• 제목/요약/키워드: arm CT

검색결과 67건 처리시간 0.026초

관골궁 골절의 정복시 수술 중 C-Arm 사용의 유용성: 증례보고 (The Avalibility of C-Arm in Reduction of Zygomatic Arch Fracture Intraoperatively: Case Report)

  • 서미현;천강용;윤준용;유충규;이은경;이원덕;서제덕
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제32권4호
    • /
    • pp.359-362
    • /
    • 2010
  • The zygoma is second most commonly vulnerable facial bone in fracture, in number only by nasal fractures. It is difficult to evaluate reduction state intraoperatively, because almost surgeons reduce the fractured zygoma by blind method. We suggest the use of orthopedic C-arm intraoperatively. We use plain radiography, CT to evaluate preoperative state. Gilles approach or intraoral approach were used to reduce the fractured zygomatic arch. The C-arm was positioned at chin area, used to evaluate reduction intraoperatively. We got postoperative image by CT or submento-vertex view. There are variable methods to evaluate reduction intraoperatively: palpation, ultrasonography, CT, plain films. C-arm is considered superior diagnostic tool to other methods. The use of intraoperative C-arm was very efficient, it could bring better results.

전신 PET/CT 검사에서 팔의 위치에 따른 감약 정도와 SUV 변화 평가 (The Evaluation of Attenuation Difference and SUV According to Arm Position in Whole Body PET/CT)

  • 곽인석;이혁;최성욱;석재동
    • 핵의학기술
    • /
    • 제14권2호
    • /
    • pp.21-25
    • /
    • 2010
  • PET/CT검사에 있어서 CT는 해부학적인 정보를 제공할 뿐 아니라 PET영상에 대한 감약 정보를 제공하는 역할을 하고 있다. CT의 감약차를 이용하는 것으로서 검사 부위에 존재하는 여러 가지 변수에 의해 그 정도가 달라질 수 있다. 이것은 현재 본 원에서 PET/CT검사 시에 팔을 몸 옆에 두고 검사하는 것에도 적용할 수 있으며, 이에 본 논문에서는 일부 타 병원에서 시행하고 있는 팔을 머리 위로 올리고 검사하는 방법과 함께 CT값의 변화에 따른 표준섭취계수의 변화를 비교 연구했다. NEMA 1994 PET 모형의 삽입체와 모형의 부피를 고려하여 4:1의 비율로 $^{18}F$-FDG를 주입하였다. 먼저 테플론 삽입체 두 개를 NEMA 1994 PET 모형의 양 옆에 고정시켜 팔을 내리고 있는 상태를 가정하여 영상을 얻었으며 테플론 삽입체를 제거하여 팔을 머리 위로 올린 상태를 가정하여 영상을 얻었다. 앞의 과정을 거쳐 얻은 영상을 재구성 하여 Volume Viewer를 이용해 한 영상면 당 5개의 관심 체적을 설정했고 각 측정값을 평균하여 얻어낸 CT값과 표준섭취계수로 그 변화를 측정하였다. 측정된 값과 폐 관련 암환자의 간에 관심 영역을 설정하고 측정한 값을 비교하여 실제 임상 영상에서의 차이를 측정하였다. 모형 실험결과 테플론 삽입체를 부착하였을 때보다 테플론 삽입체를 부착하지 않았을 때 CT값이 -5.8 HU에서 0 HU으로 평균 5.8 HU 증가하였고 표준섭취계수는 24.64에서 24.29로 평균 0.35 감소하였다. 축방향 균일도는 0.064에서 0.052로 평균 0.012 감소하였다. 환자 실험결과 팔을 내리고 검사하였을 때보다 팔을 머리 위로 올리고 검사하였을 때 CT값은 54.1 HU에서 59.9 HU로 평균 5.8 HU 증가하였고 표준섭취계수는 2.02에서 1.85로 평균 0.17 감소하였다. 테플론 삽입물을 부착한 상태로 검사할 때 보다 테플론 삽입물을 부착하지 않은 상태로 검사할 때 CT값은 증가하고 표준섭취계수는 감소하는 양상을 보였다. 이러한 현상이 일어나는 이유는 감약의 정도와 표준섭취계수의 상관관계에서 찾을 수 있다. CT값이 증가할수록 감약 계수는 비례하여 증가하는데 이것은 결국 CT값이 증가될수록 감약이 증가된다고 볼 수 있다. 따라서 팔에 의해 감약이 과다하게 측정될 수 있으므로 결국 표준섭취계수의 증가로 이어진다고 판단된다. 하지만 그 값의 차이가 매우 적어 진단적으로 유의한 범위라고 볼 수 없다. 팔을 머리 위로 올리고 검사하는 자세가 어깨 및 팔에의 $^{18}F$-FDG섭취와 환자의 고통을 야기하게 된다는 점들을 종합하여 고려해 보았을 때, PET/CT검사 시에는 팔을 내리고 검사하는 것이 합리적이나, 환자의 상태 및 영상의 질적 측면을 고려하여 결정하여야 하겠다.

  • PDF

국한성병기 소세포폐암 환자에서 조기 혹은 지연 교대 방사선-항암제치료의 전향적 비교연구 (Randomized Trial of Early Versus Late Alternating Radiotherapy/ Chemotherapy in Limited-Disease Patients with Small Cell Lung Cancer)

  • 이창걸;김주항;김성규;김세규;김귀언;서창옥
    • Radiation Oncology Journal
    • /
    • 제20권2호
    • /
    • pp.116-122
    • /
    • 2002
  • 목적 : 국한성병기 소세포폐암의 교대 방사선-항암제 병행치료(alternating radio-chemotherapy)에서 방사선치료의 시기의 차이에 따른(조기 혹은 지연) 치료반응률, 생존율, 재발양상, 치료에 따른 부작용을 비교하기 위해 전향적 무작위 비교연구를 시행하였다. 대상 및 방법 : 1993년 8월부터 1996년 8월까지 국한성병기 소세포폐암으로 진단받은 환자들은 연세암센터에서 조기(early arm) 혹은 지연(delayed arm) 교대 방사선-항암제치료군으로 무작위 분류되었다. 총 56명의 환자 중 44명이 비교분석 되었다. 환자들의 특성은 양군간에 차이가 없었다. 교대 방사선-항암제치료는 항암제치료기간 중 방사선 치료를 쉬는 방법으로 교대로 쉬지 않고 치료를 하는 방법으로 조기방사선치료군(N=22)은 항암제 1차치료 후 방사선치료를 시작하였고 지연방사선치료군(N=22)은 3차 항암제치료후 방사선치료를 시작하였다. 방사선치료는 1.8 Gy/fr으로 54 Gy/30 fr을 조사하였고 항암제치료는 Ifosfamide $1.5\;g/m^2$, 정맥주사로 제1일에서 5일까지 투여하였고 Carboplatin AUC (area under the concentration-time eurve) 5/day, 정맥주사로 제 2일째 투여하였으며 4주 간격으로 총6회 시행하였다. 관해율은 방사선치료 종료 한달 뒤 판정하였고 부작용의 빈도와 정도는 RTOG 등급체계를, 생존율은 Kaplan-Meier 법을 사용하였고, 비교는 Log-rank test를 이용하였다. 결과 : 치료에 대한 반응률은 조기군 $86\%$, 지연군 $85\%$로 차이가 없었다. 전체환자의 2년 생존율은 $18.9\%$, 중앙생존기간 15개월이었다. 치료시기별 2년 생존율, 중앙생존기간은 조기군 $22.7\%$와 15개월, 지연군 $14.9\%$와 17개월로 통계적으로 유의한 차이가 없었다(p=0.47). 2년 무재발생존율은 조기군 $19.1\%$, 지연군 $19.6\%$로 차이가 없었다(p=0.52), 국소재발은 조기군 $43\%$, 지연군 $45\%$로 차이가 없었고, 원격전이는 조기군 $81\%$, 지연군 $70\%$으로 재발양상에서도 차이가 없었다. 첫 재발부위로 뇌전이는 조기군 $23\%$, 지연군 $35\%$로 차이가 없었다(p=0.51). 치료에 따른 부작용(RTOG 등급 $3\~4$)도 양군간에 차이가 없었다. 치료에 대한 순응도를 비교해볼 때 항암제치료를 6회 이상 시행받은 환자가 조기군 $82\%$, 지연군 $77\%$, 방사선치료를 45 Gy 이상 받은 환자가 조기군 $82\%$, 지연군 $91\%$로 양군간에 차이가 없었고 양군에서 대부분의 환자들은 치료에 잘 순응하였다. 결론 : 국한성병기 소세포폐암의 교대 방사선-항암제치료시 방사선치료를 조기 혹은 지연하여 시행하였을 때 치료 반응률, 생존율, 재발양상, 부작용에는 차이가 없었으며 교대 방사선-항암제치료에 대한 환자들의 순응도는 높았다.

복부/골반 CT 검사 시 팔의 위치에 따른 방사선 선량과 영상화질 비교 연구 (Study on Image Quality and Radiation Dose due to the Arm Position in the Abdomen/Pelvis CT)

  • 이종웅;원도연;정재은;김형균
    • 한국방사선학회논문지
    • /
    • 제9권6호
    • /
    • pp.337-342
    • /
    • 2015
  • 2013년도 1월부터 12월까지 1년간 복부/골반 추적 검사를 시행한 환자 중 1년간 2회 이상 검사한 환자 10명에 대해 팔의 위치에 따른 방사선 선량과 image quality를 후향적으로 분석하였다. 팔을 올리고 표준 자세로 검사한 그룹을 A, 팔을 내리고 검사한 그룹을 B로 분류하였다. 첫 번째 선량비교에서 A 그룹은 B 그룹에 비해 평균 mAs 량이 11.4 % 적게 조사되었으며 CTDI 값도 11.3 % 작게 나타났다. 두 번째 영상의 화질 비교를 위한 histogram은 A 그룹과 B 그룹 모두 max 값은 비슷하게 측정되었지만 mean 값과 SD 값에서 큰 차이를 나타내 B 그룹이 A 그룹에 비해 선량을 더 주었지만 팔의 위치에 따라 선량 부족 현상이 나타났다. 최적의 영상을 획득하기 위하여 복잡한 알고리즘의 개발과 고사양의 장비도입 이전에 CT 검사 시 검사자가 적극적으로 팔을 올려서 검사하는 노력만으로 적은 피폭선량과 양질의 의료영상을 환자에게 제공할 수 있을 것이다.

Computed Tomography Fluoroscopy-Guided Selective Nerve Root Block for Acute Cervical Disc Herniation

  • Eun, Sang-Soo;Chang, Won-Sok;Bae, Sang-Jin;Lee, Sang-Ho;Lee, Dong-Yeob
    • Journal of Korean Neurosurgical Society
    • /
    • 제48권5호
    • /
    • pp.419-422
    • /
    • 2010
  • Objective : To analyze the clinical outcomes of computed tomography (CT) fluoroscopy-guided selective neve root block (SNRB) for severe arm pain caused by acute cervical disc herniation. Methods : The authors analyzed the data obtained from 25 consecutive patients who underwent CT fluoroscopy-guided SNRB for severe arm pain, i.e., a visual analogue scale (VAS) score of 8 points or more, caused by acute soft cervical disc herniation. Patients with chronic arm pain, motor weakness, and/or hard disc herniation were excluded. Results : The series comprised 19 men and 6 women whose mean age was 48.1 years (range 35-72 years). The mean symptom duration was 17.5 days (range 4-56 days) and the treated level was at C5-6 in 13 patients, C6-7 in 9, and both C5-6 and C6-7 in 3. Twenty-three patients underwent SNRB in 1 session and 2 underwent the procedure in 2 sessions. No complications related to the procedures occurred. At a mean follow-up duration of 11.5 months (range 6-22 months), the mean VAS score and NDI significantly improved from 9 and 58.2 to 3.4 and 28.1, respectively. Eighteen out of 25 patients (72%) showed successful clinical results. Seven patients (28%) did not improve after the procedure, and 5 of these 7 underwent subsequent anterior cervical discectomy and fusion. Conclusion : CT fluoroscopy-guided SNRB may play a role as a primary conservative treatment for severe arm pain caused by acute cervical disc herniation.

3D CACT-assisted Radiofrequency Ablation Following Transarterial Chemoembolization for Hepatocellular Carcinoma: Early Experience

  • Jiao, De-Chao;Han, Xin-Wei;Wu, Gang;Ren, Jian-Zhuang
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권17호
    • /
    • pp.7897-7903
    • /
    • 2015
  • Background: To explored the value of 3D C-arm CT (CACT) guidance system in performing radiofrequency ablation (RFA) following transarterial chemoembolizationon (TACE) for hepatocellular carcinomas. Materials and Methods: RFA of hepatocellular carcinomas (HCC) were performed on 15 patients (21 lesions) with the assistance of CACT guidance system. Technical success, procedure time, complications and patient radiation exposure were investigated. The puncture performance level was evaluated on a five-point scale (5-1: excellent-poor). Complete ablation rate was evaluated after two months follow-up using enhanced CT scans. Results: The technical success rate of RFA procedure under CACT navigation system was 100 %. Mean total procedure time was $24.24{\pm}6.53min$, resulting in a mean effective exposure dose of $15.4{\pm}5.1mSv$. The mean puncture performance level rated for CACT guided RFA procedure was $4.87{\pm}0.35$. Complete ablation (CA) was achieved in 20 (95.2%) of the treated 21 tumors after the first RFA session. None of patients developed intra-procedural complications. Conclusions: 3D CACT guidance system enables reliable and efficient needle positioning by providing real-time intraoperative guidance for performing RFA on HCCs.

고주파요법이 부분비만치료에 미치는 영향 (Effects of High Frequency Therapy on Localized Obesity)

  • 신승우;최영민;심우진;이형철;김길수
    • 한방비만학회지
    • /
    • 제6권2호
    • /
    • pp.75-83
    • /
    • 2006
  • Objectives : This study was performed to identify the effects of high frequency therapy on localized obesity. Methods : This trial was carried out in 12 volunteers. Volunteers were divided into 3 groups; upper arm group (n=4), thigh group (n=4) and abdomen group (n=4) according to local obesity type. Body weight and body fat were measured by Inbody 720 and CT (Computed Tomography) immediately before and following high frequency therapy. Diathermy was performed twice a week for 4 weeks for a total of 8 treatments. Results : In the upper arm group, body weight, body fat mass, fat area by CT scan and circumference were increased after treatment but not significantly (p>0.05). In the thigh group, body weight, body fat mass and circumference were decreased and fat area by CT scan was increased but both not significantly (p>0.05). In the abdomen group, significant differences were not found despite decreases in body weight, body fat mass, visceral fat and subcutaneous fat after diathermy (p>0.05). Conclusions : There was no significant effects of high frequency therapy on localized obesity.

  • PDF

고선량률 근접 방사선 치료에서 기존의 필름 방법과 CT 재구성 방법의 비교 연구 (Comparison Study of Conventional Film-based and CT-reconstruction method in HDR Brachytherapy)

  • 장지나;이형구;윤세철;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제15권2호
    • /
    • pp.63-69
    • /
    • 2004
  • 고선량률 근접치료는 저선량률 근접치료와 비교하여 짧은 시간에 많은 선량이 조사되며, 치료를 위한 최적화가 물리적 요인, 방사선 파라미터, 최적화 알고리즘 같은 여러 복잡한 요인들과 연관되어 있으므로 정확한 선량 전달을 위해서는 정확한 검증 과정을 필요로 한다. 본 연구에서는 앞선 연구에서 제작하였던 선량 검증용 팬톰의 단점을 보완하고 CT나 MRI 시스템에서도 이용할 수 있는 구조를 추가시켜 고선량률 근접 치료의 위치 및 선량 검증을 위한 새로운 자궁경부암용 팬톰을 개발하였다. 또한, 개발된 팬톰을 이용하여 고선량률 근접치료에서의 기존의 필름에 기반한 orthogonal 방법의 위치 확인에 대한 점증을 수행하였다. 위치 확인에 대한 철증은 CT 시스템에서의 좌표를 비교, 분석함으로써 수행되었다. 제작된 팬톰은 자궁경부암 환자를 대상으로 환자의 해부학적 구조를 모사하여 제작하였기 때문에 방광과 직장을 모사한 구와 원기둥의 구조물을 포함하고 있으며, C-arm과 CT 영상을 정확하게 획득하기 위한 localizer를 포함하고 있다. 또한, C-arm 및 CT 좌표 비교 수행을 위하여 알고리즘에 기반한 재구성 프로그램을 직접 IDL 5.5를 이용, window 환경에서 개발하였다. 좌표 비교를 수행한 결과, CT의 좌표가 정확한 좌표라고 가정했을 때 필름에 기반한 방법은 모든 점에서 1.0 mm 이내에서 일치함을 확인할 수 있었다. 본 연구를 바탕으로 우리는 현재 사용하고 있는 Plato (Nucletron, Netherlands) 근접치료 기기의 위치 확인 알고리즘에 대한 검증을 자체적으로 수행할 수 있었다. 이번 연구에서 새롭게 제작된 팬톰과 소프트웨어는 근접치료의 Qual Assurance (OA) 분야에서 효율적이고 강력한 QA 도구로 자리 잡을 수 있을 것으로 기대된다.

  • PDF

융합영상(Fusion image)에서 움직임을 줄이기 위한 보정기구의 개발 (Development of Supplemental Equipment to Reduce Movement During Fusion Image Acquisition)

  • 조용귀;표성재;김봉수;신채호;조진우;김창호
    • 핵의학기술
    • /
    • 제17권2호
    • /
    • pp.84-89
    • /
    • 2013
  • PET-CT (Positron Emission Tomography-Computed Tomography)의 융합영상(Fusion image)에서 긴 영상 획득 시간에 의한 환자의 움직임은 융합영상에서 부적합한 결과로 나타나 영상의 질과 진단에 큰 영향을 준다. 의료장비 회사에서 제공하는 팔 지지대는 환자 자세에서의 편의성과 안전성을 고려하지 않아 PET/CT를 검사하는 동안 팔과 머리의 움직임 때문에 뇌기저부의 영상 결손이 생기고 머리의 좌우, 상하 움직임으로 인하여 재촬영이 빈번하다. 이에 우리는 두경부와 팔의 움직임을 최소화할 수 있는 환자보정기구를 개발하여 PET/CT 촬영 시 환자에게 편의성과 안전성을 제공하고 환자의 움직임으로 인한 재촬영을 줄이고자 한다. 2012년 6월부터 7월까지 PET Torso 검사를 위해 핵의학과에 내원하는 환자들 중 움직임에 불편함이 전혀 없는 환자 20명과 어깨 통증으로 팔을 올리기가 불편한 환자 20명을 대상으로 Patient Holding System (PHS)와 팔의 경사도($25^{\circ}$, $27^{\circ}$, $29^{\circ}$, $31^{\circ}$, $33^{\circ}$, $35^{\circ}$)를 변화시켜 가장 편안한 자세와 경사도를 선정 하였다. 또한 지지대 재질의 투과성에 대하여 유관업체의 검증을 하였고, 환자의 머리와 팔을 밴드(벨크로 형태)로 고정하여 이에 대한 편의성을 질의하였다. 그리고 움직임에 의한 재촬영 빈도를 알아보기 위해 2012년 1월부터 12월까지 PET Torso를 시행한 환자들 중 환자보정기구 사용 전/후 재촬영 여부를 분석하였다. 움직임에 불편이 전혀 없는 환자에서는 18명이 PHS와 팔의 각도가 $29^{\circ}$에서 가장 편안함을 느낀다고 답하였으며, 2명은 각각 $27^{\circ}$, $31^{\circ}$이라고 답하였다. 어깨 통증을 느끼는 환자에서는 15명이 $31^{\circ}$에서 가장 편안함을 느낀다고 답하였고, $33^{\circ}$에서 2명, $35^{\circ}$에서 3명이었다. 이를 위해 손잡이 부분이 상, 하 움직임이 가능하도록 제작하였다. 환자보정기구 재질의 투과성은 검증된 상태이며, 환자보정기구 자체의 움직임을 방지하기 위하여 PHS와 보정기구를 밴드(벨크로 형태)로 고정시켰다. 두경부의 움직임을 최소화할 수 있는 홈을 만들고 머리를 고정할 수 있게 고정밴드를 부착 하였고, 손목 및 전완과 상완의 움직임을 제한할 수 있는 고정밴드를 부착하여 팔의 흔들림으로 인한 움직임을 최소화 하였다. PET Torso 촬영 시 움직임에 의한 재촬영 빈도는 환자고정기구 사용 전 10.56% (191건/1,808명), 사용 후 2.77% (48 건/1,732명)로 7.79%의 발생 빈도를 줄일 수 있었다. 최근 의료 환경의 변화와 혁신으로 고가의 영상검사가 늘어남에 따라 고객이 요구하는 차별화된 서비스 제공은 필수적이다. 따라서 PET/CT를 검사하는 동안 환자의 편안함과 안전성을 확보하기 위해 인체공학적인 환자보정기구를 제공하여야 한다. 따라서 본 연구를 통해 PET Torso 검사 시 환자의 체형과 상황에 따라 인체공학적 경사도를 상, 하 조절할 수 있는 환자보정기구를 제작하였으며, 팔의 움직임에 의한 뇌기저부의 영상결손을 줄이고 머리의 움직임으로 인한 재촬영을 줄일 수 있었다.

  • PDF