• Title/Summary/Keyword: arc function

Search Result 321, Processing Time 0.022 seconds

Minimization of Cogging Torque in Permanent Magnet Motors by Stator Pole Shoe Pairing and Magnet Arc Design using Genetic Algorithm (유전자 알고리즘을 이용한 영구자석 모터의 고정자 잇날 페어링 및 자석 극호각 설계에 의한 코깅 토오크의 저감 설계)

  • Eom, Jae-Bu;Hwang, Geon-Yong;Hwang, Sang-Mun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.1
    • /
    • pp.1-6
    • /
    • 2002
  • Cogging torque is often a principal source of vibration and acoustic noise in high precision spindle motor applications. In this paper, cogging torque is analytically calculated using energy method to show that Fourier spectra of airgap permeance function and airgap MMF function are the most important design parameters to control cogging torque. To control these functions, stator pole shoe pairing and magnet arc design are proposed to minimize cogging torque. As for optimization technique, genetic algorithm is applied to handle trade-off effects of design parameters. Results show that the proposed method can reduce the cogging torque effectively.

A Study on Energy Recovery Circuit in Sputtering Plasma Power supply for arc Discharge Prevention (스퍼터용 플라즈마 전원장치의 아크방지를 위한 에너지 회생회로에 대한 연구)

  • Ban, Jung-Hyun;Han, Hee-Min;Kim, Joohn-Sheok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.61 no.3
    • /
    • pp.116-121
    • /
    • 2012
  • Recently, in the field of renewable energy such as solar cells including the semiconductor and display industries, thin film deposition process is being diversified. Furthermore, to deal with trend of making high-quality and fast, the high-capacity and output plasma power supply which can control high density plasma is required. The biggest problem is arc discharge caused by using high voltage power supply. Thus, the key function of plasma power supply is to prevent arc discharge and there is a need to maintain the possible minimum arc energy. In DC sputtering power supply, on a periodic basis (-)voltage powering up is able to significantly reduce arcing, as well as arc discharge prevention, and maintaining uniform charge density. This conventional method for powering up (-)voltage requires heavy mutual inductance of the transformer to avoid distortion problem of the output voltage. This study is about energy recovery circuit for arc discharge prevention in sputtering plasma power supply. By using energy recovery circuit, it is possible to reduce the mutual inductance and size of the transformer dramatically, prevent distortion of the output voltage and has a stable output waveform. This work was proved through simulation and experimental study.

Modeling of Welding Heat Input for Residual Stress Analysis (용접 잔류응력 해석을 위한 Heat Input Model 개발)

  • 심용래;이성근
    • Journal of Welding and Joining
    • /
    • v.11 no.3
    • /
    • pp.34-47
    • /
    • 1993
  • Finite element models were developed for thermal and residual stress analysis for the specific welding problems. They were used to evaluate the effectiveness of the various welding heat input models, such as ramp heat input function and lumped pass models. Through the parametric studies, thermal-mechanical modeling sensitivity to the ramp function and lumping techniques was determined by comparing the predicted results with experimental data. The kinetics for residual stress formation during welding can be developed by iteration of various proposed mechanisms in the parametric study. A ramp heat input function was developed to gradually apply the heat flux with variable amplitude to the model. This model was used to avoid numerical convergence problems due to an instantaneous increase in temperature near the fusion zone. Additionally, it enables the model to include the effect of a moving arc in a two-dimensional plane. The ramp function takes into account the variation in the out of plane energy flow in a 2-D model as the arc approaches, travels across, and departs from each plane under investigation. A lumped pass model was developed to reduce the computation cost in the analysis of multipass welds. Several weld passes were assumed as one lumped pass in this model. Recommendations were provided about ramp lumping techniques and the optimum number of weld passes that can be combined into a single thermal input.

  • PDF

Study on the Pulmonary Function in Welding Fume Exposed Workers (용접흄 폭로 근로자들의 폐기능에 관한 연구)

  • Hong, Young-Seoub;Kim, Byoung-Gwon;Kim, Sung-Ryul;Dam, Do-Won;Kim, Jung-Man;Jung, Kap-Yull;Kim, Joon-Youn
    • Journal of Preventive Medicine and Public Health
    • /
    • v.28 no.1 s.49
    • /
    • pp.43-57
    • /
    • 1995
  • In order to study the effect of welding fume exposure upon the pulmonary function test, we examined 131 shielded arc welding workers, and 152 $CO_2$ arc welding workers as cases and 177 control workers for their general characteristics, and forced vital capacity (FVC), forced expiratory volume in one second $(FEV_{1.0})$, forced expiratory volume in one second as a percent of FVC $(FEV_{1.0}%)$, and maximal mid-expiratory flow (MMF) were obtained from the spirogram. In shielded arc welding group and $CO_2$ arc welding group, FVC, $FEV_{1.0},\;FEV_{1.0}%$, and MMF were significantly decreased than control group, especially marked in the MMF finding. The distribution of workers below normal range was as follows. in the shielded arc welding group, 2 workers(1.5%) for FVC, 17 workers(13.0%) for $FEV_{1.0}$, 5 workers(3.8%) for $FEV_{1.0}%$, 28 workers(21.4%) for MMF, and in the $CO_2$ arc welding group, 3 workers(2.0%) for FVC, 25 workers(16.4%) for $FEV_{1.0}$, 8 workers(5.3%) for $FEV_{1.0}%$, and 37 workers(24.3%) for MMF, and significant increase by exposure duration was found in MMF. The distribution of workers who had ventilation impairment was as follows: 5 workers(3.8%) for obstructive type, 2 workers(1.5%) for restrictive type in the shielded arc welding group, and 7 workers(4.6%) for obstructive type, 2 workers(1.3%) for restrictive type, and 1 worker(0.6%) was combined type of the $CO_2$ arc welding group. In the respect of these results, the significant pulmonary function and ventilatory impairment were observed in welding fume exposed workers who had not abnormal finding in chest X-ray, and MMF considered as the most sensitive pulmonary function index by welding fume exposure. Therefore even if it is hard to doing pulmonary function test in the first health examination of workers according to the Industrial Safety Health Act in the welding fume exposure workers, it is desirable to consider doing PFT. Also evaluating the ventilation impairment, it is necessary, to observe the change of MMF that marker of effort-independent portion.

  • PDF

Wear Behaviors of Ceramics TIN, TIC and TICN with Arc Ion Plating

  • Oh, Seong-Mo;Rhee, Bong-Goo;Jeong, Bong-Soo
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.12
    • /
    • pp.1904-1911
    • /
    • 2003
  • In order to determine the wear properties of AIP (Arc Ion Plating) deposition, wear process was evaluated by using a Falex test machine. Also, in order to determine the effects of coating material on the wear process, TiC, TiN, and TiCN coatings of thickness about 5 $\mu\textrm{m}$∼6 $\mu\textrm{m}$ coated by Arc ion plating deposition method were tested. The wear property was determined under a dry sliding condition as a function of the applied load, sliding distance, sliding velocity and temperature. The results show that when wear of the coating-layer occurred, specific wear amount increased with the wear rate. At initial state, the wear rate rapidly increased, but it gradually reduced as the velocity increased. Also, when raising the temperature, the wear rate increased in the order of TiCN, TiN and TiC due to the frictional heat.

Evalution of Current interrupting capability in GCB by computational approach (전산수치해석을 통한 가스차단기의 차단성능 평가)

  • Choi, Y.K.;Lee, K.S.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1677-1681
    • /
    • 2002
  • A computational approach of the arc quenching process in GCB was developed. it is capable to calculates the thermodynamic quantities of the gas as a function of time taking into account of all spaces concerned with the arc quenching. Basically using so-called FLIC method, this program adoptes 'Simplified Enthalpy Arc Model', which is somewhat modified. And, to examine whether our works were done properly, it was simulated the whole process of the arc quenching that is based on self-flow generation phenomena/current interruption in a thermal expansion type circuit breaker. This program was verified by experiments, both showed fairly good agreement.

  • PDF

Development of a High Speed Rotating Arc Sensor System for Tracking Complicate Curved Fillet Welding Lines

  • Lee, Gun-You;Oh, Myung-Suck;Kim, Sang-Bong
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.4 no.6
    • /
    • pp.20-28
    • /
    • 2003
  • This paper presents development of a high speed rotating arc sensor system using a microprocessor based controller with tracking function for a complicate curved fillet welding line, The welding tip connected to the torch body is eccentrically positioned from the centerline of the torch, The area during one rotating cycle is divided into 4 regions of front, rear, right and left in welding direction of the torch tip to determine the horizontal deviation between the welding seam and the torch position. The average value at each region is calculated using the regional current values and a low pass filter incorporated with the moving average method is implemented. The effectiveness of the developed system is proven through the experimental results for several kinds of complicate curved fillet welding lines.

Arc current Controller design for Arc currant interruption (Arc 전류 차단을 위한 제어기 설계)

  • Ban, Gi-Jong;Cho, Jun-Suk;Han, Hong-Kyun;Nam, Mun-Hyun;Kim, Lark-Kyo
    • Proceedings of the KIEE Conference
    • /
    • 2002.07d
    • /
    • pp.2073-2075
    • /
    • 2002
  • In this paper, are current controller is designed for the interruption of are fault current which is occurred in the low voltage network. Are in electrical network have the characteristics of low current, high impedance and high frequency. Conventional controller does not have the are current interrupt function. Hence, in this paper are current controller is designed for the interruption of arc fault current.

  • PDF

Proper Arc Welding Condition Derivation of Auto-body Steel by Artificial Neural Network (신경망 알고리즘을 이용한 차체용 강판 아크 용접 조건 도출)

  • Cho, Jungho
    • Journal of Welding and Joining
    • /
    • v.32 no.2
    • /
    • pp.43-47
    • /
    • 2014
  • Famous artificial neural network (ANN) is applied to predict proper process window of arc welding. Target weldment is variously combined lap joint fillet welding of automotive steel plates. ANN's system variable such as number of hidden layers, perceptrons and transfer function are carefully selected through case by case test. Input variables are welding condition and steel plate combination, for example, welding machine type, shield gas composition, current, speed and strength, thickness of base material. The number of each input variable referred in welding experiment is counted and provided to make it possible to presume the qualitative precision and limit of prediction. One of experimental process windows is excluded for predictability estimation and the rest are applied for neural network training. As expected from basic ANN theory, experimental condition composed of frequently referred input variables showed relatively more precise prediction while rarely referred set showed poorer result. As conclusion, application of ANN to arc welding process window derivation showed comparatively practical feasibility while it still needs more training for higher precision.

Augmented renal clearance

  • Atkinson, Arthur J. Jr.
    • Translational and Clinical Pharmacology
    • /
    • v.26 no.3
    • /
    • pp.111-114
    • /
    • 2018
  • Adding to the complexity of caring for critically ill patients is the fact that many of them have a creatinine clearance that exceeds $130mL/min/1.73m^2$. This phenomenon, termed augmented renal clearance (ARC), has only recently been widely recognized and its pathogenesis remains incompletely understood. However, ARC has been shown to result in increased dose requirements for drugs that are primarily eliminated by renal excretion, including many antimicrobial agents and enoxaparin. Recognition of ARC is hampered by the fact that the standard creatinine-based equations used to estimate renal function are not accurate in this clinical setting and the diagnosis is best established using both serum and urine creatinine measurements to calculate clearance. So a high index of clinical suspicion and awareness is usually required before this step is taken to confirm the diagnosis of ARC.