• Title/Summary/Keyword: arrangements

Search Result 1,212, Processing Time 0.024 seconds

Traditional Korean landscape garden with special attention (역사적 문화환경의 창조 -고대정원문화를 중심으로-)

  • 민경현
    • Journal of the Korean Professional Engineers Association
    • /
    • v.18 no.2
    • /
    • pp.54-65
    • /
    • 1985
  • Korean Landscape Garden may be described according to its stage of development. In the primitive agricultural era, the garden was preceded by vegetable yards and at this time rock arranging (Soo-Sok garden) was initiated together with the megalithis culture of dolmens, heavenly altars and tumuli. In the early Three Kingdom period palace gardens were built on a grand scale and toward the end of fourth century temple garden were introduced along with Buddhism. These gardens evolved to the flourishment of "HWAGE"(terraced gardens) rock arrangements of ZEN, early KOR-YO period. Especially since the middle of KOR-Yo period the "IM-CHUN"(forest and pond) garden became popular, while during Cho-Son period "HWAGE" in the back yard, pond and pool garden and "IM-CHUN" style country villa became fashionable. The Korea traditional Landscape garde may be characterized that first it is a nature Landscape style, which makes the maximum accomodation with the surrounding nature. Secondly, the Korean garden is built creatively by utilizing the elements of its climate and topography, Kogu-Ryo, Paik-Je great-Kaya and Sil-Ra had developed original a castle town plans and beautiful gardens rock arrangements which precede the equivalent style of China and set the prototype for Japan. The Landscape art of waterfalls and rock arrangements at An-Ap-Chi garden of 7th century has no equals in China and set the origin of pond style of Japanese garden.

  • PDF

Diagonal bracing of steel frames with multi-cable arrangements

  • Husem, Metin;Demir, Serhat;Park, Hong G.;Cosgun, Suleyman I.
    • Structural Engineering and Mechanics
    • /
    • v.59 no.6
    • /
    • pp.1121-1137
    • /
    • 2016
  • A large number of structure in the world were build with poor seismic details, with or without any lateral load resisting system like concentrically braced frames and steel plate shear walls. These structures can reveal deteriorating hysteretic behaviors with stiffness and strength degradation. Therefore, seismic retrofitting of such structures for drift control has vital importance. In this study a retrofit methodology has been developed, which involves diagonal bracing of steel frames with different cable arrangements. In the experimental and numerical program 5 different lateral load resisting system were tested and results compared with each other. The results indicated that multi-cable arrangements suggested in this study showed stable ductile behavior without any sudden decrease in strength. Due to the usage of more than one diagonal cable, fracture of any cable did not significantly affect the overall strength and deformation capacity of the system. In cable braced systems damages concentrated in the boundary zones of the cables and beams. That is why boundary zone must have enough stiffness and strength to resist tension field action of cables.

Characteristics of Flow over a Pair of Circular Cylinders in Side-by-Side Arrangements (나란히 배열된 한 쌍의 원형실린더를 지나는 유동의 특성)

  • Kang, Sang-Mo
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1754-1759
    • /
    • 2003
  • Two-dimensional flow over a pair of circular cylinders in side-by-side arrangements at low Reynolds numbers has been numerically investigated in this study. Numerical simulations are performed, using the immersed boundary method, in the ranges of $40{\leq}Re{\leq}160$ and $g^{\ast}<5$, where Re and $g^{\ast}$ are, respectively, the Reynolds number and the spacing between the two cylinder surfaces divided by the cylinder diameter. Results show that total six kinds of wake patterns are observed over the ranges: antiphase-synchronized, inphase-synchronized, flip-flopping, single bluff-body, deflected, and steady wake patterns. It is found that the characteristics of the flow significantly depends both on the Reynolds number and gap spacing, with the latter much stronger than the former. Instantaneous flow fields, time traces, flow statistics and so on are presented to identify the wake patterns and then to understand the underlying mechanism. It is remarkable that, for the deflected wake pattern, the gap flow is deflected invariably to the cylinder of higher drag coefficient and the deflection way does not change at all. Moreover, the bifurcation phenomena where either of two wake patterns can occur are found at certain flow conditions.

  • PDF

Study on Optimal Arrangements of Laser Beams in Tunable Diode Laser Absorption Spectroscopy Based Tomography (TDLAST) (레이저흡수분광 토모그래피법에서의 레이저빔의 최적 배치에 관한 연구)

  • KIM, KYUNGWON;YOON, DONGIK;CHOI, DOOWON;CHO, GYEONGRAE;DOH, DEOGHEE
    • Journal of Hydrogen and New Energy
    • /
    • v.28 no.6
    • /
    • pp.729-737
    • /
    • 2017
  • The measurement accuracy of Tunable Diode Laser Absorption Spectroscopy based Tomography (TDLAST) for the temperature and concentration fields are dependant upon the arrangement method of the used laser beams. This paper reports on the optimization of laser beam arrangements using phantom data. It has been verified that the measurement error of the TDLAST decreased with increase of laser beam numbers. Further, it has been confirmed that perpendicular arrangements between the horizontal and the vertical laser beams without additional diagonal laser beams shows the minimum measurement errors.

Analysis of Convective Heat Transfer Characteristics for the Compact Heat Exchanger with Flat Tubes and Plate Fins Having a Non-symmetric Staggered Arrangements (비대칭 엇갈림 배열로 구성된 납작관-평판휜 형상의 밀집형 열교환기에 대한 대류열전달 특성 해석)

  • Moh, Jeong-Hah;Lee, Sang-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.5
    • /
    • pp.318-325
    • /
    • 2009
  • Numerical analysis has been carried out to investigate air-side convective heat transfer characteristics in compact heat exchanger with flat tubes and continuous plate fins having a symmetric and non-symm etric staggered arrangements. Simulation results such as air velocity and temperature distributions are presented, and heat transfer coefficients are compared with previous experimental results. In order to investigate the flow and heat transfer features by periodic boundary conditions, the three blocks were used. Predicted heat transfer coefficients between the three blocks are similar while there are relatively differences, compared with the experimental data. From the calculated results a correlation for Colburn j factor in the compact heat exchanger system is suggested. The predicted results in this study can be applied to the optimal design of air conditioning system.

Factors associated with Life Satisfaction among Older Adults in Korea according to Living Arrangements (거주형태에 따른 한국 노인의 삶의 만족도 관련 요인)

  • Lee, Si Eun
    • Korean Journal of Adult Nursing
    • /
    • v.28 no.6
    • /
    • pp.659-668
    • /
    • 2016
  • Purpose: This study utilized secondary data and investigated the factors associated with life satisfaction by living arrangements among community-dwelling adults aged 65 years or older in Korea. Methods: A total of 2,134 participants were selected from the 2014 Korean Longitudinal Study of Aging (KLoSA). Univariable and multivariable logistic regression were used for data analysis. Results: The significant factors associated with life satisfaction in older adults living with others were education level (odds ratio [OR] 1.73, 95% confidence interval [CI] 1.41~2.11), place of residence in medium-size city (OR 1.57, 95% CI 1.25~1.97), place of residence in rural town(OR 1.52, 95% CI 1.19~1.95), depression (OR 2.99, 95% CI 2.43~3.68), frequency of contact with neighbors (OR 1.39, 95% CI 1.10~1.76), and social participation (OR 1.48, 95% CI 1.14~1.93). In contrast, factors associated with life satisfaction among older adults living alone were education level (OR 1.93, 95% CI 1.15~3.24) and depression (OR 2.49, 95% CI 1.48~4.19). Conclusion: These findings indicated that nursing interventions for improving life satisfaction among older adults should take into account their specific living arrangements.

A Study on the Establishment of Guidances for Natural Stone Arrangements (자연석 사용 개선을 위한 설계 및 시공 기준 설정에 관한 연구)

  • 구본학;김용규;안동만
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.27 no.4
    • /
    • pp.94-100
    • /
    • 1999
  • Stone is one of the oldest material for construction and artistic works. This study investigates the current use of stones in landscape constructional works, and the design criteria to advance the arts of natural stone arrangements. Thirty four experts and thirty two others were surveyed with various photos of simulated construction works of natural stone arrangements fond improved design guidelines. Major findings are as follows: -The payment for the use of stones ranges approximately 5 to 10% of total cost of landscape constructional works. More stones may be used when better retailing system is introduced, working skill is standardized, and more of the substitute natural stones made of blasted rocks are provided and the cost goes down. -Preferences showed little difference for the mixed use of different sizes, colors and shapes of stones, and for the use of similar ones, in the construction of walls. This does not match with the current design guidelines. -Arranging three stones, which symbolizes heaven, earth, and human being, was the most preferred. As the supply of natural stones is limited and more substitute stones are used, it its needed to establish guidelines for the production of substitute stones. -Grasses are much more preferred between pavement stones than mortars. -In current practices, top of piled up natural stones is usually arranged level. More freely curved top lines are preferred to straight line.

  • PDF

Numerical Analysis and Measurement of Magnetization Loss in BSCCO Multi-stacked Conductor According to Stacking Geometry (적층 배열형상에 따른 BSCCO 적층선재의 자화손실 특성 수치해석 및 측정)

  • Park, Myung-Jin;Lim, Hyoung-Woo;Lee, Kwang-Youn;Cha, Guee-Soo;Lee, Ji-Kwang
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.2
    • /
    • pp.83-88
    • /
    • 2006
  • AC loss is one of the main research area in AC power application using high temperature superconductor(HTS), such as HTS transformer, HTS current limiter and HTS cable, because it is closely related to efficiency, economic estimation and design of power device. A lot of research for various arrangements of HTS tapes have been performed to increase a capacity of transport current because single HTS tape can not satisfy the demanded current capacity in HTS power application. In this paper, we studied magnetization loss by different several arrangements of BSCCO tapes such as Edge-to-Edge type, Face-to-Face type and Matrix type through numerical analysis by 2D-FEM and measurement. As a result, we got the result that the magnetization loss of Face-to-Face type arrangements was lower than those of other arrangement types under the conditions of the same stacking number. We think that the result was due to shield effect by demagnetization of adjacent HTS tapes which are located face to face.

Pressure Drop Distributions in Rotating Channels with Turning Region and Angled Ribs (I) - Cross Rib Arrangements - (각도요철 및 곡관부를 가진 회전덕트 내 압력강하 분포 (I) - 엇갈린 요철 배열 -)

  • Kim, Kyung-Min;Park, Suk-Hwan;Lee, Dong-Hyun;Cho, Hyung-Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.9 s.252
    • /
    • pp.873-881
    • /
    • 2006
  • The present study investigates the pressure drop characteristics in rotating two-pass ducts. The duct has an aspect ratio (W/H) of 0.5 and a hydraulic diameter $(D_h)$ of 26.67mm. Rib turbulators are attached crossly in the four different arrangements on the leading and trailing surfaces of the test ducts. The ribs have a rectangular cross section of $2mm(e){\times}3mm(w)$ and an attack angle of $70^{\circ}C$. The pitch-to-rib height ratio (pie) is 7.5, and the rib height-to-hydraulic diameter ratio $(e/D_h)$ is 0.075. The results show that the highest pressure drop among each region appears in the turning region for the stationary case, but appears in the upstream region of the second pass for the rotating case. Effects of cross rib arrangements are almost the same in the first pass for the stationary and rotating cases. In the second pass, however, heat transfer and pressure drop are high for the cases with cross NN or PP type ribs in the stationary ducts. In the rotating ducts, they are high for the cases with cross NP or PP type ribs.

Pressure Drop Distributions in Rotating Channels with Turning Region and Angled Ribs (II) - Parallel Rib Arrangements - (각도요철 및 곡관부를 가진 회전덕트 내 압력강하 분포 (II) - 평행한 요철 배열 -)

  • Kim, Kyung-Min;Park, Suk-Hwan;Lee, Dong-Hyun;Cho, Hyung-Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.9 s.252
    • /
    • pp.882-890
    • /
    • 2006
  • The present study investigates the pressure drop characteristics in rotating two-pass ducts. The duct has an aspect ratio (W/H) of 0.5 and a hydraulic diameter $(D_h)$ of 26.67mm. Rib turbulators are attached parallel in the four different arrangements on the leading and trailing surfaces of the test ducts. The ribs have a rectangular cross section of $2m(e){\times}3mm(w)$ and an attack angle of $70^{\circ}C$. The pitch-to-rib height ratio (p/e) is 7.5, and the rib height-to-hydraulic diameter ratio $(e/D_h)$ is 0.075. The results show that the highest pressure drop among each region appears in the turning region for the stationary case, but appears in the upstream region of the second pass for the rotating case. Effects of parallel rib arrangements are almost the same in the first pass for the stationary and rotating cases. In the second pass, however, heat transfer and pressure drop are high for the cases with parallel NN or PP type ribs in the stationary ducts. In the rotating ducts, they are high for the cases with parallel NN or PN type ribs.