Optimal Supply Scheme of Solar Hot Water Heating Systems for the Apartment Complexes (공동주택용 태양열 급탕시스템 최적공급 방안 해석연구)

  • Lee, Chul-Sung;Park, Ja-Son;Park, Jae-Wan;Shin, U-Cheul;Yoon, Jong-Ho
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.245-250
    • /
    • 2008
  • This study is on the availability of solar thermal energy in Korean high-rise apartment complex depending on the installation type of solar collectors to roof or facade of building. Firstly, solar access evaluation on the roof and the facade of apartment buildings was carried out. The total thermal load of each apartment unit and building was investigated and matched with the energy which was produced by solar thermal systems on the facade. The considered layout patterns of apartment buildings were '一type', 'alternative 一type', 'ㄱtype' and 'ㅁtype' and that was analyzed in prior studies. Extensive dynamic hourly energy simulations with the solar thermal system were Performed with the TRNSYS of SEL. We assumed that the apartment complex is composed of 9 buildings and located in Daejeon. The collectors are the heat-pip evacuated tube collectors and the number of collectors are 45 tubes We assumed that the collectors are installed on the balcony of each unit and the angle of incilnation is $90^{\circ}$. As a result, the supply amount of solar thermal systems is about 4,850,086kJ/hr and the solar fraction is about 66%. The solar fraction according to each azimuth is about 66% on the south, 62% on the south-east $30^{\circ}$ and 56% on the south-east $60^{\circ}$. So, we quantitatively got a line on the optimal azimuth for installing the solar thermal systems. The solar fraction has differences from 5% to 15% of each floor, 6th, 12th and 20th and those tendencies are same in analyzed each 4 types of the apartment complexes.

  • PDF

Study on Application of Shaft Box type Balcony for Improvement of Ventilation Performance in Apartment (공동주택의 환기성능 개선을 위한 Shaft Box형 발코니의 적용성 검토)

  • Roh, Ji-Woong;Kim, Gon
    • KIEAE Journal
    • /
    • v.7 no.6
    • /
    • pp.3-8
    • /
    • 2007
  • Recently, because of the continuous rise of international oil price, energy saving is strongly demanding. So, Ecological technics of architecture such as use of natural energy have been actively explored in the field of building. In the method of utilizing natural energy, the key point is to saving energy effectively as not lowering the comfort of indoor environment, various systems investigated. Many papers about double skin facade system have been reported, it is announced broadly that the system is very effective in improvement of natural ventilation and indoor thermal environment, and also protecting outdoor sound. The shaft box facade is a special form of box window construction. It consists of a system of box windows with continuous vertical shafts that extend over a number of stories to create a stack effect. The facade layout consists of an alternation of box windows and vertical shaft segments. This research investigated the natural ventilation performance of shaft box type balcony which conform the shaft box type double skin to the exiting balcony construction. First, analyzed various types of exiting apartments, proto-type was decided. By using virtual environment Program, modeling the proto-type, compared the contribution of air temperature and the effect of outdoor air cooling. by this research, we confirmed that shaft box type balcony had many possibility for improvement of indoor environment.

Study on the efficient noise prediction for an apartment house (공동주택 소음예측 방법에 관한 연구)

  • Ko, J.H.;Kim, D.J.;Park, S.J.;Chang, S.I.;Cho, M.H.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.505-509
    • /
    • 2008
  • This paper studied the efficient noise prediction method for new apartment house near the road traffic noise. Three noise prediction software were compared by each prediction noise level using the simple model which is included the road, soundproofing wall and building. Two foreign national calculation models(RLS-90 and NMPB) were verified by comparison of measured sound level. Frequency of sound level was predicted by NMPB and compared by measured data. The sphere of noise source and facade reflection were proposed to accurate predict the road traffic noise in new apartment house.

  • PDF

A Study on Application of Shaft-box Type Double Skin to Apartment Building (공동주택에 대한 Shaft Box형 이중외피의 적용에 관한 연구)

  • Roh, Ji Wooung
    • KIEAE Journal
    • /
    • v.13 no.1
    • /
    • pp.75-81
    • /
    • 2013
  • The balcony of our apartment building consists of unique construction similar to double skin. It is announced broadly that double skin is very effective system in improvement of natural ventilation and indoor thermal environment, and outdoor sound protection. So, for the improvement of indoor climate and energy saving, many peoples studied about environmental performance of our balcony construction. This study focus on shaft box facade, special form of box window construction. It consists of a system of box window with continuous vertical shafts that extend over a number of stories to create a stack effect. Proto-type was decided by analyzing various types of exiting apartments. Shaft box type balcony was created by setting up shaft space at a part of balcony. Air flow and contribution of air temperature were simulated, performance of shaft box type balcony was compared with existing balcony. Finally, we confirmed that shaft box type balcony has many possibility for improvement of indoor environment.

Effects of the Facade of the Buildings on the Sound Characteristics in an Apartment Complex (공동주택 입면 변화에 따른 단지 내 소음특성)

  • Kim, Yong-Hee;Lee, Pyoung-Jik;Jeon, Jin-Yong;Lee, Byung-Kwon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.367-370
    • /
    • 2005
  • This paper investigated the sound characteristics in an apartment complex. The field measurement was conducted in order to examine the acoustical characteristics of the apartment complex in situ. As a result, it shows that there are around 3 sec. reverberation time and the additional sound reinforcements at the area of high height due to the surrounded buildings. Thus, 1:50 Scale model measurement and Raynoise computer simulation were carried out with insertion of the parapet and the canopy on the balcony. In case of a single building, the parapet was effective to reduce noise level at low floor levels, and the canopy was effective to reduce noise level at high floor levels. But it also shows that both the parapet and the canopy were not effective to reduce noise level at middle floor levels. In case of an apartment complex, the canopy was less effective to reduce noise level at each floor in comparison with case of the single building.

  • PDF

A Study on the Design Types and Characteristics of Apartment Entrances - Focus on Whasung Dongtan Apartments - (아파트 동출입구 디자인 유형 및 특성에 관한 연구 - 화성동탄신도시 시범지구 및 1, 2공구 아파트를 중심으로 -)

  • Lee, Ki-Seok
    • Korean Institute of Interior Design Journal
    • /
    • v.18 no.6
    • /
    • pp.184-193
    • /
    • 2009
  • In recent years, the architectural interest in the apartment design has been getting focused on qualitative improvement and design differentiation. Especially the facade design differentiation is one of the most important elements in this matter. The purpose of this study is to provide the basic informations that can be referenced when architects are dealing with exterior design by analyzed design types and characteristics of apartment entrances. Target apartment of this study was whasung dongtan the 2nd phase new city districts which was planned to solve a housing shortage in the capital region. Having examined eleven pilot districts, four 1st construction areas, and eight 2nd construction areas, - total 23 complexes - 282 apartment entrances in 212 apartment buildings were carefully researched. Apartment entrance design can be divided into 15 different design elements: design types and combination types, direction, shape, height, approach types, exterior wall finishes of entrance, exterior wall finishes of lower parts of apartment, handrail types of slope, floor finishes of slope, distribution ratio of piloti, ceiling height of piloti, floor finishes of piloti, space use of piloti, window establishment between piloti and elevator hall, landscape elements of piloti. Design characteristics of building entrances were also analyzed in 4 groups (I, II, III, IV) divided by construction contractors ranking. In conclusion, first, design types and combination types can be classified into 15 different kinds, and the group I and II tend to show wider variety of entrance combinations. Secondly, the height and volume of extrude entrance type tend to increase in the group I and II. Third, the spatial configuration of pilotis appears to show more of 'pass + store + break' rather than 'access', as we get closer to the group I.

Indoor Airflow of High-Rise Apartment with Different Types of Box-Windows (초고층 공동주택의 이중외피 창호 유형별 실내기류 특성 비교)

  • Choi, Tae-Hwoan;Jeon, Mi-Sook;Lee, Jung-Hyun;Kim, Tae-Yeon;Leigh, Seung-Bok
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.993-998
    • /
    • 2006
  • High-rise apartments have a problem using natural ventilation because of the strong outdoor wind velocity. Conventional high-rise apartments have adopted mechanical ventilation systems to maintain the indoor air quality. However, it leads to the overuse of electricity and the sick house syndrome. Double-skin facade is the alternative for the high-rise building to use natural ventilation and this study is focused on the performance of the box-window, which is a kind of double-skin facades. Indoor wind velocity and HCHO concentrations are analyzed with three types of box-windows: the diagonal type, parallel type and perpendicular type. The airflow is simulated by computational fluid dynamics program. Box-windows reduce the maximum value of indoor wind velocity about 50% compared with the single window and the HCHO concentrations do not have the big difference. Box-windows could be the alternative to enhance the use of the natural ventilation and indoor air quality of the high-rise apartment.

  • PDF

Sensibility Evaluation of Components of Middle and High-rise Apartment Facade in Aesthetic Old Town Districts of Kyoto - Extraction of Component Combinations Using Rough Set Theory - (쿄토시 구시가지형미관지구에서 중고층 집합주택 입면의 구성요소에 대한 감성평가 - 러프 집합을 이용한 구성요소 조합의 추출 -)

  • Shon, Dong-Hwa
    • Journal of the Korean housing association
    • /
    • v.25 no.3
    • /
    • pp.105-114
    • /
    • 2014
  • Landscape zones have been designated as aesthetic old town districts across a wide range of Nakakyo-Ku and Shimokyo-Ku, city center of Kyoto, Japan. In these districts in which traditional structures and new buildings coexist, regulations of restriction on acts such as new building's heights, shapes, materials, and colors are carried out according to local governmental landscape ordinance based on Scenic Conservation Act. And yet, minimal fulfillment of the regulations according to different designer's subjective interpretation and principle of economy is rather creating abnormal shapes not harmonized with the traditional landscape. Thus, this study aims to extract combinations between form elements of middle and high rise apartment facade that affects 'harmony' and 'mismatch' in the districts by clarifying the social rules commonly implied based on intuitive judgments (sensibility evaluation) in which human experiential knowledge is involved. As research methods, the study first analyzes the form elements of the facade through a field survey, sets up a standard model through tasks of classification and segmentation and draws computer graphic images with 99 different patterns based on it. Based on these images, this study carries out sensibility evaluation and analyzes experimental data applying the rough set theory. As a result of the analysis, the combinations of form elements that affect harmony or mismatch act greatly when the colors and shapes of the pillars, positions and the patterns of the use of the first floor are combined.

A Study on the Electrical Load Matching Analisys for the optimal utilization of grid-conntected PV system in Apartment Complex (공동주택의 태양광시스템 적용성 평가를 위한 전기부하 매칭 해석연구)

  • Yoon, Jong-Ho;Park, Jae-Sung;Shin, U-Cheul;Park, Jae-Wan
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.04a
    • /
    • pp.49-54
    • /
    • 2008
  • This study is to investigate an optimal size and position of PV system for apartment complex enough the electrical load matching analysis. The 4 types of arrangements of apartment buildings are considered as follows; ㅡtype, alternative ㅡtype, ㄱtype and ㅁtype. We assume that the studied site is composed of 9 buildings. Firstly, solar access evaluation of roof and facade in apartment buildings was performing with the hourly simulations of total received insolation on each surface considering the hading effect of buildings. Electrical load profile of typical Korean apartments was investigated for the lad matching analysis. To calculate an annual total PV output, we used MERIT program which is a sourly based load matching tool developed by ESRU. TRY weather data of Daejeon are applied for this analysis. Result shows that approximately 11% of total electric load of the site can be supplied by the PV system in the case of full installation of PV system at the whole south-face roof area of 9 buildings in this stuided apartment complex. Depending of a various installation option of roof and facade area, the possible ratio of PV supply in total electrical load varies from 9% to 42%. Among the 4 arrangement types, the ㅡ type revealed the best option for the maximum output of PV system.

  • PDF