulator, flow simulator, and pulse simulator. Conclusions: This paper discussed the state of the art of research and development of the selected four kinds of simulators.

Blue-tooth based blood sugar control application

  • Kelly, Raymond
    • 한국인공지능학회지
    • /
    • 제3권1호
    • /
    • pp.4-6
    • /
    • 2015
  • These days, citizens have made change of food life to take Western style food and to suffer from diabetes because of excessive nutrition taking, less exercise, stress and other environmental factors. They may suffer from diabetes because of genetic defect, surgery of pancreas, disinfection and medicine and others. One of ten Koreans may have symptom of diabetes to be popular. The diabetes that is a kind of metabolic disease has high blood sugar at disorder of hyper insulinism and/or defect of insulin action. Long time high blood sugar may produce chronic disease of kidney, eyes, nerve, heart and blood vessel and others. The purpose of health care of diabetes patient was to reach target blood sugar by diet, physical exercise and medicine and to prevent and delay complication. Diabetes patient shall control blood sugar to keep healthy. The blood sugar control requires time and effort, and all of the patients are difficult to make effort and to spend time. You can control blood sugar by the application. The application allows patients to control blood sugar and to save time and efforts and to make small sized input and automation of remaining area. The service was limited to blood sugar graph, and user carries smart phone to conduct test and to have difficulty. Further study needs to solve the problems and to investigate blood sugar testing not carrying smart phone and to make application of easy control of blood sugar.

Turn signal lamp jacket to prevent accident of bicycles

  • Saxena, Tarika
    • 한국인공지능학회지
    • /
    • 제4권1호
    • /
    • pp.4-7
    • /
    • 2016
  • These days, citizens have made change of food life to take Western style food and to suffer from diabetes because of excessive nutrition taking, less exercise, stress and other environmental factors. They may suffer from diabetes because of genetic defect, surgery of pancreas, disinfection and medicine and others. One of ten Koreans may have symptom of diabetes to be popular. The diabetes that is a kind of metabolic disease has high blood sugar at disorder of hyper insulinism and/or defect of insulin action. Long time high blood sugar may produce chronic disease of kidney, eyes, nerve, heart and blood vessel and others. The purpose of health care of diabetes patient was to reach target blood sugar by diet, physical exercise and medicine and to prevent and delay complication. Diabetes patient shall control blood sugar to keep healthy. The blood sugar control requires time and effort, and all of the patients are difficult to make effort and to spend time. You can control blood sugar by the application. The application allows patients to control blood sugar and to save time and efforts and to make small sized input and automation of remaining area. The service was limited to blood sugar graph, and user carries smart phone to conduct test and to have difficulty. Further study needs to solve the problems and to investigate blood sugar testing not carrying smart phone and to make application of easy control of blood sugar.

상장간막동맥류의 수술적 치료 -1례 보고- (Superior Mesentic Artery Aneurysm -A Case Report-)

  • 신재승
    • Journal of Chest Surgery
    • /
    • 제27권11호
    • /
    • pp.948-952
    • /
    • 1994
  • Superior mesenteric artery aneurysm is the third most common lesion and comprises approximately 5.5 % of all visceral artery aneurysms. The first successful repair was performed by DeBakey and Cooley in 1949. Since then, more than 100 cases have been reported. Fifty to sixty percent of these aneurysms are mycotic in origin. Other less frequent causes include arteriosclerosis, trauma, and medial degeneration. The operations are bypass with autologous tissue or with artificial vascular graft and aneurysmorrhaphy. We have experienced a case of superior mesenteric artery aneurysm which had undergone aneurysmectomy and artificial graft interposition. This is the first domestic case which was successful surgical repaired.

  • PDF

연잎 모사 구조로의 초소수성 표면 처리와 의료분야의 적용에 관한 연구 (Fabrication and Medical Applications of Lotus-leaf-like Structured Superhydrophobic Surfaces)

  • 임진익;김승일;정영미;김수현
    • 폴리머
    • /
    • 제37권4호
    • /
    • pp.411-419
    • /
    • 2013
  • 다양한 생체재료들이 이식용 인공장기나 의료용 장비로 폭넓게 사용되고 있으나 혈액과 접촉하는 경우가 많아짐으로써 발생되는 혈전의 문제로 인해 이식재와 혈액간의 혈액 친화성의 향상이 연구자들에게 관심의 대상이 되고 있다. 연잎의 표면구조는 항 오염 특성이라는 측면에서 많은 연구가 진행되어 왔으며, 산업적인 용도로 적용하고자 하는 주된 시도들이 있어 왔다. 대부분 주형법이나 졸-젤 방법, 층 쌓기 방법 등을 포함한 다양한 기법으로 표면처리를 함으로써 인위적인 모사가 가능해 왔다. 최근에 들어 이러한 표면의 초소수성 성질이 의료용 재료의 표면처리 기법으로써 혈관 이식재에서부터 항 박테리아용 표면에까지 널리 적용하려는 시도가 진행되고 있다. 본 리뷰논문에서는 최근 많이 사용되는 연잎 구조로의 표면처리 기법들을 중심으로 요약하였으며, 이들을 이용한 의료분야로의 적용 시도들을 정리하고자 하였다.

변형후 형상의 최적화를 위한 동맥과 PTFE 문합의 직경비 연구 (The Study on the Diameter Ratio of the Artery-PTFE Anastomosis for the Optimized Deformed Shape)

  • 이성욱;심재준;한근조
    • 대한의용생체공학회:의공학회지
    • /
    • 제24권2호
    • /
    • pp.113-119
    • /
    • 2003
  • 본 연구에서는 end-to-end 문합시 변형된 직경의 불일치로 인하여 발생하게 되는 혈관질환을 방지하기 위하여 기계역학적 거동을 유한요소 법을 이용하여 해석한 결과를 나타내었다. 이 연구에서는 서로 다른 직경을 가지는 동맥과 인공혈관인 PTFE의 문합시 봉합으로 인한 예변형을 고려하였으며, 봉합된 문합부에 수축기혈압인 120mmHg(16.0KPa)을 작용시켜 혈관의 변형을 분석하였다. 변형 후 최종 문합부의 형상은 동맥과 PTFE의 초기 직경비(R$_{I}$)와 PTFE의 두께에 대하여 분석하였다. 그리고 동맥과 PTFE의 초기 직경비가 문합부에서 발생되는 응력에 어떠한 영향을 미치는지에 대하여 해석하여 다음과 같은 결과를 얻었다. 1. 혈관내막의 증식등을 고려하지 않고 봉합으로 인한 예변형과 수축기 혈압만을 고려할 경우 가장 이상적인 초기 직경비(R$_{I}$)는 1.073이다. 2. 상당응력과 원주방향응력은 초기 직경비(R$_{I}$) 증가에 따라 증가하며 모두 접합부에서 PTFE측으로 0.4mm 떨어진 지점에서 최대값이 발생하였다.