Classification of Indoor Environmental Gases Using Temperature Modulation (열적 변화를 이용한 실내환경 가스의 분류)

  • Choi, Nak-Jin;Shim, Chang-Hyun;Song, Gap-Duk;Joo, Byung-Su;Lee, Yun-Su;Lee, Sang-Moon;Lee, Duk-Dong;Huh, Jeung-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.11 no.5
    • /
    • pp.279-285
    • /
    • 2002
  • Two $SnO_2$ based sensing films(pure $SnO_2$ and $SnO_2$/Pt) and a Pt thin film for temperature sensor on an alumina substrate were designed and fabricated for classifying the indoor environmental gases. By controlling the heating power in the shape of trapezoid, unique four sensing response curves created from both $SnO_2$ film and $SnO_2$/Pt film. Then, various parameters were extracted from sensing response curves and carried out principal component analysis(PCA). The results confirm that a sensor array with the proposed operating mode was extremely effective in classifying indoor environmental gases such as $CO_2$, $C_3H_8$, $C_4H_{10}$.

Fiber-Optic Interferometric Sensor System for Remote Sensing and Its Application to Pressure Sensing (원격 측정을 위한 간섭형 광섬유 센서 시스템과 그의 압력 센서 응용)

  • Yeh, Yun-Hae;Jung, Hwan-Soo;Lah, Doh-Sung
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.3
    • /
    • pp.172-179
    • /
    • 1997
  • This paper describes a multiplexed-multivariate fiber-optic interferometric sensor system with remote sensing capability. Signal processor of the implemented sensor system is designed as a digital fringe counter that is well adapted to the signal processing of the remote fiber-optic Fabry-Perot interferometric sensor array. By summing up the reported optical data of the optical fiber, a guideline for choosing the optical effect suitable for a specific measurand is presented. As an example, a pressure sensing device that utilizes the strain-optic effect of the optical fiber by attaching it onto a stainless steel diaphragm of which diameter is 4.3 cm, is built and attached to the sensor system. The changes in optical phase difference of the fiber-optic Fabry-Perot interferometric press ure sensor while filling a water tank 2 meters high, was counted by the half-fringe counting signal processor. Test results showed that the measurement error is less than ${\pm}3.6\;cm$ over the measured range of 2 meters.

  • PDF

스퍼터링 방법으로 성장시킨 나노구조의 Ga 농도 변화에 따른 형상 변화

  • Kim, Yeong-Lee;U, Chang-Ho;Jo, Hyeong-Gyun
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2009.11a
    • /
    • pp.23.1-23.1
    • /
    • 2009
  • ZnO is of great interest for various technological applications ranging from optoelectronics to chemical sensors because of its superior emission, electronic, and chemical properties. In addition, vertically well-aligned ZnO nanorods on large areas with good optical and structural properties are of special interest for the fabrication of electronic and optical nanodevices. To date, several approaches have been proposed for the growth of one-dimensional (1D) ZnO nanostructunres. Several groups have been reported the MOCVD growth of ZnO nanorods with no metal catalysts at $400^{\circ}C$, and fabricated a well-aligned ZnO nanorod array on a PLD prepared ZnO film by using a catalyst-free method. It has been suggested that the synthesis of ZnO nanowires using a template-less/surfactant-free aqueous method. However, despite being a well-established and cost-effective method of thin film deposition, the use of magnetrons puttering to grow ZnO nanorods has not been reported yet. Additionally,magnetron sputtering has the dvantage of producing highly oriented ZnO film sat a relatively low process temperature. Currently, more effort has been concentrated on the synthesis of 1D ZnO nanostructures doped with various metal elements (Al, In, Ga, etc.) to obtain nanostructures with high quality,improved emission properties, and high conductance in functional oxide semiconductors. Among these dopants, Ga-doped ZnO has demonstrated substantial advantages over Al-doped ZnO, including greater resistant to oxidation. Since the covalent bond length of Ga-O ($1.92\;{\AA}$) is nearly equal to that of Zn-O ($1.97\;{\AA}$), high electron mobility and low electrical resistivity are also expected in the Ga-doped ZnO. In this article, we report the successful growth of Ga-doped ZnO nanorods on c-Sapphire substrate without metal catalysts by magnetrons puttering and our investigations of their structural, optical, and field emission properties.

  • PDF

An Electrical Properties of Antifuses based on $BaTiO_3/SiO_2$ films ($BaTiO_3/SiO_2$로 구성된 안티퓨즈의 전기적 특성)

  • Lee, Young-Min;Lee, Jae-Sung;Lee, Yong-Hyun
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.5
    • /
    • pp.364-371
    • /
    • 1998
  • A novel antifuse has been developed for field programmable gate arrays (FPGA's) as a voltage programmable link with Al/$BaTiO_3/SiO_2$/TiW-silicide. The proper program voltage can be obtained by adjusting the deposition thickness of $BaTiO_3$ film. When a negative voltage was applied at bottom TiW-silicide electrode of the antifuse, based on $BaTiO_3(120{\AA})$/$SiO_2(120{\AA})$, the program voltage was about l4.4V and on-resistances were ranged between 40 and $50{\Omega}$. The current-voltage characteristics of antifuses are consistent with a Frenkel-Poole conduction model. However, there are some deviations depending on bias polarity that are probably due to the difference in the interface properties between Al/$BaTiO_3$ and TiW-silicide/$SiO_2$.

  • PDF

Development of an Electronic Nose System for Evaluation of Freshness of Pork (돈육의 신선도 평가를 위한 전자코 시스템 개발)

  • Lee, Hoon-Soo;Cho, Byoung-Kwan;Chung, Chang-Ho;Lee, Ki-Teak;Jo, Cheo-Run
    • Journal of Biosystems Engineering
    • /
    • v.34 no.6
    • /
    • pp.462-469
    • /
    • 2009
  • The aim of this study was to develop a portable electronic nose system for freshness measurement of stored pork. An electronic nose system was constructed using seven different MOS sensor array. To determine the quality change of pork with storage time, the samples were divided into ten groups in terms of storage time with an increment of 2 day up to 19 storage days. GC-MS, total bacteria's count (TBC), thiobarbituric acid reactive substance (TBARS), and pH analyses as well as the analysis of the electronic nose system measurement were performed to monitor the freshness change of the samples. To investigate the performance of the electronic nose system for detecting the change of freshness of pork, the acquired signal values of the system were compared with those of GC-MS, TBC, TBARS, and pH analysis values. According to principal component analysis (PCA) and linear discriminant analysis (LDA) with the signals of the electronic nose system for the pork samples, the sample groups were clearly separated into two groups of 1-9 days and 11-19 days, and four groups of 1-3 days, 5-9 days, 11 days, and 13-19 days respectively. The results show that the electronic nose system has potential for evaluating freshness of pork.

Magnetic Field Analysis for Development of Magnetic Torquer

  • Yim, Jo-Ryeong;Lee, Seon-ho;Rhee, Seung-Wu
    • Bulletin of the Korean Space Science Society
    • /
    • 2003.10a
    • /
    • pp.63-63
    • /
    • 2003
  • There are many actuators and sensors used for attitude control system for KOMPSAT such as Reaction Wheel Assembly, Magnetic Torque Assembly, Dual Thruster Module, Solar array Drive, Three Axis Magnetometer, Conical Earth Sensor, Fine Sun Sensor Assembly, Coarse Sun Sensor Assembly, Gyro Reference Assembly and so on. For KOMPSA T satellite it has been considered using the Magnetic Torquer (MTQ) generating the magnetic dipole moment. In general, the magnetic dipole moment for satellite attitude control system is used for dumping out the excessive reaction wheel momentum so that the reaction wheel speed is not saturated. The objective of this study is to analyze the magnetic field characteristics generated by the Magnetic Torquer using the Maxwell 2D Field Simulator software. Currently, the developing model (DM) of the MTQ is being developed and manufactured at a company under the supervision of KARL MTQ is an electromagnet consisting of a ferromagnetic cylindrical core on which an excitation coil is wound. A current is passed through the coil to produce a dipole momentum in the ferromagnetic core. The configuration of the MTQ will be introduced in the presentation. The 2 dimensional model of the MTQ is drawn as axisymmetric models in RZ plane, and each corresponding material is assigned to the each MTQ object, the core, coil, and background. After the boundary conditions, current sources, and solution parameters are set up, the magnetic field intensities, directions, and other values specified by users can be calculated by using the finite element analysis. The theoretical magnetic field quantities obtained by the Maxwell 2D Simulator can be used for the basis of the development of the MTQ.

  • PDF

A Dual Micro Gas Sensor Array with Nano Sized $SnO_2$ Thin Film (나노 박막을 이용한 듀얼 $SnO_2$ 마이크로 가스센서 어레이)

  • Chung Wan-Young
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.9
    • /
    • pp.1641-1647
    • /
    • 2006
  • A dual micro gas sensor way for detecting reducing gas and bad order was fabricated using nano sized $SnO_2$ thin film fabrication method. To make nano-sized thin gas sensitive $SnO_2$ thin rilm, thin tin metal layer $2500{\AA}$ thick was oxidized between 600 and $800^{\circ}C$ by thermal oxidation. The gas sensing layers such as $SnO_2,\;SnO_2(+Pt)\;and\;SnO_2(+CuO)$ were patterned by metal shadow mask for simple fabrication process on the silicon substrate. The micro gas sensors with $SnO_2(Pt)$ and $SnO_2(+CuO)$ showed good selectivity to CO gas among reducing gases and good sensitivity to $H_2S$ that is main component of bad odor, separately.

Some case histories to detect underwater buried objects by electrical and magnetic methods (수중 매장물 조사에 응용되는 전기 및 자기 탐사사례)

  • JUNG Hyun Key;Park Yeong-Sue;Lim Mutaek;Rim Hyoungrae
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.118-137
    • /
    • 2004
  • Recently underwater geophysical problems for historical relics or UXO's are raised frequently. This study includes the applicabilities and limitations of the recent underwater metal detector and domestic case stories for underwater survey by electrical and magnetic method. Direct or indirect case stories are electrical and vertical magnetic gradiometry surveys beneath Han-river bottom for planning subway tunnel, electrical exploration on lake-bottom, electrical exploration on the tidal flats using high-power transmitter, and borehole three-component magnetic and electromagnetic surveys for detecting the undersea objects. A design of potable real-time, high-speed measurement system using multi-channel array sensors is also introduced here. Further study will be focussed on practical field applications of the fast water-bottom scanning system which is lately required by actual field.

  • PDF

Development of Diode Based High Energy X-ray Spatial Dose Distribution Measuring Device

  • Lee, Jeonghee;Kim, Ikhyun;Park, Jong-Won;Lim, Yong-Kon;Moon, Myungkook;Lee, Sangheon;Lim, Chang Hwy
    • Journal of Radiation Protection and Research
    • /
    • v.43 no.3
    • /
    • pp.97-106
    • /
    • 2018
  • Background: A cargo container scanner using a high-energy X-ray generates a fan beam X-ray to acquire a transmitted image. Because the generated X-rays by LINAC may affect the image quality and radiation protection of the system, it is necessary to acquire accurate information about the generated X-ray beam distribution. In this paper, a diode-based multi-channel spatial dose measuring device for measuring the X-ray dose distribution developed for measuring the high energy X-ray beam distribution of the container scanner is described. Materials and Methods: The developed high-energy X-ray spatial dose distribution measuring device can measure the spatial distribution of X-rays using 128 diode-based X-ray sensors. And precise measurement of the beam distribution is possible through automatic positioning in the vertical and horizontal directions. The response characteristics of the measurement system were evaluated by comparing the signal gain difference of each pixel, response linearity according to X-ray incident dose change, evaluation of resolution, and measurement of two-dimensional spatial beam distribution. Results and Discussion: As a result, it was found that the difference between the maximum value and the minimum value of the response signal according to the incident position showed a difference of about 10%, and the response signal was linearly increased. And it has been confirmed that high-resolution and two-dimensional measurements are possible. Conclusion: The developed X-ray spatial dose measuring device was evaluated as suitable for dose measurement of high energy X-ray through confirmation of linearity of response signal, spatial uniformity, high resolution measuring ability and ability to measure spatial dose. We will perform precise measurement of the X-ray beamline in the container scanning system using the X-ray spatial dose distribution measuring device developed through this research.

Development and Evaluation of Self-powered Energy Harvester in Wireless Sensor Node for Diagnosis of Electric Power System (전력계통 구조물의 상태진단용 자가발전 무선 센서 노드 개발 및 평가)

  • Kim, Chang Il;Jeong, Young-Hun;Yun, Ji Sun;Hong, Youn Woo;Jang, Yong-Ho;Choi, Beom-Jin;Park, Shin-Seo;Son, Chun Myung;Seo, Duck Ki;Paik, Jong Hoo
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.5
    • /
    • pp.371-376
    • /
    • 2016
  • A self-powered piezoelectric energy harvester was developed for the application in wireless sensor node. The energy harvester was evaluated with power generation characteristics for the wireless sensor node for structural diagnosis of the electric power system. The self-powered wireless sensor node was set to measure temperature, vibration frequency of the electric power system. A piezoelectric harvester composed of 7 uni-morph cantilevers (functionalized as 6 generators and 1 vibration sensor) was connected to be an array and revealed to produce significantly high output power of approximately 10 mW at 120 Hz under 3.4 g((1 g = $9.8m/sec^2$). The wireless sensor node could work as the electric power generated by the developed piezoelectric harvester.