• 제목/요약/키워드: archwire

검색결과 74건 처리시간 0.022초

Correction of Angle Class II division 1 malocclusion with a mandibular protraction appliances and multiloop edgewise archwire technique

  • Freitas, Benedito;Freitas, Heloiza;dos Santos, Pedro Cesar F.;Janson, Guilherme
    • 대한치과교정학회지
    • /
    • 제44권5호
    • /
    • pp.268-277
    • /
    • 2014
  • A Brazilian girl aged 14 years and 9 months presented with a chief complaint of protrusive teeth. She had a convex facial profile, extreme overjet, deep bite, lack of passive lip seal, acute nasolabial angle, and retrognathic mandible. Intraorally, she showed maxillary diastemas, slight mandibular incisor crowding, a small maxillary arch, 13-mm overjet, and 4-mm overbite. After the diagnosis of severe Angle Class II division 1 malocclusion, a mandibular protraction appliance was placed to correct the Class II relationships and multiloop edgewise archwires were used for finishing. Follow-up examinations revealed an improved facial profile, normal overjet and overbite, and good intercuspation. The patient was satisfied with her occlusion, smile, and facial appearance. The excellent results suggest that orthodontic camouflage by using a mandibular protraction appliance in combination with the multiloop edgewise archwire technique is an effective option for correcting Class II malocclusions in patients who refuse orthognathic surgery.

심미 브라켓의 종류와 브라켓-호선 각도에 따른 마찰 저항에 대한 연구 (Evaluation of friction of esthetic brackets according to different bracket-wire angulations)

  • 제영지;장민희;임용규;이동렬
    • 대한치과교정학회지
    • /
    • 제37권5호
    • /
    • pp.341-350
    • /
    • 2007
  • 본 실험은 마찰력을 줄이고 물리적 성질을 개선하여 최근에 개발된 수 종의 심미 브라켓들과 교정 탄선간에 발생하는 마찰력의 크기를 측정, 비교해 보고자 하였다. 일반 슬롯의 세라믹 브라켓인 Inspire, Signature III와 Cristaline V, 스테인레스 스틸 (SS) 슬롯을 가진 세라믹 브라켓인 Clarity, 골드 슬롯을 가진 Luxi II, polyoxymethylene 계열의 플라스틱 브라켓인 Brillant, SS 슬롯을 가진 컴파짓 브라켓인 Spirit MB, 금속 브라켓인 Integra를 사용하여 018"원형의 교정 탄선에 $0^{\circ}$, $4^{\circ}$, $8^{\circ}$의 tip angulation을 부여하고 elastic module로 결찰한 뒤 인공 타액 상태에서 활주이동 할 때의 운동 마찰력을 측정하였다. 연구 결과 슬롯에 silica 처리된 세라믹 브라켓 (CR)이 유의하게 낮은 마찰력을 보였고 (p < 0.05), 단결정 세라믹 브라켓이 (IN) 유의하게 큰 마찰력을 보였다 (p < 0.05). 플라스틱 브라켓인 polyoxymethylene 계열의 BR이 낮은 마찰력 양상을 보였고 이는 금속 브라켓과 유사하였다. 모든 브라켓에서 브라켓-탄선 각도가 증가함에 따라 유의하게 마찰력이 증가하였으나 주사전자현미경상에서 탄선이나 브라켓에 손상은 발견되지 않았다. 마찰력의 양상이 브라켓의 재질로 추측할 수 있는 것과는 다르게 나타난 결과로 보건대 심미 브라켓이 스테인레스 스틸 브라켓에 비해 마찰력 면에서는 오히려 우수하거나 큰 차이가 없으므로 임상적으로는 마찰력은 크게 고려하지 않아도 되겠다.

Orthodontic pain control following arch wire placement; a comparison between pre-emptive tenoxicam and chewing gum: a randomized clinical trial

  • Basam, Lakshman Chowdary;Singaraju, Gowri Sankar;Obili, Sobitha;Keerthipati, Thejasree;Basam, Ram Chowdary;Prasad, Mandava
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제22권2호
    • /
    • pp.107-116
    • /
    • 2022
  • Background: Pain during fixed orthodontic treatment can have a detrimental effect on patient treatment compliance. To overcome this, there is a definite need to establish the best pain-relieving methods suitable for orthodontic patients in terms of efficacy and use. The objective of this study was to compare the effect of chewing gum and pre-emptive tenoxicam on pain after initial archwire placement and to evaluate the pain perceptions of orthodontic patients in the two groups while performing various functions at specific time intervals. Methods: Forty-two patients were selected and randomly divided into two groups: group A (chewing gum) and group B (pre-emptive tenoxicam). Pain perception was documented by patients immediately; at 4 h; at bedtime on the day of archwire placement; the next morning; at 24 h; and at bedtime on the 2nd, 3rd, and 7th day after the initial archwire placement. Pain scores were noted during fitting of the posterior teeth, biting, and chewing using a visual analog scale. The data obtained were subjected to statistical analysis. Results: Group A showed a significant increase in pain until the next morning while fitting the posterior teeth, biting, and chewing [36.2, 52.0, 33.4, respectively]], followed by a gradual decrease by the 7th day. Group B showed a significant increase in pain at bedtime on biting, with a peak value of 47.5. Pain on chewing, fitting posterior teeth, peaked the morning of the next day (100.0, 45.0). The Freidman test showed a statistically significant difference with a p-value of < 0.01. Higher pain scores were observed while chewing and biting compared with that while fitting the posterior teeth in both groups. The overall comparison of pain control between the two groups was not statistically significant [P > 0.05] between the two groups. Conclusions: Chewing gum was not inferior to pre-emptive tenoxicam. Thus, chewing gum is a non-pharmacological alternative to analgesics for orthodontic pain control that eliminates the chance of adverse reactions and can be used in the absence of adult observation.

Variations in surface roughness of seven orthodontic archwires: an SEM-profilometry study

  • Amini, Fariborz;Rakhshan, Vahid;Pousti, Maryam;Rahimi, Hajir;Shariati, Mahsa;Aghamohamadi, Bahareh
    • 대한치과교정학회지
    • /
    • 제42권3호
    • /
    • pp.129-137
    • /
    • 2012
  • Objective: The purpose of this study was to evaluate the surface roughness (SR) of 2 types of orthodontic archwires made by 4 different manufacturers. Methods: This in vitro experimental study was conducted on 35 specimens of 7 different orthodontic archwires, namely, 1 nickel-titanium (NiTi) archwire each from the manufacturers American Orthodontics, OrthoTechnology, All-Star Orthodontics, and Smart Technology, and 1 stainless steel (SS) archwire each from the manufacturers American Orthodontics, OrthoTechnology, and All-Star Orthodontics. Aft er analyzing the composition of each wire by energy-dispersive X-ray analysis, the SR of each wire was determined by scanning electron microscopy (SEM) and surface profilometry. Data were analyzed using the Kruskal-Wallis and Mann-Whitney U tests (${\alpha}$ < 0.05). Results: The average SR of NiTi wires manufactured by Smart Technology, American Orthodontics, OrthoTechnology, and All-Star Orthodontics were $1,289{\pm}915A^{\circ}$, $1,378{\pm}372A^{\circ}$, $2,444{\pm}369A^{\circ}$, and $5,242{\pm}2,832A^{\circ}$, respectively. The average SR of SS wires manufactured by All-Star Orthodontics, OrthoTechnology, and American Orthodontics were $710{\pm}210A^{\circ}$, $1,831{\pm}1,156A^{\circ}$, and $4,018{\pm}2,214A^{\circ}$, respectively. Similar to the results of profilometry, the SEM images showed more defects and cracks on the SS wire made by American Orthodontics and the NiTi wire made by All-Star Orthodontics than others. Conclusions: The NiTi wire manufactured by All-Star Orthodontics and the SS wire made by American Orthodontics were the roughest wires.

Chewing gum as a non-pharmacological alternative for orthodontic pain relief: A randomized clinical trial using an intention-to-treat analysis

  • da Silva Santos, Diego Junior;Capelli, Jonas Jr.
    • 대한치과교정학회지
    • /
    • 제51권5호
    • /
    • pp.346-354
    • /
    • 2021
  • Objective: To compare the effectiveness of ibuprofen, acetaminophen, and chewing gum for orthodontic pain relief and to assess if chewing gum can be a non-pharmacological alternative for orthodontic pain relief. Methods: The study enrolled 106 patients of both sexes, aged ≥ 12 years, with body weight > 50 kg, and mild-to-moderate dental crowding in the upper arch. After randomization and allocation concealment, the intervention groups were either administered with ibuprofen (400 mg) or acetaminophen (500 mg) or chewed sugar-free chewing gum immediately after initial archwire placement and every 6 hours for 1 week if the pain persisted. The control group did not receive any pain relief. The pain was assessed on a 100-mm visual analog scale at rest and while biting down at T1 (2 hours), T2 (24 hours), T3 (2 days), T4 (3 days), T5 (7 days), and T6 (21 days). Statistical analyses were performed using the Kruskal-Wallis and post-hoc Mann-Whitney U tests (α = 0.05). Results: The chewing gum group experienced more pain relief than the ibuprofen group at while biting down at T3 (p = 0.04) and at rest at T4 (p < 0.001). The chewing gum group reported more pain relief than the acetaminophen and control groups while biting down at T3 (p = 0.03 and p = 0.0006, respectively) and T4 (both p < 0.001). Conclusions: Chewing gum can be a non-pharmacological alternative for orthodontic pain relief at 2 and 3 days after initial archwire placement.

유한요소 분석을 통한 심미적 교정 브라켓의 응력 및 구조분석에 관한 연구 (STRESS DISTRIBUTION IN ESTHETIC ORTHODONTIC BRACKETS : AN ANALYSIS USING THE FINITE ELEMENT METHOD)

  • 이원유;안주삼;박영철;박명균;손홍범;정시동
    • 대한치과교정학회지
    • /
    • 제28권1호
    • /
    • pp.43-49
    • /
    • 1998
  • 본연구는 유한요소 분석법의 사용으로 세가지 형태의 브라켓에 tipping과 torquing force를 부여하여 응력분포를 알아보고 또한 스테인레스 스틸과 세라믹의 재질을 임의 설정하여 응력 분포를 알아보아 생 역학적으로 우수한 브라켓을 디자인 하는 데 기초가 되기위해 수행되었다. 선정된 세가지 브라켓은 A:Transcend(Unitek) B:Signature(RMO) C:PAW(Plane Arch Wire appliance) 이었다. 철선은 0.0175x0.025 스테인레스 스틸과 C형은 새롭게 고안된 마름모꼴 철선이 이용되었다. tipping force는 4.27N을 브라켓의 wire slot의 gingival wall의 mesial surface와 대각선으로 대칭되는 면에 각각의 node에 분력의 형태로 작용시켰다. torquing force는 couple force의 형태로 32.858N을 19.7도 회전하였고 bracket C형은 동량의 힘을 11.3도 회전하여 X와 Y의 방향으로 분력의 형태로 나누어 해석하였고 von Mises stress(최대상당응력)가 각 브라켓에서 기록되었다. 이에 다음과 같은 결론을 얻었다. 첫째, 유한요소 해석을 통해 브라켓과 wire slot을 실제로 제작하지 않고도 각각의 재료에 따른 응력분포를 예측할 수 있었다. 둘째, 응력의 집중부위는 Tipping시 브라켓 A, B, C모두 유사하게 나타났는데 브라켓 wire slot의 gingival wall과 mesial surface가 만나는 부위와 wire slot의 incisal wall과 distal surface가 만나는 부위였다. Torquing시 wire slot의 길이 방향을 따라 넓게 분포되었고 gingival wall과 협면으로 이행되는 모서리 그리고 incisal wall내면에 집중되었다. 셋째, 브라켓에 작용하는 응력은 Tipping에 의한 것보다는 Torquing에 의한 영향이 더 큼을 알수 있었으며 Torquing force를 기준으로 브라켓을 설계하는 것이 바람직한 것으로 판단되었다. 넷째, 브라켓의 형상과 함께 재료의 변화가 응력감소에 영향을 미치는 것으로 사료되므로 브라켓 제작시 한가지 재료보다 응력이 많이 받는 부위는 다른 재료를 사용하여 응력의 분포를 줄일수도 있음을 알수있었다. 다섯째, 사용하기에 용이하고 운용이 효율적일 것으로 판단되는 브라켓C형(PAW브라켓)은 응력집중현상이 다른 두 브라켓보다 크게 나타났으므로 이의 제작시 기계적 성질이 우수한 재료를 사용해야 할 것으로 사료되었다.

  • PDF

실험적 전치 정출시 원숭이 하악 치주 조직의 변화 (HISTOLOGIC CHANGES IN MANDIBULAR PERIODONTIUM OF THE MONKEY FOLLOWING EXPERIMENTAL EXTRUSION OF ANTERIOR TEETH)

  • 이승연;김태우;장영일
    • 대한치과교정학회지
    • /
    • 제25권4호
    • /
    • pp.403-414
    • /
    • 1995
  • 본 연구는 영구치열이 완성된 원숭이 2마리를 실험 동물로 선정하여 전치간 수직 고무와 연속 호선에 의한 개교 치료 기전으로 수직피개도가 증가하였을 때, 하악 치주 조직의 조직학적 변화를 고찰하였다. 상악에 구치부 교합거상판을 장착시켜 일시적인 전치부 개교 상태를 유발하면서 상악을 고정원으로 안정화하였고, 하악에는 양측 제2대구치를 발거한 후 나머지 모든 치아에 주조금관을 제작하였다. 각 주조금관에 018inch 표준 브라켓을 납착하여 구내 고정하고, 대조동물에는 $016{\times}022$inch의 ideal archwire를, 실험동물에는 같은 크기의 MEAW(multiloop edgewise archwire)를 삽입하였다. 2주 동안 전치간 수직 고무를 적용하고 희생하였으며, 하악 치주 조직 표본을 관찰한 결과, 다음과 같은 결론을 얻었다. 1. 2주간의 실험 기간 동안 수직피개도는 대조동물에서 0.3mm, 실험동물에서 1.3mm 증가되었다. 2. 대조동물과 실험동물 모두 중절치로부터 제1소구치까지는 정출력을 받고, 제2소구치와 제1대구치는 압하력을 받은 것으로 나타났다. 3. 실험동물의 정출된 하악 절치부 치주인대는 대조군에 비하여 견인 방향에 따른 섬유 구조의 재배열이 두드러지고, 치근단과 치조정부 및 치근 측면 치조골에서 신생골 형성이 현저하였다. 4. 실험동물의 정출된 하악 절치부 치주인대의 견인력이 분포한 영역에서 과도한 치근 흡수나 초자양 변성은 관찰되지 않았다. 5. 전치부와 구치부의 치조골면에서의 골개조 현상이 대조동물에 비해서 실험동물에서 더 뚜렷하였다.

  • PDF

CONTINUOUS ARCHWIRE의 FORCE SYSTEM에 대한 3차원 유한 요소법적 연구 (THREE DIMENTIONAL FORCE ANALYSIS OF FORCE SYSTEM IN CONTINUOUS ARCHWIRE BY FINITE ELEMENT METHOD)

  • 노준;유영규
    • 대한치과교정학회지
    • /
    • 제26권1호
    • /
    • pp.17-32
    • /
    • 1996
  • 여러가지 교정장치 중에서 고정성 장치는 개개치아의 이동에 있어 가장 효과적으로 사용되는 장치이므로 그 작용기전과 역학적 관계를 이해하는 것이 중요하다. 고정성 장치의 탄선형태는 크게 continuous arch, segmented arch, sectional arch로 나누어 볼수있는데, segmented arch나 sectional arch는 힘의 작용점이 단순하고 interbracket distance도 길어 술자 임의대로 force system 조절이 가능한 반면 continuous arch에 서는 bracket geometry가 다양하고, interbracket distance가 좁아 force system의 조절이나 그 역학적 분석이 어려운게 사실이다. 저자는 공학에서의 3 dimensional elastic beam이 continuous arch의 형태와 유사한 점에 착안하여 continuous arch 의 force system을 분석하고자 하였으며, 이를 위해 다양한 형상을 갖는 3개의 bracket geometry를 표본형상으로 설정하고 기울기, 변위 및 interbracket distance에 따른 힘과 moment의 변화양상을 분석하고, 저자가 임의로 제작한 불규칙한 치아배열을 갖는 3차원 모형을 일례로하여 0.016 NiTi archwire를 bracket내에 삽입했을 때 발생되는 초기 힘과 moment를 분석 비교해본 결과 다음과 같은 결론을 얻었다. 1. Bracket의 변위 또는 기울기에 따라 나타나는 힘의 양상이 선형 대칭적인 비례관계를 보였다. 2. Interbracket distance에 따라 나타나는 힘의 양상은 비선형 대칭적인 반비례관계를 보였다. 3. 3차원 모형에서 bracket 형상이 비교적 단순한 부위에서는 표본형상과 비교분석이 가능했지만 인접치의 형상이 복잡한 부위에서는 표본형상의 예측량보다 힘이 크게 발생 되었다.나타나지 않았다. 하악의 arch length discrepancy는 하악 절치의 MD/FL index와, 상악의 arch length discrepancy는 측절치의 MD/FL index에서 상관관계를 나타내었다. 4. 정상군과 밀집군의 각 계측항목의 t-검정 결과 하악의 arch length discrepancy, overbite에서만 유의차를 나타내었다. 검사에서 Plaque Index(p<0.01)와 Gingival Index(p<0.001)가 상당히 낮은것으로 나타났다. 겔형 불화주석군에서 한 증례는 미미한 치관착색을, 두 증례는 보통정도의 치관착색을 보였다. 치아탈회 연구에서는 겔형 불화주석군과 불화나트륨 양치액군이 치료후 치아탈회값에서 치료전 치아탈회값을 뺀 치아탈회값이 대조군에 비해 구강전체및 제1대구치에서 현저하게 낮은 값(p<0.05)을 보였다. 비록 겔형 불화주석군이 불화나트륨 양치액군보다 일관되게 낮은 치아탈회값을 보였을지라도 통계적으로 그 차이는 단지 유의성을 보이는 정도였다.는 골기질의 주성분인 type I 교원질의 합성을 선택적으로 억제하는 기능과 alkaline phosphatase의 활성을 크게 증가시키지 못한 점 등으로 미루어 볼 때, 골개조를 억제하는 방향으로 작용한다고 볼 수 있으며, 교정치료 과정중 골개조를 억제하는 부위에서 사용을 시도해 볼 수 있겠다.>신뢰구간은 상악에서 정상교합군은 $79.5-81.0\%$, 비발치군은 $81.6-84.9\%$, 발치군은 $70.1-72.2\%$로 나타났으며, 하악에서 정상교합군은 $79.8-82.2\%$, 비발치군은 $82.1-85.5\%$, 발치군은 $73.1-75.1\%$로 나타났다. 7. 최대치아근원심폭경합, 기저악궁폭경, 기저악궁장경, 최대치아근원심폭경 합에 대한

  • PDF

Correction of dental Class III with posterior open bite by simple biomechanics using an anterior C-tube miniplate

  • Ahn, Hyo-Won;Chung, Kyu-Rhim;Kang, Suk-Man;Lin, Lu;Nelson, Gerald;Kim, Seong-Hun
    • 대한치과교정학회지
    • /
    • 제42권5호
    • /
    • pp.270-278
    • /
    • 2012
  • In the correction of dental Class III molar relationship in skeletal Class II patients, uprighting of the mandibular posterior segments without opening the mandible is an important treatment objective. In the case reported herein, a C-tube miniplate fixed to the lower labial symphysis and connected with a nickel-titanium reverse-curved archwire provided effective uprighting of the lower molars, without the need of orthodontic appliances on the mandibular anteriors. Using this approach, an appropriate magnitude of force is exerted on the molars while avoiding any negative effect on the mandibular anteriors.

교정선의 종류, 결찰방법, 타액의 유무에 따른 마찰력의 비교연구 (A comparative study of frictional forces according to orthodontic wires and ligation method under dry and wet conditions)

  • 이진우;차경석;한정숙
    • 대한치과교정학회지
    • /
    • 제31권2호통권85호
    • /
    • pp.271-281
    • /
    • 2001
  • 치아에 부착된 bracket이 교정선을 따라 이동할때 필연적으로 bracket과 교정선, 결찰재 사이에 마찰력이 발생된다. 이에 저자는 동일한 bracket내에서 교정선의 종류, 결찰방법, 건조와 타액상태에 따른 마찰력 차이, 타액의 윤활제로서의 기능을 살펴보기 위해 본 연구를 시행하게 되었다. 본 실험에 사용된 bracket은 .18" ${\times}$ .025" slot의 상악 견치용 standard edgewise bracket(RMO. USA)이며, 교정선은 .016" , .016" ${\times}$ .022" 크기의 Cobalt-chromium(Elgiloy : RMO. USA), Nickel-titanium(Ni-Ti) (ORTHOLLOY : Goldstar Cable Co. KOREA), Beta- titanium(TMA : ORMCO Co., USA)의 2가지 형태의 3종을 이용하여 활주할 때의 마찰력을 만능시험기(Instron, M 1000 EC)를 사용하여 계측하여 다음과 같은 결론을 얻었다. 1. 각각의 동일조건하에서 교정선의 재질에 따른 마찰력은 Co-Cr, Ni-Ti, ${\beta}$-Ti순으로 증가하였다. 단, 타액상태에서 elastomeric으로 결찰한 .016" 군에서는 예외이다. 2. 각 조건하(건조/타액상태, .016" /.016" ${\times}$.022" ) 에서 결찰방법에 따른 마찰력은 elastomeric보다 stainless steel결찰에서 더 크게 나타났다(p<0.05). 3. 각각의 교정선과 결찰방법에서 타액 유무에 따른 마찰력은 stainless steel로 결찰한 .016" Co-Cr, Ni-Ti, ${\beta}$-Ti는 타액상태에서 감소하나, stainless steel로 결찰한 .016" ${\times}$.022" Co-Cr, Ni-Ti, ${\beta}$-Ti는 타액상태에서 증가하였다(p<0.05). 4. 각 조건하(건조/타액상태, elastomeric/stainless steel 결찰) .016" 과 .016" ${\times}$.022" 교정선 사이의 마찰력은 .016" ${\times}$.022" 교정선에서 증가하였다(p<0.05).

  • PDF