• Title/Summary/Keyword: application program protection

Search Result 105, Processing Time 0.025 seconds

Intellectual Property Rights Analysis of 3D Avatars for Ubiquitous Fashion Business (유비쿼터스 패션 비즈니스를 위한 3차원 Avatar의 지적재산권 분석)

  • Park, Ha-Jin;Chang, Sue-Hyun;Park, Chang-Kyu
    • Journal of Fashion Business
    • /
    • v.13 no.4
    • /
    • pp.37-50
    • /
    • 2009
  • Recently, as individual 3D avatars are rapidly generalized in internet sites, its commercial applications for fashion business are being tried in ubiquitous fashion shopping era. In this research, we have investigated and analyzed patent problems of 3D avatar including personal body data to activate the fashion business using 3D avatars. Here, considering the patents for 3D face and body generation methods are already published, this research is focused on whole 3D body avatar obtained from individual body information. Firstly, definition of 3D avatar and its application cases have been investigated and then it has been researched whether or not legal protections by patent law, copyright law, computer program protection law, design protection law and fair competition laws are feasible in view of the subjects to be protected in each law and requirements for such protections. It was revealed that patent law may provide legal protections for 3D avatar and domestic and foreign patents related to 3D avatar have been researched.

Effect of a restaurant hygienic grade certificate program on consumer choices

  • Kim, Jae-il;Choi, Jinkyung
    • Nutrition Research and Practice
    • /
    • v.15 no.sup1
    • /
    • pp.70-78
    • /
    • 2021
  • BACKGROUND/OBJECTIVES: The recent coronavirus disease 2019 pandemic has brought to light issues regarding personal and environmental cleanliness. Individuals may have concerns about cleanliness at food service establishments when they consume food prepared at a restaurant. In Korea, a new restaurant hygienic certificate system was implemented in 2017. The effect of this new system has not been evaluated. SUBJECTS/METHODS: This study investigated consumers' perceptions of these new certificates using the protection motivation theory (PMT). An online survey was conducted to collect data and then exploratory factor analysis, analysis of variance, and multiple regression tests were run. RESULTS: The results of this study indicate that 3 different certificates had significant differences in threat (P < 0.001) and benefit (P < 0.001) perception. However, experience with a foodborne illness from a restaurant did not effect on the PMT variables. In addition, the 3-tier certificate did not motivate consumers to protect themselves against foodborne illnesses, while previous experiences of foodborne illness (P < 0.05), coping (P < 0.001), and benefits (P < 0.01) affected this protection motivation. CONCLUSIONS: This study suggests that consumers were not influenced by different certificate levels regarding their motivation to protect themselves from foodborne illnesses. Therefore, an improved plan should be initiated to clarify the meaning of these certificates. The results of this study can help the application and development of a new system for future adaptations.

A Study of Comparative Evaluation for High-rise Building Fire Risk by the Use of FREM (FREM을 적용한 고층건물의 화재위험도 비교평가연구)

  • 김동일;손기상;이수경
    • Fire Science and Engineering
    • /
    • v.16 no.1
    • /
    • pp.45-50
    • /
    • 2002
  • This study set its bases needed for building fire risk analysis by examining general concept and definitions of fire risk analysis, and its access methods. Upon this basis, by using a computer program FREM, we brought the type of hazards out of the fire risk assessment applied to the typical 100 high-rise buildings in and out of this country. In this process, we also sorted out the programs arising from the application of a foreign born tool to domestic conditions. the credibility of fire separations and automatic fire protection system in a building would be the two most important things in an attempt to evaluate fire risk in high-rise buildings. In addition, it is vital for the purpose of securing fire safety in high-rise buildings that the systems should be properly installed and carefully maintained. When we try hard to study the evaluation standards to the above systems and, someday in the future, to employ them in evaluating fire risks in high-rise buildings, we can measure the risks much more precisely with less expenses than that we needed today.

VMProtect Operation Principle Analysis and Automatic Deobfuscation Implementation (VMProtect 동작원리 분석 및 자동 역난독화 구현)

  • Bang, Cheol-ho;Suk, Jae Hyuk;Lee, Sang-jin
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.30 no.4
    • /
    • pp.605-616
    • /
    • 2020
  • Obfuscation technology delays the analysis of a program by modifying internal logic such as data structure and control flow while maintaining the program's functionality. However, the application of such obfuscation technology to malicious code frequently occurs to reduce the detection rate of malware in antivirus software. The obfuscation technology applied to protect software intellectual property is applied to the malicious code in reverse, which not only lowers the detection rate of the malicious code but also makes it difficult to analyze and thus makes it difficult to identify the functionality of the malicious code. The study of reverse obfuscation techniques that can be closely restored should also continue. This paper analyzes the characteristics of obfuscated code with the option of Pack the Output File and Import Protection among detailed obfuscation technologies provided by VMProtect 3.4.0, a popular tool among commercial obfuscation tools. We present a de-obfuscation algorithm.

Development and Application of Pre/Post-processor to EMTP for Sequence Impedance Analysis of Underground Transmission Cables (지중 송전선로 대칭분 임피던스 해석을 위한 EMTP 전후처리기 개발과 활용)

  • Choi, Jong-Kee;Jang, Byung-Tae;An, Yong-Ho;Choi, Sang-Kyu;Lee, Myoung-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.10
    • /
    • pp.1364-1370
    • /
    • 2014
  • Power system fault analysis has been based on symmetrical component method, which describes power system elements by positive, negative and zero sequence impedance. Obtaining accurate line impedances as possible are very important for estimating fault current magnitude and setting distance relay accurately. Especially, accurate calculation of zero sequence impedance is important because most of transmission line faults are line-to-ground faults, not balanced three-phase fault. Since KEPCO has started measuring of transmission line impedance at 2005, it has been revealed that the measured and calculated line impedances are well agreed within reasonable accuracy. In case of underground transmission lines, however, large discrepancies in zero sequence impedance were observed occasionally. Since zero sequence impedance is an important input data for distance relay to locate faulted point correctly, it is urgently required to analyze, detect and consider countermeasures to the source of these discrepancies. In this paper, development of pre/post processor to ATP (Alternative Transient Program) version of EMTP (Electro-Magnetic Transient Program) for sequence impedance calculation was described. With the developed processor ATP-cable, effects of ground resistance and ECC (Earth Continuity Conductor) on sequence impedance were analyzed.

Development and evaluation of a model for management of plant pests in organic cucumber cultivation

  • Ko, S.J.;Kang, B.R.;Kim, D.I.;Choi, D.S.;Kim, S.G.;Kim, H.K.;Kim, H.J.;Choi, K.J.;Kim, Y.C.
    • Korean Journal of Organic Agriculture
    • /
    • v.19 no.spc
    • /
    • pp.263-266
    • /
    • 2011
  • Crop protection strategies in organic horticulture aim to prevent insect pest and plant disease problems through utilization of non-chemical based control means. In order to develop a model for management of plant diseases and insects in organic cucumber cultivation, we compared efficacies between chemical pesticide spraying system and biological control means in semi-forcing and retarding cucumber cultivation during 2005 and 2006. Conventional chemical spray program using various chemical pesticides was applied 5 - 10 days intervals, while two different non-chemical pesticide application programs using two formulated biopesticides Topseed$^{TM}$ and Q-fect$^{TM}$, Suncho$^{TM}$, and Sangsungje$^{TM}$ (biocontrol agents 1) and using egg-yolk and cooking oil(EYCO), Bordeaux mixture, Suncho$^{TM}$, and Sangsungje$^{TM}$ (biocontrol agents 2) were applied 5 - 7 days intervals during entire cucumber cultivation period. Efficacy of both biocontrol agents programs was effective to comparable to conventional chemical pesitice spray program to control plant diseases such as powdery mildew and downy mildew as well as insect pests such as aphids and thrips which are known as major threats in cucumber organic cultivation. In this study, we established and evaluated an effective and economic crop protection strategy using various biological resources can be used to control plant diseases and pests simultaneously in organic cucumber cultivation field.

Development and Evaluation of the Utility of a Respiratory Monitoring and Visual Feedback System for Radiotherapy Using Machine Vision Technology

  • Kim, Chul Hang;Choi, Hoon Sik;Kang, Ki Mun;Jeong, Bae Kwon;Jeong, Hojin;Ha, In Bong;Song, Jin Ho
    • Journal of Radiation Protection and Research
    • /
    • v.47 no.1
    • /
    • pp.8-15
    • /
    • 2022
  • Background: We developed a machine vision technology program that tracks patients' real-time breathing and automatically analyzes their breathing patterns. Materials and Methods: To evaluate its potential for clinical application, the image tracking performance and accuracy of the program were analyzed using a respiratory motion phantom. Changes in the stability and regularity of breathing were observed in healthy adult volunteers according to whether the breathing pattern mirrored the breathing guidance. Results and Discussion: Displacement within a few millimeters was observed in real-time with a clear resolution, and the image tracking ability was excellent. This result was consistent even in the sections where breathing patterns changed rapidly. In addition, the respiratory gating method that reflected the individual breathing patterns improved breathing stability and regularity in all volunteers. Conclusion: The findings of this study suggest that this technology can be used to set the appropriate window and the range of internal target volume by reflecting the patient's breathing pattern during radiotherapy planning. However, further studies in clinical populations are required to validate this technology.

The French Underground Research Laboratory in Bure: An Essential Tool for the Development and Preparation of the French Deep Geological Disposal Facility Cigéo

  • Pascal Claude LEVERD
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.21 no.4
    • /
    • pp.489-502
    • /
    • 2023
  • This article presents the crucial role played by the French underground research laboratory (URL) in initiating the deep geological repository project Cigéo. In January 2023, Andra finalized the license application for the initial construction of Cigéo. Depending on Government's decision, the construction of Cigéo may be authorized around 2027. Cigéo is the result of a National program, launched in 1991, aiming to safely manage high-level and intermediate level long-lived radioactive wastes. This National program is based on four principles: 1) excellent science and technical knowledge, 2) safety and security as primary goals for waste management, 3) high requirements for environment protection, 4) transparent and open-public exchanges preceding the democratic decisions and orientations by the Parliament. The research and development (R&D) activities carried out in the URL supported the design and the safety demonstration of the Cigéo project. Moreover, running the URL has provided an opportunity to gain practical experience with regard to the security of underground operations, assessment of environmental impacts, and involvement of the public in the preparation of decisions. The practices implemented have helped gradually build confidence in the Cigéo project.

A Study of Verification on Application of Directional OCR and OCGR for Power System with Small Scale Cogeneration (소형 열병합 발전소의 계통연계시 방향성 과전류 및 지락과전류 계전기의 적용 검증 연구)

  • Lee, Hee-Tae;Cho, Man-Young;Kim, Jae-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.6
    • /
    • pp.944-950
    • /
    • 2008
  • When small cogenerators are operated in connected with power system, there are many positive aspects such as the reduction of power plant construction, making a improvement of power security etc. At the same time, there are some negative effects or difficulties such as we should make sure of protective coordination, especially, Actually these are not fault, but it is likely to consider the current as the fault. This is one of major causes of malfunctions for protective relays in power distribution system which is including interconnection point. Thus, in this paper, We showed that the directional protection is necessary to the dispersed generation system which is including connection point. We also executed contingency analysis to find out the magnitude of fault current and direction which are classified by fault points, length of line and kinds of faults using ETAP power system analysis program.

Travelling Wave Technique for Close-Up Fault Protection (진행파를 이용한 근접사고 거리계전 방식)

  • Kim, Gon-Wook;Kang, Sang-Hee;Park, Jong-Keun;Kim, Il-Dong;Yun, Man-Cheol;Kwon, Wook-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1990.11a
    • /
    • pp.202-205
    • /
    • 1990
  • In this paper the development of new technique based on the travelling-wave information contained in the post fault voltage and current signals has been presented. To develop fault location methods which can cope with close-up fault and zero-inception angle problems, magnitude of the backward wave has been used. The technique developed can be incorporated in a generalized algorithm for application as a high speed distance scheme. In this way some of the problems and limitations associated with travelling wave schemes are avoided. Verification of the relay operating principles is presented through digital computer numerical simulation using an electromagnetic transient program(EMTP) in conjunction with simulation of the proposed algorithms.

  • PDF