• 제목/요약/키워드: array sensors

검색결과 478건 처리시간 0.03초

Infusion Pump용 Drop Sensor 개발에 관한 연구

  • 이종실;권장우;이응혁;박정선;구자일;홍승홍
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1995년도 추계학술대회
    • /
    • pp.18-21
    • /
    • 1995
  • When we inject drugstuffs to a patient for a long time, it is important to control proper injection amount and flow rate. Since inproper injection amount and a flow rate would cause bad a recovery a patient, the relience of sensors which detect injection amount is an important factor for whole injection systems' performance. In this research, we've compared the suitability of three sensors for injection pump monitoring system. The three types of sensors, piezo film sensor, photo transistor made up with three transmitting photodiodes and receving photodiode, and photo array, were selected for comparing. Using suggested data processing technique and photo amy sensors, we could minimize the effect of interference, disturbance, illumanation change, and sensitivity change caused by sensor's position. According to the experiments, the photo amy showed the higher reliance than any other the three types of sensors. The developed systems could be the foundation of beginning home production of infusion pump system and available for the base model of whole monitoring and control systems.

  • PDF

전자코 시스템을 위한 IEEE 1451.4 TEDS의 새로운 표준화 방안 (The New Way to Standardize IEEE 1451.4 TEDS for Electronic Nose System)

  • 김정도;김동진;정영창;정우석;변형기
    • 전자공학회논문지SC
    • /
    • 제43권1호
    • /
    • pp.21-30
    • /
    • 2006
  • IEEE 1451.4는 센서 및 액츄에이터를 위한 스마트트랜스듀서의 연결 표준안으로 정의되었다. 이 표준은 아날로그 트랜스듀서의 정보를 디지털 형태로 전송한다 이 디지털 형태의 정보를 TEDS(transducer electronic data sheet)라고 부른다. IEEE 1451.4 TEDS는 전자코 시스템에서의 어레이 센서에 대해서는 이용하기가 어렵다. 본 논문은 전자코 시스템에서 센서 인터페이스의 대한 표준화에 대해 분석해보고 새로운 방안을 제안한다.

Fabrication and statistical characterization of Nb SQUID sensors for multichannel SQUID system

  • Kim, B.K.;Yu, K.K.;Kim, J.M.;Kwon, H.;Lee, S.K.;Lee, Y.H.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제22권4호
    • /
    • pp.62-66
    • /
    • 2020
  • We fabricated superconducting quantum interference devices (SQUIDs) based on Nb Josephson junctions, and characterized the key parameters of the SQUIDs. The SQUIDs are double relaxation oscillation SQUIDs (DROSs) having larger flux-to-voltage transfer coefficient than the standard DC-SQUIDs. SQUID sensors were fabricated by using Nb junction technology consisted of a DC magnetron sputtering and a conventional photolithography process. In multichannel SQUID systems for whole-head magnetoencephalography measurement with a helmet-type SQUID array, we need about 336 SQUID sensors for each system. In this paper, we fabricated a few hundred SQUID sensors, measured the critical current, flux modulation voltage and decided if each tested SQUID can be used for the multichannel systems. As the criterion for the acceptance of the sensors, we chose the critical current and amplitude of the modulation voltage to be 8 ㎂ and 80 ㎶, respectively. The average critical current of the SQUIDs was 10.58 ㎂. The typical flux noise of the SQUIDs with input coil shorted was 2 μΦ0/√Hz at white region.

윤활유 물성 측정을 위한 유전상수 센서 개발 (Development of Dielectric Constant Sensor for Measurementof Lubricant Properties)

  • 홍성호;강문식
    • Tribology and Lubricants
    • /
    • 제37권6호
    • /
    • pp.203-207
    • /
    • 2021
  • This study presents the development of dielectric constant sensors to measure lubricant properties. The lubricant oil sensor is used to measure oil properties and machine conditions. Various condition monitoring methods are applied to diagnose machine conditions. Machine condition monitoring using oil sensors has advantage over other machine condition monitoring methods. The fault conditions can be noticed at the early stages by the detection of wear particles using oil sensors. Therefore, it provides an early warning in the failure procedure. A variety of oil sensors are applied to check the machine condition. Among all oil sensors, only one sensor can measure the tendency of several properties such as acidity and water content. A dielectric constant sensor is also used to measure various oil properties; therefore, it is very useful. The dielectric constant is the ratio of the capacitance of a capacitor using that material as a dielectric to that of a similar capacitor using vacuum as its dielectric. The dielectric constant has an effect on water content, contaminants, base oil, additive, and so forth. In this study, the dielectric constant sensor is fabricated using MEMS process. In the fabrication process, the shape, gap of the electrode array, and thickness of the insulation material are considered to improve the sensitivity of the sensor.

Development of Intelligent Mobile Robot with electronic nose

  • Byun, Hyung-Gi;Ham, Yu-Kyung;Kim, Jung-Do;Park, Ji-Hyeok;Shon, Won-Ryul
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.137.2-137
    • /
    • 2001
  • We have been developed an intelligent mobile robot with an artificial olfactory function to recognize odours and to track odour source location. This mobile robot also has been installed an engine for speech recognition and synthesis, and is controlled by wireless communication. An artificial olfactory system based on array of 7 gas sensors has been installed in the mobile robot for odour recognition, and 11 gas sensors also are located in the bottom of robot to track odour sources. 3 optical sensors are also included in the intelligent mobile robot, which is driven by 2 D.C. motors, for clash avoidance in a way of direction toward an odour source. Throughout the experimental trails, it is confirmed that the intelligent mobile robot is capable of not only the odour recognition using artificial neural network algorithm, but also the tracking odour source using the step-by-step approach method ...

  • PDF

마이크로채널에서의 국소 열전달 측정 (Local heat transfer measurement inside microchannel)

  • 조대관;이준식
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1902-1907
    • /
    • 2008
  • The current work presents a design and fabrication technique for a microchannel system to measure the local temperature distribution inside microchannel. This micro channel system fabricated by MEMS technique is integrated with a heater and an array of temperature sensors so that detailed heat transfer phenomena inside micro-scale channel can be studied. Materials widely used in semiconductor process were selected to fabricate a heater and temperature sensors on a silicon wafer. On these heater and sensors a channel wall was fabricated with SU-8. The friction constant and the local Nusselt number distribution measured for the deionized water flow in the microchannel is presented.

  • PDF

초음파 센서와 신경훼로망을 이용한 물체 인식과 복원 (Object Recognition and Restoration Using Ultrasound Sensors and Neural Networks)

  • 추승원;이기성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 추계학술대회 논문집 학회본부
    • /
    • pp.349-352
    • /
    • 1994
  • An object recognition and restoration using ultrasound sensors and neural networks are presented. The planar arrangement of the sensor is used to reduce the interference effects between sensors. The SOFM(Self-Organizing Feature Map) Neural Network and SCL(Simple Competitive Learning) method are learned with the acquired data. Lab experiments were performed that the object can be recognized ed the resolutions of the object can be enhanced by using the small number of the ultrasound array and neural networks.

  • PDF

A Study on the Interior Orientation for Various Image Formation Sensors

  • Lee, Suk-Kun;Shin, Sung-Woong
    • Korean Journal of Geomatics
    • /
    • 제4권1호
    • /
    • pp.23-30
    • /
    • 2004
  • This study aims to establish interior orientation for various types of sensors including frame cameras, panoramic cameras, line cameras, and whisk-broom scanners. To do so, this study suggests the classification of components of interior orientation of which elements are different according to the sensors. This is entailed by incorporation of sensor characteristics into mathematical models of interior orientation parameters are suggested for being used as guidelines in recovering systematic distortions. Finally, the potential errors resulted from the assumption of regarding sensor model of whisk-broom scanner model as that of push-broom scanner are discussed.

  • PDF

Intelligent Electronic Nose System for Detection of VOCs in Exhaled Breath

  • Byun, Hyung-Gi;Yu, Joon-Bu
    • 센서학회지
    • /
    • 제28권1호
    • /
    • pp.7-12
    • /
    • 2019
  • Significant progress has been made recently in detection of highly sensitive volatile organic compounds (VOCs) using chemical sensors. Combined with the progress in design of micro sensors array and electronic nose systems, these advances enable new applications for detection of extremely low concentrations of breath-related VOCs. State of the art detection technology in turn enables commercial sensor systems for health care applications, with high detection sensitivity and small size, weight and power consumption characteristics. We have been developing an intelligent electronic nose system for detection of VOCs for healthcare breath analysis applications. This paper reviews our contribution to monitoring of respiratory diseases and to diabetic monitoring using an intelligent electronic nose system for detection of low concentration VOCs using breath analysis techniques.

다중 거리 센서를 사용한 강의용 광역 마이크 시스템 (Wide-range Lecturing Microphone System using Multiple Range Sensor)

  • Oh, Woojin
    • 한국정보통신학회논문지
    • /
    • 제26권5호
    • /
    • pp.808-811
    • /
    • 2022
  • In this paper, a wide-range microphone system for lectures using dual 3D sensors is proposed. A previous work using a single sensor had lowering the detecting threshold to support wide-area. However it was found that an error occurred when lecturer wears clothes with low reflectivity or has small body size. When multiple sensors are used to expand the coverage it could be cause various problems. Each sensor could show different distance to the same target. We derive the rotation angle and and compensate for lecturing microphone system using sensors on the line. The proposed method shows a little improvement in performance by about 1dB compared to the previous works but the performance is uniform in all areas regardless of reflectivity.