• Title/Summary/Keyword: appearance test

Search Result 1,094, Processing Time 0.025 seconds

Micronucleus Test of Bupleuri Radix Aqueous Extract in Bone Marrow Cells of Male ICR Mice (시호 물 추출물의 마우스 골수세포를 이용한 유전독성 평가)

  • Cheon, Woo-Hyun;Chung, In-Kwon;Kang, Su-Jin;Ku, Sae-Kwang;Lee, Young-Joon
    • Korean Journal of Oriental Medicine
    • /
    • v.18 no.2
    • /
    • pp.151-157
    • /
    • 2012
  • In this research, the genotoxic effect of Bupleuri Radix (BR), the dried roots of Bupleurum falcatum Linne has been traditionally used as anti-inflammatory agent, was evaluated using the mouse micronucleus test. BR aqueous extract (yield = 16.52%) was administered once a day for 2 continuous days by oral gavage to male ICR mice at doses of 2,000, 1,000 and 500 mg/kg. Cyclophosphamide (CPA) 70 mg/kg was used as a known genotoxic agent in a positive control. The appearance of a micronucleus (MN) in polychromatic erythrocyte (PCE) is used as an index for genotoxic potential, and PCE ratio is used as an index of cytotoxicity. Although significant (p<0.01) increase of the number of PCE with one or more nuclei (MNPCE) was detected in CPA treated groups, no significant increases of MNPCE numbers were observed in all three different dosages of BR extracts treated mice with over 0.30 of the individual polychromatic erythrocyte ratio in all mice used in this study. The results obtained indicated that BR extract shows no genotoxicity effects up to 2,000 mg/kg dosing levels the limit dosage in rodents.

Micronucleus Test of $Scutellariae$ $Radix$ Aqueous Extract in Bone Marrow Cells of Male ICR Mice (황금(黃芩) 물 추출물의 마우스 골수세포를 이용한 유전독성 평가)

  • Chung, In-Kwon;Cheon, Woo-Hyun;Kang, Su-Jin;Ku, Sae-Kwang;Lee, Young-Joon
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.16 no.1
    • /
    • pp.81-89
    • /
    • 2012
  • Objectives : In this research, the genotoxic effect of $Scutellariae$ $Radix$(SR), the dried roots of $Scutellaria$ $baicalensis$ Georgi has been traditionally used as antipyretic agent, was evaluated using the mouse micronucleus test. Methods : SR aqueous extract(yield = 27.2%) was administered once a day for 2 continuous days by oral gavage to male ICR mice at doses of 2,000, 1,000 and 500 mg/kg. Cyclophosphamide(CPA) 70 mg/kg was used as a known genotoxic agent in a positive control. The appearance of a micronucleus(MN) in polychromatic erythrocyte(PCE) is used as an index for genotoxic potential, and PCE ratio is used as an index of cytotoxicity. Results and Conclusions : Although significant(p<0.01) increase of the number of PCE with one or more nuclei(MNPCE) was detected in CPA treated groups, no significant increases of MNPCE numbers were observed in all three different dosages of SR extracts treated mice with over 0.33 of the individual polychromatic erythrocyte ratio in all mice used in this study. The results obtained indicated that SR extract shows no genotoxicity effects up to 2,000 mg/kg dosing levels - the limit dosage in rodents.

Survey of Research Papers on the Sensory Evaluation of Kimchi (관능검사에 의한 김치의 품질평가방법에 관한 실태조사: $1970{\sim}1995$년 학회지 게재논문 분석)

  • Hwang, In-Sook;Kim, Young-Nam
    • Korean Journal of Human Ecology
    • /
    • v.8 no.2
    • /
    • pp.355-362
    • /
    • 1999
  • The purpose of this study is focused on the quality of Kimchi by sensory evaluation in 67 research papers published by 8 kinds of food & nutrition related Korean journals from $1970{\sim}1995$. The results are summarized as follows : 1) Among 126 research papers on Kimchi, sensory evaluation results were shown in 67 papers. 2) The numbers of panelists for sensory evaluation were $10{\sim}12$ in 32 papers, $7{\sim}9$ in 15 papers, and $4{\sim}6$ in 6 papers. 3) The method of sensory evaluation applied was scoring test in all 67 papers. Among them, 25 papers utilized 5-points scale, 16 papers 9-points scale, and 11 papers 7-points scale evaluation. 4) Evaluated sensory characteristics were taste, texture, odor, appearance & color, and others. Sourness, salty, and carbonic taste in taste; hardness, crispness, and toughness in texture; moldy, acidic, and grassy odor in odor were the most frequently tested characteristics. 5) Fermentation/storage periods, fermentation/storage temperature, and concentration of salt/time of soaking in salt solution were the most frequently tested variables. 6) To evaluate the statistical difference, 31 papers applied F-test, and 9 papers were applied Duncan's multiple range test to determine which samples are significantly different from others. In 6 papers, correlation coefficients were calculated between sensory evaluation scores and the results of mechanical determinations.

  • PDF

A sham moxibustion device and Masking test (가짜뜸 개발 및 Masking test)

  • Park, Ji-Eun;Han, Chang-Hyun;Kang, Kyung-Won;Shin, Mi-Suk;Oh, Dal-Seok;Choi, Sun-Mi
    • Korean Journal of Oriental Medicine
    • /
    • v.13 no.1 s.19
    • /
    • pp.93-100
    • /
    • 2007
  • TObjectives: Develop a sham moxibustion and determine whether subjects can distinguish a sham moxibustion from a real moxibustion. Design: Single-blinded, randomized, placebo-controlled clinical trial Methods: Sham and real moxibustion resemble each other in appearance, burning procedure, but the base of the sham moxibustion isolates the moxa-producing heat and smoke. This device was tested in a clinical trial in which subjects received moxibustion at Zhongwan(CV12), Mingmen(GV4), Quchi(LI11), Zusanli(ST36), Taichong(LR3)), Hegu(LI4). Volunteers(n=32) were given pre-treatment questionnaire to assess their experience in getting moxibustion therapy and performing it. They randomized into treatment(n=16) or sham controlled group(n=16), received moxibustion according their groups. After treatments, the effectiveness of blinding was assessed. Results: There were no significant differences between two groups in sex, age, moxibustion experience. In the treatment group and the sham group, the number of subjects who believed they received real moxibustion or sham is not different significantly.(P=.668) The consistency of a moxibustion type which subjects received actually and the their guess about that, isn't different significantly in two groups.(P=.465) Conclusion: The sham moxibustion was successfully validated in this study, The results demonstrate that this sham moxibustion blinds subjects and can be used as effective placebo-control in moxibustion clinical trials.

  • PDF

Quality Characteristics of Sprout Ginseng Paste added Dry Oyster and Dry Shrimp (굴과 새우를 이용한 새싹삼 페이스트의 품질특성)

  • Jung, Hee-Bum;Seoung, Tae-Jong;Kim, Jeong-Gyun
    • Culinary science and hospitality research
    • /
    • v.23 no.8
    • /
    • pp.206-215
    • /
    • 2017
  • Sprout ginseng paste were prepared with pine nut, dry oyster and dry shrimp to examine the antioxidant properties(total polyphenols, total flavonoids, and electron donating ability) and sensory test(attribute difference and acceptance). Sprout ginseng paste were measured based on color value, pH, viscosity, total bacteria cell numbers for 0 and 20 days at $4^{\circ}C$. The higher total polyphenol and total flavonoid content of sprout ginseng paste added with pine nuts, dry oyster, and dry shrimp were higher antioxidant capacity. DPPH radical scavenging activity was increased from 52.2% (SGP0) to 79.5.0 % with SGP5. The attribute test results reveal that the color intensity, bitter taste, and oily taste were decreased in SGP3 to SGP6. Taste, flavor, and coarseness did not show significant difference in SGP0 to SGP6. Thickness and After taste were increased in SGP4 to SGP6. The preference test results reveal that the appearance, flavor, and texture level did not show significant difference in SGP0 to SGP6. Taste and overall preference were increased in SGP4 to SGP6. L value, pH, decrease while a value and b value show no change in sprout ginseng paste with pine nut, dry oyster and dry shrimp. Total cell number was not detected during storage.

The effects of autogenous composite grafts on bone regeneration after sinus elevation (상악동거상술시 자가골 복합이식이 골재생에 미치는 영향)

  • Nah, Eui-Seong;Kwon, Young-Hyuk;Park, Joon-Bong;Herr, Yeek
    • Journal of Periodontal and Implant Science
    • /
    • v.34 no.2
    • /
    • pp.377-392
    • /
    • 2004
  • The purpose of this present study was to investigate the effect of autogenous bone with histological evaluation of regenerated bone after sinus elevation. The study involved genaral healthy 6 patients participated in this study and were treated with 2-stage sinus elevation procedures using a combination of demineralized freezed-dried bone allograft (DFDBA) and coralline calcium carbonate with or without autogenous bone. At 6months after sinus elevation, bone specimens were obtained and stained with Hematoxylin-Eosin for light microscopic evaluation. The results of this study were as follows : 1. Autogenous bone grafts present trabecular patterns at 6 months in test groups, consist of woven bone and lamellar bone, but more compact than control groups. 2. Resorption of bone graft particles, osteoblast-like cells, newly formed osteoid tissue were observed at 6 months in test groups, but seems to be more frequently than control groups. 3. New osteoid tissue was formed from the surface of graft materials and gradually expanded around them. 4. The appearance of connective tissue around graft materials was densely formed, but more prominent in test groups than control groups. 5. Bone graft particles were resorbed incompletely and slight inflammatory infiltrate, newly formed capillaries, and adipocytes were observed. From the above results, autogenous bone is effective in bone regeneration after sinus elevation, could provide favorable conditions in implant placement.

Evaluation of Flexural Strength of Silicon Die with Thickness by 4 Point Bending Test (4점굽힘시험에 의한 실리콘 다이의 두께에 따른 파단강도 평가)

  • Min, Yoon-Ki;Byeon, Jai-Won
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.18 no.1
    • /
    • pp.15-21
    • /
    • 2011
  • In this study, flexural strength and fracture behavior of silicon die from single crystalline silicon wafer were investigated as a function of thickness. Silicon wafers with various thickness of 300, 200, 180, 160, 150, and 100 ${\mu}m$ were prepared by mechanical grinding and polishing of as-saw wafers. Flexural strength of 40 silicon dies (size: 62.5 mm${\times}$4 mm) from each wafer was measured by four point bending test, respectively. For statistical analysis of flexural strength, shape factor(i.e., Weibull modulus) and scale factor were determined from Weibull plot. Flexural strength reflecting both statistical fracture probability and size (thickness) effect of brittle silicon die was obtained as a linear function of die thickness. Fracture appearance was discussed in relation with measured fracture strength.

A Case of Hemolytic Disease of a Newborn by an Anti-$Di^a$ Antibody Treated with Intravenous Immunoglobulin (정맥용 면역글로불린 투여로 호전된 항-$Di^a$ 항체에 의한 신생아 용혈성 질환 1예)

  • Lee, Chang Eon;Park, Su Jin;Kim, Won Duck
    • Journal of Yeungnam Medical Science
    • /
    • v.30 no.1
    • /
    • pp.21-24
    • /
    • 2013
  • Hemolytic disease in a newborn that causes early jaundice is common. It is often due to the Rh (D) and ABO incompatibility, but rarely due to unexpected antibodies. Among these unexpected antibodies, the anti-$Di^a$Dia antibody rarely occurs. The anti-$Di^a$ antibody was observed in the serum and red-cell eluate of an infant, and in the serum of his mother. The frequency of the appearance of the $Di^a$ antigen in the Korean population is estimated to be 6.4-14.5%. This paper reports a case of hemolytic disease in a newborn associated with the anti-$Di^a$ antibody. A full-term male infant was transferred to the authors' hospital due to hyperbilirubinemia the day after his birth. The laboratory data indicated a hemoglobin value of 11.6 g/dL, a reticulocyte count of 10.6%, a total bilirubin count of 14.4 mg/dL, a direct bilirubin count of 0.6 mg/dL, and a positive result in the direct Coombs' test. Due to the identification of an irregular antibody from the maternal serum, an anti-$Di^a$ antibody was detected, which was also found in the eluate made from the infant's blood. The infant had been treated with phototherapy and intravenous immunoglobulin since the second day after his birth and was discharged due to an improved condition without exchange transfusion. Therefore, in cases of iso-immune hemolytic disease in a newborn within 24 hours from birth who had a negative result in an antibody screening test, the conduct of an anti-$Di^a$ antibody identification test is recommended due to the suspicion of an anti-$Di^a$ antigen, followed by early administration of intravenous immunoglobulin.

A STUDY ON THE SURFACE ROUGHNESS AND REFLECTIVITY AFTER POLISHING OF THE MICROFILL, HYBRID COMPOSITE RESINS (Microfill, Hybrid 복합레진 연마 후 표면조도와 광반사율에 관한 연구)

  • Moon, Anne-Jay;Kwon, Hyuk-Choon
    • Restorative Dentistry and Endodontics
    • /
    • v.19 no.2
    • /
    • pp.513-533
    • /
    • 1994
  • The smooth surface after polishing of composite resin contributes to the patient's comfort, and appearance and longevity of the restoration. This study was performed for the quantitative analysis of the effects of the various finishing and polishing instruments on the surface roughness and reflectivity of the microfill, and hybrid composite resins. Cylindrical specimens 2mm thick and 10mm in diameter of Silux Plus, Durafill VS ; Z100, Prisma TPH, Brilliant, and Herculite XR composite resin were polymerized under the matrix strip. 18 specimens for each composite resin materials were divided into 6 groups ; 5 experimental groups were abraded with # 600 sand paper to remove resin-rich layer, except control. Thereafter, using diamond bur(Mani Dia-Burs), carbide bur(E. T. carbide set 4159), rubber point(Composite polishing kit), aluminum-oxide disk(Sof-Lex disk), polishing paste(Enhance system) ; each specimen was polished to its best achievable surface according to manufacturer's directions. Final polished surfaces were evaluated for the surface roughness with profilometer(${\alpha}$-step 200, Tencor instruments, USA) and for the reflectivity with image analyser(Omniment Image Analyser, Buehler, USA). The results were as follows. 1. Polishing paste or aluminum-oxide disk finish in the microfill, and hybrid composite resins was as smooth as matrix strip finish on the surface roughness test. 2. Polishing paste or aluminum-oxide disk finish in the microfill ; polishing paste finish in the hybrid composite resins was as reflective as matrix strip finish on the refectivity test. 3. For the polishing paste, there were no significant differences between the composite resin materials on the surface roughness and refectivity tests. 4. For the aluminum-oxide disk, the best result was obtained with the microfill composite resin on the surface roughness and reflectivity test. 5. Diamond bur, carbide bur, and rubber point were inappropriate for the final polishing instruments.

  • PDF

A Study on the Wear Characteristics of Compound Layers Formed during Gaseous Nitrocarburizing in Medium Carbon Boron Steels (중탄소 Boron강의 가스침질탄화처리에 의해 형성된 화합물층의 마모특성에 관한 연구)

  • Park, K.W.;Oh, D.W.;Cho, H.S.;Lee, H.W.;Lee, J.B.;Lee, S.Y.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.12 no.2
    • /
    • pp.136-144
    • /
    • 1999
  • The study on the wear characteristics of compound layers formed during gaseous nitrocarburising in the medium carbon boron steels and the plain carbon steel has been carried out by using a pin-on-disc type wear test machine under the oil lubricating condition at room temperature and by varying applied loads, sliding speeds and wear distances. Values of friction coefficient measured at the sliding speed of 0.4m/sec under the oil lubricating condition have been shown to decrease considerably with increasing applied load and become gradually a constant value as load is increased to a higher value, showing that the transition load for friction coefficient appears at an applied load of 247.2N. The length and volume wear rates of compound layer have been revealed to relatively constantly increase, also showing that the wear life per unit thickness of compound layer turns out to be superior as porous layer has a denser and thinner appearance. As the sliding speed increases during wear test performed by varying sliding speed at a load of 63.2N under the oil lubricating condition for medium carbon boron steel nitrocarburised in gas atmosphere, the wear rate has been found to increase, the friction coefficient to decrease and the wear life per unit thickness of compound layer to decrease considerably.

  • PDF