• Title/Summary/Keyword: approximately continuous

Search Result 351, Processing Time 0.028 seconds

Emergency Reexploration for Bleeding after Open Heart Surgery wth Cardiopulmonary Bypass -A Report of 16 Cases- (개심술후 출혈로 인한 응급개흉술의 임상적 고찰)

  • 유재현
    • Journal of Chest Surgery
    • /
    • v.24 no.11
    • /
    • pp.1068-1073
    • /
    • 1991
  • Bleeding after open heart surgery with cardiopulmonary bypass was a cause of concern. requiring reexploration of the chest in approximately 8 percent of patients who have had operations on the heart. From April., 1983 to October, 1991, 16 patients[2%] out of 777 patients who underwent open cardiac surgery had emergency reexploration with bleeding at the Department of Thoracic and Cardiovascular Surgery, Chungnam National University Hospital. In 12 cases[75%], reexploration was performed for continuous bleeding and the reminder[4 cases] were performed for suspected tamponade & hypotension. There were 9 cases[56%] of congenital heart disease and 7 cases of acquired heart disease. The mean blood loss were 997$\pm$472ml /sq. M in total cases and 1442$\pm$ 647ml /sq. M in cases repair of cyanotic heart disease. The mean interval till reoperation was 16.6hr [1hr~72hr] and 41 hr[12~72hr] in tamponade cases and 8.4hr[1hr~24hr] in continuous bleeding cases. The bleeding sites were identified in 7 cases: aortotomy site in 2 cases, ventriculotomy site, SVC, thymus, pleura and sternum wiring site in each other case. But no specific sites was found in the remaining 9 cases. The 8 cases had complications but all except 1 cases with hypoxic brain damage were recovered without sequale. We conclude that emergency thoractomy after open heart surgery may be lifesaving and-/or diminishing complications with bleeding if performed promptly with excessive bleeding, tamponade and unexpected hypotension.

  • PDF

Development of Carbon Continuous-fiber Composite Frame for Automotive Sun-roof Assembly (자동차용 탄소 연속섬유 복합재 선루프 프레임의 개발에 대한 연구)

  • Kim, Jinbong;Kim, Kyoung-Deok;Kim, Sungjin;Shin, Dongwan;Kim, Dukki
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.25 no.3
    • /
    • pp.350-359
    • /
    • 2017
  • This paper presents a new holistic development approach for the carbon continuous-fiber composite frame of an automotive sunroof assembly. The original steel frame has been designed to get higher bending stiffness with its corrugated cross-sectional shape. The new approach uses the prepregs of a fast cure epoxy and PCM manufacturing processing. For higher productivity, the new frames feature a very simple plat cross sectional shape but achieve high bending stiffness through the laminate design. The sandwich structure with a PET foam core was presented. The frames were made of carbon UD laminae covered single carbon fabric on the outer surfaces. The fabrics provide torsional stiffness and also hold the carbon UD fibers floating in the low viscous epoxy resin of prepregs at the curing temperature during processing. The final product yields approximately 18 % savings in weight compared with the original.

Degradation of Monoethanolamine during Continuous Operation of a Laboratory Scale CO2 Absorption System (실험실 규모 이산화탄소 흡수장치의 연속운전시 모노에탄올아민 열화 특성)

  • Kang, Ji-A;Woo, Wongu;Lim, Ho-Jin
    • Journal of Environmental Science International
    • /
    • v.25 no.3
    • /
    • pp.385-393
    • /
    • 2016
  • Oxidative and thermal degradation of alkanolamines for a promising $CO_2$ capture technology of absorption might cause decrease in $CO_2$ capture efficiency and formation of hazardous byproducts. In this study, characteristics of a representative absorbent of monoehtanolamine (MEA) were examined for a long term operation using a laboratory scale absorption system. An $CO_2$ absorption system with ID 56 mm and absorption zone height 100 cm was developed for the characterization. Absorption solution of 30 wt% MEA was circulated at 100 mL/min to treat air with 15% $CO_2$ and 1 ppm NO at 10 L/min. Temperatures of absorber and stripper were maintained at $40^{\circ}C$ and $120^{\circ}C$, respectively. For the course of 5 weeks continuous operation, MEA concentration was decreased approximately by 70% and $CO_2$ removal efficiency was dropped from 95% to 65%. Ionic byproducts of $NH_4{^+}$, $NO_2{^-}$, and $NO_3{^-}$ were accumulated up to 48 g/mL, 0.2 g/mL, and 1.5 g/mL, respectively, tracking the variation of MEA concentration. Formation of various organic byproducts were also observed.

Designing a Vibrotactile Reading System for Mobile Phones

  • Chu, Shaowei;Zhu, Keying
    • Journal of Information Processing Systems
    • /
    • v.14 no.5
    • /
    • pp.1102-1113
    • /
    • 2018
  • Vibrotactile feedback is widely used in designing non-visual interactions on mobile phones, such as message notification, non-visual reading, and blind use. In this work, novel vibrotactile codes are presented to implement a non-visual text reading system for mobile phones. The 26 letters of the English alphabet are formed in an index table with four rows and seven columns, and each letter is mapped using the codes of vibrations. Two kinds of vibrotactile codes are designed with the actuator's on and off states and with specific lengths (short and long) assigned to each state. To improve the efficiency of tactile perception and user satisfaction, three user experiments are conducted. The first experiment explores the maximum number of continuous vibrations and minimum vibration time of the actuator's on and off states that the human can perceive. The second experiment determines the minimum interval between continuous vibrations. The vibrotactile reading system is designed and evaluated in the third experiment according to the results of the two preceding experiments. Results show that the character reading accuracy reaches 91.7% and the character reading speed is approximately 617.8 ms. Our method has better reading efficiency and is easier to learn than the traditional Braille coding method.

Cultivation of Spirulina platensis Using Pig Wastewater in a Semi-Continuous Process

  • Chaiklahan, Ratana;Chirasuwan, Nattayaporn;Siangdung, Wipawan;Paithoonrangsarid, Kalyanee;Bunnag, Boosya
    • Journal of Microbiology and Biotechnology
    • /
    • v.20 no.3
    • /
    • pp.609-614
    • /
    • 2010
  • The effluent from anaerobic digestion contains organic nitrogen and phosphorus, which are both required for growth of Spirulina platensis. Effluent (20%) from the upflow anaerobic sludge blanket (UASB) from a pig farm, supplemented with 4.5 g/l sodium bicarbonate ($NaHCO_3$) and 0.2 g/l urea fertilizer (46:0:0, N:P:K), was found to be not only a suitable medium for the growth of Spirulina platensis but also a low-cost alternative. Cost calculation showed that this medium is 4.4 times cheaper than modifized Zarrouk's medium. The average productivities of a semi-continuous culture grown under outdoor conditions in a 6-1 scale and a 100-1 pilot scale were 19.9 $g/m^2/d$ and 12 $g/m^2/d$, respectively. In addition, the biomass of organisms grown in UASB effluent contained approximately 57.9% protein, 1.12% $\gamma$-linolenic acid, and 19.5% phycocyanin. The average rates of bicarbonate, total nitrogen, and phosphorus removal were 380 mg/l/d, 34 mg/l/d, and 4 mg/l/d, respectively.

Cultivation of Lactobacillus crispatus KLB46 Isolated from Human Vagina

  • Chang, Chung-Eun;Kim, Seung-Cheol;So, Jae-Seong;Yun, Hyun-Shik
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.6 no.2
    • /
    • pp.128-132
    • /
    • 2001
  • Bacterial vaginosis can be treated by restoring the normal vaginal flora using lactobacilli. Lactobacillus crispatus KLB46 that was isolated from the human vagina has a string antimicrobial activity and was grown in a batch and in a continuous fermentor. During batch cultivation, the maximum specific growth rate of L. crispatus KLB 46 was 0.63h(sup)-1 and the highest viable cell count (1.9$\times$10(sup)9 CFU/mL) was obtained at pH 5.5. L. crispatus KLB 46 did not grow well at either pH 3.5 or 7.5. During continuous cultivation, the highest viable cell count (1.53$\times$10(sup)9 CFU/mL) was obtained at a dilution rate of 0.32h(sup)-1, and was 7.33$\times$10(sup)11 CFU L(sup)-1 h(sup)-1, that is approximately 5 times higher than that obtained from batch culture.

  • PDF

Heat Transfer Enhancement in a Divergent Passage with 30° Inclined Ribs (30° 경사 리브가 있는 확대 채널 통로 내의 열전달 증가)

  • Lee, Myung Sung;Ahn, Soo Whan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.8
    • /
    • pp.401-407
    • /
    • 2017
  • The effect of different rib geometries such as V-shaped continuous (case A), parallel broken (case B), and V-shaped broken (case C) ribs on local heat transfer distributions and pressure drops in a divergent channel with $30^{\circ}$ inclined ribs on one wall or two walls was investigated for Reynolds numbers from 22,000 to 75,000. Top and bottom walls were insulated; two side walls were uniformly heated in the divergent channel. Heated walls were composed of 10 isolated coper sections and length-to-outlet hydraulic diameter ratio of 10. Rib height-to-outlet hydraulic diameter ratio was 0.1, and rib pitch-to-height ratio equaled 10. Results revealed that V-shaped continuous rib (case A) produced approximately 1.4 times higher average Nussselt number than in the parallel broken rib (case B), and V-shaped broken rib (case C) in the channel with two ribbed walls at Re = 54,000.

Factors affecting nitrite build-up in an intermittently decanted extended aeration process for wastewater treatment (하수처리를 위한 간헐 방류식 장기폭기 공정에서 아질산염의 축적에 영향을 미치는 인자)

  • Ahn, Kyu-Hong;Park, Ki-Young;Lee, Hyung-Jib
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.13 no.1
    • /
    • pp.51-60
    • /
    • 1999
  • An intermittently-aerated, intermittently-decanted single-reactor process (KIDEA process : KIST intermittently decanted extended aeration process) was applied for nitrogen removal from wastewater. Synthetic wastewater with chemical oxygen demand (COD): nitrogen (N) ratio of approximately 5.25: 1 was used. The average COD removal efficiency reached above 95%, and under optimal conditions nitrogen removal efficiency also reached above 90%. This process consisted of 72 minute aeration, 48 minute settling and 24 minute effluent decanting with continuous feeding of influent wastewater from the bottom of the reactor, and did not require a separate anoxic mixing-phase. In this process, nitritation ($1^{st}$ step of nitrification) was induced but nitratation($2^{nd}$ step of nitrification) was suppressed. Main factors responsible for the accumulation of nitrite ion in the experimental condition were free ammonium and dissolved oxygen. This condition of nitrite build-up accelerated by continuous feed flow in the bottom of the KIDEA reactor because of high concentration of ammonia nitrogen in the influent. This research provides one of answers to control nitrate build-up.

  • PDF

Removal of sulfate ion from semiconductor wastewater by ettringite precipitation

  • Chung, Chong-Min
    • Membrane and Water Treatment
    • /
    • v.13 no.4
    • /
    • pp.183-189
    • /
    • 2022
  • This study seeks towards an optimal way to control sulfate ions in semiconductor wastewater effluent with potential eco-toxicity. We developed a system based on ettringite (Ca6Al2(SO4)3(OH)12·26H2O). The basic idea is that the pH of the water is raised to approximately 12 with Ca(OH)2. After, aluminium salt is added, leading to the precipitation of ettringite. Lab-scale batch and continuous experiment results with real semiconductor wastewater demonstrated that 1.5 and 1 of stoichiometric quantities for Ca2+ and A3+ with pH above 12.7 could be considered as the optimal operation condition with 15% of sludge recycle to the influent. A mixed AlCl3 + Fe reagent was selected as the beneficial Al3+ source in ettringite process, which resulted in 80% of sludge volume reduction and improved sludge dewaterability. The results of continuous experiment showed that with precipitation as ettringite, sulfate concentration can be stably reduced to less than 50 mg/L in effluent from the influent 2,050 ± 175 mg/L on average (1,705 ~ 2,633 mg/L).

Fabrication and Optimization of Mesoporous Platinum Electrodes for CMOS Integrated Enzymeless Glucose Sensor Applications (CMOS 집적회로 기반의 무효소 혈당센서 적용을 위한 메조포러스 백금 전극 제작 및 최적화)

  • Seo, Hye-K.;Park, Dae-J.;Park, Jae-Y.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1627-1628
    • /
    • 2006
  • In this paper, mesoporous only platinum electrode and micro pore platinum electrode with mesoporous Pt are fabricated and characterized on a silicon substrate to check their usability as enzymeless sensing electrodes for developing non-disposable glucose sensors integrated with silicon CMOS read out circuitry. Since most of electrochemical glucose sensors are disposable due to the use of the enzymes that are living creatures, these are limited to use in the in-vivo and continuous monitoring system applications. The proposed mesoporous Pt electrode with approximately 2.5nm in pore diameter and 150nm in height was fabricated by using a nonionic surfactant $C_{16}EO_8$ and an electroplating technique. The micro pore Pt electrode with mesoporous Pt means the mesoporous Pt electrode fabricated on top of micro pore arrayed Pt electrode with approximately $10{\mu}m$ in pore diameter and $80{\mu}m$ in height. The measured current responses at 10mM glucose solution of plane Pt, micro pore Pt, micro pore with mesoporus Pt, and mesoporous Pt electrodes are approximately $9.9nA/mm^2$, $92.4nA/mm^2$, $3320nA/mm^2$ and $44620nA/mm^2$, respectively. These data indicate that the mesoporous Pt electrode is much more sensitive than the other Pt electrodes. Thus, it is promising for non-disposable glucose sensor and electrochemical sensor applications.

  • PDF