• Title/Summary/Keyword: architecture model

Search Result 5,816, Processing Time 0.033 seconds

Heat Budget Analysis of Light Thin Layer Green Roof Planted with Zoysia japonica (한국잔디식재 경량박층형 옥상녹화의 열수지 해석)

  • Kim, Se-Chang;Lee, Hyun-Jeong;Park, Bong-Ju
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.6
    • /
    • pp.190-197
    • /
    • 2012
  • The purpose of this study was to evaluate thermal environment and heat budget of light thin layer green roof through an experiment in order to quantify its heat budget. Two concrete model boxes($1.2m(W){\times}1.2m(D){\times}1.0m(H)$) were constructed: One experiment box with Zoysia japonica planted on substrate depth of 10cm and one control box without any plant. Between June 6th and 7th, 2012, outside climatic conditions(air temperature, relative humidity, wind direction, wind speed), evapotranspiration, surface and ceiling temperature, heat flux, and heat budget of the boxes were measured. Daily maximum temperature of those two days was $29.4^{\circ}C$ and $30^{\circ}C$, and daily evapotranspiration was $2,686.1g/m^2$ and $3,312.8g/m^2$, respectively. It was found that evapotranspiration increased as the quantity of solar radiation increased. A surface and ceiling temperature of those two boxes was compared when outside air temperature was the greatest. and control box showed a greater temperature in both cases. Thus it was found that green roof was effective in reducing temperature. As results of heat budget analysis, heat budget of a green roof showed a greater proportion of net radiation and latent heat while heat budget of the control box showed a greater proportion of sensible heat and conduction heat. The significance of this study was to analyze heat budget of green roof temperature reduction. As substrate depth and types, species and seasonal changes may have influences on temperature reduction of green roof, further study is necessary.

Study on the Planning Method of the Sacheonwangsa Temple Architecture in Silla (신라사천왕사건축(新羅四天王寺建築)의 설계기술(設計技術) 고찰(考察))

  • Lee, Jeongmin;Mizoguchi, Akinori
    • Korean Journal of Heritage: History & Science
    • /
    • v.53 no.3
    • /
    • pp.80-109
    • /
    • 2020
  • The Sacheonwangsa Temple in Silla is an esoteric temple that was founded provisionally in 670, and was completed in 679. This study attempted to elucidate the planning method of the Sacheonwangsa Temple based on the results of research on excavations and investigations into its construction processes and construction measures thereof. The research results are as follows. (1) In the site construction, assuming the size of one Bang (坊) on the south of Nangsan Mountain, after dividing the north-south width into three equal parts, there is a possibility that two of these parts were set to the flat portion. (2) In the 'Jochang (祖創, 670)', it is estimated that an area of 300 cheoks by 300 cheoks was postulated on the flat surface, and, as an initial conception, the mandala's plane design of the outer square 2 hasta (3 cheoks) and inner square 1 hasta (1.5 cheoks) was originally devised for the setting of 'Mudra (神印)', and an area 100 times greater has been set as the basis in the scale and layout planning of the central block. (3) During 'Gaechang (攺刱, ~679)', it is judged that because of the narrowness of the distance between the Pagoda and Geumdang Hall, which occurs when the center of the Geumdang Hall coincides with the center of 'the first stage of the foundation (先築基壇)', the scale and layout planning were adjusted from the initial conception. (4) The arrangement of the building was determined by dividing the fixed size of the central block (280 cheoks by 320 cheoks). Specifically, the east-west direction is set on the quartile's line of the east-west width of the central block, and in contrast, the north-south direction is based on the structural characteristics of the central block. It is presumed that the position of the transept was determined through the division and adjustment of the column spacing of the east-west corridor, then the Geumdang Hall and Altar were based on this. (5) The scale of the Geumdang Hall and Pagoda is determined by the petition of the division by the unit fraction starting from the quartile's line of the central block's east-west width. This planning is understood to be based on the self-similarity, which is rooted in the mandala's plane design as the model.

Data Mining Approaches for DDoS Attack Detection (분산 서비스거부 공격 탐지를 위한 데이터 마이닝 기법)

  • Kim, Mi-Hui;Na, Hyun-Jung;Chae, Ki-Joon;Bang, Hyo-Chan;Na, Jung-Chan
    • Journal of KIISE:Information Networking
    • /
    • v.32 no.3
    • /
    • pp.279-290
    • /
    • 2005
  • Recently, as the serious damage caused by DDoS attacks increases, the rapid detection and the proper response mechanisms are urgent. However, existing security mechanisms do not effectively defend against these attacks, or the defense capability of some mechanisms is only limited to specific DDoS attacks. In this paper, we propose a detection architecture against DDoS attack using data mining technology that can classify the latest types of DDoS attack, and can detect the modification of existing attacks as well as the novel attacks. This architecture consists of a Misuse Detection Module modeling to classify the existing attacks, and an Anomaly Detection Module modeling to detect the novel attacks. And it utilizes the off-line generated models in order to detect the DDoS attack using the real-time traffic. We gathered the NetFlow data generated at an access router of our network in order to model the real network traffic and test it. The NetFlow provides the useful flow-based statistical information without tremendous preprocessing. Also, we mounted the well-known DDoS attack tools to gather the attack traffic. And then, our experimental results show that our approach can provide the outstanding performance against existing attacks, and provide the possibility of detection against the novel attack.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2013 (설비공학 분야의 최근 연구 동향 : 2013년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.12
    • /
    • pp.605-619
    • /
    • 2014
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2013. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and relative parts including orifices, dampers and ducts, fuel cells and power plants, cooling and air-conditioning, heat and mass transfer, two phase flow, and the flow around buildings and structures. Research issues dealing with home appliances, flows around buildings, nuclear power plant, and manufacturing processes are newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for general analytical model for desiccant wheels, the effects of water absorption on the thermal conductivity of insulation materials, thermal properties of Octadecane/xGnP shape-stabilized phase change materials and $CO_2$ and $CO_2$-Hydrate mixture, effect of ground source heat pump system, the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, a parallel flow evaporator for a heat pump dryer, the condensation risk assessment of vacuum multi-layer glass and triple glass, optimization of a forced convection type PCM refrigeration module, surface temperature sensor using fluorescent nanoporous thin film. In the area of pool boiling and condensing heat transfer, researches on ammonia inside horizontal smooth small tube, R1234yf on various enhanced surfaces, HFC32/HFC152a on a plain surface, spray cooling up to critical heat flux on a low-fin enhanced surface were actively carried out. In the area of industrial heat exchangers, researches on a fin tube type adsorber, the mass-transfer kinetics of a fin-tube-type adsorption bed, fin-and-tube heat exchangers having sine wave fins and oval tubes, louvered fin heat exchanger were performed. (3) In the field of refrigeration, studies are categorized into three groups namely refrigeration cycle, refrigerant and modeling and control. In the category of refrigeration cycle, studies were focused on the enhancement or optimization of experimental or commercial systems including a R410a VRF(Various Refrigerant Flow) heat pump, a R134a 2-stage screw heat pump and a R134a double-heat source automotive air-conditioner system. In the category of refrigerant, studies were carried out for the application of alternative refrigerants or refrigeration technologies including $CO_2$ water heaters, a R1234yf automotive air-conditioner, a R436b water cooler and a thermoelectric refrigerator. In the category of modeling and control, theoretical and experimental studies were carried out to predict the performance of various thermal and control systems including the long-term energy analysis of a geo-thermal heat pump system coupled to cast-in-place energy piles, the dynamic simulation of a water heater-coupled hybrid heat pump and the numerical simulation of an integral optimum regulating controller for a system heat pump. (4) In building mechanical system research fields, twenty one studies were conducted to achieve effective design of the mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, and renewable energies in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment is mostly focused on indoor environment and building energy. The main researches of indoor environment are related to infiltration, ventilation, leak flow and airtightness performance in residential building. The subjects of building energy are worked on energy saving, operation method and optimum operation of building energy systems. The remained studies are related to the special facility such as cleanroom, internet data center and biosafety laboratory. water supply and drain system, defining standard input variables of BIM (Building Information Modeling) for facility management system, estimating capability and providing operation guidelines of subway station as shelter for refuge and evaluation of pollutant emissions from furniture-like products.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2012 (설비공학 분야의 최근 연구 동향 : 2012년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwataik;Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Choi, Jong Min;Park, Jun-Seok;Kim, Sumin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.6
    • /
    • pp.346-361
    • /
    • 2013
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2012. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. The conclusions are as follows : (1) The research works on thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and valves, fuel cells and power plants, ground-coupled heat pumps, and general heat and mass transfer systems. Research issues are mainly focused on new and renewable energy systems, such as fuel cells, ocean thermal energy conversion power plants, and ground-coupled heat pump systems. (2) Research works on the heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer, and industrial heat exchangers. Researches on heat transfer characteristics included the results for natural convection in a square enclosure with two hot circular cylinders, non-uniform grooved tube considering tube expansion, single-tube annular baffle system, broadcasting LED light with ion wind generator, mechanical property and microstructure of SA213 P92 boiler pipe steel, and flat plate using multiple tripping wires. In the area of pool boiling and condensing heat transfer, researches on the design of a micro-channel heat exchanger for a heat pump, numerical simulation of a heat pump evaporator considering the pressure drop in the distributor and capillary tubes, critical heat flux on a thermoexcel-E enhanced surface, and the performance of a fin-and-tube condenser with non-uniform air distribution and different tube types were actively carried out. In the area of industrial heat exchangers, researches on a plate heat exchanger type dehumidifier, fin-tube heat exchanger, an electric circuit transient analogy model in a vertical closed loop ground heat exchanger, heat transfer characteristics of a double skin window for plant factory, a regenerative heat exchanger depending on its porous structure, and various types of plate heat exchangers were performed. (3) In the field of refrigeration, various studies were executed to improve refrigeration system performance, and to evaluate the applicability of alternative refrigerants and new components. Various topics were presented in the area of refrigeration cycle. Research issues mainly focused on the enhancement of the system performance. In the alternative refrigerant area, studies on CO2, R32/R152a mixture, and R1234yf were performed. Studies on the design and performance analysis of various compressors and evaporator were executed. (4) In building mechanical system research fields, twenty-nine studies were conducted to achieve effective design of mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, renewable energy systems, and lighting systems in buildings. New designs and performance tests using numerical methods and experiments provide useful information and key data, which can improve the energy efficiency of buildings. (5) In the fields of the architectural environment, studies for various purposes, such as indoor environment, building energy, and renewable energy were performed. In particular, building energy-related researches and renewable energy systems have been mainly studied, reflecting interests in global climate change, and efforts to reduce building energy consumption by government and architectural specialists. In addition, many researches have been conducted regarding indoor environments.

Study on the Treesize Prediction Model : A case study of Zelkova serrata, Pinus strobus and Magnolia denudata (주요조경수목의 크기 예측 " 모델 "에 관한 연구 : 느티나무, 스트로브잣나무, 백목련을 대상으로)

  • 김남춘;최준수;문석기
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.16 no.1
    • /
    • pp.27-35
    • /
    • 1988
  • Size characteristics of three widely used landscape trees were analized to establish a methodology of size prediction as time Passes. Tree height, tree width, stem diameter(breast or surface), canopy length and tree age were measured directly and indirectly(by using photograph), and the data were analized by using regression analysis through PC-SAS. The results are summarized as follows : 1. Zelkova serrata MAKINO showed relatively slow growth rate and the tree form was changed as aged. Size predictions were available by using the regression equations listed below : Surface diameter = 0.8293 x AGE Tree height = 0.4109(0.8293 x AGE) - 0.0039(0.7273 x AGE)$^2$Tree width = 0.3240(0.8293 x AGE) - 0.0024(0.1293 x AGE)$^2$Canopy length = 0.1337(0.8293 x AGE) - 0.0020(0.7293 x AGE)$^2$2. Pinus strobus L. showed relatively fast growth rate and the tree form did not change much as aged. Size predictions were available by using the regression equations listed below. Breast diameter = 0.756 x AGE Tree height = 0.7695(0.756 x AGE) - 0.0164(0.75\ulcorner x AGE)$^2$Tree width = 0.4331(0.756 x AGE) - 0.0079(0.75\ulcorner x AGE)$^2$Canopy length = 0.1365(0.756 x AGE) - 0.0032(0.75f x AGE)$^2$ 3. In case of Magnolia denudata DESROUX, tree form was determined relatively earlier than the other two species. Si2e predictions were available by using the regression equations listed below : Surface diameter = 0.88 x AGE Tree height = 0.5412(0.88 x AGE) - 0.0110(0.88 x AGE)$^2$ Tree width = 0.3752(0.88 x AGE) - 7.0061(0.88 x AGE)$^2$Canopy length = 0.1110(0.88 x AGE) - 0.0022(0.88 x AGE)$^2$ This study aimed to find a way to predict size change of landscaping plants. This methodology will be applied to a wide range of landscape plants to provide practical data to landscape designers.

  • PDF

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2015 (설비공학회 분야의 최근 연구 동향 : 2015년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.6
    • /
    • pp.256-268
    • /
    • 2016
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2015. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering were carried out in the areas of flow, heat and mass transfer, cooling and heating, and air-conditioning, the renewable energy system and the flow inside building rooms. Research issues dealing with air-conditioning machines and fire and exhausting smoke were reduced. CFD seems to be spreading to more research areas. (2) Research works on heat transfer area were carried out in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the economic analysis of GHG emission, micro channel heat exchanger, effect of rib angle on thermal performance, the airside performance of fin-and-tube heat exchangers, theoretical analysis of a rotary heat exchanger, heat exchanger in a cryogenic environment, the performance of a cross-flow-type, indirect evaporative cooler made of paper/plastic film. In the area of pool boiling and condensing, the bubble jet loop heat pipe was studied. In the area of industrial heat exchangers, researches were performed on fin-tube heat exchanger, KSTAR PFC and vacuum vessel at baking phase, the performance of small-sized dehumidification rotor, design of gas-injection port of an asymmetric scroll compressor, effect of slot discharge-angle change on exhaust efficiency of range hood system with air curtain. (3) In the field of refrigeration, various studies were carried in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, a cold-climate heat pump system, $CO_2$ cascade systems, ejector cycles and a PCM-based continuous heating system were investigated. In the alternative refrigeration/energy system category, a polymer adsorption heat pump, an alcohol absorption heat pump and a desiccant-based hybrid refrigeration system were investigated. In the system control category, turbo-refrigerator capacity controls and an absorption chiller fault diagnostics were investigated. (4) In building mechanical system research fields, eighteen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the user and location awareness technology applied dimming lighting control system, the lighting performance evaluation for light-shelves, the improvement evaluation of air quality through analysis of ventilation efficiency and the evaluation of airtightness of sliding and LS window systems. The subjects of building energy were worked on the energy saving estimation of existing buildings, the developing model to predict heating energy usage in domestic city area and the performance evaluation of cooling applied with economizer control. The studies were also performed related to the experimental measurement of weight variation and thermal conductivity in polyurethane foam, the development of flame spread prevention system for sandwich panels, the utilization of heat from waste-incineration facility in large-scale horticultural facilities.

Analysis and Management Strategies of the Cold Air Characteristics in Hannamgeumbuk-Jeongmaek and Geumbuk-Jeongmaek (한남금북·금북정맥 일대의 찬공기 특성 분석을 통한 청주시 찬공기 관리방안)

  • SON, Jeong-Min;EUM, Jeong-Hee
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.22 no.2
    • /
    • pp.152-171
    • /
    • 2019
  • In this study, we analyzed the characteristics of the cold air generated in Hannamgeumbuk and Geumbuk-Jeongmaek and proposed their management strategies. We also suggested management strategies after analyzing detailed cold airflows for Cheongju located Hannamgeumbuk-Jeongmaek and we compared the degree of nighttime temperature reduction of the Jeongmaek by using data obtained from observatories located on Cheongju. We used KALM(Kaltluftabflussmodell), a cold air simulation model developed in Germanay and identified both cold airflows and altitude of cold air layers generated during 360minutes at night. As a result, the cold airflow generated in the Jeongmaek became strong and the cold air was appeared clearly in the western part of the Hannamgeumbuk-Jeongamek and in the northern part of the Geumbuk-Jeongmaek. The average velocity of cold airflow was recorded at 0.45m/s, and the maximum speed of cold airflow was recorded at 2.70m/s. The average height of the cold air layer was 104.27m/s and the maximum thickness was 255.0m. The average velocity of cold airflows in Cheongju was 0.51m/s and the average height of cold air layer was 48.87m high. The highest degree of nighttime temperature reduction appeared in the Cheongnamdae observatory($-3.8^{\circ}C$), where the altitude of the cold air layer is high. The results showed that cooling effect of Jeongmaek actually affected the temperature reduction during nighttime. Based on the results, we designated the main mountain area of the Jeongmaek with active cold air generation as "cold air conservation areas" and proposed the current forest and topography conservation. We also proposed to designate areas that facilitate the cold airflows as "cold air management areas" and to complement the function of Jeongmaek. This study could support the establishment of systematic management plans of the Jeongmaek. In addition, it is expected that the results can be applied as basic data for ventilation paths of Cheongju.

Development of 3D Impulse Calculation Technique for Falling Down of Trees (수목 도복의 3D 충격량 산출 기법 개발)

  • Kim, Chae-Won;Kim, Choong-Sik
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.51 no.2
    • /
    • pp.1-11
    • /
    • 2023
  • This study intended to develop a technique for quantitatively and 3-dimensionally predicting the potential failure zone and impulse that may occur when trees are fall down. The main outcomes of this study are as follows. First, this study established the potential failure zone and impulse calculation formula in order to quantitatively calculate the risks generated when trees are fallen down. When estimating the potential failure zone, the calculation was performed by magnifying the height of trees by 1.5 times, reflecting the likelihood of trees falling down and slipping. With regard to the slope of a tree, the range of 360° centered on the root collar was set in the case of trees that grow upright and the range of 180° from the inclined direction was set in the case of trees that grow inclined. The angular momentum was calculated by reflecting the rotational motion from the root collar when the trees fell down, and the impulse was calculated by converting it into the linear momentum. Second, the program to calculate a potential failure zone and impulse was developed using Rhino3D and Grasshopper. This study created the 3-dimensional models of the shapes for topography, buildings, and trees using the Rhino3D, thereby connecting them to Grasshopper to construct the spatial information. The algorithm was programmed using the calculation formula in the stage of risk calculation. This calculation considered the information on the trees' growth such as the height, inclination, and weight of trees and the surrounding environment including adjacent trees, damage targets, and analysis ranges. In the stage of risk inquiry, the calculation results were visualized into a three-dimensional model by summarizing them. For instance, the risk degrees were classified into various colors to efficiently determine the dangerous trees and dangerous areas.

A Study on Estimation of Environmental Value of Tentatively Named 'East-West Trail' Using CVM (CVM기법을 이용한 가칭 '동서트레일'의 환경가치 추정)

  • Kee-Rae Kang;Yoon-Ho Choi;Bo-Kwang Chung;Dong-Pil Kim;Hyun-Kyeong Oh;Woo-Sung Lee;Su-Bok Chae
    • Korean Journal of Environment and Ecology
    • /
    • v.36 no.6
    • /
    • pp.676-683
    • /
    • 2022
  • Due to the effects of rapid changes in the living environment since 2000 and the recent unforeseen pandemic, people are refraining from domestic and international traveling and movement, and outdoor activities for health and the public value of forest trails, called Dullegil Trail in Korea, have become more important. This study estimated the environmental value of the tentatively named "East-West Trail," which connects the forest trails crossing Chungcheong and Gyeongsang Provinces using CVM (Contingent Valuation Method). It surveyed visitors to the East-West Trail, and 725 questionnaires were used for analysis. The average characteristics of respondents were those who exercised 2-3 times per week, visited a forest trail not far from their residence with friends or family, and showed a tendency to spend 50 thousand Korean won or more per visit. Visitors to the Dullegil Trail felt that there was a shortage of information boards on the forest trail, and they preferred a shelter in appropriate locations. We used a double-bounded dichotomous choice (BDDC) logit model proposed by Hanemann to measure the conservation value of the East-West Trail. It was estimated that the environmental value that a visitor to the East-West Trail could obtain was 30,087 won per trip. The estimated environmental value of the East-West Trail can be converted to about 94 billion won total visitors annually based on the population belonging to the direct-use zone near the East-West Trail. As there has been no study on the environmental value of forest trails using CVM, the results of this study will be able to suggest the feasibility of the government policies on forest trails.