• 제목/요약/키워드: arterial pulse wave

검색결과 95건 처리시간 0.026초

Association of Uric Acid Levels with Arterial Stiffness in Korean Women and Non-smoking Men

  • Sull, Jae Woong;Koh, Eun Na;Cho, Sung Kweon;Bae, Hyung-Joon;Jee, Sun Ha
    • 대한의생명과학회지
    • /
    • 제23권3호
    • /
    • pp.201-207
    • /
    • 2017
  • Measuring the pulse wave velocity (PWV) is a non-invasive method for evaluating the stiffness of the vessel wall. While previous studies investigated the association of uric acid level with arterial stiffness, most did not consider smoking status and obesity as covariates. The objective of this study was to investigate the relationship between uric acid levels and arterial stiffness, considering smoking status and obesity. We studied 3390 subjects (1940 males and 1450 females). Abnormal PWV was also defined as the highest quartile of values in the subjects. Data were analyzed using Pearson correlation, t-test, and multiple regression analysis. Approximately 41.9% of men and 3.7% of women were current smokers. Prevalence of hypertension was 11.4% in men and 7.0% in women. In women, hyperuricemia was associated with abnormal PWV (OR 1.58; 95% CI 1.03~2.43). Hyperuricemia was also associated with abnormal PWV (OR 2.37; 95% CI 1.01~5.59) in non- or light male smokers with normal blood pressure. This study suggests that uric acid is associated with arterial stiffness in women and non-smoking men.

2차원 배열 자기저항소자를 이용한 공간 맥진파형의 전산모사 분석 (Simulation Analysis of Spatially Arterial Pulse Wave using Two-dimensional Array Sensors with Magnetoresistive Device)

  • 김미선;김선욱;김기왕;이수진;이선구;이현숙;박달호;황도근;이상석
    • 한국자기학회지
    • /
    • 제15권6호
    • /
    • pp.307-310
    • /
    • 2005
  • 요골동맥의 운동에 대한 공간적 맥진파형 특징을 얻기 위해 2차원 배열 자기터널접합(magnetic tunnel junction; MTJ) 센서를 이용하여 공간 맥진파형 진단장치(spatial pulse diagnostic apparatus; SPDA)를 설계하였다. 자극배열의 위치변동에 대한자장 분포의 변화는 2차원 자기장 유한요소해석 소프트웨어(finite element method magnetics; FEMM)를 사용하여 모의실험을 하였다. 그 결과 평행한 자극배열에서 높은 감도와 균일한 자기장 분포를 얻을 수 있다. 또한 자석배열의 공간 변위 변화는 MTJ 센서의 출력신호 변화와 비례하였다.

A Wrist Watch-type Cardiovascular Monitoring System using Concurrent ECG and APW Measurement

  • Lee, Kwonjoon;Song, Kiseok;Roh, Taehwan;Yoo, Hoi-jun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제16권5호
    • /
    • pp.702-712
    • /
    • 2016
  • A wrist watch type wearable cardiovascular monitoring device is proposed for continuous and convenient monitoring of the patient's cardiovascular system. For comprehensive monitoring of the patient's cardiovascular system, the concurrent electrocardiogram (ECG) and arterial pulse wave (APW) sensor front-end are fabricated in $0.18{\mu}m$ CMOS technology. The ECG sensor frontend achieves 84.6-dB CMRR and $2.3-{\mu}Vrms$-input referred noise with $30-{\mu}W$ power consumption. The APW sensor front-end achieves $3.2-V/{\Omega}$ sensitivity with accurate bio-impedance measurement lesser than 1% error, consuming only $984-{\mu}W$. The ECG and APW sensor front-end is combined with power management unit, micro controller unit (MCU), display and Bluetooth transceiver so that concurrently measured ECG and APW can be transmitted into smartphone, showing patient's cardiovascular state in real time. In order to verify operation of the cardiovascular monitoring system, cardiovascular indicator is extracted from the healthy volunteer. As a result, 5.74 m/second-pulse wave velocity (PWV), 79.1 beats/minute-heart rate (HR) and positive slope of b-d peak-accelerated arterial pulse wave (AAPW) are achieved, showing the volunteer's healthy cardiovascular state.

혈장 호모시스테인 농도가 상완-발목 맥파 속도에 미치는 영향 (The Effects of Plasma Homocysteine Concentration on Upper Arm-Ankle Pulse Wave Velocity)

  • 강지훈;신상열
    • 한국산학기술학회논문지
    • /
    • 제20권2호
    • /
    • pp.673-680
    • /
    • 2019
  • 본 연구는 2016년 4월 1일부터 2016년 10월 31일까지 종합병원 건강검진센터에 내원한 435명을 대상으로 혈장 호모시스테인 농도가 정상 호모시스테인 군과 무증상 고호모시스테인 군 간에 발목-상완 pulse wave velocity에 유의한 차이가 있는지를 비교해 심혈관 질환 발생의 향후 예측인자로서 호모시스테인 검사와 동맥의 경직도를 간접적으로 반영하는 상완-발목 pulse wave velocity의 직접적인 상호 연관성을 비교해보고자 시도되었다. 연구결과 고 호모시스테인혈증 군에서 정상 호모시스테인 군에 비해 연령, 허리둘레, BUN, 혈장 크레아티닌이 유의하게 높았고, HDL은 유의하게 낮았다. 또한, 고 호모시스테인혈증은 흡연 및 음주 여부와 관련이 있었으며, 남성에서 유의하게 많았다. 관련 변수를 보정하기 전에는 고 호모시스테인 군에서 우측 및 좌측 상완-발목 맥파 속도가 유의하게 높았으나 관련 변수를 보정한 후에는 두 군의 상완-발목 맥파 속도는 유의한 차이를 보이지 않았다. 따라서, 향후 국내 수검자를 대상으로 호모시스테인 농도를 낮추는 중재적 치료 후 심혈관질환 예방에 대한 독립적 연관성 및 호모시스테인과 신장 기능의 관련성에 대한 추가 연구가 필요하겠다.

손가락 끝 용적맥파를 이용한 자세변화에 따른 맥파 신호에 관한 연구 (On Study of Pulse Wave Signal According to Postural Change Using Finger Plethysmography)

  • 최병철;김철한;정동근;서덕준
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.125-126
    • /
    • 1998
  • Pulse conduction velocity is determined by areterial compliance, which is changed by lateral pressure of arterial wall. Hydrostatic pressure of the limb vessel is changed by body position, especially in elevated arm. The arterial pulse in the finger causes the blood volume to change, changing the optical density of the blood. Photoplethysmograph of index finger was obtained by LED and phototransistor. Pulse transmission time(PTT) was measured by the interval between the peak of ECG R wave and the peak of the finger plethysmogram. PTT was increased by upward position of arm, and decreased by downward position of the arm compared to horizontal position. This result suggests that relationship between finger plethysmography and postural change could be applied to evaluate clinical cardiovascular status.

  • PDF

영구자석-홀 맥진센서를 이용한 양손 동시측정 맥진파형 비교 연구 (Comparison of Simultaneously Measured Pulse Waveforms from Both Hands using Permanent Magnet-Hall Pulsimeter Sensor)

  • 유기두;황성기;이상석
    • 한국자기학회지
    • /
    • 제22권1호
    • /
    • pp.27-31
    • /
    • 2012
  • 영구자석과 홀소자로 구비된 두 대의 집게형 맥진기 시제품을 이용하여 비가압 상태에서 양손 요골동맥의 맥진파형을 동시측정한 신호들을 비교 분석하였다. 20대 남성 피실험자 22명을 대상으로 측정된 오른손잡이와 왼손잡이의 두 맥진파형들은 위상차를 갖고 뚜렷하게 구별되었다. 서로 다른 빠름과 늦음으로 인해 두 개의 맥진파형들의 위상차 부호는 맥파전달속도가 오른손과 왼손 혈관의 총길이 보다는 자주 사용하는 팔의 근육 특성에 의존한다는 분석이 가능하였다.

탄성밴드 저항운동이 고령여성의 신체조성, 혈관탄성 및 낙상위험도지수에 미치는 영향 (Effects of Elastic Band Resistance Training on Body Composition, Arterial Compliance and Risks of Falling Index in Elderly Females)

  • 박혁;김대열
    • 한국산학기술학회논문지
    • /
    • 제18권3호
    • /
    • pp.199-208
    • /
    • 2017
  • 신체조성과 혈관탄성의 변화로 인한 심혈관질환과 근감소로 인한 낙상의 발생은 노화로 인하여 가장 빈번하게 발생하게 된다. 그래서 탄력밴드 저항운동은 노인들이 쉽고 안전하게 수행할 수 있으며 신체조성과 혈관탄성에 긍정적인 영향을 미칠 수 있을 것이다. 따라서 본 연구는 고령여성(>65 years)을 대상으로 12주간 저항운동을 실시한 후 신체조성, 혈관탄성, 낙상위험도지수에 어떠한 효과를 미치는지에 대하여 살펴보았다. 저항운동은 주3회 한 회당 60분으로 구성되었고 운동 강도는 Borg의 운동자각도(6 - 20)에서 11-14로 설정되었다. 신체조성에 해당하는 체중, 근육량, 체지방률, BMI(Body Mass Index)와, 혈관탄성(맥파속도 (Pulse wave velocity (PWV)), 낙상위험도지수(Risk of falling)는 훈련 전과 후에 측정이 되었다. 연구 결과 신체조성에서 운동집단의 체중(p=.003), BMI(p=.002), PWV(p=.017), 낙상위험도지수(p=.037)는 유의하게 감소하였으나 통제집단에서 체중(p=.009), BMI(p=.009)는 유의하게 증가하였다. 따라서 여성노인들은 탄력밴드 저항운동을 통해 체중과 BMI를 감소시키고 혈관탄성에 긍정적인 효과를 얻게 되었다. 그리하여 탄력밴드 저항운동은 노인들의 대사증후군, 심혈관질환, 낙상사고의 발생률을 낮출 수 있는 매우 효과적인 운동이라 할 수 있다.

제주 해녀의 맥파전도속도 분석 (The Analysis of Pulse Wave Velocity of Jeju female divers)

  • 이한영
    • 디지털융복합연구
    • /
    • 제13권9호
    • /
    • pp.515-521
    • /
    • 2015
  • 본 연구에서는 우리는 평균 연령이 높은 제주 해녀의 경-대퇴 맥파 전도 속도와 발목-상완지표를 측정하여 찬물에서 산소의 보조 없이 채취활동을 하는 제주 해녀의 동맥 혈관의 경직도를 측정하였으며, 결과는 다음과 같다. 첫째, 경-대퇴 맥파 전도 속도는 동연령대의 일반여성보다 유의하게 낮게 나타났다. 둘째, 발목-상완지표(ABI)는 해녀와 일반여성 모두 정상범위 안에 포함되어 있었으며, 일반여성보다 해녀집단이 높은 경향을 보였다. 이러한 결과는 고령의 나이임에도 불구하고 장기간 침수활동을 통해 신체의 적응이 이미 완료된 상태로써 저온 및 높은 수압환경에 대한 적응이 완료된 신체상태이며, 아울러 높은 신체활동 수준으로 인하여 말초혈관저항이 고연령임에도 불구하고 감소되지 않았으며, 오히려 동연령 여성들보다 양호한 수준임을 확인할 수 있었다. 하지만 해녀들의 고령화는 여전히 진행되고 있는 중요한 현상이기에 동맥혈관경직도에 대한 관심과 향후의 지속적인 연구는 반드시 더 필요할 것으로 보인다.

맥진연구를 위한 심혈관계 시뮬레이터의 개발 (Development of the Cardiovascular Simulator for Pulse Diagnosis Study)

  • 이주연;신상훈
    • 대한한의진단학회지
    • /
    • 제16권1호
    • /
    • pp.19-26
    • /
    • 2012
  • Objectives The aim of this study is to develop a cardiovascular simulator that can reproduce blood pressure pulse and blood flow similar to those of the human body. Methods In order to design a system similar to the human cardiovascular system, the required performances were determined by investigating the hemodynamic characteristics of the heart and the arterial system. Main organ to be imitated is heart in simulator. The rest of the system was minimally designed. Also, a blood pressure and blood flow measurement system was developed for measuring the results. Results The developed system showed blood pressure pulse at similar range of the human aorta. The result waveform include primary wave caused by ventricular systole except reflected wave. Conclusions The blood pressure and blow flow patterns were replicated by the simulator. These patterns were similar to those of the human body. The system will play an important role in studying pulse diagnostics.

Fuzzy Simulation of a Multi-electronic Acupuncture System and Clip-type Pulsimeter Equipped with a Magnetic Sensing Hall Device

  • Hong, You-Sik;Rhee, Jin-Kyu;Kim, Han-Kyu;Son, Il-Ho;Yoon, Woo-Sung;Lee, Nam-Kyu;Park, Do-Young;Kim, Keun-Ho;Kim, Yong-Jin;Khajidmaa, P.;Lee, Sang-Suk
    • Journal of Magnetics
    • /
    • 제19권3호
    • /
    • pp.255-260
    • /
    • 2014
  • A portable clip-type pulsimeter equipped with a magnetic sensing Hall device has been developed to raise the accuracy of oriental disease diagnosis and therapy by convergence of magnetism and oriental medicine. To improve accuracy and reliability of conventional pulsimeter due to subjective analysis of the pulse wave and measuring position dependency of the arterial pulse sensor, the fuzzy algorithm was applied to analyze the strong- and weak-pulse wave symptom. Optimal time for electronic acupuncture was calculated using fuzzy rules and interference were drawn from objective data in view of pre-treatment. Moreover, the electrical characteristics of the pain parts that respond to acupuncture point were applied in view of post-treatment to propose the scientific pulse wave algorithm and simulation experiment.