• Title/Summary/Keyword: arm 2

Search Result 2,203, Processing Time 0.028 seconds

A Study on Clothing Adaptability to Arm Movements and the Aesthetic Evaluation According to the Armhole Depth of Bodice Pattern (진동깊이에 따른 길원형의 동작 적합성 및 심미성에 관한 연구)

  • 허미옥;구미지;황진숙
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.24 no.2
    • /
    • pp.164-172
    • /
    • 2000
  • The purpose of this study was to investigate the most appropriate arm-hole depth in 9 positions of arm movements. This subjects were four females, college students aged 18 to 23 years old. The clothing size 55 was used for this study. In the experiments for the investigation of the arm-hole depth, the evaluations were performed for aesthetic view, clothing adaptability to arm movements, and quantity of materials pulled up by 9 movements of arm. The results of this study were as follows: 1) In the aesthetic evaluation, there were no significant differences in arm-hole depths. 2) In the evaluation of clothing adaptability to arm movements, the experiment clothes, in which-arm-hole depths were raised, had more positive evaluations especially with the increasing the angle of arm movements. 3) In the evaluation of clothing adaptability to each body areas, there were no significant differences in all body areas except upper arm circumference blade. 4) In the evaluation of quantity of materials pulled up by arm movements, the clothes of B/4-2 arm-hole depth had the least amount pulled up by arm movements, which showed the highest adaptability to arm movement.

  • PDF

Optimal Design and Simulation of SCARA Robot Arm (스카라 로봇 암의 최적화 설계 및 시뮬레이션)

  • Lee, Jong-Shin
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.6
    • /
    • pp.612-618
    • /
    • 2009
  • This study is concerned about the optimal design of the arm 1 and arm 2 in the SCARA robot. The mass and inertia moment of the arm I and arm 2 in a SCARA robot is greatly affected on the performance such as a cycle time, and torques loaded on $1^{st}$ axis and $2^{nd}$ axis. To reduce the mass and inertia moment, this study carried out optimal design by FEM analysis using parametric variables, which is a width, a height of the rib and a thickness of arm in the arm. The rib is adapted instead of reducing the thickness in the arm. And the simulation by computer was conducted on two given paths in X direction and Y direction. After optimal design, the result showed that maximum torque of $1^{st}$ axis and $2^{nd}$ axis reduced to maximum 9.5% on a given path.

Arm-up holder의 보조기구 제작에 따른 유용성 평가

  • 이현직;최병기;심재구;김종식;오동균;박영환
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.14 no.1
    • /
    • pp.85-88
    • /
    • 2002
  • I. 목적 : arm-up holder는 흉부 및 복부 질환 치료의 환자고정에 유용하게 사용하고 있으나 손잡이 부분과 어깨가 닿는 부분까지 거리 때문에 동일한 자세를 유지하는데 불편함이 있다. 특히 긴장을 많이 하거나 기력이 없는 환자는 방사선 치료 시 자세의 불안정으로 인하여 치료의 정확성이 떨어질 수 있다. 이에 본원에서는 현재 사용하고 있는 arm-up holder에 팔의 지지를 위한 보조기구를 제작하여 유용성을 평가하였다. II. 대상 및 방법 : 기존의 arm-up holder에 어깨받침대를 부착하여 개선된 arm-up holder를 제작하였다. 실험을 위하여 기존의 arm-up holder를 사용하는 환자그룹과 개선된 arm-up holder를 사용하는 그룹으로 구분하여 자세 변화를 평가하였다. 두 그룹의 환자를 대상으로 모의 치료를 실시한 후 치료실에서 L-gram 을 2회 씩 촬영하여 치료하고자 하는 portal film과 isocenter의 변화를 측정했다. 각 그룹 당 10명씩의 환자를 선정하여 반복 조사하였다. III. 결과 : 개선된 arm-up holder를 사용한 그룹의 isocenter 의 변화는 최대 2mm, 최소 0.5mm 평균 1.2mm 이다. 기존의 arm-up folder를 사용한 그룹과 비교하여 평균변화는 약 2배로 나라났고, 최대 변화는 2.5배의 오차범위가 측정되었다. IV. 결론 : 현재 사용하고 있는 arm-up holder는 흉부 및 복부의 사방향 방사선 치료 시 팔에 의한 방사선 감약을 예방할 수 있는 유용한 고정용구이다. 하지만 팔을 올리고 있는 자세는 환자에게 불편함을 야기 시키며 이로 인한 치료의 정확성을 감소시킬 수 있다. 따라서, 기존의 arm-up holder에 보조기구를 제작하여 사용함으로써 환자의 불편함을 개선하고, set-up 의 안정성과 재현성을 향상시킬 수 있었다.

  • PDF

Custom system design and verification using ARM Cortex-M0 DesignStart (ARM Cortex-M0 DesignStart를 활용한 커스텀 시스템 설계 및 검증)

  • Lee, Sungryoung;Yoo, Hoyoung
    • Journal of IKEEE
    • /
    • v.24 no.2
    • /
    • pp.486-491
    • /
    • 2020
  • ARM Cortex-M0 DesignStart provided by ARM is cost-free design development suit targeting for designing and prototyping SoC with Cortex-M0 core. In this paper, we presents a method how to implement a custom system design using ARM Cortex-M0 DesignStart. First, hardware elements for ARM Cortex-M0 DesginStart is analyzed focusing on bus and memory map, and next software toolchain is explained to clarify the translating process from high level language to binary machine language. As an example of the custom system, UART system operated with Cortex-M0 is designed and simulated.

An analysis of the effectiveness for an anti-ARM technique using decoy antennas (디코이 안테나를 이용한 ARM 방어 기술의 효과도 분석)

  • Lim, Joong-Soo;Chae, Gyoo-Soo;Kim, Min-Nyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.2
    • /
    • pp.491-496
    • /
    • 2010
  • This paper describes an analysis of the effectiveness for an anti-ARM technique to protect a radar system. We investigate the optimum deployment of decoy antennas which are widely using for anti-ARM and the electromagnetic field at the ARM receiver. To verify the effect of decoy antennas, we analyze the field intensity and phase at the receiver and develop a numerical simulation program using Matlab. We conduct an analysis of ARM attack in case of using multiple decoy antennas and these results can be used to decide the optimum positions of the decoys for anti-ARM.

Stress and Modal Analysis for the Rotor System of a Medical Centrifuge using Finite Element Method (유한요소법을 이용한 의료용 원심분리기 로터의 응력 및 고유치 해석)

  • Kim, Sung-Min;Yang, In-Chul;Kim, Do-Gyoon;Kim, Hak-Chul
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.6
    • /
    • pp.78-85
    • /
    • 2007
  • In this study, we performed finite element analysis for the design of a medical centrifuge and two-types of centrifuge were compared with each other. The types of centrifuge are 2-arm straight type and 3-arm type. Structural analysis was done with respect to the change of the rotational speed of the rotor of a centrifuge. When the rotor of centrifuge was rotated, the von Mises stress of 2-arm straight type-rotor was compared with the von Mises stress of 3-arm type. The margin of safety was estimated from the result. We found the critical speed of centrifuge from the campbell diagram by modal analysis.

A Study on the Sleeve Fitness According to Characteristics of Arm Types (팔 유형 특성에 따른 소매 적합성 연구)

  • 이정란
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.27 no.2
    • /
    • pp.219-228
    • /
    • 2003
  • The purpose of this study were to examine the characteristics of arm types proposed in the previous study and to present sleeve patterns according size and shape of 4 arm types. 31 direct and indirect items were measured. The subjects for this study were 132 females of twenties. The results were as follows. 1. All of the direct measurements showed significant difference by the arm types. especially at the front armhole part. Such a.: the items of arm gradients, armhole sizes belong to the indirect measurements made clear difference also. 2. By the discriminant analysis, 9 items including underarm length, front armhole girth, upper arm girth, degree of elbow point-wrist point discriminated arm type by the hit ratio of 90.4% Item related to shape of arm rather than size made a sharp distinction. 3. Through the examination of existing patterns and wearing tests on the subjects among 4 groups, sleeve patterns classified by the arm type were suggested.

Treatment Results of Preoperative Radiotherapy Alone vs. Preoperative Radiotherapy and Chemotherapy in Locally Advanced Rectal Cancer (국소진행된 직장암에서의 수술전 방사선치료 단독군과 방사선치료와 항암제 병용치료군의 치료성적)

  • Kim Jae Sung;Park Seoung Ho;Cho Moon June;Yoon Wan Hee;Bae Jin Sun;Jeong Hyun Yong;Song Kyu Sang
    • Radiation Oncology Journal
    • /
    • v.13 no.1
    • /
    • pp.33-40
    • /
    • 1995
  • Purpose : To assess the efficacy and toxicity of the preoperative radiotherapy with or without chemotherapy in locally advanced rectal cancer Methods : Forty three patients (clinically diagnosed stages above or equal to Astler-Coiler stage B2 without distant metastasis) were assigned to preoperative radiotherapy alone arm (n=16) or combined preoperative radiotherapy and chemotherapy arm (n=27). Preoperative radiotherapy of 4500 cGy to whole pel-vis +/-540 cGy boost to primary site and concurrent chemotherapy of 2 cycles of 5-FU (500 mg/$m^2$) and leucovorin (20 mg/$m^2$) were used. Fifteen patients of preoperative radiotherapy alone arm and 19 of combined arm received surgical resection after preoperative treatment. Results : During the preoperative treatment, no significant complication was developed in both groups. Pathologic results were as follows; complete remission 1, Bl 1, B2 6, C1 2, C2, 5 in preoperative radiotherapy alone arm and complete remission 2, Bl 8, B2 4, C2 3, D 2 in combined arm. Postoperative complications were delayed perineal wound healing in three patients, intestinal obstruction in three patients (one managed by conservative medical treatment, two by surgical treatment). Conclusion : The combined preoperative radiotherapy and chemotherapy arm was more effective in pathological response and lymph node negativity rate than the preoperative radiotherapy alone arm. Both the preoperative radiotherapy alone arm and the combined arm were generally well tolerated and did not result in an increased postoperative morbidity.

  • PDF

Ergonomic Studies of Arm Shapes and Sleeves : Arm length depending on Arm movements (상지 형태와 의복소매에 관한 인간 공학적 연구(제2보) - 동작에 의한 상지 길이 변화 -)

  • Jo, Gyeong-Ae
    • Journal of the Ergonomics Society of Korea
    • /
    • v.18 no.1
    • /
    • pp.91-108
    • /
    • 1999
  • In our previous work using a motion analyzer and 3-dimensional sonic digitizer, the arm shapes for 23 women in their early twenties were classified into three characteristic types. In order to design sleeves, suitable for arm movements for the three characteristic arm shapes, a relationship between arm length variation and shoulder/elbow angles has been investigated for four cases of arm movements (flexion, extension, adduction and abduction). Each arm movement can be characterized by the changes in shoulder angle and the changes in elbow angle at the maximal shoulder angle. In all the four cases of arm movements, the changes of shoulder length and cap height are largest at the maximal shoulder angle. These changes were little affected by changes in elbow angle. The changes in the lower arm length and the difference between cap height and upper arm length are the largest at the maximal elbow angle of the maximal shoulder angle. There is a linear relationship between cap height and shoulder angle during arm movements; thus, in designing sleeves the cap height can be determined from the regression of cap height vs. shoulder angle.

  • PDF

Design of Robot Rotation Arm with Parallel Motion in End Effector (말단 장치의 평면 유지가 가능한 로봇 회전 암의 설계)

  • Lee, Jong-Shin
    • The Journal of Korea Robotics Society
    • /
    • v.5 no.4
    • /
    • pp.359-366
    • /
    • 2010
  • This study proposes the design method for the robot rotation arm which the end effector that is connected in end of the arm keeps parallel motion even though the robot arm rotates. So far, most robot arm rotates together the end effector when the arm rotates. For this, this study proposes the mechanism that the arm is linked to each 4 parallel link so that rotation is possible by 4 pins, and the rotation arm connects 2 joints of diagonal line direction to a link in each 4 joint for rotation, and designs so that can change length of the link. For verification of design, this study targeted that develop the rotation arm for medical examination that use in ophthalmology. It is important that a medical robot offers comport to patient and design compactly so that medical examination and treatment space may can be defined enough. It is designed so that all drive elements may be positioned on interior of the arm and optimization of design for main parts was carried out in this study for this. The robot arm which is developed in this study manufactured to use by medical phoropter arm, and got good result by an experiment. The robot rotation arm which is proposed in this study is judged to contribute very effectively in case use of a medical robot arm for medical examination and treatment, also the robot arm which the end effector that is connected in the end of the arm needs to keep parallel motion. And, the robot arm which is developed in this study made an application as license.