• Title/Summary/Keyword: arterial blood pressure fluctuation

Search Result 5, Processing Time 0.021 seconds

Assessments of baroreflex sensitivity through the closed-loop feedback model between RR fluctuation and arterial blood pressure fluctuation (RR간격변동과 열합변동간의 폐루프 귀환 모델을 통한 압수용체반사감도의 평가)

  • 신건수;최석준;이명호
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1643-1646
    • /
    • 1997
  • In this study, the method is proposed, which enable us to noninvasively assess baroreflex sensitivity through the closed-loop feedback modle between RR flucturarion and arterial blood pressure fluctuation. The proposed indexes of baroreflex sensitivity, BRS$_{LF}$와 BRS$_{HF}$ are calculated by the modulus (or gain) of the transfer function between fluctuatuons in blood pressure and RR interval in the LF band HF band, where the coherence is more than 0.5 to evaluate the performance of the proposed method, it is applied to various cardiovascular variability signals obtained form subjects under the submaximal ecericse on bicycle ergometner. In result it is concluded that the proposed method can noninvasively assess the baroreflex sensitivity.ty.

  • PDF

The Comparison of the Effects of Nicardipine and Remifentanil on Fluctuation of Blood Pressure during Controlled Hypotension (유도 저혈압하 양악 교정술 시 Nicardipine과 Remifentanil의 혈역학적 비교)

  • Kim, Eun-Soo;Hwang, Boo-Young;Kim, Cheul-Hong
    • Journal of The Korean Dental Society of Anesthesiology
    • /
    • v.10 no.2
    • /
    • pp.166-171
    • /
    • 2010
  • Background: Controlled hypotension is used to reduce bleeding and improve surgical conditions during surgery. Nicardipine and remifentanil have been used to induce controlled hypotension in healthy patients. This study compared controllability of nicardipine and remifentanil on hemodynamic stability during controlled hypotension. Methods: Forty healthy patients scheduled for orthognathic two jaw surgery were randomly allocated to nicardipine (group N) and remifentanil (group R) group. After induction of anesthesia, group N (n = 20) was infused with nicardipine to induce hypotension and group R (n = 20) was infused with remifentanil. Mean arterial pressure (MAP) and heart rate (HR) were measured over 5 minute interval. Surgical field rating and blood loss were measured after surgery. Results: HR was lower in group R than group N. MAP was maintained at 50-60 mmHg during controlled hypotension but the fluctuation of blood pressure and HR were more frequent in group N than group R. There were no significant differences in the surgical field rating and blood loss between the groups. Conclusions: Nicardipine and remifentanil enabled controlled hypotension and provided good surgical conditions, but the fluctuation of hemodynamic parameters was more frequent in nicardipine group.

Various Factors Influencing Thoracic Duct Lymph Flow in the Dogs (임파유통에 영향을 주는 인자에 관한 실험적 연구)

  • Kim, Ki-Whan;Earm, Yung-E
    • The Korean Journal of Physiology
    • /
    • v.9 no.1
    • /
    • pp.45-56
    • /
    • 1975
  • Various factors influencing the lymph flow from thoracic duct were investigated in an attempt to evaluate their contributing degree and the mechanisms. Sixteen mongrel dogs weighing between 10 and 16 kg were anesthetized and polyethylene catheters were inserted into the thoracic duct and femoral veins. Arterial blood pressure, heart rate, central venous pressure, lymph pressure and lymph flow were measured under various conditions. Electrical stimulation of left sciatic nerve, stepwise increase of central venous pressure, manual application of rhythmical depressions onto abdomen, injection of hypertonic saline solution and histamine infusion were employed. Measurement of cental venous pressure was performed through the recording catheter inserted into abdominal inferior vena cava. Changes in central venous pressure were made by an air-ballooning catheter located higher than the tip of the recording catheter in the inferior vena cava. Lymph flow from thoracic duct was measured directly with a graduated centrifuge tube allowing the lymph to flow freely outward through the inserted cannula. The average side pressure of thoracic lymph was $1.1\;cmH_2O$ and lymph flow was 0.40 ml/min or 1.9 ml/kg-hr. Hemodynamic parameters including lymph flow were measure immediately before and after (or during) applying a condition. Stimulation of left sciatic nerve with a square wave (5/sec, 2 msec, 10V) caused the lymph flow to increase 1.4 times. The pattern of lymph flow from thoracic duct was not continuous throughout the respiratory cycle, but was continuous only during Inspiration. Slow and deep respiration appeared to increase the lymph flow than a rapid and shallow respiration. Relationship between central venous pressure and the lymph flow revealed a relatively direct proportionality; Regression equation was Lymph Flow (ml/kg-hr)=0.09 CVP$(cmH_2O)$+0.55, r=0.67. Manual depressions onto the abdomen in accordance with the respiratory cycle caused the lymph flow to increase most remarkably, e.g,. 5.5 times. The application of manual depressions showed a fluctuation of central venous pressure superimposed on the respiratory fluctuation. Hypertonic saline solution (2% NaCl) administered Intravenously by the amount of 10 m1/kg increased the lymph flow 4.6 times. The injection also increased arterial blood pressure, especially systolic Pressure, and the central venous pressure. Slow intravenous infusion of histamine with a rate of 14-32 ${\mu}g/min$ resulted in a remarkable increase in the lymph flow (4.7 times), in spite of much decrease in the blood pressure and a slight decrease in the central venous pressure.

  • PDF

A Study on Assessments of Baroreflex Sensitivity through the Closed-loop Feedback Model of Cardiovascular System (심혈관계의 폐루프 귀환 모델을 통한 압수용체반사감도의 평가에 관한 연구)

  • Choi, S.J.;Shin, K.S.;Lee, M.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.447-450
    • /
    • 1997
  • In this paper, the method is proposed, which enables us to assess baroreflex sensitivity noninvasively through the closed-loop feedback model between RR fluctuation and arterial blood pressure fluctuation, which are obtained in blood low signals. The proposed indexes of baroreflex sensitivity, $BRS_{LF}$ and $BRS_{HF}$, are calculated by the modulus(or gain) of the transfer unction between two fluctuations above in LF band and HF band, where the coherence is more than 0.5. To evaluate the performance of the proposed method, it is applied to blood low signals obtained from subjects at tilt angles of $0^{\circ},\;45^{\circ},\;90^{\circ}$ and $0^{\circ}$ successively. In result, it is concluded that the proposed method enables us to assess baroreflex sensitivity noninvasively.

  • PDF

Application of the Pulsatile Cardiopulmonary Bypass in Animal Model (이중 박동성 인공심폐기의 동물 실험)

  • Shin, Hwa-Kyun;Won, Yong-Soon;Lee, Jea-Yook;Her, Keun;Yeum, Yook;Kim, Seung-Chul;Min, Byoung-Goo
    • Journal of Chest Surgery
    • /
    • v.37 no.1
    • /
    • pp.1-10
    • /
    • 2004
  • Background: Currently, the cardiopulmonary machine with non-pulsatile pumps, which are low in internal circuit pressure and cause little damage to blood cells, is widely used. However, a great number of experimental studies shows that pulsatile perfusions are more useful than non-pulsatile counterparts in many areas, such as homodynamic, metabolism, organ functions, and micro-circulation. Yet, many concerns relating to pulsatile cardiopulmonary machines, such as high internal circuit pressure and blood cell damage, have long hindered the development of pulsatile cardiopulmonary machines. Against this backdrop, this study focuses on the safety and effectiveness of the pulsatile cardiopulmonary machines developed by a domestic research lab. Material and Method: The dual-pulsatile cardiopulmonary bypass experiment with total extracorporeal circulation was conducted on six calves, Extracorporeal circulation was provided between superior/inferior vena cava and aorta. The membrane oxygenator, which was placed between the left and right pumps, was used for blood oxygenation. Circulation took four hours. Arterial blood gas analysis and blood tests were also conducted. Plasma hemoglobin levels were calculated, while pulse pressure and internal circuit pressure were carefully observed. Measurement was taken five times; once before the operation of the cardiopulmonary bypass, and after its operation it was taken every hour for four hours. Result: Through the arterial blood gas analysis, PCO2 and pH remained within normal levels. PO2 in arterial blood showed enough oxygenation of over 100 mmHg. The level of plasma hemoglobin, which had total cardiopulmonary circulation, steadily increased to 15.87 $\pm$ 5.63 after four hours passed, but remained below 20 mg/㎗. There was no obvious abnormal findings in blood test. Systolic blood pressure which was at 97.5$\pm$5.7 mmHg during the pre-circulation contraction period, was maintained over 100 mmHg as time passed. Moreover, diastolic blood pressure was 72.2 $\pm$ 7.7 mmHg during the expansion period and well kept at the appropriate level with time passing by. Average blood pressure which was 83$\pm$9.2 mmHg before circulation, increased as time passed, while pump flow was maintained over 3.3 L/min. Blood pressure fluctuation during total extracorporeal circulation showed a similar level of arterial blood pressure of pre-circulation heart. Conclusion: In the experiment mentioned above, pulsatile cardiopulmonary machines using the doual-pulsatile structure provided effective pulsatile blood flow with little damage in blood cells, showing excellence in the aspects of hematology and hemodynamic. Therefore, it is expected that the pulsatile cardiopulmonary machine, if it becomes a standard cardiopulmonary machine in all heart operations, will provide stable blood flow to end-organs.