• Title/Summary/Keyword: arc simulation

Search Result 422, Processing Time 0.026 seconds

A Study on the Temperature Compensation of ASIC for AFCI (AFCI용 ASIC의 온도보상에 관한 연구)

  • Yang, Seung-Kook;Lee, Ju
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.12
    • /
    • pp.109-113
    • /
    • 2013
  • In order to avoid the electrical fire, AFCI(Arc Fault Cirruit Interrupter) has been obligated to be adopted in the United States of America since 2002. AFCI using line resistor of neutral trace needs to compensate the variation of the line resistance by temperature variation. In this paper, the ASIC including the temperature compensation circuit is implemented. The proposed implementation is verified by showing the effectiveness of an electric and a temperature characteristics for Arc signals by simulation results.

A Three-Phase 618 Structure SRM (3상 6/8극 SRM)

  • Lee Ju-Hyun;Lee Dong-Hee;Chen Hao;Ahn Jin-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2004.07a
    • /
    • pp.254-258
    • /
    • 2004
  • A three-phase 6/8 structure SRM (switched reluctance motor), the design and analysis of the motor are described. The range of the stator pole arc factor and the rotor pole arc factor of the motor are analyzed in the linear region. The optimum range of the stator pole arc factor and the turn-off angle of the main switches in the power converter are given with the 2-D finite element electro-magnetic field calculation of the motor and the nonlinear simulation. Test results of the prototype developed are discussed.

  • PDF

A Study on the Development of GUI Software using MATLAB (MATLAB을 이용한 GUI 소프트웨어 개발에 관한 연구)

  • Kim, B.C.;Kim, C.H.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.449-451
    • /
    • 2000
  • Arcing fault on overhead lines can be detected by amplitude of the arc voltage using numerical algorithm. In the case of transient fault, the arc voltage has any high value. In the case of permanent fault, the arc voltage is near zero. Thus, fault distance estimation should be performed by digital distance relay algorithm[3]. The purpose of this study is to build a structure for modeling of arcing fault detection and fault distance estimation algorithm using Matlab programming. Additionally, this algorithm has been designed in Graphical User Interface(GHI). So, this method using GUI interface of Matlab can reduce the number of simulation steps in modeling the distance relay.

  • PDF

Synchronized Two-Term mal Fault Location Technique for Adaptive Autoreclosure (적응 자동재폐로를 위한 동기식 2 단자 사고거리 추정기법)

  • Lee, Chan-Joo;Radojevic, Zoran;Kim, Hyun-Houng;Park, Jong-Bae;Shin, Joong-Rin
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.169-171
    • /
    • 2005
  • This paper presents a two-terminal approach for fault location estimation and for faults recognition. The proposed algorithm is also based on the synchronized phasors measured from the synchronized PMUs installed at two-terminals of the transmission lines. Also the arc voltage wave shape is modeled numerically on the basis of a great number of arc voltage records obtained by transient recorder. From the calculated arc voltage amplitude it can make a decision whether the permanent or transient fault. The results of the proposed algorithm testing through computer simulation are given.

  • PDF

An Analytical Solution for Transient Temperature Distribution in Fillet Arc Welding Including the Effect of Molten Metal (용착 금속을 고려한 필릿 용접에서 온도 분포 예측을 위한 해석적 모델)

  • 정선국;조형석
    • Journal of Welding and Joining
    • /
    • v.13 no.3
    • /
    • pp.116-124
    • /
    • 1995
  • This paper presents an analytical solution to predict the transient temperature distribution in fillet arc welding including the effect of molten metal. The solution is obtained by solving a transient three-dimensional heat conduction equation with convection boundary conditions on the surfaces of a plate, and mapping the infinite plate onto the fillet weld geometry with energy equation. The electric heat input on the fillet weld and on the infinite plate is assumed to have a combination of two bivariate Gaussian distribution. To check the validity of the solution. FCA welding experiments were performed under various welding conditions. The actual isotherms of the weldment cross-sections at various distances from the arc start point are compared with those of simulation result.

  • PDF

Automatic Seam Tracking for Plasma Arc Welding of a Corrugation Panel (파형부재의 플라즈마 아크용접을 위한 자동 용접선 추적)

  • Yang, Joo-Woong;Park, Young-Jun
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1506-1511
    • /
    • 2003
  • This paper describes an automatic weld seam tracking method of plasma arc welding system designed for the corrugation panel that consists of a linear section and a curved section with various curvatures. Due to the complexity of the panel shape, it is difficult to find a seam and operate a torch manually in the welding process. So, the laser vision sensor for seam tracking is designed for sensing the seam position and controlling a torch automatically. To achieve precise seam tracking, the design of sensor head, image simulation, and calibration are carried out. Through a series of experiment result, compensation algorithm is added and real time error compensation is achieved. The experiment result shows that this vision sensor works effectively. It will provide more precise welding performance and convenience to the operator.

  • PDF

Study on Design and Characteristic Analysiy of 6/8 SRM (6/8극 SRM의 설계 및 특성해석에 관한 연구)

  • Sohn Ick-Jin;Oh Seok-Gyu;Hao Chen;Ahn Jin-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.407-410
    • /
    • 2002
  • A three-phase 6/8 structure Switched Reluctance Motor drive, the construction of the stator and the rotor. in the motor, the scheme of the rotor position detector and the main circuit of the power converter are described. The range of the stator pole arc factor and the rotor pole arc factor of the motor are analyzed in the linear region. The optimum range of the stator pole arc factor and the optimum range of the turn-off angle of the main switches in the power converter are given with the 2-D finite element electro-magnetic field calculation of the motor and the nonlinear simulation. Test jesuits of the developed prototype are discussed.

  • PDF

Analysis of SLF Interruption Performance of Self-Blast Circuit Breaker by Means of CFD Calculation

  • Kim, Hong-Kyu;Chong, Jin-Kyo;Lee, Se-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.254-258
    • /
    • 2014
  • This paper presents the performance analysis results of a short line fault interruption of a gas circuit breaker, particularly a self-blast type breaker. Hot gas flow analysis was carried out using a CFD calculation combined with the arc model and nozzle ablation model. To evaluate the interruption performance, the index function was defined using the pressure in the heating chamber and the density above the arc region. The simulation and test results showed that the gas flow field and suitable choice of an interruption performance index can be used to predict the interruption characteristics and provide guidelines for designing self-blast breakers with a higher interruption capability.

Prediction of Arc Welding Quality through Artificial Neural Network (신경망 알고리즘을 이용한 아크 용접부 품질 예측)

  • Cho, Jungho
    • Journal of Welding and Joining
    • /
    • v.31 no.3
    • /
    • pp.44-48
    • /
    • 2013
  • Artificial neural network (ANN) model is applied to predict arc welding process window for automotive steel plate. Target weldment was various automotive steel plate combination with lap fillet joint. The accuracy of prediction was evaluated through comparison experimental result to ANN simulation. The effect of ANN variables on the accuracy is investigated such as number of hidden layers, perceptrons and transfer function type. A static back propagation model is established and tested. The result shows comparatively accurate predictability of the suggested ANN model. However, it restricts to use nonlinear transfer function instead of linear type and suggests only one single hidden layer rather than multiple ones to get better accuracy. In addition to this, obvious fact is affirmed again that the more perceptrons guarantee the better accuracy under the precondition that there are enough experimental database to train the neural network.

The Adequacy Analysis for Installation of High Speed Grounding Switches on the Korean 765kV Single Transmission Line

  • Ahn, Sang-Pil;Kim, Chul-Hwan;Park, Nam-Ok;Ju, Hyung-Jun;Shim, Eung-Bo
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.4
    • /
    • pp.427-434
    • /
    • 2006
  • This paper analyzes arc phenomena including the secondary arc's elongation in the Korean 765kV single transmission line (79km) between Sin-Ansung S/S and Sin-Gapyeong S/S, which will be installed in Korea in June 2006. In particular, both frequency independent and frequency dependent line models are compared to make our final decisions. As well, the significant simulation results are investigated by the EMTP program. As a result, there is no need of HSGS in the Korean 765kV single transmission line from both a practical and an economical point of view.