• Title/Summary/Keyword: apron

Search Result 217, Processing Time 0.024 seconds

The Evaluation of Performance and Usability of Bismuth, Tungsten Based Shields (비스무스, 텅스텐 기반 차폐체의 성능 및 유용성 평가)

  • Park, Hoon-Hee
    • Journal of radiological science and technology
    • /
    • v.41 no.6
    • /
    • pp.611-616
    • /
    • 2018
  • Lead apron is harmful to the human body because it is made at heavy metals, and when worn for long periods of time, it causes pain. Therefore, this paper intended to improve the defects of lead apron by using new material shields. For the comparative evaluation of lead and new material shieldes, the shielding rate and weight were measured and tested based on lead 0.5 mmPb. The rate of shielding was 97% based on lead at 0.5 mm thickness, while The new material shield T3 showed similar shielding rates as lead in 8 layers, and in T2 these values were measured in 11 layers. In addition, similar shielding rate was measured in 12 layers at B2, and 8 layers in BF, and 4 layers in $BF_2$. Comparing the weight of cases when commercialized with apron, T3, T2 and B2 were heavier than lead apron. But BF, $BF_2$ were lighter than the lead apron. Based on the results of the experiment, T3 and T2 can be used as an alternative to lead if human or environmental hazards are considered a priority. However, BF and $BF_2$ should be used if the reduction of external exposure is considered a priority.

Stability of River Bed Protection Works (하상보호공의 안정성)

  • Cho, Jae-Woong;Park, Sang-Duck;Shin, Seung-Suk;Hing, Jong-Sun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.519-523
    • /
    • 2008
  • 하천의 보와 같은 횡방향 구조물은 홍수시 구조물에 의한 세굴이 발생하고, 그로인해 구조물의 불안정을 초래한다. 본 연구에서는 apron 하류에 하상보호공을 설치하였을 때 하상보호공의 안정성과 하류의 세굴양상에 대해 연구하였다. Apron 상류로부터 유사의 유입이 없도록 apron 하류에 체결된 블록을 설치한 개수로에서 블록의 설치길이와 채움재를 변화시켜 수리모형 실험을 실시하여 블록의 설치길이와 채움재에 따른 안정성과 하류세굴양상을 평가하였다. Apron하류의 블록 내부에서 세굴 깊이는 블록의 설치길이, 채움재의 직경, 유량, Reynolds 수, Froude 수 등에 따라 달라진다. 세굴에 대한 블록의 안정성은 블록의 설치길이와 채움재의 직경에 가장 큰 영향을 받는다. 블록의 설치 길이와 채움재의 직경을 증가시킴으로써 블록의 안정성을 확보할 수 있다. 실험결과 블록의 설치길이가 13.35m이상일 때 블록의 안정성이 확보될 수 있는 것으로 나타났다.

  • PDF

Improvement of shieldability and lightweight of radiation protective apron (방사선 방호용 에이프런의 경량화와 차페능 개선)

  • Kim, Chang-Bok;Kim, Young-Keun;Ku, Hal-Bon;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.04b
    • /
    • pp.105-110
    • /
    • 2004
  • 방사선 투시조영 촬영 시 사용되는 방호복의 차폐효율 증가와 경량화는 오랜 시간 연구 대상이 되었다. 이러한 방호복의 질적 향상을 위하여 연구한 결과는 다음과 같다. Apron의 규격인 납 당량 0.25mm에 해당하는 투과선량은 5.2%로 나타났으며, 시료 Sn, Ni, Ti, Cu의 방사선 차폐 효율은 Sn이 가장 높게 나타났다. 증착시료 Sn+Pb 방법에서는 Sn 0.18mm와 Pb 0.1mm, Pb+Sn 방법에서는 Pb 0.1mm와 Sn 0.36mm에서 Apron의 규격인 납 0.25mm 두께로 나타났다. 증착시료 Sn+Pb는 Apron의 규격인 0.25mm 납 당량보다 차폐효율이 높고, 면적당 무게가 가벼워 방호복 물질로 적합한 것으로 사료된다.

  • PDF

Numerical Modeling on the Change in Discharge Performance of the Sluice for Tidal Power Plant According to the Apron Shape (물받이 형상에 따른 조력발전용 수문의 통수성능 변화 수치모델링)

  • Oh, Sang-Ho;Han, In-Suk;Kim, Gunwoo;Jeong, Weon-Mu
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.25 no.2
    • /
    • pp.94-102
    • /
    • 2013
  • In this study, numerical modeling was performed to investigate influence of the apron shape on the discharge performance of the sluice for tidal power plant. The numerical modeling was carried out for comparison of the difference in the discharge coefficient when the apron width, slope, and the length of the horizontal section were different, without considering change in the shape of the sluice caisson itself. The modeling result showed that significant discrepancy in terms of the overall discharge performance appeared according to the apron geometry. In order to achieve maximum discharge performance of the sluice caisson, it is desirable to make the design by putting a space equivalent to the width of the sluice caisson on its both sides, by making the apron slope be 1:5, and by keeping length of the horizontal section to be 50 m that is corresponding to the streamwise length of the sluice caisson.

Consideration on Shielding Effect Based on Apron Wearing During Low-dose I-131 Administration (저용량 I-131 투여시 Apron 착용여부에 따른 차폐효과에 대한 고찰)

  • Kim, Ilsu;Kim, Hosin;Ryu, Hyeonggi;Kang, Yeongjik;Park, Suyoung;Kim, Seungchan;Lee, Guiwon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.32-36
    • /
    • 2016
  • Purpose In nuclear medicine examination, $^{131}I$ is widely used in nuclear medicine examination such as diagnosis, treatment, and others of thyroid cancer and other diseases. $^{131}I$ conducts examination and treatment through emission of ${\gamma}$ ray and ${\beta}^-$ ray. Since $^{131}I$ (364 keV) contains more energy compared to $^{99m}Tc$ (140 keV) although it displays high integrated rate and enables quick discharge through kidney, the objective of this study lies in comparing the difference in exposure dose of $^{131}I$ before and after wearing apron when handling $^{131}I$ with focus on 3 elements of external exposure protection that are distance, time, and shield in order to reduce the exposure to technicians in comparison with $^{99m}Tc$ during the handling and administration process. When wearing apron (in general, Pb 0.5 mm), $^{99m}Tc$ presents shield of over 90% but shielding effect of $^{131}I$ is relatively low as it is of high energy and there may be even more exposure due to influence of scattered ray (secondary) and bremsstrahlung in case of high dose. However, there is no special report or guideline for low dose (74 MBq) high energy thus quantitative analysis on exposure dose of technicians will be conducted based on apron wearing during the handling of $^{131}I$. Materials and Methods With patients who visited Department of Nuclear Medicine of our hospital for low dose $^{131}I$ administration for thyroid cancer and diagnosis for 7 months from Jun 2014 to Dec 2014 as its subject, total 6 pieces of TLD was attached to interior and exterior of apron placed on thyroid, chest, and testicle from preparation to administration. Then, radiation exposure dose from $^{131}I$ examination to administration was measured. Total procedure time was set as within 5 min per person including 3 min of explanation, 1 min of distribution, and 1 min of administration. In regards to TLD location selection, chest at which exposure dose is generally measured and thyroid and testicle with high sensitivity were selected. For preparation, 74 MBq of $^{131}I$ shall be distributed with the use of $2m{\ell}$ syringe and then it shall be distributed after making it into dose of $2m{\ell}$ though dilution with normal saline. When distributing $^{131}I$ and administering it to the patient, $100m{\ell}$ of water shall be put into a cup, distributed $^{131}I$ shall be diluted, and then oral administration to patients shall be conducted with the distance of 1m from the patient. The process of withdrawing $2m{\ell}$ syringe and cup used for oral administration was conducted while wearing apron and TLD. Apron and TLD were stored at storage room without influence of radiation exposure and the exposure dose was measured with request to Seoul Radiology Services. Results With the result of monthly accumulated exposure dose of TLD worn inside and outside of apron placed on thyroid, chest, and testicle during low dose $^{131}I$ examination during the research period divided by number of people, statistics processing was conducted with Wilcoxon Signed Rank Test using SPSS Version. 12.0K. As a result, it was revealed that there was no significant difference since all of thyroid (p = 0.345), chest (p = 0.686), and testicle (p = 0.715) were presented to be p > 0.05. Also, when converting the change in total exposure dose during research period into percentage, it was revealed to be -23.5%, -8.3%, and 19.0% for thyroid, chest, and testicle respectively. Conclusion As a result of conducting Wilcoxon Signed Rank Test, it was revealed that there is no statistically significant difference (p > 0.05). Also, in case of calculating shielding rate with accumulate exposure dose during 7 months, it was revealed that there is irregular change in exposure dose for inside and outside of apron. Although the degree of change seems to be high when it is expressed in percentage, it cannot be considered a big change since the unit of accumulated exposure dose is in decimal points. Therefore, regardless of wearing apron during high energy low dose $^{131}I$ administration, placing certain distance and terminating the administration as soon as possible would be of great assistance in reducing the exposure dose. Although this study restricted $^{131}I$ administration time to be within 5 min per person and distance for oral administration to be 1m, there was a shortcoming to acquire accurate result as there was insufficient number of N for statistics and it could be processed only through non-parametric method. Also, exposure dose per person during lose dose $^{131}I$ administration was measured with accumulated exposure dose using TLD rather than through direct-reading exposure dose thus more accurate result could be acquired when measurement is conducted using electronic dosimeter and pocket dosimeter.

  • PDF

Evaluation of the Shielding Effect of Lead Apron according to the Energy Spectrum Change of 99mTc (99mTc의 에너지 스펙트럼 변화에 따른 납 앞치마의 차폐 효과 평가)

  • Changyong Yoon;Youngsik Ji
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.889-896
    • /
    • 2023
  • Changes in the energy spectrum were analyzed using 99mTc as a point source and a scattering phantom, and the shielding effect of the lead apron according to the changed gamma ray energy was evaluated. In the gamma ray energy spectrum of the scattering phantom, the photo peak area decreased and the compton scattering area increased compared to the point source. The coefficients for each energy range according to the change in the shape of the gamma ray source showed a reduction rate of up to 66.1 % at a distance of 20 cm compared to the coefficient of the point source, and in the compton scattering area, the coefficient of the scattering phantom was 122.2 % at a distance of up to 40 cm compared to the coefficient of the point source. In the difference in shielding rate according to the distance between the source and the scattering phantom using a gamma camera, the photo peak area showed similar results, but in the Compton scattering area, the shielding rate of the scattering phantom at a distance of 20 cm increased by 29.2 % compared to the shielding rate of the point source. As the distance increased, the difference in shielding rate decreased. In measuring the shielding rate of the lead apron using a radiation dosimeter, the difference in the shielding rate of the scattering phantom was up to 15.3 %, and as the distance increased, the difference in the shielding rate between the two sources decreased. The shielding rate of the lead apron of the scattering phantom is higher than that of the point source, and the effectiveness of the lead apron increases as the distance to the source increases. As a result, wearing a lead apron when directly confronting a patient who has injected radioactive pharmaceuticals is expected to be helpful in reducing radiation exposure.

A Study on the Gonads Exposure Dose of Upper Extremity Examinations in Sitting Position (앉은 자세 상지 X-ray 검사(Sitting Position Upper Extremity X-ray Examinations)에서 피폭선량 저감화 연구)

  • Cho, Pyong-Kon
    • Journal of radiological science and technology
    • /
    • v.34 no.3
    • /
    • pp.189-193
    • /
    • 2011
  • Sitting position upper extremity X-ray examinations (SUEX) is the most widely used patient positioning method for upper extremity X-ray examinations. For this method, the radiation dose is considerable for relatively less interesting organs. We investigated whether patients need to wear the apron during the examination or not. We also studied the examination methods which can reduce the radiation dose. The results showed that radiation dose was reduced as the distance of source to patient becomes longer and the thickness of object grows higher.

A Study on the Indirect Radiation Exposure of the Medical Personnel Who is Responsible for Patient Safety in CT Examination (전산화단층촬영검사 시 검사실 내에 위치할 수 있는 의료인의 간접 피폭선량에 대한 연구)

  • Choi, Min-Hyeok;Jang, Ji-Sung;Lee, Ki-Baek
    • Journal of radiological science and technology
    • /
    • v.42 no.2
    • /
    • pp.105-111
    • /
    • 2019
  • A medical personnel could be placed beside a patient together in CT room to do Ambu-bag for a seriously ill patients or emergency patient. At this time, the medical personnel can be exposed indirect radiation unnecessarily. In this case, it is necessary to recognize indirect radiation dose levels and methods to reduce them using actual clinical CT protocols such as Chest, Abdomen, and Brain CT. We researched surface radiation dose with or without radiation protectors such as apron and goggles according to different distances far from gantry using two different CT scanners (Fixed MDCT and mobile CT). As a result, for Chest, Abdomen, and Brain CT with Fixed MDCT, indirect radiation dose on thorax portion were 0.047, 0.089, 0.034 mSv without apron. Also, those with apron were 0.007, 0.012, 0.006 mSv. In case of mobile CT, it was 0.014 mSv without apron and 0.005 mSv with apron. By using protectors and increasing the distance, we could reduce it to 97%. Systematic management is necessary based on the measured data in order to minimize radiation damage due to indirect exposure dose.

Memory Optimization of Separable Filter Using GPGPU (GPGPU를 이용한 분리형 필터의 메모리 최적화)

  • Jung, Yun-Hye;Kim, Jin-Woo;Park, Yong-Jin;Han, Tack-Don
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2011.04a
    • /
    • pp.534-537
    • /
    • 2011
  • 분리형 필터는 메모리 접근 및 연산량을 O($N^2$)에서 O(N)으로 최적화하는 기법이다. GPGPU를 이용한 필터기반의 영상처리에 분리형 필터를 적용하면 2차원 apron 영역이 2개의 1차원 apron 영역으로 이 되기 때문에 메모리 최적화 측면에서 유리하다. 본 논문은 GPGPU를 이용한 분리형 필터에 슬라이딩 윈도우 형태의 지역 메모리 관리 기법을 적용하여 apron 발생을 최소화하는 구조를 제안하고 실험을 통해 저성능 메모리 환경에서 최대 17.9% 성능향상이 있었으며, 메모리 성능이 50% 낮아지는 경우에도 전체성능 감소도 최대 9%수준으로 안정적임을 확인하였다.

A Study on Practice of Infection Control by Dental Hygienists -With Reference to Seoul and Incheon·Gyeonggi Province- (치과위생사의 감염방지 실천 정도에 관한 연구 - 서울 및 인천·경기도를 중심으로-)

  • Park, Hyang-Sook;Choi, Jung-Young;Sim, Su-Hyun;Kim, Jin-Soo;Choi, Boo-Keun;Jang, Hee-Kyung
    • Journal of dental hygiene science
    • /
    • v.8 no.4
    • /
    • pp.275-281
    • /
    • 2008
  • Background: This research aims to provide basic data for dental hygienists to implement the infection control after understanding the level of their implementation of infection control in case they have been trained of infection control or not. Method: The respondents in this research are the dental hygienists who worked in the Incheon or Gyeonggi areas between June 16 and July 5, 2008 and who attended complementary training conducted by the Seoul Branch of Korean Dental Hygienists Association in April 2008. A total of 191 questionnaires were distributed to them, and the frequency of the collected data was analyzed using SPSS WIN 12.0. Moreover, cross-tabulation analysis (${\chi}^2$) whose significance level was 0.05, was applied to the data in order to verify the statistical significance of the survey method. Result: There was significant difference in their practice to wear gloves and/or a mask, use a disposable apron and the time to change the apron depending upon the respondents' workplace. There was significant difference in the time to change their apron depending upon the respondents' time of service. 91.6% had been trained in the infection control: of them, 70.7% trained at their school. It was found that 68.6% of the respondents who had been trained in the infection control would wash their hands before treating a patient. 50.3% of the respondents who had been trained in the prevention of contamination would wear their gloves as needed for a basic treatment. Conclusion: Considering the above results of this research, it is concluded that it is necessary to provide practicing dental hygienists with many opportunities for systematic and practical training so that they may faithfully follow the guidelines for the prevention of contamination and to encourage hospitals to have a greater store of relevant facilities, equipment and supplies.

  • PDF