• Title/Summary/Keyword: arterial compliance

Search Result 51, Processing Time 0.026 seconds

The relationships of body mass index, waist-to-height ratio, and body fat percentage with blood pressure and its hemodynamic determinants in Korean adolescents: a school-based study

  • Kim, Na Young;Hong, Young Mi;Jung, Jo Won;Kim, Nam Su;Noh, Chung Il;Song, Young-Hwan
    • Clinical and Experimental Pediatrics
    • /
    • v.56 no.12
    • /
    • pp.526-533
    • /
    • 2013
  • Purpose: Obesity is an important risk factor for hypertension in adolescents. We investigated the relationship of obesity-related indices (body mass index [BMI], waist-to-height ratio [WHR], and body fat percentage [%BF]) with blood pressure and the hemodynamic determinants of blood pressure in Korean adolescents. Methods: In 2008, 565 adolescents, aged 12-16 years, were examined. The %BF of the participants was measured by bioelectrical impedance analysis. Echocardiography and brachial artery pulse tracing were used to estimate the stroke volume (SV), cardiac output (CO), total vascular resistance (TVR), and total arterial compliance (TAC). Results: We noted that BMI, WHR, and %BF were positively correlated with systolic blood pressure (SBP) and diastolic blood pressure (DBP). The positive correlation between BMI and blood pressure (SBP and DBP) persisted after adjustment for WHR and %BF. However, after adjustment for BMI, the positive associations between blood pressure (SBP and DBP) and WHR as well as %BF, were not noted. With regard to the hemodynamic factors, BMI, but not WHR and %BF, was an independent positive factor correlated with SV and CO. TVR had an independent negative association with BMI; however, it was not associated with WHR or %BF. Moreover, we noted that BMI, WHR, and %BF did not affect TAC. Conclusion: In Korean adolescents, BMI had an independent positive correlation with SBP and DBP, possibly because of its effects on SV, CO, and TVR. WHR and %BF are believed to indirectly affect SBP and DBP through changes in BMI.

Development of Feature Points Detection Algorithm for Measuring of Pulse Wave Velocity (맥파 전달 속도(PWV) 측정을 위한 특징점 검출 알고리즘 개발)

  • Choi, Jung-Hyeon;Cho, Wook-Hyun;Park, Jun-Ho;Kim, Nam-Hoon;Seong, Hyang-Sook;Cho, Jong-Man
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.343-350
    • /
    • 2011
  • The compliance and stiffness of artery are closely related with disease of arteries. Pulse wave velocity(PWV) in the blood vessel is a basic and common parameter in the hemodynamics of blood pressure and blood flow wave traveling in arteries because the PWV is affected directly by the conditions of blood vessels. However, there is no standardized method to measure the PWV and it is difficult to measure. The conventional PWV measurement has being done by manual calculation of the pulse wave transmission time between coronary arterial proximal and distal points on a strip chart on which the pulse wave and ECG signal are recorded. In this study, a pressure sensor consisting of strain gauges is used to measure the blood pressure of arteries in invasive method and regular ECG electrodes are used to record the ECG signal. The R-peak point of ECG is extracted by using a reference level and time windowing technique and the ascending starting point of blood pressure is determined by using differentiation of the blood pressure signal and time windowing technique. The algorithm proposed in this study, which can measure PWV automatically, shows robust and good results in the extraction of feature points and calculation of PWV.

Development of Porous polyurethane Arterial-Venous Shunt by Thermal Control (온도 조절을 통한 다공성 폴리우레탄 동정맥 누관의 개발)

  • Jeong, J.S.;Ryu, G.H.;Kim, J.;Min, B.G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.478-481
    • /
    • 1997
  • A technique or the preparation of porous polyurethane vascular prostheses was investigated. Small-diameter vessels are not in general clinical use due to their limited long-term biocompatibility and low patency rates in experimental trial. These limits are mainly due to the failure of mechanical unction of the vascular grafts. This failure has been suggested to result partially from compliance mismatch. The long-term patency is considered to depend critically on the properties of the material and the fabrication process of the graft. So the control of pores is very important and main points to develop a available vascular grafts. Two-kind polymer sheets was compared. One was the porous PU-sheet made at room temperature by the solvent/non-solvent exchange. And the other was the porous PU-sheet which was fabricated by thermal phase transition and solvent-/non-solvent exchange using the thermal controller. The polymer sheets had a uniform pore size and pore occupation. According to the result of the above experiments, polyurethane solution was injected into a mold designed or U-type tube. The average pore size and pore occupation were easily changed by changing polyurethane concentration, freezing temperature, and methods. This technique can give a proper pore size ($10{\sim}45\;{\mu}m$) or tissue in growth, and suitable compliances or matching with arteries and veins. Besides, the fabrication of more complicated shaped vessels such as the U-type vascular grafts is easily controlled by using the fixed mold. this method might give a desired compliant graft or artificial implantation with the presently valid medical polymers.

  • PDF

Computational Study on the Hemodynamics of the Bypass Shunt Directly Connecting the left Ventricle to a Coronary Artery

  • Shim Eun Bo;Lee Byung Jun;Ko Hyung Jong
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.1158-1168
    • /
    • 2005
  • A shunt from the left ventricle to the left anterior descending artery is being developed for coronary artery occlusive disease, in which the shunt or conduit connects the the left ventricle (LV) with the diseased artery directly at a point distal to the obstruction. To aid in assessing and optimizing its benefit, a computational model of the cardiovascular system was developed and used to explore various design conditions. Computational fluid dynamic analysis for the shunt hemodynamics was also done using a commercial finite element package. Simulation results indicate that in complete left anterior descending artery (LAD) occlusion, flow can be returned to approximately 65% of normal, if the conduit resistance is equal for forward and reverse flow. The net coronary flow can increase to 80% when the backflow resistance is infinite. The increases in flow rate produced by asymmetric flow resistance are enhanced considerably for a partial LAD obstruction, since the primary effect of resistance asymmetry is to prevent leakage back into the ventricle during diastole. Increased arterial compliance has little effect on net flow with a symmetric shunt, but considerably augments it when the resistance is asymmetric. The computational results suggest that an LV-LAD conduit will be beneficial when the resistance due to artery stenosis exceeds 27 PRU, if the resistance is symmetric. Fluid dynamic simulations for the shunt flow show that a recirculating region generated near the junction of the coronary artery with the bypass shunt. The secondary flow is induced at the cutting plane perpendicular to the axis direction and it is in the attenuated of coronary artery.

Compensation of the Error Rate for the Non-invasive Sphygmomanometer System Using a Tactile Sensor

  • Jeong, In-Cheol;Choi, Yoo-Nah;Yoon, Hyung-Ro
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.1
    • /
    • pp.136-141
    • /
    • 2007
  • The Purpose Of This Paper Is To Use A Tactile Sensor To Compensate The Error Rate. Most Automated Sphygmomanometers Use The Oscillometric Method And Characteristic Ratio To Estimate Systolic And Diastolic Blood Pressure. However, Based On The Fact That Maximum Amplitude Of The Oscillometric Waveform And Characteristic Ratio Are Affected By Compliance Of The Aorta And Large Arteries, A Method To Measure The Artery Stiffness By Using A Tactile Sensor Was Chosen In Order To Integrate It With The Sphygmomanometer In The Future Instead Of Using Photoplethysmography. Since Tactile Sensors Have Very Weak Movements, Efforts Were Made To Maintain The Subject's Arm In A Fixed Position, And A 40hz Low Pass Filter Was Used To Eliminate Noise From The Power Source As Well As High Frequency Noise. An Analyzing Program Was Made To Get Time Delay Between The First And Second Peak Of The Averaged Digital Volume Pulse(${\Delta}t_{dvp}$), And The Subject's Height Was Divided By ${\Delta}t_{dvp}$ To Calculate The Stiffness Index Of The Arteries($Si_{dvp}$). Regression Equations Of Systolic And Diastolic Pressure Using $Si_{dvp}$ And Mean Arterial Pressure(Map) Were Computed From The Test Group (60 Subjects) Among A Total Of 121 Subjects(Age: $44.9{\pm}16.5$, Male: Female=40:81) And Were Tested In 61 Subjects To Compensate The Error Rate. Error Rates Considering All Subjects Were Systolic $4.62{\pm}9.39mmhg$, And Diastolic $14.40{\pm}9.62mmhg$, And Those In The Test Set Were $3.48{\pm}9.32mmhg,\;And\;14.34{\pm}9.67mmhg$ Each. Consequently, Error Rates Were Compensated Especially In Diastolic Pressure Using $Si_{dvp}$, Various Slopes From Digital Volume Pulse And Map To Systolic-$1.91{\pm}7.57mmhg$ And Diastolic $0.05{\pm}7.49mmhg$.

Comparison of Hemodynamic Energy between Expanded Polytetrafluoroethylene and Dacron Artificial Vessels

  • Lim, Jaekwan;Won, Jong Yun;Ahn, Chi Bum;Kim, Jieon;Kim, Hee Jung;Jung, Jae Seung
    • Journal of Chest Surgery
    • /
    • v.54 no.2
    • /
    • pp.81-87
    • /
    • 2021
  • Background: Artificial grafts such as polyethylene terephthalate (Dacron) and expanded polytetrafluoroethylene (ePTFE) are used for various cardiovascular surgical procedures. The compliance properties of prosthetic grafts could affect hemodynamic energy, which can be measured using the energy-equivalent pressure (EEP) and surplus hemodynamic energy (SHE). We investigated changes in the hemodynamic energy of prosthetic grafts. Methods: In a simulation test, the changes in EEP for these grafts were estimated using COMSOL MULTIPHYSICS. The Young modulus, Poisson ratio, and density were used to analyze the grafts' material properties, and pre- and post-graft EEP values were obtained by computing the product of the pressure and velocity. In an in vivo study, Dacron and ePTFE grafts were anastomosed in an end-to-side fashion on the descending thoracic aorta of swine. The pulsatile pump flow was fixed at 2 L/min. Real-time flow and pressure were measured at the distal part of each graft, while clamping the other graft and the descending thoracic aorta. EEP and SHE were calculated and compared. Results: In the simulation test, the mean arterial pressure decreased by 39% for all simulations. EEP decreased by 42% for both grafts, and by around 55% for the native blood vessels after grafting. The in vivo test showed no significant difference between both grafts in terms of EEP and SHE. Conclusion: The post-graft hemodynamic energy was not different between the Dacron and ePTFE grafts. Artificial grafts are less compliant than native blood vessels; however, they can deliver pulsatile blood flow and hemodynamic energy without any significant energy loss.

Change of early atherosclerotic markers in obese children (비만아에서 조기 동맥경화증 지표들의 변화)

  • Roh, Eui Jung;Yoon, Jung Min;Lim, Jae Woo;Cheon, Eun Jung;Ko, Kyoung Og
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.4
    • /
    • pp.368-374
    • /
    • 2006
  • Purpose : The prevalence of obesity in children is increasing rapidly. Epidemiologic studies suggest that obesity induced atherosclerosis may start in childhood. We investigated whether obese children show early abnormalities of the arterial wall and endothelial dysfunction. Methods : Thirty-eight obese children(14-16 years old of age, male, body mass index $29.40{\pm}3.18kg/m^2$) and forty-five age and sex-matched healthy control children(body mass index $18.43{\pm}1.01kg/m^2$) were enrolled. Their carotid artery intima-media thickness(IMT) and brachial artery flowmediated dilation(FMD) response were measured by high-quality ultrasound system, and compliance, distensibility, stiffness index, incremental elastic modulus and wall stress were calculated by equation. In addition, we looked at the relations between these arterial features and metabolic cardiovascular risk factors. Results : The obese children had significantly increased IMT($0.52{\pm}0.09mm$ vs $0.40{\pm}0.07mm$, P< 0.001) and markedly impaired FMD($7.35{\pm}7.78$ percent vs $20.34{\pm}16.81$ percent, P<0.001) than the healthy controls. But the compliance and distensibility were lower, and the stiffness index, incremental elastic modules and wall stress were higher in the obese group than the control group, but not statistically significantly. Body mass index was highly associated with increased IMT(r=0.612, P<0.001) and reduced FMD(r=-0.414, P<0.001). Conclusion : We showed the deleterious effect of child obesity on both early functional and structural atherosclerotic markers. The ultrasonic findings will be used for screening and follow up markers to identify high-risk patients among obese children.

A Study on the Physiological and Psychological Factors related to Successful Weaning from a Mechanical Ventilator (기계환기기 이탈의 성공과 관련된 생리적${\cdot}$심리적 요인에 관한 조사 연구)

  • Kim, Cho-Ja;Kim, Hwa-Soon;Jang, Yeon-Soo;Kim, Eun-Sung
    • Journal of Korean Academy of Nursing
    • /
    • v.30 no.4
    • /
    • pp.995-1005
    • /
    • 2000
  • This study was performed to identify the physiological and psychological variables related to successful weaning from a mechanical ventilator. The subjects of this study were 22 patients who received mechanical ventilation therapy for more than 3 days in intensive care units. Before the weaning trial, baseline data for following physiologic variables were obtained: spontaneous respiration rate, blood pressure, pulse rate, PaO2, PaCO2, PEEP, static compliance, minute ventilation, tidal volume, rapid shallow breathing index(f/VT), SaO2, PaO2/FiO2 and mean arterial pressure. During spontaneous breathing, physiologic and psychologic variables such as vital signs, ABG, perspiration, chest retraction, paradoxical respiration, dyspnea, anxiety, confidence and efficacy were measured. Successful weaning was defined as sustaining spontaneous respiration over 24 hours after extubation. Weaning failure was defined as the development of more than one of following signs: (1) hypoxemia, (2) CO2 retention or (3) perspiration, tachypnea, chest retraction, tachycardia, arrhythmia, hypotension or hypertension. Subjects (N=18) who successfully weaned from mechanical ventilator were compared with subjects (N=4) who failed. The results are as follows; Eighteen percents of the subjects failed during the weaning trial. Most subjects in the failed group were mechanically ventilated for long-time. This result shows that the success of weaning is more difficult in long-term ventilation patients. In the baseline data that was measured before weaning trial, the mean score of PaO2 in the successfully weaned group was 121mmHg. This is significantly higher than the mean score of PaO2 in the failed group(95mmHg). However, the scores of pH, tidal volume, f/VT, pulse rates, blood pressure, mean airway pressure, SaO2, and PaCO2 were similar between the two groups. Specially the scores of f/VT index as a predominant predictor for successful weaning were not significant (f/VT=44.4) and (f/VT=47). During spontaneous breathing, the scores of dyspnea and anxiety level in the successfully weaned group were less than those of the failed group. On the contrary, the scores of confidence and efficacy in the successful group were greater than those of the failed group. In conclusion, the baseline data that were measured before weaning trial were similar between the both groups, therefore future studies are needed to focus on searching other variables besides physiological parameters related to weaning outcome.

  • PDF

Treatment of Pulmonary Sequestration with Thoracoscopic Approach (폐분리증의 치료와 흉강경적 절제술의 경험)

  • Cho, Min-Jeng;Kim, Tae-Hoon;Kim, Dae-Yeon;Kim, Seong-Chul;Kim, In-Koo
    • Advances in pediatric surgery
    • /
    • v.16 no.2
    • /
    • pp.154-161
    • /
    • 2010
  • Pulmonary sequestration (PS) is a rare congenital malformation of the lower respiratory tract. The anomaly is characterized by absence of communication with the tracheobronchial tree and isolated blood supply from an anomalous systemic vessels. With the utilization of antenatal ultrasound, the diagnosis of asymptomatic neonatal PS has increased. Treatment options include observation, arterial embolization and surgical resection. The aim of the present study is to review the clinical course of PS and to share our experience with thoracoscopic resection. A total of 96 patients with PS were treated at Asan Children's Hospital between 1999 and 2010. The diagnosis of PS was established by CT in the cases managed by observation or embolization, and by tissue pathology in the surgical cases. Medical records and radiographic images were retrospectively reviewed. Thirty-nine patients were managed by embolization and 30 patients by surgery. The remaining 27 patients have been under observation without any procedures. Among 27 observation patients, 1 patient regressed completely and 10 patients were lost to follow up. Of the 39 embolizations patients, 2 had their lesion regress and sepsis was suspected after embolization. In 1 patient, the microcoil migrated to the iliac artery during the embolization procedure, and another patient developed renal abscess caused by renal artery embolization. Among 30 surgical cases, resection by thoracotomy was performed in 27 at the Department of Thoracic Surgery, and thoracoscopic resection in 3 at the Division of Pediatric Sugery. Only one wound complication ocurred. We conclud that surgical excision should be recommended for pulmonary sequestration, whether the sequestration is symptomatic or not because of the risk of infection, the low rate of natural regress, poor compliance, severe complications after embolization, and to exclude other pathology. In summary, thoracoscopic resection of the pulmonary sequestration is feasible, efficacious, safe and cosmetically superior even in neonatal period.

  • PDF

Comparative Study on the Pulse Wave Variables and Sasang Constitution in Diabetes Mellitus Patients and Healthy Subjects (당뇨병 환자와 건강인의 맥상과 사상체질에 관한 연구)

  • Park, Su-Jeong;Kim, Kyung-Yo;Lee, Si-Woo;Kwon, Young-Mi;Kil, Eun-Young;Joo, Jong-Cheon
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.21 no.6
    • /
    • pp.1601-1610
    • /
    • 2007
  • The purpose of this study was to determine whether a pulse analyzer was useful 1) to characterize the variables of pulse wave of diabetes mellitus group, compared with those of healthy subjects, and 2) to determine Sasang Constitution in diabetes mellitus group and healthy subjects. 1. The sum of pulse pressure (energy) and the ratio of systolic period area (As%), called pulse pressure-related variables, were higher in diabetes mellitus group than healthy group, while the height of dicrotic wave (h5) and the ratio of height of dicrotic wave to height of percussion wave (h5/h1), correlated with arterial compliance, were lower in diabetes mellitus group than healthy group. 2. Taeumin of diabetes mellitus group showed higher pressure-related variables than that of healthy group. 3. Soumin of diabetes mellitus group had shorter the time to dicrotic wave (t5) than that of healthy group. 4. Soyangin of diabetes mellitus group showed higher heart rates and lower values in pulse wave time-related variables, including time to dicrotic wave(t5), time to incisura (t4), total time minus time to incisura (t-t4), total time (t), width of percussion wave (w), and the ratio of width of percussion wave to total time (w/t), than that of healthy group. 5. Contact pressure (CP), sum of pulse pressure (energy), height of pre-incisura (h2), height of incisura (h4), width of percussion wave (w), time to incisura (t4), time to percussion wave (t1), variance of total time (Vt), variance of height of percussion wave(Vp) and the ratio of height of incisura to height of percussion wave (h4/h1) were used to develop the rules of Sasang Constitution Classification with about seventy five percents accuracy. These suggested that the pulse analyzer was useful to evaluate the risk degree of diabetes mellitus and to determine Sasang Constitution among either diabetes mellitus group or healthy group.