• 제목/요약/키워드: area sampling

검색결과 1,819건 처리시간 0.026초

반월.시화공단 주변 주거지역의 악취현황 및 황화합물의 체감도 (The Concentrations of Sulfur Compounds and Sensation of Odor in the Residential Area Around Banwol-Sihwa Industrial Complex)

  • 김종보;정상진;송일석
    • 한국대기환경학회지
    • /
    • 제23권2호
    • /
    • pp.147-157
    • /
    • 2007
  • This study was carried out to investigate the characteristics of fourteen odor compounds from a total of 10 sampling sites in residential areas around Banwol-Sihwa industrial complex. The measurement data are analyzed and compared with sensation of odor unit. Only a hydrogen sulfide out of four sulfur compounds was quantified above the detection limit (0.06 ppb) in the residential area around Banwol industrial complex with leather companies and a sewage treatment plant. The concentrations of VOCs were higher than those measured from a big city, and styrene showed the relatively high concentration from all sampling sites ($2.1{\sim}37.8\;ppb$). In the case of carbonyl compounds, acetaldehyde was found most frequently with the mean of 3.97 ppb, and its concentration difference was not significant between Banwol and Sihwa industrial complex. Of the nitrogen compounds, ammonia was measured at the relatively high concentration from all the sampling sites ($12{\sim}707\;ppb$), and a trimethylamine was found at the odor threshold level (0.1 ppb). The concentrations of styrene and ammonia showed relatively seasonal variation, the concentration of styrene in summer was five times higher than that in autumn, the concentration of ammonia in autumn was two times higher than that in summer. However other odorous compounds did not show such strong seasonal variation. Odor-concentration relationship between odor unit and $H_{2}S$ concentrations from industrial sources was examined and used as odor sensation evaluation, and thus the neighbourhood odor complaints maybe caused during the four seasons from the results.

Temporal and Spatial Distribution of Particulate Carcinogens and Mutagens in Bangkok, Thailand

  • Pongpiachan, Siwatt;Choochuay, C.;Hattayanone, M.;Kositanont, C.
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권3호
    • /
    • pp.1879-1887
    • /
    • 2013
  • To investigate the level of genotoxicity over Bangkok atmosphere, $PM_{10}$ samples were collected at the Klongchan Housing Authority (KHA), Nonsree High School (NHS), Watsing High School (WHS), Electricity Generating Authority of Thailand (EGAT), Chokchai 4 Police Station (CPS), Dindaeng Housing Authority (DHA) and Badindecha High School (BHS). For all monitoring stations, each sample covered a period of 24 hours taken at a normal weekday every month from January-December 2006 forming a database of 84 individual air samples (i.e. $12{\times}7=84$). Atmospheric concentrations of low molecular weight PAHs (i.e. phenanthrene, anthracene, pyrene and fluoranthene) were measured in $PM_{10}$ at seven observatory sites operated by the pollution control department of Thailand (PCD). The mutagenicity of extracts of the samples was compared in Salmonella according to standard Ames test method. The dependence of the effects on sampling time and on sampling location was investigated with the aid of a calculation of mutagenic index (MI). This MI was used to estimate the increase in mutagenicity above background levels (i.e. negative control) at the seven monitoring sites in urban area of Bangkok due to anthropogenic emissions within that area. Applications of the AMES method showed that the average MI of $PM_{10}$ collected at all sampling sites were $1.37{\pm}0.10$ (TA98; +S9), $1.24{\pm}0.08$ (TA98; -S9), $1.45{\pm}0.10$ (TA100; +S9) and $1.30{\pm}0.09$ (TA100; -S9) with relatively less variations. Analytical results reconfirm that the particulate PAH concentrations measured at PCD air quality monitoring stations are moderately low in comparison with previous results observed in other countries. In addition, the concept of incremental lifetime particulate matter exposure (ILPE) was employed to investigate the potential risks of exposure to particulate PAHs in Bangkok atmosphere.

폴리우레탄 패드 공정에서의 원료물질 대체에 따른 근로자 노출저감 사례 (A Case of Workers' Exposure Reductions for Chemicals in a Polyurethane Pad Process through the Substitution of Raw Materials)

  • 장재길;박현희
    • 한국산업보건학회지
    • /
    • 제24권3호
    • /
    • pp.281-292
    • /
    • 2014
  • Objectives: The aim of this case study is to verify the chemical exposure reductions for various chemicals by substituting the ingredients of raw materials in a polyurethane(PU) foaming industry. The PU foaming process was making various passenger car seats from chemicals such as toluene diisocinate(TDI), methylene bisphenyl isocyanate(MDI) and polyols. Methods: Basic process data and workers' health effects could be gathered by interviewing managers and reviewing previous exposure monitoring data. Amine, aldehyde and isocyanate chemicals were analyzed following the NIOSH-NMAM. Area sampling methods rather than personal sampling were introduced for this field investigation. Results: Two amines, triethylene diamine(TEDA) and N,N,N',N'-Tetramethyl-1,6- hexanediamine(TMHDA) were identified in raw polyol, cured PU foam and air. The average concentrations of TEDA and TMHDA showd less than 1 ppm by area sampling; however, that caused halovision among workers in PU-PAD process. Aldehydes and isocyanates were detected in the air while the concentrations were relatively low compare to occupational exposure limits. Successful raw material substitution from nonreactive amine to reactive amine could reduces air-borne amine and aldehyde levels by about 70%. Halovision had been disappeared successfully in the process. Conclusions: Several amines caused halovision among workers in PU-PAD process, especially during summer season in spite of relatively low levels. Combination of reactive amines into urethane foam could reduced vapor generation into air, which resulted in the elimination of eye troubles in the process.

남양주시 하수발생특성 연구 (Study on Characteristics of Wastewater Flow for Namyangju City)

  • 황병기;이의상;김경원;손정은
    • 환경영향평가
    • /
    • 제12권2호
    • /
    • pp.73-86
    • /
    • 2003
  • In this study, we performed 8 times of water quality sampling and continuous measurement of flow to identify wastewater flow characteristics for wastewater treatment basins of Namyangju city. The field survey has been conducted 6 times in dry weather period and 2 times in wet weather period. Each survey conducted 24-hr water quality sampling in the interval of 2-hr. From the analysis of flow data and water quality data, the following conclusions can be drawn. For Namyangju-1 station, which represents residential and commercial mixed area, flow rises early in the morning before office-going hour and moves up and down within narrow range, and lasted after office-leaving hour, resulting from continuous commercial activity. In case of Namyangju-5 station representing community and Namyangju- 6 station representing residential area, the flow immediately falls down after rising early in the morning and later rises again at the office-leaving hour, and arrives at peak flows around late evening. In the analysis of wastewater characteristics for weekdays and weekends, without landuse types the flow rate of weekends is higher than that of weekdays because it reflects population, being not contributed to generate wastewater during the working hours of weekdays, stay home and produce wastewater for weekends period.

초고층건물의 사각조망에서 촬영된 지붕표면 열화상의 신뢰도 평가 (Evaluating Reliability of Rooftop Thermal Infrared Image Acquired at Oblique Vantage Point of Super High-rise Building)

  • 류택형;엄정섭
    • 한국태양에너지학회 논문집
    • /
    • 제33권5호
    • /
    • pp.51-59
    • /
    • 2013
  • It is usual to evaluate the performance of the cool roof by measuring in-site rooftop temperature using thermal infra-red camera. The principal advantage of rooftop thermal infrared image acquired in oblique vantage point of super high-rise building as a remote sensor is to provide, in a cost-effective manner, area-wide information required for a scattered rooftop target with different colors, utilizing wide view angle and multi-temporal data coverage. This research idea was formulated by incorporating the concept of traditional remote sensing into rooftop temperature monitoring. Correlations between infrared image of super high-rise building and in-situ data were investigated to compare rooftop surface temperature for a total of four different rooftop locations. The results of the correlations analyses indicate that the rooftop surface temperature by the infrared images of super high-rise building alone could be explained yielding $R^2$ values of 0.951. The visible permanent record of the oblique thermal infra-red image was quite useful in better understanding the nature and extent of rooftop color that occurs in sampling points. This thermal infrared image acquired in oblique vantage point of super high-rise made it possible to identify area wide patterns of rooftop temperature change subject to many different colors, which cannot be acquired by traditional in-site field sampling. The infrared image of super high-rise building breaks down the usual concept of field sampling established as a conventional cool roof performance evaluation technique.

토지부문 온실가스 통계 산정을 위한 토지이용변화 평가방법 비교 (Comparison of Land-use Change Assessment Methods for Greenhouse Gas Inventory in Land Sector)

  • 박진우;나현섭;임종수
    • 한국기후변화학회지
    • /
    • 제8권4호
    • /
    • pp.329-337
    • /
    • 2017
  • In this study, land-use changes from 1990 to 2010 in Jeju Island by different approaches were produced and compared to suggest a more efficient approach. In a sample-based method, land-use changes were analyzed with different sampling intensities of 2 km and 4 km grids, which were distributed by the fifth National Forest Inventory (NFI5), and their uncertainty was assessed. When comparing the uncertainty for different sampling intensities, the one with the grid of 2 km provided more precise information; ranged from 6.6 to 31.3% of the relative standard error for remaining land-use categories for 20 years. On the other hand, land-cover maps by a wall-to-wall approach were produced by using time-series Landsat imageries. Forest land increased from 34,194 ha to 44,154 ha for 20 years, where about 69% of total forest land were remained as forest land and 19% and 8% within forest lands were converted to grassland and cropland, respectively. In the case of grassland, only about 40% of which were remained as grassland and most of the area were converted to forest land and cropland. When comparing land-cover area by land-use categories with land-use statistics, forest areas were underestimated while areas of cropland and grassland were overestimated. In order to analyze land use change, it is necessary to establish a clear and consistent definition on the six land use classification.

대기 중 PM2.5의 중금속 성분의 화학적 특성 (Chemical Characteristics of Heavy Metals of PM2.5 in Atmosphere)

  • 전혜리;최수현;임지영;박희진;홍은주;손부순
    • 한국환경보건학회지
    • /
    • 제38권3호
    • /
    • pp.233-240
    • /
    • 2012
  • Objectives: The changes in atmospheric $PM_{2.5}$ concentrations were extensively studied in one metropolitan city (Incheon), two small and medium sized cities (Gunsan, Cheonan), and a rural area (Gosan in Jeju). The concentrations of heavy metals (Cr, Mn, Fe, Ni, Cu, Zn, Al, Pb) and the component features of $PM_{2.5}$ were determined for these areas. Methods: This study sampled $PM_{2.5}$ at the designated locations in the metropolitan (Incheon), small and medium sized cities (Gunsan in Jeonbuk and Cheonan in Chungnam), and rural area (Gosan in Jeju) to investigate concentrations with a sampling device (Sequential sampler, APM Eng., Korea). Sampling was undertaken over months, from June 26 to November 26, 2009. Sampling was conducted a total of 44 times, with routine sampling at intervals of six days (24 total times) and intensive sampling (20 total times) during the summer and fall. Mass concentration of $PM_{2.5}$ was evaluated and the concentrations of heavy metals (Cr, Mn, Fe, Ni, Cu, Zn, Al, Pb) were analyzed. Results: The geometric average of concentrations of $PM_{2.5}$ per district was $35.289{\mu}g/m^3$ for Cheonan, $29.955{\mu}g/m^3$ for Incheon, $24.119{\mu}g/m^3$ for Gunsan, and $18.773{\mu}g/m^3$ for Jeju, respectively. The average concentration of $PM_{2.5}$ in Cheonan was the highest. The seasonal concentration distributions per district showed Cheonan $33.387{\mu}g/m^3$, Incheon at $31.550{\mu}g/m^3$, Gunsan $22.900{\mu}g/m^3$, and Jeju $18.900{\mu}g/m^3$ in the summer. For the autumn, the concentrations were $36.873{\mu}g/m^3$ in Cheonan, $28.625{\mu}g/m^3$ in Incheon, $25.227{\mu}g/m^3$ in Gunsan, and $18.667{\mu}g/m^3$ in Jeju. According to the collected data, the concentration showed a tendency to rise during the autumn in all of these regions with the exception of Incheon. For heavy metal distribution per district, Fe showed an elevated concentration during the summer while high concentrations of Pb and Zn occurred during the autumn. Conclusion: These results demonstrated that atmospheric factors affected the concentrations of heavy metals. The results of this study could be used as foundational data for setting environmental air standards focusing on a $PM_{2.5}$ receptor.

관상어용 기포발생기를 개조한 시료채취 장치와 기존의 시료채취기와의 성능 비교 (Comparative Study on the Efficiency Test Using Remodeled Bubble Generating Pump for Aquarium Fish and Established Air Sampling Pump)

  • 장봉기;천재영;손부순;이종화;박종안
    • 한국산업보건학회지
    • /
    • 제15권3호
    • /
    • pp.183-191
    • /
    • 2005
  • This study is designed to compare the performance of established samplers (personal air sampler and MiniVOL portable air sampler) commonly used in the air environment or work environment with that of the sampler made by remodeling the air bubble generator for aquarium fishes. Sampling method used in this study is the filter collection method for PM10 and total suspended particles (TSP), the liquid collection method for sulfur dioxide ($SO_2$) and nitrogen dioxide ($NO_2$), and the solid collection method for toluene, respectively. There is not a significant difference in the average concentration of TSP between the Gilian personal air sampler (1st, $0.316{\pm}0.095$; 2nd $0.191{\pm}0.090$; 3rd, $0.185{\pm}0.073mg/m^3$) and the remodeled sampler (1st, $0.317{\pm}0.106$, 2nd $0.201{\pm}0.050$; 3rd $0.189{\pm}0.081mg/m^3$). There are also not significant differences in the average concentration of PM10 among the Gilian personal air sampler ($0.058{\pm}0.006mg/m^3$), the remodeled sampler ($0.052{\pm}0.008mg/m^3$) and the MiniVOL portable air sampler ($0.054{\pm}0.007mg/m^3$). The average concentration of the SO2 by the established sampler and the remodeled one is $3.79{\pm}0.21ppb$ and $3.45{\pm}0.15ppb$, respectively. In addition, there are not sigmficant differences in the average concentration of the NO2 between the Gilian personal air sampler (1st, $0.325{\pm}0.068$; 2nd $0.341{\pm}0.206$; 3rd, $2.971{\pm}0.078{\mu}g/m^3$) and the remodeled sampler (1st, $0.300{\pm}0.062$; 2nd $0.332{\pm}0.144$, 3rd, $2.968{\pm}0.085{\mu}g/m^3$). There are not significant differences in the average concentration of toluene between the Gilian personal air sampler (1st, $0.499{\pm}0.072$; 2nd $0.598{\pm}0.112$; 3rd $2.284{\pm}0.077{\mu}g/m^3$) and the remodeled sampler (1st, $0.463{\pm}0.133$; 2nd $0.603{\pm}0.082$; 3rd $2.353{\pm}0.115{\mu}g/m^3$). From these results, we can conclude that the performance of the remodeled sampler is not different from that of established samplers. There is possibility that the remodeled sampler can be used as a alternative device for Gilian personal air sampler in area and personal air sampling.

대구지역 공중이용시설의 실내 $\cdot$ 외 공기 중 기준성오염물질의 농도 (Concentrations of Criteria Pollutants in Indoor and Ambient Air of Public Facilities in Taegu Area)

  • 송희봉;민경섭;한개희;김종우;백성옥
    • 한국대기환경학회지
    • /
    • 제12권4호
    • /
    • pp.429-439
    • /
    • 1996
  • A comprehensive air quality monitoring was carried out in this study to investigate the concentrations of criteria air pollutants in indoor and outdoor air of public facilities in Taegu area. Four different kinds of public facilities were seleced as sampling sites, which are underground stores, stations & terminals, general hospitals, and department stores. Each group of the public facilities was consisted of three different sampling sites. As a consequence, a total of 12 different sampling sites were surveyed throughout this study. Sampling was conducted simultaneously indoors, three times per day (in the morning, afternoon, and evening) and four times per year (spring, summer, fall, and winter) at each sampling site during the period of October 1994 to July 1995. A range of criteria pollutants were measured in order to obtain a broad profile of indoor and ambient air quality, including total suspended particles (TSP), carbon monoxide (CO), carbon dioxide ($CO_2$), formaldehyde (HCHO), sulfur dioxide ($SO_2$), and nitrogen dioxide ($NO_2$). In addition, temperature, relative humidity, and air current were measured on site together with those air pollutants. Results of this study indicated that the indoor levels of TSP, CO, $SO_2, and NO_2$ appeared to be generally higher in stations/terminals and underground stores than those in department stores and hospitals. However, HCHO and $CO_2$ were found to have higher levels in the department stores and hospitals than other places, indicating that the effects of indoor sources for these pollutants are significantly different from other combustion related pollutants such as TSP, CO, and $SO_2$. It was also found that there are marked seasonal and daily variations both in indoor and outdoor air quality. In general, combustion related pollutants such as CO, $SO_2$ and $NO_2$ showed a typical pattern of higher levels in winter than insummer, and also higher in the morning and/or in the evening than in the afternoon. However, the seasonal and daily patterns of HCHO appeared to be opposite to the combustion related pollutants, i.e., higher both in summer and in the afternoon, implying the effect of temperature on the volatilization from indoor sources of HCHO. Results of correlation analyses between indoor and outdoor air quality also indicated that the effects of outdoor sources on the indoor levels of TSP, $SO_2$, CO, and $NO_2$ and much significant, whilst no significant correlations between indoor and outdoor levels were found for HCHO and $CO_2$.

  • PDF

CAN을 통신매체로 하는 역진자 시스템의 제어 (Control of an Inverted Pendulum System with CAN for Communication Medium)

  • 조성민;최현철;홍석교
    • 제어로봇시스템학회논문지
    • /
    • 제12권4호
    • /
    • pp.346-352
    • /
    • 2006
  • In a networked control system (NCS), time delays which are larger than one sampling period can change the control period. As a result, it may cause system instability. This paper presents a control method for an NCS using the controller area network (CAN), where time delays arise in the control loop. Specifically, a simple yet efficient method is proposed to improve control performance in the presence of time delays. The proposed method, which can be regarded as a gain scheduling method, selects a suitable LQ control gain among several gains to deal with the problems due to the change of control period. It is found that the gain can be scheduled in terms of the relation between the gain and the sampling period, which is represented by first-order algebraic equations. The proposed method is evaluated with an inverted cart pendulum system where the actuator and sensors are connected through the CAN. Experiment results are presented to show the efficiency of the proposed method.