• Title/Summary/Keyword: arch greenhouse

Search Result 26, Processing Time 0.025 seconds

Roof Ventilation Structure for Single Span Greenhouses of Arch Shape (아치형 단동 온실의 지붕 환기 구조)

  • Nam, Sang-Woon
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2001.10a
    • /
    • pp.267-270
    • /
    • 2001
  • It is difficult to install a ventilation window on the roof of single span greenhouse of arch shape. Investigation on the roof ventilation structure for those greenhouses was conducted. The effect of roof ventilation was evaluated by comparative experiments between greenhouse installing roof vent and having controlled side vent only. And ventilation efficiency was analyzed by experiments on the opening and closing operation of the roof and side vent.

  • PDF

Collapse Prevention Method of Long-span Plastic Greenhouse for Heavy Snow (장스팬 비닐하우스의 폭설에 의한 붕괴방지법 연구)

  • Kim, Bo-Kyung;Lee, Swoo-Heon;Kim, Jin-Wook;Shin, Kyung-Jae
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.1
    • /
    • pp.67-74
    • /
    • 2010
  • The cases of collapse of greenhouses in rural areas have been increasing due to the unexpected heavy snow load. Studies on how to prevent the collapse of greenhouses are rare, however, and the damages are repeated annually. This studysuggests two reinforcing methods: the use of ahigh-strength tapered module, and the addition of a pre-tension tie. The high-strength tapered section is installed where the bending moment is maximum. The design of a plastic greenhouse is controlled by its strength rather than its deflection. The shape of a greenhouse resembles that of an arch system, but its actual structural behavior is the frame behavior, because it is non-continually composed of a curved element (a beam) and vertical elements (columns). This system is too weak and slender to resist a vertical load, because an external load is resisted by the moment rather than by axial force. In this study, a new method, the installation of a temporary tie at the junction of the arch and the column only during snow accumulation, is proposed. The tie changes the action of the greenhouse frame to an arch action. The arch action is more effective when the pre-tension force is applied in the tie, which results in a very strong temporary structural system during snowfall. As a result of using this high-strength tapered section, the combined strength ratio of what? decreased from 10% to 30%. In the case of the additional reinforcement with a tie, it was reduced by half.

Development of Structural Model and Analysis of Design Factors for Small Greenhouse of Urban Agriculture (도시농업을 위한 소형온실 설계요인 분석 및 구조모델 개발)

  • Kim, Hyung-Kweon;Ryou, Young-Sun;Kim, Young-Hwa;Lee, Tae-Seok;Oh, Sung-Sik;Lee, Won-Suk;Kim, Yong-Hyeon
    • Journal of Bio-Environment Control
    • /
    • v.28 no.4
    • /
    • pp.388-395
    • /
    • 2019
  • The purpose of this study is to suggest structural model and analyze design factors for the development of small greenhouse standardization model. The average dimensions of small greenhouse desired by urban farmers were 3.3m in width, 1.9m in eaves height, 2.7m in ridge height, 5.7m in length. The cladding materials for small greenhouse were preferred to glass, PC board and plastic film, framework to aluminum alloy and steel, and heating method in electrical energy. In addition, it was analyzed that small greenhouses need to develop structural model by dividing them into entry-level type and high-level type. The roof type that was used for entry-level type was arch shape, framework was steel pipe, cladding material was plastic film. On the other hand, high-level type was used in even span or dutch light type, framework with square hollow steel, cladding materials with glass or PC board. In consideration of these findings and practicality, this study developed four types of small greenhouses. The width, eaves height, ridges height, and length of the small greenhouses of even span type, which were covered with 5mm thick glass and 6mm thick PC board were 3m, 2.2m, 2.9m, and 6m, respectively. The small greenhouse of dutch light type covered with 5mm thick glass was designed with 3.8m in with, 2.2m in eaves height, 2.9m in ridges height, and 6m in length. The width, eaves height, ridges height, and length of the arch shape small greenhouse covered with a 0.15mm PO film were 3m, 1.5m, 2.8m, and 6m, respectively.

Modal Testing of Arches for Plastic Film-Covered Greenhouses (비닐하우스 아치구조의 모달실험)

  • Cho, Soon-Ho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.14 no.2
    • /
    • pp.57-65
    • /
    • 2010
  • To determine the static buckling loads and evaluate the structural performance of slender steel pipe-arches such as for greenhouse structures, a series of modal tests using a fixed hammer and roving sensors was carried out, by providing no load, then a range of vertical loads, on an arch rib in several steps. More attention was given to an internal arch where vertical and horizontal auxiliary members are not placed, unlike an end arch. Modal parameters such as natural frequencies, mode shapes and damping ratios were extracted using more advanced system identification methods such as PolyMAX (Polyreference Least-Squares Complex Frequency Domain), and compared with those predicted by commercial FEA (Finite Element Analysis) software ANSYS for various conditions. A good correlation between them was achieved in an overall sense, however the reduction of natural frequencies due to the existence of preaxial loads was not apparent when the vertical load level was about up to 38% of its resistance. Some difficulties related to the field testing and parameter extraction for a very slender arch, as might arise from the influences of neighboring members, are carefully discussed.

Development of a Gable-roofed Prefabricated Pipe-house for Improvement of Snow Endurance (내설성 향상을 위한 지붕형 조립식 파이프하우스의 개발)

  • Yang, In-Kyoo;Nam, Sang-Woon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.51 no.3
    • /
    • pp.71-78
    • /
    • 2009
  • Pipe section of bending part at the arch type pipe-house showed an ellipse with oblateness of 0.076 on the average. Flexural rigidity of bending part decreased by average 6.3% than that of an original round shape section. The deflection of arch type pipe-house measured by model experiments showed much bigger than the result of structural analysis. In case of arch type pipe-house, we supposed that the decrease of flexural rigidity for the bending part of pipes had an effect on deflection of roof under the working load. This effect should be considered in the structural analysis. Bending resistance of gable type pipe-house used a prefabricated connector which developed in this study showed about $1.5{\sim}1.8$ times stronger than that of the existing arch type or gable type processed bending. Therefore, we supposed that the gable-roofed prefabricated pipe-house is safer than arch type or bent gable type in case of heavy snowfall. According to house scales and section properties of steel pipe in use, safe snow depths and rafter intervals were presented for design of gable-roofed prefabricated pipe-house. Their standards were established in the range of the durable models recommended by RDA, and the comparative examinations were conducted by means of structural analysis. It was evaluated that the developed greenhouse model had a high applicability in the field.

Development of Design Technology of Korean Style Air-Inflated Double-Layer Plastic Greenhouse (한국형 공기주입 이중피복 플라스틱온실의 설계기술 개발)

  • Lee, Hyun-Woo;Sim, Sang-Youn;Nam, Hyo-Seok;Nam, Sang-Woon;Kim, Young-Shik
    • Journal of Bio-Environment Control
    • /
    • v.18 no.3
    • /
    • pp.185-191
    • /
    • 2009
  • The construction of experimental greenhouses, operating test, and analysis on variation of different environment factors were conducted to provide fundamental data for design of Korean style air-inflated double-layer plastic greenhouse. The development of technology of attaching plastic to the structure and fasteners to be able to keep airtight was required in order to maintain proper static pressure in air space of double layer coverings. The insulation effect of air inflated greenhouse was better than conventional type. The temperature of arch type roof was greater about $2^{\circ}C$ than peach type roof in air inflated greenhouse. It was recommended that the plastic should be attached at the edges without clearance length in order to ease installation and raise airtightness of double layer coverings. The transmittance of arch type roof was greater than peach type in air inflated one span greenhouse. The transmittance of air inflated greenhouse was greater than conventional type due to frame ratio and distance between double layers in three span greenhouse. The condensation occurred on conventional type greenhouse was more than air inflated type. It was required to examine for a long time in order to analyze it quantitatively.

Greenhouse environment analysis -Distributions and Variations of Temperature , Relative humidity Illumination , Carbon dioxide and Wind Velocity-

  • Kim, Y.B;Park, J.C.;Song, H.K.;Paek, Y.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1993.10a
    • /
    • pp.478-486
    • /
    • 1993
  • For satisfactory greenhouse culture, environmental factors must be kept in proper conditions. Therefore, it is important to know relations between environmental conditions and greenhouse systems. In this study, the environment variations and distributions in different types of greenhouses were measured and analyzed. The elements of environment analyzed were temperature , relative humidity, illumination, carbon dioxide and wind velocity. The analyzed greenhouse types were three different types. One of them, A type, was propagation model type by government and the other one, B type, was multiple continuous arches type which was made by farmers himself. The last one, C type, was single arch type which has no environment control system without manual temperature keeping method. The results of this study can be used for reasonable greenhouse environments managements and control.

  • PDF

Reinforcement Method of a Long Span Plastic Greenhouse using Tension-tie (인장타이를 이용한 광폭형 비닐하우스의 보강법)

  • Shin, Kyung-Jae;Shin, Dong-Hui;Lee, Swoo-Heon;Chae, Seoung-Hun
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.1
    • /
    • pp.41-49
    • /
    • 2011
  • A long-span (more than 8m) plastic greenhouse is currently being used in farms due to its magnified benefits, such as the convenience of the farming equipment used, and the land usage efficiency. In this study, the reinforcing effects of the use of a pretension tie were shown. In a previous study, tests for a 6.5m single-span-type greenhouse announced by Rural Development Administration were carried out. The tests of symmetric and eccentrics now loading by the sun and wind were conducted for the 10.2m span with a ${\phi}48.1{\times}2.1$ section in this study, after which the load-deflection relationship was compared for the cases of reinforcement with a tie and without a tie. The results of the symmetric snow loading test showed that the strength increased by 68~93% in the case of the specimen with a tied arch. The failure mode of the specimen without a tie tended to be that with a sway failure mechanism, and that of the reinforcement specimens with a tie tended to be that with an arch buckling mechanism. The results of the eccentric snow loading test showed that the strength of the specimen with a tie increased by 10~20% compared to that of the specimen without a tie. For the failure mode of the latter, a combined failure mechanism was adapted, although the failure mode of the tied specimens tended to be that with an arch buckling mechanism.

A Study on the Development of Stress Tolerant Structural Systems in the Frame of Built-up Greenhouses (내재해형 조립 비닐하우스 골조 구조시스템 개발 연구)

  • Han, Duckjeon;Shim, Jongseok
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.18 no.2
    • /
    • pp.11-18
    • /
    • 2016
  • The collapsing accidents of greenhouse frames have been increased yearly due to strong wind and heavy snow, but as it was, there were few studies about the structural safety of greenhouses. Therefore, this study was carried out to develop the stress tolerant structural frame systems in built-up greenhouses. The vertical loading experiment of developed scale models were implemented and the developed types of models were simulated by 3-D analysis program in this study. These types of models, which are existing type and honeycomb type, in arch and standard style frames were classified. As a result of this study, it was verified that the honeycomb type model of arch style frame is better than the existing type model of it in stress resistance against snow load and wind load.

The Experiment for Performance Evaluation of Column-rafter-purlin Connections of an Arch-type Plastic Multi-span Greenhouse (플라스틱 연동온실 기둥-서까래-도리 접합부의 성능 평가 실험)

  • Choi, Man-kwon;Ryu, Hee-ryong;Cho, Myeong-whan;Yu, In-ho;Kim, Seung-yu
    • Journal of Bio-Environment Control
    • /
    • v.29 no.4
    • /
    • pp.473-479
    • /
    • 2020
  • In this study, the structural experiment was conducted with two types of specimens to investigate the mechanical behavior of the column-rafter-purlin connection of an arch-type greenhouse under monotonic loading. Based on the experimental results, the flexural performance was analyzed for two types of connections, and connection classification was attempted. Type B showed 77% of flexural performance compared to Type A, and both types showed that the rigidity and flexural strength did not reach the level of the full rigid. The behavior of the column-rafter-purlin connection was dominated by local buckling due to deformation of the weld and fasteners. As a result of connection classification by AISC standard, both Type A and B connections showed a result that did not meet the rigid connection performance assumed during design, and were classified as simple connection. Therefore, the connection performance evaluation and classification results show that the greenhouse design should be made in consideration of connection performance and in order to design a reliable greenhouse structure, a study on establishing clear design standards for the greenhouse connection is necessary.